- Why I did it
To include latest fixes.
1. On CMIS modules, after low power configuration, the firmware waited for the module state to be ModuleReady instead of ModuleLowPower causing delays.
2. When connecting SN4600C, 100GbE port with CWDM4 module (Gen 3.0), link up time is 30 seconds.
3. Add T1 ECMP Overlay support
- How I did it
Updated SDK/SAI submodule and relevant makefiles with the required versions.
- How to verify it
Build an image and run tests from "sonic-mgmt".
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
- Why I did it
Optimize thermal control policies to simplify the logic and add more protection code in policies to make sure it works even if kernel algorithm does not work.
- How I did it
Reduce unused thermal policies
Add timely ASIC temperature check in thermal policy to make sure ASIC temperature and fan speed is coordinated
Minimum allowed fan speed now is calculated by max of the expected fan speed among all policies
Move some logic from fan.py to thermal.py to make it more readable
- How to verify it
1. Manual test
2. Regression
Taken from https://github.com/Azure/sonic-buildimage/pull/9539
#### Why I did it
To fix an issue that hw-mgmt patches were not applied. One patch was already in upstream hw-mgmt package thus applying it again caused an error and no other patches were applied. Also, I did it to improve the Makefile, so that the make will fail in case patches fail to apply.
#### How I did it
Removed obsolete patch, made applying patches a hard failure in the build.
#### How to verify it
Run the make and verify patches are applied.
- Why I did it
Bug fix:
bad_param request due to missing parser rest command while running mlxlink
- How I did it
Advance to MFT tool version to 4.17.2-12.
- How to verify it
Manually tested on all mellanox platforms.
- Why I did it
Update hw-mgmt to a new version to pick up support for the SN4600C A1 system.
- How I did it
Update the pointer of the hw-mgmt submodule
Update the hw-mgmt version number
Remove the staled code patch to hw-mgmt userspace code.
- How to verify it
Run platform regression on Mellanox platforms.
Signed-off-by: Kebo Liu <kebol@nvidia.com>
- Why I did it
To have an ability to use PRM sniffer.
- How I did it
Enabled the option in configure flags.
- How to verify it
Built and ran on switch. Enabled the feature in runtime and checked the sniffer recording.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
Backport https://github.com/Azure/sonic-buildimage/pull/9259 to 202012
#### Why I did it
Nvidia platform API does not support set LED to orange.
#### How I did it
Allow user to set LED to orange
#### How to verify it
Manual test
Why I did it
Arista did not update db with eeprom info. Previous PR had issues that were reverted.
How I did it
Had Arista eeprom class inherit the class that has method to update db. Updated platform API methods for Arista 202012.
How to verify it
In redis-cli the keys and values can be seen. Can use sonic-mgmt testing to verify behavior, and see the chassis platform API methods have not regressed.
- Why I did it
Support zero buffer profiles
1. Add buffer profiles and pool definition for zero buffer profiles
2. Support applying zero profiles on INACTIVE PORTS
3. Enable dynamic buffer manager to load zero pools and profiles from a JSON file
- How I did it
Add buffer profiles and pool definition for zero buffer profiles
If the buffer model is static:
* Apply normal buffer profiles to admin-up ports
* Apply zero buffer profiles to admin-down ports
If the buffer model is dynamic:
* Apply normal buffer profiles to all ports
* buffer manager will take care when a port is shut down
Update buffers_config.j2 to support INACTIVE PORTS by extending the existing macros to generate the various buffer objects, including PGs, queues, ingress/egress profile lists
Originally, all the macros to generate the above buffer objects took active ports only as an argument.
Now that buffer items need to be generated on inactive ports as well, an extra argument representing the inactive ports need to be added.
To be backward compatible, a new series of macros are introduced to take both active and inactive ports as arguments
The original version (with active ports only) will be checked first. If it is not defined, then the extended version will be called.
Only vendors who support zero profiles need to change their buffer templates
Enable buffer manager to load zero pools and profiles from a JSON file:
The JSON file is provided on a per-platform basis
It is copied from platform/<vendor> folder to /usr/share/sonic/temlates folder in compiling time and rendered when the swss container is being created.
To make code clean and reduce redundant code, extract common macros from buffer_defaults_t{0,1}.j2 of all SKUs to two common files:
One in Mellanox-SN2700-D48C8 for single ingress pool mode
The other in ACS-MSN2700 for double ingress pool mode
Those files of all other SKUs will be symbol link to the above files
Update sonic-cfggen test accordingly:
* Adjust example output file of JSON template for unit test
* Add unit test in for Mellanox's new buffer templates.
- How to verify it
Regression test.
Unit test in sonic-cfggen
Run regression test and manually test.
Signed-off-by: stephens <stephens@nvidia.com>
- Why I did it
To include latest fixes.
1. On CMIS modules, after low power configuration, the firmware waited for the module state to be ModuleReady instead of ModuleLowPower causing delays.
2. When connecting Spectrum devices with optical transceivers that support RXLOS, remote side port down might cause the switch firmware to get stuck and cause unexpected switch behavior.
3. On rare occasions, when working with port rates of 1GbE or 10GbE and congestion occurs, packets may get stuck in the chip and may cause switch to hang.
4. When ECMP has high amount of next-hops based on VLAN interfaces, in some rare cases, packets will get a wrong VLAN tag and will be dropped.
5. Using SN4600C with copper or optics loopback cables in NRZ speeds, link may raise in long link up times ( up to 70 seconds).
6. When connecting SN4600C to SN4600C after Fastboot in 50GbE No_FEC mode with a copper cable, the link up time may take ~20 seconds.
- How I did it
Updated SDK submodule and relevant makefiles with the required versions.
- How to verify it
Build an image and run tests from "soni-mgmt".
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
- Why I did it
This is to update the common sonic-buildimage infra for reclaiming buffer.
- How I did it
Render zero_profiles.j2 to zero_profiles.json for vendors that support reclaiming buffer
The zero profiles will be referenced in PR [Reclaim buffer] Reclaim unused buffers by applying zero buffer profiles #8768 on Mellanox platforms and there will be test cases to verify the behavior there.
Rendering is done here for passing azure pipeline.
Load zero_profiles.json when the dynamic buffer manager starts
Generate inactive port list to reclaim buffer
Signed-off-by: Stephen Sun <stephens@nvidia.com>
- Why I did it
When PSU is powered off, the PSU is still on the switch and the air flow is still the same. In this case, it is not necessary to set FAN speed to 100%.
- How I did it
When PSU is powered of, don't treat it as absent.
- How to verify it
Adjust existing unit test case
Add new case in sonic-mgmt
1. CS00012211718 [4.3] Pfcwd getting continuously triggered/restored when pause frames are sent continuously to both queues of a port (TD2/Th/Th2/TD3) MSFT Default
Preliminary tests look fine. BGP neighbors were all up with proper routes programmed
interfaces are all up
Manually ran the following test cases on 7050CX3 (TD3) T0 DUT and all passed:
```
fib/test_fib.py
vxlan/test_vxlan_decap.py
fdb/test_fdb.py
decap/test_decap.py
ipfwd/test_dip_sip.py
ipfwd/test_dir_bcast.py
acl/test_acl.py
vlan/test_vlan.py
platform_tests/test_reboot.py
```
This is to pick up BRCM SAI 4.3.5.1-7 fixes which contains the following fixes:
1. CS00012209390: SONIC-50037, Used SAI_SWITCH_ATTR_QOS_DSCP_TO_TC_MAP as a default decap map for IPinIP tunnels.
2. CS00012212995: SONIC-50948 SAI_API_QUEUE:_brcm_sai_cosq_stat_get:1353 egress Min limit get failed with error Invalid parameter
3. SONIC-51583: Fixed acl group member creation failure with priority of -1
4. CS00012215744:SONIC-51395 [TH, TH2] WB 3.5 to 4.3 fails at APPLY_VIEW while setting SAI_PORT_ATTR_EGRESS_ACL
5. SONIC-51638: SDK-249337 ERROR: AddressSanitizer: heap-buffer-overflow in _tlv_print_array
Preliminary tests look fine. BGP neighbors were all up with proper routes programmed
interfaces are all up
Manually ran the following test cases on 7050CX3 (TD3) T0 DUT and all passed:
```
fib/test_fib.py
vxlan/test_vxlan_decap.py
fdb/test_fdb.py
decap/test_decap.py
ipfwd/test_dip_sip.py
ipfwd/test_dir_bcast.py
acl/test_acl.py
vlan/test_vlan.py
platform_tests/test_reboot.py
```
This is to pick up BRCM SAI 4.3.5.1-6 fixes which contains the following fixes:
1. CS00012213351 SONIC-50679: [TH, TH2] Warm-reboot from 3.5 to 4.3 fails due to null objects discovered
2. CS00012182162: SONIC-49805 TD3 MMU config profile optimization changes
3. CS00012210826:SONIC-50205/760c60fc: Should read MMU_INTFI_MMU_PORT_TO_MMU_QUEUES_FC_BKP for TH3
Preliminary tests looks fine. BGP neighbors were all up with proper routes programmed
interfaces are all up
Manually ran the following test cases on 7050CX3 (TD3) T0 DUT and all passed:
```
fib/test_fib.py
vxlan/test_vxlan_decap.py
fdb/test_fdb.py
decap/test_decap.py
ipfwd/test_dip_sip.py
ipfwd/test_dir_bcast.py
acl/test_acl.py
vlan/test_vlan.py
platform_tests/test_reboot.py
```
* [Nokia ixs7215] Platform API fixes
This commit delivers the following fixes
- Fix bug preventing access to second PSU eeprom
- Fix bug preventing updates to front panel PSU status led
- Fix SFP reset test case failure
* Fix LGTM alert
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
Why I did it
The previous PR #8914 was reverted due to crashing the 202012 syseepromd.
How I did it
Tested the 202012 image with change and fixed the disparity between master and 202012.
How to verify it
Run the built image on the dut and syseepromd will not crash, and in redis-cli can fetch the eeprom information.
Why I did it
Sujin noticed that Arista eeprom platform API cannot update the redis database. Although Arista and Guohan believe that database update logic should be part of the daemon, it is easy enough to implement the fix for Arista for now.
How I did it
Made Arista eeprom platform API inherit from TlvInfoDecoder, then write Arista's own visit_eeprom method.
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
Why I did it
Vaibhav Dahiya notified me that invalid fan speed policy was expecting an error raised in sonic-mgmt testing, but it was not raised.
This change will fix test_platform_info.py::test_thermal_control_load_invalid_value_json
How I did it
Add in the suggested code chunk to Arista platform submodule to raise ValueError when an invalid fan speed is set in thermal policy.
How to verify it
Vaibhav Dahiya has verified it through sonic-mgmt testing.
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
- Why I did it
Change thermal recover threshold from temp_trip_norm to temp_trip_high, so that thermal algorithm would set fan speed to minimum allowed earlier and save power.
- How I did it
Change thermal recover threshold from temp_trip_norm to temp_trip_high
- How to verify it
Manual test
Why I did it
To monitor the SSD health condition in DellEMC S6100 platform post upgrade.
A daemon is introduced to monitor the SSD every one hour.
To check for SSD status at boot time and at the time of cold-reboot.
All these changes are supported only for newer SSD firmware.
Porting changes from 201911 branch
Added a platform_reboot_pre_check script to prevent cold-reboot based on SSD status.
Depends on Azure/sonic-utilities#1788
DO NOT MERGE UNTIL ABOVE PR IS MERGED
How I did it
On branch s6100_ssd_202012
Changes to be committed:
(use "git restore --staged ..." to unstage)
modified: platform/broadcom/sonic-platform-modules-dell/debian/platform-modules-s6100.install
new file: platform/broadcom/sonic-platform-modules-dell/s6100/scripts/iSMART_64
new file: platform/broadcom/sonic-platform-modules-dell/s6100/scripts/platform_reboot_pre_check
modified: platform/broadcom/sonic-platform-modules-dell/s6100/scripts/s6100_platform.sh
new file: platform/broadcom/sonic-platform-modules-dell/s6100/scripts/s6100_ssd_mon.sh
new file: platform/broadcom/sonic-platform-modules-dell/s6100/scripts/s6100_ssd_upgrade_status.sh
new file: platform/broadcom/sonic-platform-modules-dell/s6100/scripts/soft-reboot_plugin
new file: platform/broadcom/sonic-platform-modules-dell/s6100/systemd/s6100-ssd-monitor.service
new file: platform/broadcom/sonic-platform-modules-dell/s6100/systemd/s6100-ssd-monitor.timer
new file: platform/broadcom/sonic-platform-modules-dell/s6100/systemd/s6100-ssd-upgrade-status.service
* [Nokia ixs7215] Miscellaneous platform API fixes
This commit delivers the following fixes for the Nokia ixs7215 platform
- Fix bug in a fan API error path
- Add support for setting the fan drawer led
- Add support for getting/setting the front panel PSU status led
- Add support for getting the min/max observed temperature value
* [Nokia ixs7215] code review changes: temperature min/max values
Why I did it
Power cycle test case fails for Z9332f in sonic-mgmt framework(#8605).
How I did it
Modified the platform API to return expected strings.
How to verify it
Power cycle the device and verify the reboot reason.
Run sonic-mgmt test_reboot script.
- Why I did it
Update SDK\FW version to 4.4.3326\2008.3326. This version contains:
New Features:
1. Add support for Fast Boot for SN3800
Bug Fixing:
1. In some cases, when the total number of allocations exceeds the resource limit, an error can occur due to incorrect resource release procedure. This issue is most likely to affect the following resources: flow counters, ACL actions, PBS, WJH filter, Tunnels, ECMP containers, MC (L2 &L3)
2. On Spectrum systems, when using Async Router API with IPV6, an error message in the log regarding failing to remove ECMP container may show up. This error is not functional and can be safely ignored.
3. On Spectrum-2 systems and above, when using warm boot, setting max_bridge_num to a value greater than 1968 will cause an error and potential crash.
4. Some Molex cables do not support speed after reboot
- How I did it
Update submodule and .mk files
- How to verify it
Verified by running regression tests that includes complete sonic-mgmt tests supported
Signed-off-by: Shlomi Bitton <shlomibi@nvidia.com>
To enable saiserver docker on different platforms, it needs different configuration files. make the saiserver docker mount them in hwsku folder.
Co-authored-by: Ubuntu <richardyu@richardyu-ubuntu-vm0.trsxrdzozv2e1czsze2t05vqzh.ix.internal.cloudapp.net>
This commit adds support for changing the default console baud rate configured
within the U-Boot bootloader. That default baud rate is exposed via the value
of the U-Boot 'baudrate' environment variable. This commit removes logic that
hardcoded the console baud rate to 115200 and instead ensures that the U-Boot
'baudrate' variable is always used when constructing the Linux kernel boot
arguments used when booting Sonic.
A change is also made to rc.local to ensure that the specified baud rate is set
correctly in the serial getty service.
#### Why I did it
New PSU could install different type of fan, so fan max/min speed should be read per PSU
#### How I did it
The existing implementation read PSU max/min fan speed from a common file, change it to read from per PSU file
#### How to verify it
Manual test
- Why I did it
New release of MFT has the following changelog / RN
Fixed an issue that resulted in getting MVPD read errors from the mlxfwmanager during fast reboot.
Fixed mlxuptime sometimes generating a time less than previous due the wrong frequency calculation
- How I did it
Update makefile pointer to new version.
- How to verify it
Manually tested on all Mellanox platforms.
Fix Chassis.get_name to return the same value than what's in platform.json
Fix Chassis.get_system_eeprom_info when running from within pmon.
Fix Watchdog.get_remaining_time (fixes [202012 platform_tests] TestWatchdogApi::test_remaining_time failure on vms20-t1-7050cx3-3.1 #8440 and [ 202012 platform_tests ] TestWatchdogApi::test_arm_disarm_states failure on vms20-t1-7050cx3-3.1 #8439)
Implement missing thermal infos and conditions (fixes [202012 platform_tests] test_platform_info.py::test_thermal_control_psu_absence error #8453)
Fix Chassis.set_status_led return value (fixes [2020 platform_tests] TestChassisApi::test_status_led failure on vms20-t0-7050cx3-1 #8464)
To fix failed test cases of Haliburton platform APIs that found on platform_tests script
- How I did it
- Add device/celestica/x86_64-cel_e1031-r0/platform.json
- Update functions to support python3.7
- Add more functions follow latest sonic_platform_base
- Fix the bug
Signed-off-by: Wirut Getbamrung [wgetbumr@celestica.com]
Deliver sfputil support for sfputil show eeprom and sfputil reset along with some component test case fixes
Co-authored-by: Carl Keene <keene@nokia.com>
Why I did it
fix the dx010 system eeprom unavailable issue
How I did it
enable the i2c slave 30ms timeout mechanism
How to verify it
i2cstress test in DX010 iSMT controller bus
Co-authored-by: nicwu-cel <nicwu@celestica.com>
Update Makefile, so it does the following:
For a given platform, verify if platform/checkout/.ini exists and
hence run the platform/checkout/template.j2. This allows platform
code to be checked out during the 'make configure' stage.
Why I did it
serial-getty service exited in Dell S6100 device randomly.
How I did it
Added serial-getty to monit services.
How to verify it
Stop serial-getty in ssh session and check whether the service restarts or not.
the branch refers the branch name that the commit is in,
for example master, 202012, 201911, ...
In case there is no branch, the name will be HEAD.
release is encoded in /etc/sonic/sonic_release file.
the file is only available for a release branch.
It is not available in master branch.
Signed-off-by: Guohan Lu <lguohan@gmail.com>
Why I did it
platform test suite failed for few API's in DellEMC Z9332f platform.
How I did it
Modified the API's to return the expected values in the script.
How to verify it
Run platform test suite after making the changes.
This is to pick up BRCM SAI 4.3.5.1 which contains the following fix:
CS00012201406: [4.3.3.9] SAI_STATUS_FAILURE on FDB flush after all ports flapped
Preliminary tests looks fine. BGP neighbors were all up with proper routes programmed
interfaces are all up
Manually ran the following test cases on z9332f (TH3) T0 DUT and all passed:
```
ipfwd/test_dir_bcast.py
fib/test_fib.py
```
Manually ran the following test cases on S6100 (TH) and all passed:
```
ipfwd/test_dir_bcast.py
fdb/test_fdb.py
```
This PR only contains backports from master
Fix leak discovered on master, though 202012 is not affected it's better to have the fix (fixes [master] thermalctld leak on Arista devices makes them unreachable when memory is exhausted #7515)
Fix EepromDecoderimplementation in the platform API (fixes syseepromd crashing repeatedly on SONiC.20201231.02 #8263)
Fix Mineral platform definition and configuration
Fix build issues in environments where /proc is not mounted/restricted (fixes PLATFORM=broadcom fails arista "ReloadCauseManagerTest" first time #7800)
Fix some pytest issues
Add sfp-eeprom C API and also mount it in pmon
Why I did it
BIOS upgrade on rare cases cannot guarantee bus value remain the same on every BIOS release. Ignoring this field in order for pcied not to fail but still verify device id in a different way. The solution is future proof and will not require changes in code when new BIOS version is available
How I did it
Since bus is not a fixed value (it is determined by the bios version) we are ignoring this field, and instead checking if there is a device that match on all other fields that and in addition has a matching device id.
How to verify it
Verify no errors or failures in pcied on different BIOS version with the same code base.
- Why I did it
to prevent python exception error when executing warm-reboot command on mellanox simulator platform
- How I did it
return None on the watchdog python script on cases that watchdog file is not exist
- How to verify it
warm-reboot is running well without the python error. error message will appear on log on these cases.
in order to avoid this error message we can simulate the watchdog on mellanox simulator platform
- Removed the old function for detecting a faulty fan.
- Removed the old function for detecting excess temperature.
- Implement thermal_manager APIs based on ThermalManagerBase
- Implement thermal_conditions APIs based on ThermalPolicyConditionBase
- Implement thermal_actions APIs based on ThermalPolicyActionBase
- Implement thermal_info APIs based on ThermalPolicyInfoBase
- Add thermal_policy.json
Why I did it
To determine the revision of the pcie.yaml to be used based on BIOS version in DellEMC S6100 platform.
Depends on: Azure/sonic-platform-common#195
How I did it
Added two revisions of pcie.yaml pcie_1.yaml and pcie_2.yaml
Included a platform-specific Pcie class to provide the revision of the pcie.yaml to be used by pcieutil/pcied.
How to verify it
Execute pcieutil check (Azure/sonic-utilities#1672) command and verify the list of PCIe devices displayed.
Logs: UT_logs.txt
Use udevadm to trigger the udev rules on the first boot
How to verify:
- Connect C0 with E1031;
- Install or upgrade the sonic os to 202012 branch;
- When access to sonic check if /dev/C0-1 to /dev/C0-48 are existed.
Update FW version to 2008.3218, fixing the following issues:
- 50G/100G links that are operationally down before warm-reboot are not coming up after warm-reboot
- 50G/100G links with admin shut / no shut commands are not coming up after warm-reboot
Signed-off-by: Dror Prital <drorp@nvidia.com>
- Changes and new features:
1. Added support in SN4600C systems for new module Finisar ET7402-CWDM4 (100G CWDM4 QSFP28 1310nm SM 2KM).
2. Added support for new module MMS1W50-HM (2km transceiver FR4) for 200GbE
3. Improved performance of "per-port-buffer" counters
4. Added support for Kernel 5.10
- Bug fix:
On rare occasions (0.5%), in SN4600C systems, when using 100GbE NRZ mode and Fastboot flow, the link up time may take up to 10 seconds
Signed-off-by: Dror Prital <drorp@nvidia.com>
#### Why I did it
Support API 2.0 for S5248F platform
#### How I did it
Making changes to S5248F platform specific directory
Co-authored-by: Arun LK <Arun_L_K@dell.com>
#### Why I did it
The debian install files are required for installing sonic_platform packages
#### How I did it
Add install files to under debian folder
Co-authored-by: robert.hong <robert.hong@qct.io>
Add device and platform code for ix7-bwde, ix8a-bwde.
Support platform API 2.0 for all quanta platforms except for ix1b
Co-authored-by: robert.hong <robert.hong@qct.io>
Why I did it
There were two regression issues introduced by BRCM SAI 4.3.3.8:
CS00012196056 [4.3.3.8][WARMBOOT] syncd[2584]: segfault at 5616ad6c3d80 ip 00007f61e0c6bc65 sp 00007fff0c5a7a90 error 4 in libsai.so.1.0[7f61e0a95000+3cd8000]
CS00012195956 [4.3.3.8] [TD3]Syncd Crash at brcm_sai_tnl_mp_create_tunnel()
How I did it
Patch for CS00012195956 from BRCM was validated to have addressed the tunnel creation issue.
Temporary worked around the issue by commenting out a portion of questionable code in BRCM SAI that seems to be the root cause of CS00012196056 .
How to verify it
See the BRCM cases for details.