Why I did it
7050 S4Q31 mmu configuration is missing ALPM configurations, causing not enough memory reserved for routes. Orchagent crashes on a nightly testbed with 6400 route entries.
How I did it
Add the missing ALPM configurations.
How to verify it
Load the configuration on testbed and verified new configuration exists and no more crash.
Signed-off-by: Ying Xie ying.xie@microsoft.com
This PR contains the following changes
Original Arista-7050-QX-32S sku (32x40G ports) has been renamed to Arista-7050QX32S-Q32
Arista-7050-QX-32S is symlinked to Arista-7050QX-32S-S4Q31 (4x10G, 31x40G ports)
Signed-off-by: Neetha John <nejo@microsoft.com>
Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
Need proper MMU and Qos settings for Arista-7050QX-32S-S4Q31
How I did it
Updated the settings based on Arista-7050-QX-32S
**- Why I did it**
There is a preference to use thermalctld instead of fancontrol for 201911 release branch. The Arista platform submodule updates and thermal policies in the platforms will allow Arista devices to use thermalctld instead of fancontrol.
**- How I did it**
I cherry-picked the necessary commits from master branch for sonic-platform-modules-arista into 201911 branch. I've also added the file to skip fancontrol and added the thermal policies json.
**- How to verify it**
On Gardena, Upperlake, Clearlake, and Lodoga thermalctld is up and running with no errors. Fans show ~29%.
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
Treat devices that are ToRRouters (ToRRouters and BackEndToRRouters) the same when rendering templates
Except for BackEndToRRouters belonging to a storage cluster, since these devices have extra sub-interfaces created
Treat devices that are LeafRouters (LeafRouters and BackEndLeafRouters) the same when rendering templates
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
However in SAI 3.7 default behaviout got changes to 128 Group and 128
Memeber each.
This change is to make sure we are using same ECMP Group/Memeber Per
Group for 3.7 also so that behaviour is consistent.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
as needed by SAI 3.7 and above. Without this change
Warmboot fails from 3.5 to 3.7 as Braodcoam Datastructure
gets corrupted after warm-boot.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
Merge most of the changes that recently made it to master.
This will be the last such merge operation and future commits will only cherry-pick fixes and targeted features.
Major fixes and features,
- reboot cause enhancement with more hardware reboot cause reporting
- fix reboot cause parsing issue with 201811 release
- fix get_change_event logic
- fix error message on missing sysfs entry by our plugins
- final piece of the platform refactors for fan and sensor reporting through the platform API
thermalctld throwing error messages because it is not yet fully configured, disabling it for now on arista platforms.
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
Dynamic threshold setting changed to 0 and WRED profile green min threshold set to 250000 for Tomahawk devices
Changed the dynamic threshold settings in pg_profile_lookup.ini
Added a macro for WRED profiles in qos.json.j2 for Tomahawk devices
Necessary changes made in qos.config.j2 to use the macro if present
Signed-off-by: Neetha John <nejo@microsoft.com>
* Remove the divide by 4 operation to the under the hood SAI
This is to avoid the need and thus the confusion for application program to know
the mmu internal architecture
This change must have support from SAI change to reach the correct
config
Signed-off-by: Wenda <wenni@microsoft.com>
* Relegate the divide by 4 operation to the under the hood SAI for egress
lossless pool
Extend to 7060 and 6100
Signed-off-by: Wenda <wenni@microsoft.com>
* Add more TH/TH2 hwskus
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Update config test
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Add TH2 ingress lossy profile
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Move the divide by 4 operation to SAI internal
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* [bcm SAI] Upgrade Broadcom SAI to version 3.5.3.1-15
- Broadcom SAI 3.5 GA release 20190924.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* Add boot0 support for the 7280CR3
* Add platform and plugins for 7280CR3
* Add port config for 7280CR3
* Add platform_reboot for 7280CR3
* Add support for 7280CR3-32D4 based on the 7280CR3-32P4
* Update arista driver submodules
- Introduce new 7280CR3-32P4
- Improve to the led plugin for OSFP
* Fix showing systemd shutdown sequence when verbose is set
* Fix creation of kernel-cmdline file
Sometimes boot0 prints error
"mv: can't preserve ownership of '/mnt/flash/image-arsonic.xxxx/kernel-cmdline': Operation not permitted"
* Improve flash space usage during installation
Some older systems only have 2GB of flash available. Installing a second
image on these can prove to be challenging.
The new installation process moves the installer swi to memory in order
to avoid free up space from the flash before uncompressing it there.
It removes all the flash space usage spike and also improves the IO
since the installation is no more reading and writting to the flash at
the same time.
* Add support of 7060CX-32S-SSD
* 7260CX3: use inventory powerCycle procedures
* 7050QX-32S: use inventory powerCycle procedures
* 7050QX-32: use inventory powerCycle procedures
* platform: arista: add common platform_reboot
Replace platform_reboot by a link to new common for devices already
using a similar script.
* 7060CX-32S: use inventory powerCycle procedures
* Install python smbus in pmon
Some platform plugin need the python smbus library to perform some actions.
This installs the dependency.
* [HWSKU] Added Arista-7060CX-32S-Q24C8 HWSKU
Added an Arista HWSKU with 24x40G + 8x100G ports
The ports are distributed along core lines
Signed-off-by: Michel Moriniaux <m.moriniaux@criteo.com>
* [HWSKU] Added Arista-7060CX-32S-T96C8 HWSKU
Added the bcm config files for a 96x25G+8x100G ToR
Signed-off-by: Michel Moriniaux <m.moriniaux@criteo.com>
* [HWSKU] Added Arista-7060CX-32S-Q24C8 HWSKU
Added an Arista HWSKU with 24x40G + 8x100G ports
The ports are distributed along core lines
Signed-off-by: Michel Moriniaux <m.moriniaux@criteo.com>
* QoS config change: 1) DSCP mapping; 2) link pg/queue 6 to lossy buffer;
3) redistribute scheduler
Signed-off-by: Wenda <wenni@microsoft.com>
* Add scheduling weight to queue 2
Signed-off-by: Wenda <wenni@microsoft.com>
* Link pg/queue 2 to lossy buffer
Signed-off-by: Wenda <wenni@microsoft.com>
* Update the pg headroom for a7060-D48C8 50G
Signed-off-by: Wenda <wenni@microsoft.com>
* Update config gen test for qos
Signed-off-by: Wenda <wenni@microsoft.com>
* Update pg headroom size, and update egress lossy pool size accordingly
Signed-off-by: Wenda <wenni@microsoft.com>
* Update headroom pool size; Update ingress service pool and egress lossy
pool sizes accordingly;
Signed-off-by: Wenda <wenni@microsoft.com>
* a7260: update headroom pool size; Update ingress service pool and egress lossy pool sizes accordingly;
Signed-off-by: Wenda <wenni@microsoft.com>
* Update config gen test for buffer
Signed-off-by: Wenda <wenni@microsoft.com>