* [Nokia ixs7215] Miscellaneous platform API fixes
This commit delivers the following fixes for the Nokia ixs7215 platform
- Fix bug in a fan API error path
- Add support for setting the fan drawer led
- Add support for getting/setting the front panel PSU status led
- Add support for getting the min/max observed temperature value
* [Nokia ixs7215] code review changes: temperature min/max values
Why I did it
Power cycle test case fails for Z9332f in sonic-mgmt framework(#8605).
How I did it
Modified the platform API to return expected strings.
How to verify it
Power cycle the device and verify the reboot reason.
Run sonic-mgmt test_reboot script.
- Why I did it
Update SDK\FW version to 4.4.3326\2008.3326. This version contains:
New Features:
1. Add support for Fast Boot for SN3800
Bug Fixing:
1. In some cases, when the total number of allocations exceeds the resource limit, an error can occur due to incorrect resource release procedure. This issue is most likely to affect the following resources: flow counters, ACL actions, PBS, WJH filter, Tunnels, ECMP containers, MC (L2 &L3)
2. On Spectrum systems, when using Async Router API with IPV6, an error message in the log regarding failing to remove ECMP container may show up. This error is not functional and can be safely ignored.
3. On Spectrum-2 systems and above, when using warm boot, setting max_bridge_num to a value greater than 1968 will cause an error and potential crash.
4. Some Molex cables do not support speed after reboot
- How I did it
Update submodule and .mk files
- How to verify it
Verified by running regression tests that includes complete sonic-mgmt tests supported
Signed-off-by: Shlomi Bitton <shlomibi@nvidia.com>
To enable saiserver docker on different platforms, it needs different configuration files. make the saiserver docker mount them in hwsku folder.
Co-authored-by: Ubuntu <richardyu@richardyu-ubuntu-vm0.trsxrdzozv2e1czsze2t05vqzh.ix.internal.cloudapp.net>
This commit adds support for changing the default console baud rate configured
within the U-Boot bootloader. That default baud rate is exposed via the value
of the U-Boot 'baudrate' environment variable. This commit removes logic that
hardcoded the console baud rate to 115200 and instead ensures that the U-Boot
'baudrate' variable is always used when constructing the Linux kernel boot
arguments used when booting Sonic.
A change is also made to rc.local to ensure that the specified baud rate is set
correctly in the serial getty service.
#### Why I did it
New PSU could install different type of fan, so fan max/min speed should be read per PSU
#### How I did it
The existing implementation read PSU max/min fan speed from a common file, change it to read from per PSU file
#### How to verify it
Manual test
- Why I did it
New release of MFT has the following changelog / RN
Fixed an issue that resulted in getting MVPD read errors from the mlxfwmanager during fast reboot.
Fixed mlxuptime sometimes generating a time less than previous due the wrong frequency calculation
- How I did it
Update makefile pointer to new version.
- How to verify it
Manually tested on all Mellanox platforms.
Fix Chassis.get_name to return the same value than what's in platform.json
Fix Chassis.get_system_eeprom_info when running from within pmon.
Fix Watchdog.get_remaining_time (fixes [202012 platform_tests] TestWatchdogApi::test_remaining_time failure on vms20-t1-7050cx3-3.1 #8440 and [ 202012 platform_tests ] TestWatchdogApi::test_arm_disarm_states failure on vms20-t1-7050cx3-3.1 #8439)
Implement missing thermal infos and conditions (fixes [202012 platform_tests] test_platform_info.py::test_thermal_control_psu_absence error #8453)
Fix Chassis.set_status_led return value (fixes [2020 platform_tests] TestChassisApi::test_status_led failure on vms20-t0-7050cx3-1 #8464)
To fix failed test cases of Haliburton platform APIs that found on platform_tests script
- How I did it
- Add device/celestica/x86_64-cel_e1031-r0/platform.json
- Update functions to support python3.7
- Add more functions follow latest sonic_platform_base
- Fix the bug
Signed-off-by: Wirut Getbamrung [wgetbumr@celestica.com]
Deliver sfputil support for sfputil show eeprom and sfputil reset along with some component test case fixes
Co-authored-by: Carl Keene <keene@nokia.com>
Why I did it
fix the dx010 system eeprom unavailable issue
How I did it
enable the i2c slave 30ms timeout mechanism
How to verify it
i2cstress test in DX010 iSMT controller bus
Co-authored-by: nicwu-cel <nicwu@celestica.com>
Update Makefile, so it does the following:
For a given platform, verify if platform/checkout/.ini exists and
hence run the platform/checkout/template.j2. This allows platform
code to be checked out during the 'make configure' stage.
Why I did it
serial-getty service exited in Dell S6100 device randomly.
How I did it
Added serial-getty to monit services.
How to verify it
Stop serial-getty in ssh session and check whether the service restarts or not.
the branch refers the branch name that the commit is in,
for example master, 202012, 201911, ...
In case there is no branch, the name will be HEAD.
release is encoded in /etc/sonic/sonic_release file.
the file is only available for a release branch.
It is not available in master branch.
Signed-off-by: Guohan Lu <lguohan@gmail.com>
Why I did it
platform test suite failed for few API's in DellEMC Z9332f platform.
How I did it
Modified the API's to return the expected values in the script.
How to verify it
Run platform test suite after making the changes.
This is to pick up BRCM SAI 4.3.5.1 which contains the following fix:
CS00012201406: [4.3.3.9] SAI_STATUS_FAILURE on FDB flush after all ports flapped
Preliminary tests looks fine. BGP neighbors were all up with proper routes programmed
interfaces are all up
Manually ran the following test cases on z9332f (TH3) T0 DUT and all passed:
```
ipfwd/test_dir_bcast.py
fib/test_fib.py
```
Manually ran the following test cases on S6100 (TH) and all passed:
```
ipfwd/test_dir_bcast.py
fdb/test_fdb.py
```
This PR only contains backports from master
Fix leak discovered on master, though 202012 is not affected it's better to have the fix (fixes [master] thermalctld leak on Arista devices makes them unreachable when memory is exhausted #7515)
Fix EepromDecoderimplementation in the platform API (fixes syseepromd crashing repeatedly on SONiC.20201231.02 #8263)
Fix Mineral platform definition and configuration
Fix build issues in environments where /proc is not mounted/restricted (fixes PLATFORM=broadcom fails arista "ReloadCauseManagerTest" first time #7800)
Fix some pytest issues
Add sfp-eeprom C API and also mount it in pmon
Why I did it
BIOS upgrade on rare cases cannot guarantee bus value remain the same on every BIOS release. Ignoring this field in order for pcied not to fail but still verify device id in a different way. The solution is future proof and will not require changes in code when new BIOS version is available
How I did it
Since bus is not a fixed value (it is determined by the bios version) we are ignoring this field, and instead checking if there is a device that match on all other fields that and in addition has a matching device id.
How to verify it
Verify no errors or failures in pcied on different BIOS version with the same code base.
- Why I did it
to prevent python exception error when executing warm-reboot command on mellanox simulator platform
- How I did it
return None on the watchdog python script on cases that watchdog file is not exist
- How to verify it
warm-reboot is running well without the python error. error message will appear on log on these cases.
in order to avoid this error message we can simulate the watchdog on mellanox simulator platform
- Removed the old function for detecting a faulty fan.
- Removed the old function for detecting excess temperature.
- Implement thermal_manager APIs based on ThermalManagerBase
- Implement thermal_conditions APIs based on ThermalPolicyConditionBase
- Implement thermal_actions APIs based on ThermalPolicyActionBase
- Implement thermal_info APIs based on ThermalPolicyInfoBase
- Add thermal_policy.json
Why I did it
To determine the revision of the pcie.yaml to be used based on BIOS version in DellEMC S6100 platform.
Depends on: Azure/sonic-platform-common#195
How I did it
Added two revisions of pcie.yaml pcie_1.yaml and pcie_2.yaml
Included a platform-specific Pcie class to provide the revision of the pcie.yaml to be used by pcieutil/pcied.
How to verify it
Execute pcieutil check (Azure/sonic-utilities#1672) command and verify the list of PCIe devices displayed.
Logs: UT_logs.txt
Use udevadm to trigger the udev rules on the first boot
How to verify:
- Connect C0 with E1031;
- Install or upgrade the sonic os to 202012 branch;
- When access to sonic check if /dev/C0-1 to /dev/C0-48 are existed.
Update FW version to 2008.3218, fixing the following issues:
- 50G/100G links that are operationally down before warm-reboot are not coming up after warm-reboot
- 50G/100G links with admin shut / no shut commands are not coming up after warm-reboot
Signed-off-by: Dror Prital <drorp@nvidia.com>
- Changes and new features:
1. Added support in SN4600C systems for new module Finisar ET7402-CWDM4 (100G CWDM4 QSFP28 1310nm SM 2KM).
2. Added support for new module MMS1W50-HM (2km transceiver FR4) for 200GbE
3. Improved performance of "per-port-buffer" counters
4. Added support for Kernel 5.10
- Bug fix:
On rare occasions (0.5%), in SN4600C systems, when using 100GbE NRZ mode and Fastboot flow, the link up time may take up to 10 seconds
Signed-off-by: Dror Prital <drorp@nvidia.com>
#### Why I did it
Support API 2.0 for S5248F platform
#### How I did it
Making changes to S5248F platform specific directory
Co-authored-by: Arun LK <Arun_L_K@dell.com>
#### Why I did it
The debian install files are required for installing sonic_platform packages
#### How I did it
Add install files to under debian folder
Co-authored-by: robert.hong <robert.hong@qct.io>
Add device and platform code for ix7-bwde, ix8a-bwde.
Support platform API 2.0 for all quanta platforms except for ix1b
Co-authored-by: robert.hong <robert.hong@qct.io>
Why I did it
There were two regression issues introduced by BRCM SAI 4.3.3.8:
CS00012196056 [4.3.3.8][WARMBOOT] syncd[2584]: segfault at 5616ad6c3d80 ip 00007f61e0c6bc65 sp 00007fff0c5a7a90 error 4 in libsai.so.1.0[7f61e0a95000+3cd8000]
CS00012195956 [4.3.3.8] [TD3]Syncd Crash at brcm_sai_tnl_mp_create_tunnel()
How I did it
Patch for CS00012195956 from BRCM was validated to have addressed the tunnel creation issue.
Temporary worked around the issue by commenting out a portion of questionable code in BRCM SAI that seems to be the root cause of CS00012196056 .
How to verify it
See the BRCM cases for details.
- Why I did it
Split and bulk counter bug fixes:
Init port auto neg to default on static (SAI XML) port split for 2nd+ port
- How I did it
Update submodule hash pointer.
- How to verify it
Verify the above is handled properly and reported issues are assumed to be fixed.
Signed-off-by: Shlomi Bitton <shlomibi@nvidia.com>
- Why I did it
Remove EEPROM cache file and use DB instead
- How I did it
Read EEPROM data from DB if possible
If data is not ready in DB, read from hardware using a visitor pattern
- How to verify it
Manual test and regression
#### Why I did it
Failures observed when running the open community platform test suite (sonic-mgmt)
#### How I did it
Call PSUBase class initializer from derived class
There was an issue on master where `thermal.get_position_in_parent` in the platform API was returning -1 instead of a proper index. This is a backport of the fix for that issue.
- Why I did it
This is to back-port Azure 7410 to 202012 branch.
Enhance the Python3 support for platform API. Originally, some platform APIs call SDK API which didn't support Python 3. Now the Python 3 APIs have been supported in SDK 4.4.3XXX, Python3 is completely supported by platform API
- How I did it
Start all platform daemons from python3
1. Remove #/usr/bin/env python at the beginning of each platform API file as the platform API won't be started as daemons but be imported from other daemons.
2. Adjust SDK API calls accordingly
Signed-off-by: Stephen Sun <stephens@nvidia.com>
- Why I did it
Adjust the Makefile for SDK/python-SDK-API to support both python2 and python3
- How to verify it
Build the image and check whether python2 and python3 are both supported by SDK API.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
To fix determine-reboot-cause service which was failing due to non-implemented thrown from get_reboot_case, if the reboot was done with `sudo reboot` (cold reboot)
Signed-off-by: Volodymyr Boyko <volodymyrx.boiko@intel.com>
Signed-off-by: Yong Zhao yozhao@microsoft.com
Why I did it
Currently we leveraged the Supervisor to monitor the running status of critical processes in each container and it is more reliable and flexible than doing the monitoring by Monit. So we removed the functionality of monitoring the critical processes by Monit.
How I did it
I removed the script process_checker and corresponding Monit configuration entries of critical processes.
How to verify it
I verified this on the device str-7260cx3-acs-1.
This is due to the fact that we use SONIC_OVERRIDE_BUILD_VARS internally
in our build jobs and this is not accounted in caching framework.
So we add MLNX_SDK_DEB_VERSION to force rebuild if we changed it via
SONIC_OVERRIDE_BUILD_VARS.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
#### Why I did it
- After [sonic-linux-kernel#177](https://github.com/Azure/sonic-linux-kernel/pull/177) changes, the I2C mux channels of Baseboard and Switchboard CPLDs are moved from i2c-4 and i2c-5 to i2c-36 and i2c-37 respectively.
- This caused QSFP driver initialization of i2c-36 to i2c-41 to fail causing the ports from Ethernet208 to Ethernet248 fail.
#### How I did it
- The fix to this problem is to change the order of QSFP driver initialization to I2C mux channels.
- Instead of the order i2c-10 to i2c-41, the order i2c-4 to i2c-35 is being utilized.
- Also, need to change the i2c-mux-channel number for Baseboard CPLD and switchboard CPLD in scripts to access them.
#### Why I did it
On our platforms syncd must be up while using the sonic_platform.
The issue is warm-reboot script first disables syncd then instantiate Chassis, which tries to connect syncd in __init__.
#### How I did it
Refactor Chassis to lazy initialize components.
Signed-off-by: Volodymyr Boyko <volodymyrx.boiko@intel.com>
Initialize fans and thermals lists on demand; make them properties in order to reduce Chassis object initialization time
Signed-off-by: Volodymyr Boyko <volodymyrx.boiko@intel.com>
- Why I did it
Update FW version to 2008_3110 fixing SN3800 specific warm boot scenario:
1. Disable interface
2. Warm Boot
3. Enable Interface --> link will remain down.
- How I did it
Use new FW that contains the fix for the problem mentioned above
- How to verify it
Run the scenario mentioned above and make sure that the link is up after warm boot
Signed-off-by: Dror Prital <drorp@nvidia.com>
#### Why I did it
According to thermalctld hld, each fan must belong to a fan drawer, if the fan drawer does not physically exist, put fan into a virtual fan drawer. This PR is to clear fan from chassis._fan_list
#### How I did it
1. Don't put fan to chassis._fan_list
2. Always query fan from fan_drawer
Why I did it
Microsoft reported occasional daemon crashes on devices running 201911. On close inspection it was due to PMBus reads failing on IOError on very rare occasions.
This is the fix for 202012 branch.
How I did it
Add try/except block on performing reads on PMBus GPIOs.
How to verify it
Which release branch to backport (provide reason below if selected)
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
- Why I did it
Pick up fix from new hw-management package:
Fix gearbox thermal zone name, which was lack suffix thermal zone number
- How I did it
Update the hw-management version number in the make file
Update hw-management submodule pointer
- How to verify it
Run platform related test cases on Mellanox platform
Why I did it
This SAI change is to Enable TD2 platforms to also be able to handle VFP-based sub-interfaces.
This is the feature that is also needed for TD2 platforms.
How to verify it
Guohan and Team has validated this feature change on TD2 platforms
#### Why I did it
xcvrd crashes when the application advertisement capability flag is not seen for few transceivers.
#### How I did it
Initialize the additional application capability in dunder init
Add support for Accton as9726-32d platform
This pull request is based on as9716-32d, so I reference as9716-32d to create new model: as9726-32d.
This module do not need led driver to control led, FPGA can handle it.
I also implement API2.0(sonic_platform) for this model, CPLD driver, PSU driver, Fan driver to control these HW behavior.
Why I did it
Fix issues below.
#7133#6602
So, remove the dps200 driver from the platform-specific driver.
Then, add the dps200 module driver to the Linux kernel tree.
How I did it
Remove the dps200 driver from the platform-specific driver and add the dps200 module driver to the Linux kernel.
How to verify it
Build an image with Azure/sonic-linux-kernel#207
Then, install to the Haliburton.
This is to pick up BRCM SAI 4.3.3.5-2 which contains 2 main changes:
1. hsdk-6.5.21-p1.patch (to address some field problems related to SDK issue.
2. Fix for CS00012097141 (remove some unnecessary debug setting that was causing non functional impacting problem at boot time)
Preliminary tests looks fine. BGP neighbors were all up with proper routes programmed
interfaces are all up
Manually ran the following test cases on S6100 DUT and all passed:
```
ipfwd/test_dir_bcast.py
fib/test_fib.py
vxlan/test_vxlan_decap.py
decap/test_decap.py
fdb/test_fdb.py
```
LED_PROC_INIT_SOC variable was incorrectly referenced as LED_SOC_INIT_SOC. Introduced in #5483
Rather than fixing the typo, I decided to simplify the script, removing the need for the conditional altogether by moving the bcmcmd call inside the conditional which checks for the presence of LED_SOC_INIT_SOC.
#### Why I did it
- PSU data is loaded into state DB.
Following errors are seen in syslogs:
"Failed to update PSU data - '<=' not supported between instances of 'float' and 'str'"
- Issue is not seen in master image as the PSU API return type is different.
#### How I did it
- Changed the return type in PSU API's.
#### Why I did it
400G media EEPROM and DOM information are not populated properly in DellEMC Z9332f platform.
#### How I did it
Handled QSFP_DD, QSFP28/QSFP+, SFP+ accordingly based on media type detected.
Incorporate the below changes in DellEMC Z9332F platform:
- Implemented watchdog platform API support
- Implement ‘get_position_in_parent’, ‘is_replaceable’ methods for all device types
- Change return type of SFP methods to match specification in sonic_platform_common/sfp_base.py
- Added platform.json file in device directory.
Co-authored-by: V P Subramaniam <Subramaniam_Vellalap@dell.com>
- Why I did it
Updated FW to xx.2008.2526 version.
Fixed issues:
1. Spectrum-2, Spectrum-3 | sFlow | High CPU load and high on fully loaded switch.
2. Spectrum-2, Spectrum-3 | Fine grain LAG | in rare cases doesn’t update the right entry
- How I did it
Updated submodule pointer and version in a Makefile.
- How to verify it
Full regression and bugs validation
Signed-off-by: Shlomi Bitton <shlomibi@nvidia.com>
#### Why I did it
Adopt a single way to get fan direction for all ASIC types.
It depends on hw-mgmt V.7.0010.2000.2303. Depends on https://github.com/Azure/sonic-buildimage/pull/7419
#### How I did it
Originally, the get_direction was implemented by fetching and parsing `/var/run/hw-management/system/fan_dir` on the Spectrum-2 and the Spectrum-3 systems. It isn't supported on the Spectrum system.
Now, it is implemented by fetching `/var/run/hw-management/thermal/fanX_dir` for all the platforms.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
- Why I did it
To include below changes:
Set monitoring VLAN hostif up dy default (for VNET ping tool)
- How I did it
Updated SAI submodule pointer
- How to verify it
Create VLAN hostif according to changes in PR: Azure/sonic-swss#1645
Verify it is admin up by default
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
- Support compile sonic arm image on arm server. If arm image compiling is executed on arm server instead of using qemu mode on x86 server, compile time can be saved significantly.
- Add kernel argument systemd.unified_cgroup_hierarchy=0 for upgrade systemd to version 247, according to #7228
- rename multiarch docker to sonic-slave-${distro}-march-${arch}
Co-authored-by: Xianghong Gu <xgu@centecnetworks.com>
Co-authored-by: Shi Lei <shil@centecnetworks.com>
The following error message is observed during chassis object being destroyed
"Exception ignored in: <function Chassis.__del__ at 0x7fd22165cd08>
Traceback (most recent call last):
File "/usr/local/lib/python3.7/dist-packages/sonic_platform/chassis.py", line 83, in __del__
ImportError: sys.meta_path is None, Python is likely shutting down
The chassis tries to import deinitialize_sdk_handle during being destroyed for the purpose of releasing the sdk_handle.
However, importing another module during shutting down can cause the error because some of the fundamental infrastructures are no longer available."
This error occurs when a chassis object is created and then destroyed in the Python shell.
- How I did it
To fix it, record the deinitialize_sdk_handle in the chassis object when sdk_handle is being initialized and call the deinitialize handler when the chassis object is being destroyed
- How to verify it
Manually test.
- Why I did it
Upgrade hw-mgmt to 7.0100.2303
Bug fixes
1. Fan direction feature fix for fixed FAN system (using shell instead of binutils/strings)
2. Remove cpld 4th link on systems with only 3 CPLD's
3. hw-mgmt: thermal: Add hardcoded critical trip point. Follow-up after patch "Removing critical thermal zones to prevent unexpected software system shutdown".
4. Fix sensor attribute mapping to be label based instead of index based to allow common handling of voltage regulator names independently of hardware changes.
5. Update 'lm-sensors' custom configuration file. Relevant only for users utilizing sensors.conf files coming along with hw-management package.
6. For full feature list please follow https://github.com/Mellanox/hw-mgmt/blob/V.7.0010.2300_BR/debian/Release.txt
- How I did it
Update hw-mgmt pointer
Remove unused patches
Fix existing patch to make sure it apply successfully
- How to verify it
Full platform regression on all mellanox platforms
- Why I did it
Changes in the new release:
1. Fix 10G and 50G speeds in SAI XML to support all interface types
2. Enable SMAC=DMAC and SMAC MC in tunnel debug counter
3. Add tunnel statistics
4. Add isolation group API implementation
5. Fix ACL ANY debug counter to correctly track ACL drops
6. Add VXLAN source port hard coded range, controlled by K/V
7. FW dump me now feature
8. Add mlxtrace to saidump
9. Speed lane setting and AN control
10. Implement query stats API
11. VNI miss part of tunnel decal drop reason
- How I did it
Update the version number in SAI make file, update the mlnx-sai submodule pointer.
- How to verify it
Run full regression tests on Mellanox platforms
Signed-off-by: Dror Prital <drorp@nvidia.com>
This is the SAI 4.3.3.5 code drop from BRCM to address 2 CSP case and initial MMU changes
Note the MMU changes is the same as that of SAI 4.3.3.4-1 (#7341) but with official patch.
- Case CS00012178716 [4.3] Polling SAI_QUEUE_STAT_SHARED_WATERMARK_BYTES fails often on TH3
- Case CS00012159273 [4.3.3.3] [TD3][IPFWD] subnet broadcast flooding end with extra VLAN Tag if member port of VLAN interface deleted then added back to VLAN
Once we have this PR merged, will validate each one of the above to ensure they are indeed fixed...
Preliminary tests looks fine. BGP neighbors were all up with proper routes programmed
interfaces are all up
Manually ran the following test cases on TD3 DUT and all passed:
ipfwd/test_dir_bcast.py
fib/test_fib.py
vxlan/test_vxlan_decap.py
decap/test_decap.py
fdb/test_fdb.py
New features and fixes in the new SDK/FW:
SN4600C | AN/LT support
SN2700 | AN/LT bugs fixes
WJH | FID_MISS support
Signed-off-by: Kebo Liu <kebol@nvidia.com>
#### Why I did it
- xcvrd crash was seen in latest 201811 images.
- For Dell S6100,API 2.0 uses poll mode while 1.0 was still using interrupt mode.
#### How I did it
- Modified get_transceiver_change_event in 1.0 to poll mode.
Modified the MRVL SAI debian version format to include debian revision number. This helps in identifying the SAI deb causing any build/runtime issue.
Signed-off-by: Rajkumar Pennadam Ramamoorthy <rpennadamram@marvell.com>
* 7260cx3 DualToR config.bcm support based on DualToR setting in device metadata at boot time.
For HWSKU Arista-7260CX3-C64 the MMU setting SOC for T0/T1 is also combined into the config.bcm.j2 logic so use just one config file and adding delta based on Switch Roles.
- Why I did it
Add missed files for dynamic buffer calculation for ACS-MSN3420 and ACS-MSN4410
- How I did it
asic_table.j2: Add mapping from platform to ASIC
Add buffer_dynamic.json.j2 for ACS-MSN4410.
- How to verify it
Check whether the dynamic buffer calculation daemon starts successfully.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
- Why I did it
There was a change to replace platform utils with sonic platform API in psuutil. However, psu API is not initialized on host side. The PR is to fix it.
Backport of #7016 to the 202012 branch.
- How I did it
Initialize PSU API on both host and non-host side
- How to verify it
Manual test
To improve management of docker-gbsyncd-vs. gbsyncd_startup.py simply spawned syncd processes and then exited. In that case, supervisord would no longer manage any processes in the container, and thus there was no way to know if a critical process had exited.
I recently created gbsyncdmgrd to be a more complete, robust replacement for gbsyncd_startup.py.
NOTE: This PR is dependent on the inclusion of gbsyncdmgrd in the sonic-sairedis repo. A submodule update is pending at
#7089
The psample module was not loaded on barefoot platform. The loading of this module is a prerequisite for testing SFlow.
* add `.gitignore` to the `barefoot` subdirectory to overwrite ignore "platform/**/debian/*" in the root directory
Integrate hw-management package V.7.0010.2002
Bug fixes:
Removing critical thermal zones to prevent unexpected software system shutdown:
*Kernel 4.9 -0071-mlxsw-core-Remove-critical-trip-point-from-thermal-z.patch
*Kernel 4.19 -076-mlxsw-core-Remove-critical-trip-point-from-thermal-z.patch
Removing redundant link for cpld3 for fixed systems (SN2100, SN2010).
Fix an issue with missed attribute for cpld3 (port CPLD) for SN2700, SN2410.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
Build Marvell kernel driver for prestera sai sdk
Builds interrupt and dma kernel driver
Removed the older method pre-compiled kernel module debian package and its makefile
Fix the following issues:
Spectrum-2, Spectrum-3 | Port | Fix link issue when using 25 GbE rate between two ports while one is on Spectrum-2-based system and the other is on Spectrum-3-based system
All | warmboot | fail to upgrade from earlier SONiC versions with official SDK/FW 4.4.2306 (was on SONiC 201911)
All | What-Just-Happened | When enabling or disabling WJH under high traffic load to the host CPU, in very specific and low probability conditions, an error could occur, that may result in loss of data, channel failure or in extreme cases SW failure
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
To add latest SAI drop REL_4.3.3.3 to SONIC which addresses the following CSP cases:
CS00012058054: [4.3][IPinIP][TTL-PIPE] IPinIP TTL Pipe Mode is NOT working it is behaving UNIFORM mode even programed as PIPE mode
CS00011227466: [4.3] Warmboot support with tunnel encap
- Why I did it
The existing Fan led and Psu led object initialize itself to green color in init method. However, there are multiple daemons calls sonic platform API and there could be a case that:
A PSU is removed from system
Reboot switch
psud detects that 1 PSU is missing and set PSU led to red
Other daemon just start up and call sonic platform API, the API set PSU led to green by call PsuLed.init
This PR is a partial fix for the issue. As we also need guarantee that the led is initialized with a correct value. I checked existing psud and thermalctld code. psud always initialize the PSU led color on boot up, thermalcltd need some changes to initialize led color on the first run
- How I did it
Remove the led color initialization code from FanLed.init and PsuLed.init
- How to verify it
Manual test
Eliminate the need for `gbsyncd_start.sh`, which simply calls `exec "/usr/bin/gbsyncd_startup.py"`. The shell script is unnecessary.
Once this PR merges, we can remove `gbsyncd_start.sh` from the sonic-sairedis repo.
- Why I did it
To pick up new features and fix from SDK/FW and SAI
SDK/FW new Feature:
All | Added support for multiple modules and cable types. For full list contact Nvidia networking support
Spectrum-3 | SN46000C | Added support for up to 5W on ports 49 to 64 .
SDK/FW bugs' fix:
All | fast reboot | fast boot failure from latest 201811 to 201911 and above
Spectrum | 10GbE/1GbE Transceiver (FTLX8574D3BCV) stopped working after firmware upgrade
Spectrum-2 | When device is rebooted with locked Optical Transceivers in split mode, the firmware may get stuck
Spectrum-2 | SN3700 | When connecting at 200GbE to Ixia K400, Ixia receives CRC errors
Spectrum-2 | SN3800 | On rare occasions packets loss may be experienced due to signal integrity issues
Spectrum-2 | When the port is a member of a LAG, after a warmboot and port toggle on the peer-side, the port remains down
Spectrum-3 | SN4700 | While using Optic cable in Split 4x1 mode in PAM4, when two first ports are toggled, the other 2 ports go down
Spectrum-3 | SN4700 | When working in 400GbE, deleting the headroom configuration (changing buffer size to zero) on the fly may cause continual packet drops
SAI
All | sFlow | Use hardcoded value 1 as netlink group number ax expected by hsflowd
- How I did it
Update the related version number in the make files and update the submodule pointer accordingly.
- How to verify it
Run regression test and everything works good.
To have the following fixes:
* All | Port status remains down after warm boot and flapping the port on peer side
* All | LAG HASH | IPv6 SRC_IP is not accounted in LAG hashing [
* All | ASIC driver | Kernel crash observed when driver reload is initiated before it fully loaded
* Spectrum-3 | Buffer | In lossless configuration, headroom is been evicted only when the shared buffers is free
* All | prevent FW access during ISSU
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
- Why I did it
Update MFT tool version to 4.16.0
Bugs fixes:
mlxlink: Fixed an issue that caused the margin scan to fail with the following message: Eye scan not completed.
mlxcable: Cable firmware burning capability is not supported.
New features:
mlxlink: Enabled margin scan on Network links.
mlxlink: Added PRBS TX/RX polarity inversion using the following flags: --invert_tx_polarity / --invert_rx_polarity
- How I did it
Update MFT make file with new version number.
- How to verify it
Build image and test related functions on Mellanox platform
#### Why I did it
- The xcvrd service requires an event detection function, unplug or plug in the transceiver.
#### How I did it
- Add sysfs interrupt to notify userspace app of external interrupt
- Implement get_change_event() in chassis api.
- Also begin installing Python 3 sonic-platform package for Celestica platforms
- Provide `hw-management-generate-dump.sh` for `show techsupport`
- Load `optoe3` for OSFP and QSFP-DD transceivers
- Enhance reboot-cause caching robustness
Signed-off-by: Samuel Angebault <staphylo@arista.com>
- Why I did it
Add support for new 64x200G SN4600 systems
- How I did it
Add all relevant files (w/o platform.json and hwsku.json as they will come later) with default SKU.
- How to verify it
Install image on switch, verify all ports are up and configured properly, run full platform SONiC tests.
In preparation for the merging of Azure/sonic-platform-common#173, which properly defines class and instance members in the Platform API base classes.
It is proper object-oriented methodology to call the base class initializer, even if it is only the default initializer. This also future-proofs the potential addition of custom initializers in the base classes down the road.
In preparation for the merging of Azure/sonic-platform-common#173, which properly defines class and instance members in the Platform API base classes.
It is proper object-oriented methodology to call the base class initializer, even if it is only the default initializer. This also future-proofs the potential addition of custom initializers in the base classes down the road.
#### Why I did it
To incorporate the below changes in DellEMC S5232, Z9264, Z9332 platforms.
- Update thermal high threshold values
- Make watchdog API Python2 and Python3 compatible
- Fix LGTM alerts
- Z9264: Fix get_change_event timer value
#### How I did it
- Use 'universal_newlines=True' in subprocess.Popen call.
- Change the timeout in 'get_change_event' to milliseconds to match specification in sonic_platform_common/chassis_base.py
The S6000 devices, the cold reboot is abrupt and it is likely to cause issues which will cause the device to land into EFI shell. Hence the platform reboot will happen after graceful unmount of all the filesystems as in S6100.
Moved the platform_reboot to platform_reboot_override and hooked it to the systemd shutdown services as in S6100
- Why I did it
System is stuck on 'starting' state on SimX platform because of infinite loop on 'hw-management-ready.sh' script .
The loop is polling to check if the hw-mgmt sysfs created before proceeding with the flow, for SimX platform the sysfs will never create so the system is not starting properly.
- How I did it
Add a condition to poll on hw-mgmt sysfs only if the switch is real HW and not SimX platform.
- How to verify it
Check "systemctl status hw-management.service" output on a SimX switch with this patch, the state will be "active".
Signed-off-by: Shlomi Bitton <shlomibi@nvidia.com>
- Why I did it
Mellanox SDK APIs support python 2 at the moment.
- How I did it
Mellanox SDK APIs support python 2 at the moment.
- How to verify it
Add python 2 to Mellanox syncd only.
- Which release branch to backport (provide reason below if selected)
docker exec -t syncd /bin/bash -c "sx_api_dbg_generate_dump.py /home/sx_api_dbg_dump"
You can see that it will work and generate /home/sx_api_dbg_dump
Signed-off-by: allas <allas@nvidia.com>
- Why I did it
Bug fixes
- In rare cases when thermal algorithm is reactivated after FAN/PSU insertion, FAN remains at high rpm
- When stop hw-management code received error in the log instead of exit code '0'.
- In SPC1 i2c sometimes collide with chip reset coming from SDK
- Remove raw eeprom data link, when working with PSU which don't have eeprom for "msn274x", "msn24xx" and "msn27xx" systems
- Fix memory leak on mlxsw_core_bus_device module removal
- How I did it
Update the hw-mgmt version number in the make file
Update the hw-mgmt repo pointer
- How to verify it
run platform related test cases on all Mellanox platform
Signed-off-by: Kebo Liu <kebol@nvidia.com>
- Why I did it
The pcie configuration file location is under plugin directory not under platform directory.
#6437
- How I did it
Move all pcie.yaml configuration file from plugin to platform directory.
Remove unnecessary timer to start pcie-check.service
Move pcie-check.service to sonic-host-services
- How to verify it
Verify on the device
- Add support for `DCS-7050SX3-48YC8` and `DCS-7050SX3-48C8` platform
- Add support for more variants of `DCS-7280CR3-32[PD]4`
- Add Supervisor to Linecard consutil support
- Complete Watchdog platform API support
- Fix some PSU behavior on `DCS-7050QX-32` and `DCS-7060CX-32S`
- Fix SEU management on `DCS-7060CX-32S`
- Allow kernel modules to build up to linux 5.10
- Rename led color `orange` to `amber`
- Miscellaneous fixes
#### Why I did it
Fix runtime issues caused by SONiC update
#### How I did it
- new attribute SAI_ACL_ENTRY_ATTR_FIELD_ACL_IP_TYPE supported
- new attribute SAI_SWITCH_ATTR_AVAILABLE_IPMC_ENTRY supported
Signed-off-by: Roman Savchuk <romanx.savchuk@intel.com>
Open ACL Outer VLAN ID for egress for ports part of VLAN RIF
- Why I did it
Open ACL Outer VLAN ID for egress for ports part of VLAN RIF
- How I did it
Updated SAI submodule pointer
- How to verify it
Build an image, deploy and check all is up and running.
Verify ACL sonic-mgmt test is passing
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
- Improve sonic-mgmt platform test suite pass rate
- Improve coverage of platform unit tests
- Provide platform specific reboot logic as per platform porting guide
- Fix bug due to pcie.yaml file being located in the wrong directory