Why I did it
Add no-export to bgp sentinel community-list. So that bgp updates from bgp sentinel service must match sentinel community and no-export, otherwise, the bgp update will be dropped.
Work item tracking
Microsoft ADO (24946274):
How I did it
Add no-export to bgp sentinel community-list.
How to verify it
Run UT, case would pass. Build the image and start the device. Add bgp sentinel and check that no-export community exist in bgp sentinel community list.
#### Why I did it
To support SKIP_BUILD_HOOK for curl command so the targets downloaded by curl (SONIC_ONLINE_DEBS, SONIC_ONLINE_FILES) can utilize it.
##### Work item tracking
- Microsoft ADO **(number only)**:
#### How I did it
Add a logic to invoke a real command instead of a `download_packages()` (the same way it's done for wget)
#### How to verify it
Add an online target (with URL attribute).
Add the "SKIP_VERSION=y" to this target.
Check that download_packages is not invoked.
Add yang model for IPv4 DHCP Server.
Add four new tables: DHCP_SERVER_IPV4, DHCP_SERVER_IPV4_CUSTOMIZED_OPTIONS, DHCP_SERVER_IPV4_RANGE, DHCP_SERVER_IPV4_PORT
Bmc is a valid neighbor type in minigraph, however it was missing from the YANG model definition. Usually, the Bmc type device can be neighbor of BmcMgmtToRRouter. This PR is to introduce this type.
Why I did it
According to ACL-Table-Type-HLD, the value type of MATCHES, ACTIONS and BIND_POINTS should be list instead of string. Opening this PR to update the definition of BMCDATA and BMCDATAV6.
How I did it
Update the definition of BMCDATA and BMCDATAV6 in minigraph-parser.
How to verify it
Verified by UT and build SONiC image.
How I did it
Update Yang definition of ACL_TABLE_TYPE.
Update existing testcase.
Add new testcase to cover lowercase key scenario.
How to verify it
Verified by building sonic_yang_models-1.0-py3-none-any.whl. While building the target package, unit tests were run and passed.
- Why I did it
Fixed build failure when flag ENABLE_SFLOW_DROPMON=y set
- How I did it
Fixed sflow dropmon patch to align with hsflowd version 2.0.45
Signed-off-by: rajkumar38 <rpennadamram@marvell.com>
- Why I did it
Enabled port late create on SN5600 Spectrum-4 switch boots up with no ports
Work item tracking
N/A
- How I did it
Updated SAI xml config file
- How to verify it
Run sonic-mgmt tests of fastboot
Signed-off-by: Nazarii Hnydyn <nazariig@nvidia.com>
#### Why I did it
src/sonic-gnmi
```
* 7a1b7cd - (HEAD -> master, origin/master, origin/HEAD) Improve full path logic (#146) (37 minutes ago) [ganglv]
```
#### How I did it
#### How to verify it
#### Description for the changelog
#### Why I did it
src/sonic-linux-kernel
```
* a2aa335 - (HEAD -> master, origin/master, origin/HEAD) PATCH] net: allow user to set metric on default route learned via Router Advertisement (#326) (12 hours ago) [abdosi]
```
#### How I did it
#### How to verify it
#### Description for the changelog
### Why I did it
When PFC WD is triggered there is no diagnosis information which makes it difficult to understand why PFC WD was triggered. So, we add a field `additional_information` to accommodate the diagnosis information.
### How to verify it
unit test
Ignore intermittent IO errors during get_change_event in the Platform API
Fix tunings for some ports on CatalinaDD
Fix kernel module build for 6.1 kernel in preparation of bookworm upgrade
Why I did it
System health config is missing in few Dell platforms.
How I did it
Added system health monitoring config and its related API's
How to verify it
show system-health summary/detail commands.
Why I did it
Dell S6100 Platform components needs to be updated.
How I did it
Modified platform.json to fix the issue.
How to verify it
Run sonic-mgmt component test and check whether it passes.
- Why I did it
watchdogutil uses platform API watchdog instance to control/query watchdog status. In Nvidia watchdog status, it caches "armed" status in a object member "WatchdogImplBase.armed". This is not working for CLI infrastructure because each CLI will create a new watchdog instance, the status cached in previous instance will totally lose. Consider following commands:
admin@sonic:~$ sudo watchdogutil arm -s 100 =====> watchdog instance1, armed=True
Watchdog armed for 100 seconds
admin@sonic:~$ sudo watchdogutil status ======> watchdog instance2, armed=False
Status: Unarmed
admin@sonic:~$ sudo watchdogutil disarm =======> watchdog instance3, armed=False
Failed to disarm Watchdog
- How I did it
Use sysfs to query watchdog status
- How to verify it
Manual test
Unit test
These devices will not reliabily report the proper devid and vendorid
when reading it is read directly from the pci config space.
It can be read but shouldn't be compared against some fixed value like
the one stored in pcie.yaml.
Since this makes pcied unhappy, the simplest path forward is to just
remove this device from monitoring.
How I did it
Update Yang definition of IN_PORTS and OUT_PORTS to string.
Since we cannot split the string with comma (,) and validate each substring is a valid SONiC port name. The only restriction for them is must be a string.
How to verify it
Verified by building sonic_yang_models-1.0-py3-none-any.whl. While building the target package, unit tests were run and passed.
Build a SONiC image based on 202205 branch and installed on physical DUT. Re try the steps in [Yang] Incorrect definition of IN_PORTS and OUT_PORTS in sonic-acl.yang #16190 and can see below success response:
- Why I did it
The recent change #15685 (comment) removed the db migration for non first reboots.
This is problematic for many deployments which doesn't rely on ZTP and push a custom config_db.json
Port to older branches after #15685 is ported back
- How I did it
Re-introduce the logic to run the db_migrator on non-first boots
- How to verify it
Verified reboot and warm-reboot cases
Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>
#### Why I did it
src/dhcpmon
```
* a3c5381 - (HEAD -> master, origin/master, origin/HEAD) Merge pull request #11 from jcaiMR/dev/jcai_fix_err_log (12 hours ago) [StormLiangMS]
* ab78a31 - Merge branch 'master' into dev/jcai_fix_err_log (4 days ago) [jcaiMR]
* 5314b72 - remove unnessary log message in case too many log output (5 days ago) [jcaiMR]
* 01f4fa7 - fix build issue (5 days ago) [jcaiMR]
* c2fbb34 - fix format issue (5 days ago) [jcaiMR]
* 79b6720 - fix a notification message format issue (6 days ago) [jcaiMR]
```
#### How I did it
#### How to verify it
#### Description for the changelog
#### Why I did it
src/sonic-gnmi
```
* ac94807 - (HEAD -> master, origin/master, origin/HEAD) Support get all with json (#145) (19 hours ago) [ganglv]
```
#### How I did it
#### How to verify it
#### Description for the changelog
- Why I did it
Change Mellanox platform API implementation to use ASIC driver sysfs for the module operational state and status error fields.
- How I did it
Modify the platform/mellanox/mlnx-platform-api/sonic_platform/sfp.py file by change the call of sx_mgmt_phy_module_info_get() SDK API to sysfs
- How to verify it
Simulate the unplug cable event
Check the CLI output
sfputil show presence
sfputil show error-status -hw
Simulate the plug cable event
Repeat 2 step
Signed-off-by: vadymhlushko-mlnx <vadymh@nvidia.com>
Why I did it
Few commands in multiasic platforms when run with the "sudo ip netns exec asic0 " option was taking like 15 mins to get the o/p. This behavior of sudo getting hung was seen by just doing this
jujoseph@svcstr-server-2:~ sudo ip netns exec asic0 bash
jujoseph@svcstr-server-2:~ sudo ls
deally sudo is not needed as we have /bin/ip netns identify present in /etc/sudoers file. Hence removing it
* sonic-buildimage: Add 7060DX5-64S brcm tunnel config
Add bcm_tunnel_term_compatible_mode: 1 support, which allows
Loopback configuration to no longer result in SAI failure
"tunnel terminator add failed with error Feature unavailable"
that caused Orchagent SIGABRT
Signed-off-by: Aaron Payment <aaronp@arista.com>
* sonic-buildimage: Set port config ENABLE:0 in 7060DX5-64S brcm config
Set ENABLE:0 for the front panel ports in the brcm config so that the
ports are default admin down. This change prevents the issue that ports
are able to link up and pass traffic resulting in mac learn events after
SAI create switch and before SAI admin state up. The unexpected mac learn events
resulted in Orch agent crash in PortsOrch init, which occurs after SAI
create switch and before SAI admin state up.
* fix sensors.conf on CatalinaDD
* Add support for two sfp ports
* Add copper 50g tuning to babbagelp on catalina
---------
Signed-off-by: Aaron Payment <aaronp@arista.com>
Co-authored-by: enes.oncu <enes.oncu@arista.com>
Co-authored-by: Boyang Yu <byu@arista.com>
Why I did it
Update the platform_reboot of Nokia Platform IXR-7250E-36x400G to displays the correct reboot-cause history when reboot from supervisor card.
Work item tracking
Microsoft ADO (number only):
How I did it
Modify the platform_reboot script to copy the correct reboo-cause.txt file from NDK to the /host/reboot-cause directory at the down cycle when the reboot is issued from Supervisor (for both reboot right after install a new image and normal reboot)
Signed-off-by: mlok <marty.lok@nokia.com>
It appears that this was initially added to provide the git-retry
command (which doesn't appear to be used today). However, this repo is
now also providing bazel (which is actually used in our build today),
and this command (along with git-retry) expects some vpython3 binary to
be set up/installed.
Rather than going through that, just get rid of this repo.
- Why I did it
Add new breakout modes to be used in PAM4 supported cables
- How I did it
- How to verify it
Verified the 50G per lane breakout modes are applied properly on the switch
Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>
#### Why I did it
HLD implementation: Container Hardening (https://github.com/sonic-net/SONiC/pull/1364)
##### Work item tracking
- Microsoft ADO **(number only)**: 14807420
#### How I did it
Reduce linux capabilities in privileged flag, retain NET_ADMIN capability
#### Why I did it
Reduce docker privilege
This is part of HLD https://github.com/sonic-net/SONiC/pull/1364
#### How I did it
Remove flag --privileged
#### How to verify it
docker exec -it database bash
root@0048b82b460b:/# ip link add dummy0 type dummy
RTNETLINK answers: Operation not permitted
SONiC changes:
1. Support Spectrum4 ASIC FW binary building.
2. Support new SDK sx-obj-desc lib building since new SAI need it.
3. Remove SX_SCEW debian package from Mellanox SDK build since we are no longer using it (we use libxml2 instead).
4. Update SAI, SDK, FW to version 4.6.1020/2012.1020/SAIBuild2305.25.0.3
SDK/FW bug fixes
1. In SPC-1 platforms: Fastboot mode is not operational for Split port with Force mode in 50G speed
SFP modules are kept in disabled state after set LPM (low power mode) on/off for at least 3 minutes.
2. When preforming fast boot from an old SDK version (currently installed) to a newer one (target version), and the system was initially loaded with a new SDK version (past version), and the system has not been wiped, under specific conditions, the fast boot would use the past version's data and may fail.
SDK/FW Features
1. On SN2700 all ports can support y cable by credo
SAI bug Fixes
1. When creating an ACL rule with SAI_ACL_ENTRY_ATTR_FIELD_SRC_IP/SAI_ACL_ENTRY_ATTR_FIELD_DST_IP enabled, and then disabling the field by setting enable=false, a match on L3_type=IPv4 will remain programmed for the rule Issue resolved after the fix
2. Allow the max scale of virtual routers to be configure for SPC-1, SPC-2, SPC-3 when fastboot enable
3. Remove default hash key of SRC_MAC, DST_MAC and ETH_TYPE
SAI features
1. Port init profile
- How I did it
Update SDK/FW/SAI make files
- How to verify it
Run full sonic-mgmt regression on Mellanox platform
Signed-off-by: Kebo Liu <kebol@nvidia.com>
- Why I did it
Update Mellanox MFT tool to version 4.25.0-62
- How I did it
Update the MFT tool make file
- How to verify it
Run full sonic-mgmt regression.
Signed-off-by: Kebo Liu <kebol@nvidia.com>
### Why I did it
Background running lua script may cause redis-server quite busy if batch size is 8192.
If handling time exceeded default 5s, the redis-server will not response to other process and will cause syncd crash.
```
Aug 9 07:46:29.512326 str-s6100-acs-5 INFO database#supervisord: redis 68:M 09 Aug 2023 07:46:29.511 # Lua slow script detected: still in execution after 5186 milliseconds. You can try killing the script using the SCRIPT KILL command. Script SHA1 is: 88270a7c5c90583e56425aca8af8a4b8c39fe757
Aug 9 07:46:29.523716 str-s6100-acs-5 ERR syncd#syncd: :- checkReplyType: Expected to get redis type 5 got type 6, err: BUSY Redis is busy running a script. You can only call SCRIPT KILL or SHUTDOWN NOSAVE.
Aug 9 07:46:29.524818 str-s6100-acs-5 INFO syncd#supervisord: syncd terminate called after throwing an instance of '
Aug 9 07:46:29.525268 str-s6100-acs-5 ERR pmon#CCmisApi: :- checkReplyType: Expected to get redis type 5 got type 6, err: BUSY Redis is busy running a script. You can only call SCRIPT KILL or SHUTDOWN NOSAVE.
Aug 9 07:46:29.526148 str-s6100-acs-5 INFO syncd#supervisord: syncd std::system_error'
Aug 9 07:46:29.528308 str-s6100-acs-5 ERR pmon#psud[32]: :- checkReplyType: Expected to get redis type 5 got type 6, err: BUSY Redis is busy running a script. You can only call SCRIPT KILL or SHUTDOWN NOSAVE.
Aug 9 07:46:29.529048 str-s6100-acs-5 ERR lldp#python3: :- guard: RedisReply catches system_error: command: *2#015#012$3#015#012DEL#015#012$27#015#012LLDP_ENTRY_TABLE:Ethernet37#015#012, reason: BUSY Redis is busy running a script. You can only call SCRIPT KILL or SHUTDOWN NOSAVE.: Input/output error
Aug 9 07:46:29.529720 str-s6100-acs-5 ERR snmp#python3: :- guard: RedisReply catches system_error: command: *2#015#012$7#015#012HGETALL#015#012$28#015#012COUNTERS:oid:0x100000000000a#015#012, reason: BUSY Redis is busy running a script. You can only call SCRIPT KILL or SHUTDOWN NOSAVE.: Input/output error
```
88270a7c5c90583e56425aca8af8a4b8c39fe757 is /usr/share/swss/consumer_state_table_pops.lua
##### Work item tracking
- Microsoft ADO **24741990**:
#### How I did it
Change batch size from 8192 to1024.
#### How to verify it
Run all test cases in sonic-mgmt to verify the system stability.
### Tested branch (Please provide the tested image version)
- [x] 20220531.36
Why I did it
Add PDDF support on following Ufispace platforms with Broadcom ASIC
S9110-32X
S8901-54XC
S7801-54XS
S6301-56ST
How I did it
Add PDDF configuration files, scripts and python files
How to verify it
Run pddf commands and show commands.
Signed-off-by: nonodark <ef67891@yahoo.com.tw>