* DellEMC S6000, xcvrd support
* sleep 1 second to avoid busy looping
* removal of dead code
* Correct typo error to 1 second
* Introduced 1 second sleep
* Revamped script with blocking call support
* get_transceiver_change_event api definition update
* adding timeout support for get_transceiver_change_event
* Add new device CIG CS6436-56P
* Delete minigraph.xml
It isn't necessary in the current system, just delete it
* Update qos.json.j2
* Update port_config.ini
Add the speed column. The cmd to show interface status as:
root@switch1:~# show interface status
Interface Lanes Speed MTU Alias Oper Admin Type Asym PFC
----------- --------------- ------- ----- ------------ ------ ------- ------ ----------
Ethernet0 8 25G 9100 Ethernet1/1 up up SFP N/A
Ethernet1 9 25G 9100 Ethernet2/1 up up SFP N/A
Ethernet2 10 25G 9100 Ethernet3/1 down down N/A N/A
Ethernet3 11 25G 9100 Ethernet4/1 down down N/A N/A
Ethernet4 12 25G 9100 Ethernet5/1 down down N/A N/A
Ethernet5 13 25G 9100 Ethernet6/1 down down N/A N/A
Ethernet6 14 25G 9100 Ethernet7/1 down down N/A N/A
Ethernet7 15 25G 9100 Ethernet8/1 down down N/A N/A
Ethernet8 16 25G 9100 Ethernet9/1 down down N/A N/A
Ethernet9 17 25G 9100 Ethernet10/1 down down N/A N/A
Ethernet10 18 25G 9100 Ethernet11/1 down down N/A N/A
Ethernet11 19 25G 9100 Ethernet12/1 down down N/A N/A
Ethernet12 20 25G 9100 Ethernet13/1 down down N/A N/A
Ethernet13 21 25G 9100 Ethernet14/1 down down N/A N/A
Ethernet14 22 25G 9100 Ethernet15/1 down down N/A N/A
Ethernet15 23 25G 9100 Ethernet16/1 down down N/A N/A
Ethernet16 32 25G 9100 Ethernet17/1 down down N/A N/A
Ethernet17 33 25G 9100 Ethernet18/1 down down N/A N/A
Ethernet18 34 25G 9100 Ethernet19/1 down down N/A N/A
Ethernet19 35 25G 9100 Ethernet20/1 down down N/A N/A
Ethernet20 40 25G 9100 Ethernet21/1 down down N/A N/A
Ethernet21 41 25G 9100 Ethernet22/1 down down N/A N/A
Ethernet22 42 25G 9100 Ethernet23/1 down down N/A N/A
Ethernet23 43 25G 9100 Ethernet24/1 down down N/A N/A
Ethernet24 48 25G 9100 Ethernet25/1 down down N/A N/A
Ethernet25 49 25G 9100 Ethernet26/1 down down N/A N/A
Ethernet26 50 25G 9100 Ethernet27/1 down down N/A N/A
Ethernet27 51 25G 9100 Ethernet28/1 down down N/A N/A
Ethernet28 56 25G 9100 Ethernet29/1 down down N/A N/A
Ethernet29 57 25G 9100 Ethernet30/1 down down N/A N/A
Ethernet30 58 25G 9100 Ethernet31/1 down down N/A N/A
Ethernet31 59 25G 9100 Ethernet32/1 down down N/A N/A
Ethernet32 64 25G 9100 Ethernet33/1 down down N/A N/A
Ethernet33 65 25G 9100 Ethernet34/1 down down N/A N/A
Ethernet34 66 25G 9100 Ethernet35/1 down down N/A N/A
Ethernet35 67 25G 9100 Ethernet36/1 down down N/A N/A
Ethernet36 68 25G 9100 Ethernet37/1 down down N/A N/A
Ethernet37 69 25G 9100 Ethernet38/1 down down N/A N/A
Ethernet38 70 25G 9100 Ethernet39/1 down down N/A N/A
Ethernet39 71 25G 9100 Ethernet40/1 down down N/A N/A
Ethernet40 72 25G 9100 Ethernet41/1 down down N/A N/A
Ethernet41 73 25G 9100 Ethernet42/1 down down N/A N/A
Ethernet42 74 25G 9100 Ethernet43/1 down down N/A N/A
Ethernet43 75 25G 9100 Ethernet44/1 down down N/A N/A
Ethernet44 76 25G 9100 Ethernet45/1 down down N/A N/A
Ethernet45 77 25G 9100 Ethernet46/1 down down N/A N/A
Ethernet46 78 25G 9100 Ethernet47/1 down down N/A N/A
Ethernet47 79 25G 9100 Ethernet48/1 down down N/A N/A
Ethernet48 84,85,86,87 100G 9100 Ethernet49/1 up up QSFP28 N/A
Ethernet49 80,81,82,83 100G 9100 Ethernet50/1 up up QSFP28 N/A
Ethernet50 92,93,94,95 100G 9100 Ethernet51/1 down down N/A N/A
Ethernet51 88,89,90,91 100G 9100 Ethernet52/1 down down N/A N/A
Ethernet52 108,109,110,111 100G 9100 Ethernet53/1 down down N/A N/A
Ethernet53 104,105,106,107 100G 9100 Ethernet54/1 down down N/A N/A
Ethernet54 116,117,118,119 100G 9100 Ethernet55/1 down down N/A N/A
Ethernet55 112,113,114,115 100G 9100 Ethernet56/1 down down N/A N/A
root@switch1:~#
* [HWSKU] Added Arista-7060CX-32S-Q24C8 HWSKU
Added an Arista HWSKU with 24x40G + 8x100G ports
The ports are distributed along core lines
Signed-off-by: Michel Moriniaux <m.moriniaux@criteo.com>
* [HWSKU] Added Arista-7060CX-32S-T96C8 HWSKU
Added the bcm config files for a 96x25G+8x100G ToR
Signed-off-by: Michel Moriniaux <m.moriniaux@criteo.com>
* [HWSKU] Added Arista-7060CX-32S-Q24C8 HWSKU
Added an Arista HWSKU with 24x40G + 8x100G ports
The ports are distributed along core lines
Signed-off-by: Michel Moriniaux <m.moriniaux@criteo.com>
[devices] add new accton platform minipack.
Add support for new platform, minipack.
It has
CPU: Broadwell DE – D1527
MAC: Tomahawk3(BCM56980).
PHY:Broadcom BCM81724, 4 pcs, Gearbox for PIM-16Q
BMC:AST2520
8 hot-swappable Port-Interface-Modules, each of them has 16*100G QSFP.
- What I did
Add device and platform files for minipack.
- How I did it
Add as SONiC Porting Guide.
- How to verify it
decode-syseeprom
sensors
psuutil
sfputil
thermal monitor
bcmsh on port status
(port LEDs may not working)
* [dell/Z9100] Fix for optics not detected in fanout mode
This commit fixes the issue of optics not detected
error while running sfputil show eeprom command. The root
casuse was the value of port index from port_config.ini for
fan out scenario. The port index should be starting from 0
and not 1. Platform cpld registers are assuming the port
numbers to start from 0 (lowermost bit), sfputils.py uses this
port number in get_presence function. Since the indexing passed
is wrong the optics was not detected and gave SFP EEPROM not
detected message.
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@Dell.com>
* [dell/z9100] Fix for optics not detected in fanout mode
This commit fixes the issue of optics not detected error
while running sfputil show eeprom command. The root cause
was wrong port_index in fan out scenarios. Earlier fix of
changing the port_config.ini is reverted and changes made
in z9100 platform specific sfputil.py file. The port number
is decrement and tested for both 100G and 50G fanout cases.
Tested for the following show commands and test was succesful
show interfaces status, show interfaces transceiver eeprom,
show interfaces transceiver lpmode, show interface tranceiver
presence.
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@Dell.com>
* QoS config change: 1) DSCP mapping; 2) link pg/queue 6 to lossy buffer;
3) redistribute scheduler
Signed-off-by: Wenda <wenni@microsoft.com>
* Add scheduling weight to queue 2
Signed-off-by: Wenda <wenni@microsoft.com>
* Link pg/queue 2 to lossy buffer
Signed-off-by: Wenda <wenni@microsoft.com>
* Update the pg headroom for a7060-D48C8 50G
Signed-off-by: Wenda <wenni@microsoft.com>
* Update config gen test for qos
Signed-off-by: Wenda <wenni@microsoft.com>
* Update pg headroom size, and update egress lossy pool size accordingly
Signed-off-by: Wenda <wenni@microsoft.com>
* Update headroom pool size; Update ingress service pool and egress lossy
pool sizes accordingly;
Signed-off-by: Wenda <wenni@microsoft.com>
* a7260: update headroom pool size; Update ingress service pool and egress lossy pool sizes accordingly;
Signed-off-by: Wenda <wenni@microsoft.com>
* Update config gen test for buffer
Signed-off-by: Wenda <wenni@microsoft.com>
The sai profile itself can support 32x50G+16x100G/40G while
the initial port_config.ini uses 40G speeds for port 17-32.
Signed-off-by: Zhenggen Xu <zxu@linkedin.com>
- Also initialized the number of cos queues in AS5712 to 8.
Else the interfaces are not coming up due to a lower default value of cos queues in AS5712.
Fix:
- Enable alpm settings in the platform config file for AS5712.
- With the current values of l2_mem_entries (163840) and l3_mem_entries (81920), the memory is not sufficient. Scale them down to the
values that work for ALPM in as5712 [l2_mem_entries = 32768, l3_mem_entries = 16384].
Signed-off-by: kiran.kella@broadcom.com
dell_ich module fails to load sometimes due to the failure of pci_get_drvdata().
This function is responsible for fetching INTEL PCI related memory handle in kernel. This is implemented in lpc_ich kernel module.
Due to race in addition/deletion of kernel modules, sometimes lpc_ich loads after dell_ich.
Because of this behaviour dell_ich module fails to load.
Fixed by addding dependency between modules.
Removed i2c_mux_gpio module from blacklist entry as it is not the original root case of this issue.
This commit has the forward porting of changes from 20180330
to master. Unit tested by checking the broadcom registers
for the values. The values in hardware reflect the correct values
except for TC to PFC priority group map values. Master branch values
for TC to PFC priority group map for both z9100 and s6100 in incorrect,
I have a build of Oct 12 master and the values are correct in
that build.
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@Dell.com>
* Use default timeout value which will block the select function
* Submodule update for argument type issue in Select class
Submodule update sonic-swss-common:
e8caaea - Align the argument type with epoll_wait() (#255)
3ea133d - [selectable]: Update throw message (#253)
Signed-off-by: Kevin Wang <kevinw@mellanox.com>
* Upgrade SAI to v1.2.4
* Add a new supported device accton as7116
* Add maintainer info for deb
* Add mk file for accton 7116
* fix some bug for sai 1.2.4
* fix git commit error for sdk and sai
* change sai and sdk deb name
* add config file for qos support
* initial commit
* Delete qos.json
* Delete buffers.json.j2
* Delete qos.json
* Delete buffers.json.j2
* Delete buffers.json.j2
* Delete qos.json
* add support for sai 1.3.0
* add qos and buffer file for device and add sensor driver for 7116
* change buffer template
* fix fan led bug
* add support for linux-4.9
* update device driver and update sdk and sai for support kernel 4.9
* 1) DSCP 46 to 5; 2) ecn config for lossless traffic; 3) ecn on by default; 4) DWRR equal weight;
Signed-off-by: Wenda <wenni@microsoft.com>
* 1) link pg & queue 5 to lossy buffer profile; 2) ingress lossless alpha 1/8
Signed-off-by: Wenda <wenni@microsoft.com>
* Update the test case for qos & buffer json template
Signed-off-by: Wenda <wenni@microsoft.com>
* Migrate a7050-qx32 and s6000 to use pg_profile lookup architecture
Signed-off-by: Wenda <wenni@microsoft.com>
* Update pg headroom egress service pool for a7050-qx-32s, a7050-qx32, and s6000
Signed-off-by: Wenda <wenni@microsoft.com>
* Link queue 5 to lossy profile
Signed-off-by: Wenda <wenni@microsoft.com>
* xcvrd OIR support for Dell S6100/Z9100 switches
Introduced check_interrupts function to handle missed interrupts.
port_dict updated and returned for appropriate OIR events.
Added support for both S6100/Z9100 switches.
* Revamped sfputil.py for PEP8 Standards
* Add kernel cmdline, tg3.short_preamble=1 tg3.bcm5718s_reset=1, to validate mdio to external PHY.
Signed-off-by: roy_lee <roy_lee@accton.com>
* Push submodule, sonic-linux-kernel, to patch of tg3 short_preamble.
Signed-off-by: roy_lee <roy_lee@accton.com>
* Restore to former version, for this platform is not maintained by Accton.
Signed-off-by: roy_lee <roy_lee@accton.com>
* Update arista drivers submodule
* Ignore the possible timestamp warning in tar extraction
* Add verbosity toggle to boot0
Console logging is slow because of the 9600 baud rate.
Some time can be saved by decreasing the console verbosity.
* Add hook mechanism in boot0.
Support additional features in boot0 via hooks.
Hooks are unpacked and executed at post-install or pre-exec time.
* Fix 7170 sensors.conf file
Fix critical temperature settings for MAX6658 sensors
* Fix the random swap of storage devices
For arista 7050 switches running with linux 4.9, it is likely the device
name of flash drive (/dev/sda) and usb (/dev/sdb) randomly swap in kernel
booting, depending on which one is ready first. It breaks the expectation
that flash will be mounted as root by setting root=/dev/sda1. This patch
will correct ROOT to flash device refering to the path under block_flash.
* Fix 7170 fancontrol
* Do not remove aquota.user file in boot0
This file is a filesystem protected file used by EOS.
It can be simply removed and will make the SONiC installation failed if
not skipped.
* syncd changes to disk and add e1000 driver to sonic vm
* add pg_profile_lookup.ini
Signed-off-by: Guohan Lu <gulv@microsoft.com>
* update swss and sairedis
sairedis:
* d146572 2018-11-22 | Fix interface name used on link message using lane map (#386)
swss:
* c74dc60 2018-11-22 | [vstest]: use eth1~32 as physical interface name in vs docker (#700) (HEAD -> master, origin/master, origin/HEAD) [lguohan]
* 6007e7f 2018-11-22 | [portmgrd]: Fix setting default port admin status and MTU (#691) [stepanblyschak]
* 6c70f6d 2018-11-22 | [portsorch] Fix port queue index init bug (#505) [yangbashuang]
* 70ac79b 2018-11-21 | [gitignore]: Update all binary names in the ignore list (#698) [Shuotian Cheng]
* 2a3626c 2018-11-21 | [test]: Remove duplicate legacy ACL tests (#699) [Shuotian Cheng]
* 8099811 2018-11-20 | [aclorch]: Remove unnecessary warning message (#696) [Shuotian Cheng]
* 63d8ebc 2018-11-18 | [portsorch]: Remove duplicate local variables - port (#690) [Shuotian Cheng]
* 28dc042 2018-11-18 | Remove default docker name value of swss. (#692) [Jipan Yang]
Signed-off-by: Guohan Lu <gulv@microsoft.com>
* Unify qos config with qos_config.j2 template
Signed-off-by: Wenda <wenni@microsoft.com>
* Change 7050 to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: device/arista/x86_64-arista_7050_qx32/Arista-7050-QX32/qos.json.j2
modified: device/arista/x86_64-arista_7050_qx32s/Arista-7050-QX-32S/qos.json.j2
* Change a7060, a7260, s6000, s6100, z9100 to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
* Change mlnx devices to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: ../../../mellanox/x86_64-mlnx_msn2100-r0/ACS-MSN2100/qos.json.j2
modified: ../../../mellanox/x86_64-mlnx_msn2410-r0/ACS-MSN2410/qos.json.j2
modified: ../../../mellanox/x86_64-mlnx_msn2700-r0/ACS-MSN2700/qos.json.j2
modified: ../../../mellanox/x86_64-mlnx_msn2700-r0/Mellanox-SN2700-D48C8/qos.json.j2
* Change barefoot devices to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: barefoot/x86_64-accton_wedge100bf_32x-r0/montara/qos.json.j2
modified: barefoot/x86_64-accton_wedge100bf_65x-r0/mavericks/qos.json.j2
* Change accton as7212 to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: accton/x86_64-accton_as7212_54x-r0/AS7212-54x/qos.json.j2
* Apply PORT_QOS_MAP to active ports only
Signed-off-by: Wenda <wenni@microsoft.com>
* Update qos config test with qos_config.j2 template
Signed-off-by: Wenda <wenni@microsoft.com>
* Update sample output of qos-dell6100.json
Signed-off-by: Wenda <wenni@microsoft.com>
* Remove generating the default port name and index list, i.e., remove the generate_port_lists macro, because PORT is always defined
Signed-off-by: Wenda <wenni@microsoft.com>
* Include pfc_to_pg_map according to platform asic type obtained from
/etc/sonic/sonic_version.yml rather than specifying per hwsku
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Customize TC_TO_PRIORITY_GROUP_MAP and
PFC_PRIORITY_TO_PRIORITY_GROUP_MAP for barefoot
Signed-off-by: Wenda <wenni@microsoft.com>
* Unify PFC_PRIORITY_TO_PRIORITY_GROUP_MAP: remove "0":"0", "1":"1" as
these two pgs do not generate PFC frames.
Signed-off-by: Wenda <wenni@microsoft.com>
Snmp container needs to access the PSU path, but /bsp doesn't mount
into the container, so need to use the real path rather than a symlink.
Signed-off-by: Kevin Wang <kevinw@mellanox.com>
Update the hw-mgmt to latest release V.2.0.0060.
Update the related files according to the latest hw-mgmt.
Signed-off-by: Kevin Wang <kevinw@mellanox.com>
* [device]: Add support for Mellanox MSN2010
MSN2010 runs on Spectrum silicon and has 22 ports:
18 25GbE and 4 100GbE
* [device]: Fix a potential qos config issue for MSN2700
Signed-off-by: Kevin Wang <kevinw@mellanox.com>
* [updategraph] add support to use preset config instead of default minigraph
* Fix variable case
* Remove default minigraph case
* Remove default minigraphs and add default_sku files
* [device][platform] d6254qs d6556 platform porting
[device][platform] sensor and status led support for d7032q28b d7254q28b d7264q28b d6254qs d6556
[device][platform] qos support for d7032q28b d7254q28b
[device][platform] service configuration files for d7032q28b d7254q28b d7264q28b d6254qs d6556
* remove binary files and remove non-supported attributes in config.bcm
* remove gpio-ich here. file a PR in sonic-linux-kernel instead.
* remove unnecessary comments
* add GPL license
* Update ag9032v1 and ag9064 modules.
Signed-off-by: neal tai <neal.tai@deltaww.com>
* Fix the sfputil.py when convert an integer to hexadecimal without the 'L' trailing.
Signed-off-by: neal tai <neal.tai@deltaww.com>
* [platform/haliburton] Fix kernel panic when remove smc module.
* [platform/haliburton] Chanage sysfs to support module interrupt
* [device/haliburton] Update sfputil to use new sysfs.
* [device/haliburton] sfputil to support xcvrd monitoring.
for ecn on/off operations, which are conducted at per queue all interfaces granularity.
TODO:
Ideally, we should have ECN/WRED profile applied at per interface per queue
granularity, and we should do it for all hwskus under the device
directory, not just 7050.
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* update sfputil, port indext start from 1
* DX010 update SKUs port config index
Port index in port_config.ini now start from 1.
* Seastone-DX010-10-50 port config update
* Seastone-DX010-50 port config update
* Seastone-DX010 port config update
* Update dx010 sfputil plugin
* Implement lpmode set function.
* Implement transceiver reset function.
* Python code style format.
* Remove new line at the end of port_config.ini
*New line cause parsing error in sfputilbase.
* Add get_transceiver_change_event method
*This needed by new sfputilbase implement.
* Fix unintended line breaks
* [device]: Modify SFPUtil for inventec-d7032
[device]: Add front panel led support for Inventec-d7032
[platform]: Add transceiver monitor daemon for Inventec-d7032 and Inventec-d7054
* [device] follow new porting guide to have broadcom config under device folder
* remove license
* Added new platform support DellEMC - Z92264f - 64x100
* Includes changes with Makefiles, sfputil, eeprom and default minigraph
* Led support for Z9264f platform
* Includes changes on default minigraph
* ipmitool implementation in pmon docker. platform_sensors script is inclued in pmon startup
* Upgrade SAI to v1.2.4
* Add a new supported device accton as7116
* Add maintainer info for deb
* Add mk file for accton 7116
* fix some bug for sai 1.2.4
* fix git commit error for sdk and sai
* change sai and sdk deb name
* add config file for qos support
* initial commit
* Delete qos.json
* Delete buffers.json.j2
* Delete qos.json
* Delete buffers.json.j2
* Delete buffers.json.j2
* Delete qos.json
* add support for sai 1.3.0
* add qos and buffer file for device and add sensor driver for 7116
* change buffer template
* [mlnx-sfpplugin] enhancement to support tranceiver sensor monitoring
* Modify the eeprom folder to make it accessably from pmon container
* implement the get_transceiver_change_event API
file change list
modified: device/mellanox/x86_64-mlnx_lssn2700-r0/plugins/sfputil.py
modified: device/mellanox/x86_64-mlnx_msn2100-r0/plugins/sfputil.py
modified: device/mellanox/x86_64-mlnx_msn2410-r0/plugins/sfputil.py
modified: device/mellanox/x86_64-mlnx_msn2700-r0/plugins/sfputil.py
modified: device/mellanox/x86_64-mlnx_msn2740-r0/plugins/sfputil.py
signed-off-by Liu Kebo kebol@mellanox.com
* remove commented code
* revise the get_transceiver_change_event implementation and remove unused function
* remove blank
* Initial commit
* Add Ingrasys S9180-32X platform dirver.
Signed-off-by: Wade He <chihen.he@gmail.com>
* Add bfn.service for init barefoot.
Signed-off-by: Wade He <chihen.he@gmail.com>
* [Barefoot Beta] Add some functions and fixed some bugs.
1. Update sensors.conf.
2. Fixed IO expander init.
3. Fixed PSU EEPROM.
4. Fixed MB EEPROM.
5. Add fancontrol and fan init.
6. Add SYS LED control (sys, fan, fan tray).
7. 2.5V compute and setup max and min.
8. Fixed typo MB eeprom delete address.
9. Remove coretemp to BMC.
10. Add active CPLD.
11. Modify SFP+ GPIO slave address.
12. Modify tmp75 Near Port 32 slave address.
Signed-off-by: Wade He <chihen.he@gmail.com>
* Add bfn script in /etc/init.d/
Signed-off-by: Wade He <chihen.he@gmail.com>
* Add bfn service in debian
Signed-off-by: Wade He <chihen.he@gmail.com>
* Fixed CPLD switch LED behavior.
Signed-off-by: Wade He <chihen.he@gmail.com>
* [Barefoot Beta] Fixed sensors and hwmon order.
1. Fixed ignore sensors Vbat.
2. Reorg hwmon order.
Signed-off-by: Wade He <chihen.he@gmail.com>
* Fixed PSU1 and PSU2 EEPROM order.
Signed-off-by: Wade He <chihen.he@gmail.com>
* initial barefoot checkin october 2017
* update refpoint
* update refpoints
* update refpoints to bf-master
* update refpoint
* update refpoint to tested version
* change to platform from asic
* update refpoint for swss
* revert core creation setting
* update refpoints
* add telnet for debug shell
* update refpoints 11/17/17
* missed change in file on previous merge
* [CPLD] Fixed blink LED issue.
* Fixed blink LED mask set error.
Signed-off-by: Wade He <chihen.he@gmail.com>
* Update bf_kdrv.c for 6.0.2.39
* Update bf kernel driver
* Add bf_fun kernel module.
* Update bf_tun for fixed build error
* merge with Azure master (12/12/17)
* update swss refpoint
* update refpoint of swss
* library dependency for stack unroll
* update refpoint to bf-master
* [DHCP relay]: Fix circuit ID and remote ID bugs (#1248)
* [DHCP relay]: Fix circuit ID and remote ID bugs
* Set circuit_id_len after setting circuit_id_len to ip->name
* [Platform] Add Psuutil and update sensors.conf for S9100-32X, S8810-32Q and S9200-64X (#1272)
* Add I2C CPLD kernel module for psuutil.
* Support psuutil script.
* Add voltage min and max threshold.
* Update sensors.conf for tmp75.
Signed-off-by: Wade He <chihen.he@gmail.com>
* Allow multi platform support - infra (more changes to follow)
* update relative path to include platform for clarity
* [Platform] Add Ingrasys S9130-32X and S9230-64X with Nephos Switch ASIC for "branch 201712" (#1274)
- What I did
Add switch ASIC vendor: Nephos
Add Nephos platforms: Ingrasys S9130-32X, Ingrasys S9230-64X
- How I did it
Add platform/nephos files
Add platform/nephos/sonic-platform-modules-ingrasys submodule
Add device/ingrasys/x86_64-ingrasys_s9130_32x-r0 files
Add device/ingrasys/x86_64-ingrasys_s9230_64x-r0 files
Add SONiC to support Nephos platform
Update Head of submodule src/sonic-sairedis to "3b817bb"
- How to verify it
To build SONiC installer image and docker images, run the following commands:
make configure PLATFORM=nephos
make target/sonic-nephos.bin
Check system and network feature is worked as well
- Description for the changelog
Add switch ASIC vendor and platforms for Nephos
- A picture of a cute animal (not mandatory but encouraged)
Signed-off-by: Sam Yang <yang.kaiyu@gmail.com>
* change source of files to github (from dropbox), update sairedis refpoint
* update refpoint of sairedis
* [centec] support CENTEC SAI 1.0 on 201712 branch and update e582-48x6q board (#1269)
* [marvel]: Marvell's updates for SONiC.201712 & SAI v1.0 (#1287)
* update sairedis (fast-boot refpoint)
* fix syncd rpc make files
* update refpoint to handle Makefile change (no functional change)
* [Marvell]: Add support for SLM5401-54x device (#1307)
* Marvell's updates for SONiC.201712 & SAI v1.0
* [Platform] Add Marvell's SLM5401-54x for branch 201712
* [Broadcom]: Update Boradcom SAI package to 3.0.3.3-3 (#1312) (#1321)
- update Arista 7050-QX32S config.bcm file
- update Accton th-as771*-32x100G.config.bcm files
* update refpoint for Makefile chnage in sairedis
* update refpoint - sairedis
* update sairedis to older refpoint till we debug clean build
* export asic platform for build
* update refpoint for makefiles
* [PLATFORM] Centec update E582 driver fan/epprom/sensor (#1332)
* Upload wnc-osw1800
* Modify for Barefoot suggest
* Revert bfn-platform.mk
* Update bfn-platform-wnc.mk
Update parameter name
* Update parameter name
* initial support for WNC platform
* change switch name to "switch"
* Delete bf modules for rel_7_0
* Add Ingrasys S9180 platform
Signed-off-by: Wade He <chihen.he@gmail.com>
* Modify bfnsdk for Ingrasys S9180 platform
Signed-off-by: Wade He <chihen.he@gmail.com>
* Resolved the conflict.
* Resolved the conflict.
* Update submodule path and url.
* Delete unused file.
* Update PSU GPIO and EEPROM for psuutil.
* Add psuutil in S9180-32X
Signed-off-by: Wade He <chihen.he@gmail.com>
* update refpoint
* update refpoint
* change contact email, update refpoint
* cleanup and update kernel modules
* updates based on review
* update refpoint
* update refpoint
* fix typo in config script to check for platforms
* remove stale file
* resolve conflicts
* cleanup diffs with Azure repo and update SDK debs
* update refpoints to Azure
* address review comments
* revert refpoint of swss-common
* porting the build fix from master
* porting build fix from master
* Minor Fix
* Minor fix
* Temp to sde deb packages url
* Update sonic - sairedis,swss & swss-common refpoints
* Update git modules url path to bfn repo
* updated paths for swss, swss-common & sairedis
* Update refpoint for sonic-swss to local bfn repo
* Update URL for downloading sde debian packages
* porting fix links of debian git server from master
* porting fix links of debian git server from master
* [Ingrasys] Add platform support for S9280-64X with Barefoot ASIC
* Update ref points for swss, swss-common and sairedis repos
* Add sonic platform scripts for bfn montara/maverick
* Call sh scripts instead of calling py scripts
* Address upstream PR Comments (#10)
* Update bf-master with azure/master
* Undo changes to some files
* Revert "Address upstream PR Comments (#10)"
This reverts commit a7fddb83ca.
* Address upstream comments (#11)
* Remove all non bfn specific changes from upstream PR
* Revert "Address upstream comments (#11)"
This reverts commit 559132103e.
* Undo non bfn changes
* Little more cleanup
* Add back code removed in merge
* export CONFIGURED_PLATFORM
* Update sairedis and swss refpoints
* Address Upstream PR comment
* change deb pkg dependency from 3.16.0-4-amd64 to 3.16.0-5-amd64
* Set default tx queue len for usb0 interface to 64
* Update sairedis refpoint
* Update swss ref point
* Add bfn buffer cfg files for montara/maverick as per new design
* Update buffer cfg templates for bfn montara
* add non zero size to buffer profile
* add macro to generate port lists
* Update buffer cfg templates for bfn mavericks
* add non zero size for buffer profiles
* add port generation macro
* Add missing psmisc package
* BGP docker seems to be missing killall utility being used by fast-reboot script. This is causing non graceful termination of BGP sessions.
Adding psmisc to resolve this issue.
* Update swss ref point
* Update swss ref point
* Update sairedis refpoint
* Update sairedis refpoint
* Update sairedis refpoint
* Update sairedis refpoint
* Update refpoint for sairedis and swss
* sairedis to azure master
* swss to latest bfn bf-master
* Update gitmodules
Update url for sairedis to azure master
* Correct typo in bfn platform script
* Update swss and sairedis ref points
* Update swss ref point
* Address Review comments
* Update swws path in gitmodules to azure master
* update swss refpoint
* update base docker j2 file -remove psmisc package (could be a concern, would cause fast reboot to not work correctly will fix in another PR)
* Fix sairedis refpoint broken in by previous merge
* Remove psmisc from docker base image
* This will break fast reboot as killall is required for killing bgp process and initiating graceful termination of BGP session.
Will fix this in a seperate PR. Need this for SONIC upstreaming
* Address upstream comments
* Remove bmc interface from interface jinja template and sample output interfaces file
* Add bmc interface at boot time to network interfaces for bfn bmc based platforms
* Remove autogen ingrasys debian files
* Revert "Remove autogen ingrasys debian files"
* Buffer and qos config template fix for bfn platforms (#21)
SWI-1509 Buffer and qos config template fix for bfn platforms
* Fix qos config files for montara & mavericks (#22)
* Reference only ppg 3,4 in qos files as no profiles are attached to 0,1 in buffer configs
* Fix vs test (#23)
* Upgrade SAI to v1.2.4
* Add a new supported device accton as7116
* Add maintainer info for deb
* Add mk file for accton 7116
* fix some bug for sai 1.2.4
* fix git commit error for sdk and sai
* change sai and sdk deb name
* add config file for qos support
* initial commit
* Delete qos.json
* Delete buffers.json.j2
* Delete qos.json
* Delete buffers.json.j2
* Delete buffers.json.j2
* Delete qos.json
* add support for sai 1.3.0
This commit updates the shared headroom value for z9100
T0 and T1 profile based on the ratio. The ratio is derived
from the 40G broadcom recommended XL Sheet.
Unit tested the above configuration by dumping the registers
for the shared headroom. The shared headroom values in registers
reflects the correct new values for both T1 and T0.
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@dell.com>
* Update sensors.conf for 7050QX-32 and 7050QX-32S
These two platforms were using a previous version of a kernel driver.
The new one names the i2c buses differently.
We therefore need to rename them here.
* Fix the default minigraph for the 7050QX-32S
The interface offset is invalid which makes sonic-cfggen generate an
invalid config_db.jon in rc.local.
This config then silently makes orchagent/syncd fail.
* Use the partition on which sonic-aboot.swi is
Instead of always assuming /mnt/flash, use the partition where the image
to be installed lies.
This allow for the image to be on any partition.
Move the ingress lossless profile from buffers.json.j2 to pg_profile_lookup.ini
Move pool and the rest of the profile from buffers.json.j2 to
buffers_defaults_t1.j2
Add port speed info in port_config.ini
Make buffers_default_t1.j2 the default profile in buffers.json.j2
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* First part of skipping not used port for qos configuration
* Use active ports only to set QoS parameters for 6100
* Add a test for qos.json.j2
* Add a test for Dell S6100 buffers.json template
* Update submodulre
* Add Broadcom config files for Arista-7050-QX32 and Arista-7050-Q16S64 SKUs under respective directories
* Remove 'serdes_firmware_mode_xe=0x1' line from Arista 7050 Broadcom config files
This commit adds new code to support z9100 PFC T1 support with
broadcom recommended MMU settings for PFC feature.
Unit tested the setting by loading sonic-broadcom.bin and checking
the hardware for the values from the JSON file. Added the config.bcm
file th-z9100-32x100G.config.bcm to this folder and updated the
sai.profile file to point to hwsku directory. sai.profile now
points to /usr/share/sonic/hwsku/th-z9100-32x100G.config.bcm
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@dell.com>
This commit adds new code to support z9100 PFC T0 support with
broadcom recommended MMU settings for PFC feature.
Unit tested the setting by loading sonic-broadcom.bin and checking
the hardware for the values from the JSON file. The T0 configs supports
fan-out of 100G ports on Z9100. Added new config.bcm for fanout of 100G
ports and tested the fanout by sending traffic using bcmcmd, new config.bcm
file will be copied to /usr/share/sonic/hwsku/th-z9100-8x100-48x50G.config.bcm.
The sai.profile file is updated to point to hwsku directory.
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@dell.com>
* [test] Adding Broadcom configuration file test
In order to allow SONiC community to check in Broadcom configuration
file directly under device folder. We need to add this test to make
sure the contents of the configuration is compliant with Broadcom
specifications.
* Invoke test from Debian package builder
* Use $() syntax
* Remove the debug echo statement
This commit updates the pg_profile_lookuip.ini file with
correct xoff values for 50G. 25G/40m xoff value is updated
to reflect the correct value.
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@dell.com>
* [platform]: Add a new supported platform, Delta-ag5648
CPU : Intel Rangeley C2538
Swich ASIC: Broadcom Tomahawk BCM56967
Ports : 48x25G + 6x100G
Switch SKU : Delta-ag5648
Signed-off-by: neal tai <neal.tai@deltaww.com>
* Delete the file
Delete the auto-generated file.
* [device]: ag5648 remove all *.cmd files.
remove the files under ag5648/modules
Signed-off-by: neal tai <neal.tai@deltaww.com>
* [device]: ag5648 device drivers
1. Use the common driver dni_emc2305.c
ag9032v1 device drivers
1. Move dni_emc2305.c to be the common driver
2. Remove at24.c
Signed-off-by: neal tai <neal.tai@deltaww.com>
* [device/dell] Added dynamic sai.profile generation
This commit addds new code for generating dynamic sai.profile file.
The sai.profile.j2 will generate the sai.profile dynamically based on
the topology. It will generate the sai.profile under /etc/sai.d/ directory
in syncd. Before syncd is started this J2 file will be run from the start.sh
file from /usr/bin/ directory. Since the sai.profile is dynamically generated
the old sai.profile file is not required so deleted the file for S6100.
It also address couple of more changes for port_config.ini support is added
for speed in the file which can be used later to find the port speed. Also
the buffer_default_t*.j2 file the ports should be from 0 to 64 changed.
Unit tested the code on S6100 for dynamic generation of sai.profile file for
both T0 and T1 and the file was created in /etc/sai.d/sai.profile
Similarly tested the sonic binary on S6000 to make sure that the sai.profile is
copied from the /usr/share/sonic/hwsku/sai.profile to /etc/sai.d/sai.profile.
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@dell.com>
* [sonic-buildimage] Updating module sai-redis
Updating the sonic-sairedis point.
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@dell.com>
* Reduce xoff size for in-flight packets of lossless traffic
Signed-off-by: Wenda <wenni@microsoft.com>
* Must explicitly specify min buffer size per queue to be zero
Signed-off-by: Wenda <wenni@microsoft.com>
This commit has the workaround for sai.profile to point to
config.bcm T0 profile. This fix will be reverted once the
sai.profile.j2 dynamically generates this file.
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@dell.com>
* Improve memory utilization through more sharing at the ingress on A7050-QX-32S
Signed-off-by: Wenda <wenni@microsoft.com>
* Apply buffers config changes on A7050-QX-32S to A7050-QX32
Signed-off-by: Wenda <wenni@microsoft.com>
* Apply buffers config changes on A7050-QX-32S to S6000
* Add psuutil for S8900-54XC and S8900-64XC.
* Update syseeprom to CPU EEPROM for S9130-32X, S9200-64X and S9230-64X.
* Update sensors.conf for S9200-64X and S9230-64X.
* Update submodule for platform/broadcom/sonic-platform-modules-ingrasys
Signed-off-by: Wade He <chihen.he@gmail.com>
This commit adds new code which supports the new buffer mgmt infra.
- Added new code to support buffers for T0 and T1 configs of S6100.
- Added new qos.json file to support qos on S6100.
- Changed the pg_profile_lookup.ini file to support xon_offset.
- Changed buffer.json.j2 file according to new buffer mgmt infra.
Unit tested by verifying the above changes by loading S6100 with the
configuration, checked the hardware for broadcom recommended settings
by running bcmcmd. Sent the unit test logs to Ying.
Checked the PG_RESET_OFFSET value which reflects the new xon_offset value of 2288
from the pg_profile_lookup.ini.
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@dell.com>
* Add qos.json for Arista-7050-QX-32S
This file is a modification from the one in the swss docker, and is applied in the base image
Signed-off-by: Wenda <wenni@microsoft.com>
* Prepare buffers.json.j2 alongside with qos.json to allow qos config to take
effect on a7050-QX-32S
Signed-off-by: Wenda <wenni@microsoft.com>