Set sai_tunnel_underlay_route_mode attribute to fallback to default
route if more specific route is unavailable.
Signed-off-by: Nikola Dancejic <ndancejic@microsoft.com>
This was an ask by Microsoft to provide:
7260 config.bcm file for hardware sku Arista-7260CX3-D92C16 (Named Arista-7260CX3-D96C16).
There are 16 100G uplinks:
Ethernet13-20/1
Ethernet45-52/1
All other ports are breakout to 2 50G ports.
The original ask was for 201811. This is the requested PR for 202012.
How I did it
Copied existing Arista-7260CX3-D108C8 HWSKU and altered the bcm config, port_config.ini, and buffers config files.
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
This is to address an issue where it was observed that SAI operations sometime make take a very long to time complete (over 45ms). It was determined that the ALPM distributed thread was causing this issue.
The fix is to disable this debug thread that has no functional purpose.
Preliminary tests looks fine. BGP neighbors were all up with proper routes programmed
interfaces are all up
Manually ran the fib test cases on 7050CX3 (TD3), TD2, TH, TH2, and TH3 based platforms and
thy all passed.
A new config option `sai_verify_incoming_chksum` was added to control the value of IPV4_INCR_CHECKSUM_ORIGINAL_VALUE_VERIFY in the EGR_FLEX_CONFIG control register (this prevents checksums of 0xffff from being propagated to other devices)
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
Why I did it
The first 4 ports on this dut are breakout ports. They might not always be connected in lab. Mark them as 'RJ45' to skip the SFP check since they are by default disabled.
How to verify it
run platform test_reboot.py
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* Update default cable len to 0m for TD2 (#8298)
* Update sonic-cfggen tests with the correct cable len
Signed-off-by: Neetha John <nejo@microsoft.com>
As part of the buffer reclamation efforts for TD2, setting the default cable len to 0m which means unused ports will have a cable len of 0m.
Why I did it
To align with the changes in Azure/sonic-swss#1830
How to verify it
- With the default cable len set to 0m and the associated changes in swss, CABLE_LENGTH table had '0m' set for unused ports and accordingly more space was reserved for the shared pool
- Cfggen tests passed with the cable len update
This PR only contains backports from master
Fix leak discovered on master, though 202012 is not affected it's better to have the fix (fixes [master] thermalctld leak on Arista devices makes them unreachable when memory is exhausted #7515)
Fix EepromDecoderimplementation in the platform API (fixes syseepromd crashing repeatedly on SONiC.20201231.02 #8263)
Fix Mineral platform definition and configuration
Fix build issues in environments where /proc is not mounted/restricted (fixes PLATFORM=broadcom fails arista "ReloadCauseManagerTest" first time #7800)
Fix some pytest issues
Add sfp-eeprom C API and also mount it in pmon
Signed-off-by: Neetha John <nejo@microsoft.com>
As part of the buffer reclamation efforts for TD2, setting the default cable len to 0m which means unused ports will have a cable len of 0m.
Why I did it
To align with the changes in Azure/sonic-swss#1830
How to verify it
With the default cable len set to 0m and the associated changes in swss, CABLE_LENGTH table had '0m' set for unused ports and accordingly more space was reserved for the shared pool
Signed-off-by: Roman Savchuk <romanx.savchuk@intel.com>
Why I did it
Platform pcie configuration file doesn't exist for x86_64-arista_7170_64c
How I did it
Generate pcie.yml
How to verify it
Started pcie daemon (pcied RUNNING pid 63, uptime 0:00:19)
What I did:
Updated 7260 MMU Profile based on latest MSFT Tier 1 Tomahawk2_MMU_Setting_48x100G_40m_16x100G_300m_v1.0 and
TH2_PGHdrm_MSFT.
How I verify:
Made sure image is up/traffic is flowing/mmu dump looked fine.
SAI qos test need will be updated to support this SKU.
Process pcied failed on Arista-7170-32CD-C32
```
root@sonic:/# supervisorctl
chassis_db_init EXITED Jun 03 08:48 AM
dependent-startup EXITED Jun 03 08:48 AM
ledd RUNNING pid 28, uptime 3:07:49
lm-sensors EXITED Jun 03 08:48 AM
pcied FATAL Exited too quickly (process log may have details)
```
Signed-off-by: Andriy Kokhan <andriyx.kokhan@intel.com>
Why I did it
7050 S4Q31 mmu configuration is missing ALPM configurations, causing not enough memory reserved for routes. Orchagent crashes on a nightly testbed with 6400 route entries.
How I did it
Add the missing ALPM configurations.
How to verify it
Load the configuration on testbed and verified new configuration exists and no more crash.
Signed-off-by: Ying Xie ying.xie@microsoft.com
This PR contains the following changes
Original Arista-7050-QX-32S sku (32x40G ports) has been renamed to Arista-7050QX32S-Q32
Arista-7050-QX-32S is symlinked to Arista-7050QX-32S-S4Q31 (4x10G, 31x40G ports)
Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
Arista-7260CX3-Q64 is missing T1 MMU configuration.
How I did it
Define T1 MMU configuration for Arista-7260CX3-Q64.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
PG profile settings need to be aligned with Arista-7050-QX-32S
How I did it
Copy over the current settings from Arista-7050-QX-32S and define params for 10G and 1G speeds as well
Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
Need proper MMU and Qos settings for Arista-7050QX-32S-S4Q31
How I did it
Updated the settings based on Arista-7050-QX-32S
* [202012] Add SOC property to enable AN/LT on some platforms
Why I did it
To enable autonegotiation/link training on some Broadcom-based platforms (Arista 7060CX, 7260CX3, 7050cx3, Celestica DX010)
How I did it
Add appropriate SOC property for enabling the feature to the Broadcom config files of appropriate platforms
Also convert line endings to UNIX format for one Celestica file
* Add 'phy_an_lt_msft' to BCM config file permitted list
Set hierarchical ecmp level to 2 instead of 3. Based on CS00011833367, ecmp level must be set to 2.
This is already handled for TH2 platforms. Change is required only for TD3
Co-authored-by: Ubuntu <prsunny@prince-vm.vzw1i4tqyeburcdz5lrgulxi2c.yx.internal.cloudapp.net>
* 7260cx3 DualToR config.bcm support based on DualToR setting in device metadata at boot time.
For HWSKU Arista-7260CX3-C64 the MMU setting SOC for T0/T1 is also combined into the config.bcm.j2 logic so use just one config file and adding delta based on Switch Roles.
As booting on DCS-7060DX4-32 would use the default sku of DCS-7060PX4-32 which is not compatible,
thus move some files around to properly separate the configurations that are device specific.
Signed-off-by: Samuel Angebault <staphylo@arista.com>
- Why I did it
The pcie configuration file location is under plugin directory not under platform directory.
#6437
- How I did it
Move all pcie.yaml configuration file from plugin to platform directory.
Remove unnecessary timer to start pcie-check.service
Move pcie-check.service to sonic-host-services
- How to verify it
Verify on the device
- Add support for `DCS-7050SX3-48YC8` and `DCS-7050SX3-48C8` platform
- Add support for more variants of `DCS-7280CR3-32[PD]4`
- Add Supervisor to Linecard consutil support
- Complete Watchdog platform API support
- Fix some PSU behavior on `DCS-7050QX-32` and `DCS-7060CX-32S`
- Fix SEU management on `DCS-7060CX-32S`
- Allow kernel modules to build up to linux 5.10
- Rename led color `orange` to `amber`
- Miscellaneous fixes
Port_config update for hwsku 7050CX3-32S-C3 - add two 10G ports.
This change is added to fix issue of "PortsOrch initialization failure" seen by previous removal of these 10G ports.
Tested on the device with new minigraph, and the PortsOrch initialization failure is not seen.
port_config.ini for HWSKU Arista-7050CX3-32S-C32 has missing speed column and duplicated lanes.
The incorrect speed causes issues in Orchagent RESTARTCHECK as the below task remains as the remaining item during swss shutdown.
Prevent system-healthd from service from failing at boot time due to missing configuration.
Also adds basic support for healthd.
The following caveat exists with this placeholder configuration:
- No PSU monitoring (sensors/fans)
- No ASIC temperature monitoring
platform.json is needed for sonic-mgmt testing. Also in the future it will be used as part of dynamic port breakout.
Also removed the folder symlink for BlackhawkDD because it has a different platform.json than BlackhawkO.
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
Current support for the 7060PX4-32 and 7060DX4 was broken.
With this change, ports are now linking fine.
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
Rename chip name dps1900-i2c-X-58 to pmbus-i2c-X-58 in sensors.conf for Arista 7170 due to latest updates for Arista driver submodules #5686. After these updates adapter dps1900 was renamed and sensors.conf file is not applied properly. Issue was observed started from BFN SONiC image 16.
Signed-off-by: Nazar Tkachuk <nazarx.tkachuk@intel.com>
Submodule updates include the following commits:
* src/sonic-utilities 9dc58ea...f9eb739 (18):
> Remove unnecessary calls to str.encode() now that the package is Python 3; Fix deprecation warning (#1260)
> [generate_dump] Ignoring file/directory not found Errors (#1201)
> Fixed porstat rate and util issues (#1140)
> fix error: interface counters is mismatch after warm-reboot (#1099)
> Remove unnecessary calls to str.decode() now that the package is Python 3 (#1255)
> [acl-loader] Make list sorting compliant with Python 3 (#1257)
> Replace hard-coded fast-reboot with variable. And some typo corrections (#1254)
> [configlet][portconfig] Remove calls to dict.has_key() which is not available in Python 3 (#1247)
> Remove unnecessary conversions to list() and calls to dict.keys() (#1243)
> Clean up LGTM alerts (#1239)
> Add 'requests' as install dependency in setup.py (#1240)
> Convert to Python 3 (#1128)
> Fix mock SonicV2Connector in python3: use decode_responses mode so caller code will be the same as python2 (#1238)
> [tests] Do not trim from PATH if we did not append to it; Clean up/fix shebangs in scripts (#1233)
> Updates to bgp config and show commands with BGP_INTERNAL_NEIGHBOR table (#1224)
> [cli]: NAT show commands newline issue after migrated to Python3 (#1204)
> [doc]: Update Command-Reference.md (#1231)
> Added 'import sys' in feature.py file (#1232)
* src/sonic-py-swsssdk 9d9f0c6...1664be9 (2):
> Fix: no need to decode() after redis client scan, so it will work for both python2 and python3 (#96)
> FieldValueMap `contains`(`in`) will also work when migrated to libswsscommon(C++ with SWIG wrapper) (#94)
- Also fix Python 3-related issues:
- Use integer (floor) division in config_samples.py (sonic-config-engine)
- Replace print statement with print function in eeprom.py plugin for x86_64-kvm_x86_64-r0 platform
- Update all platform plugins to be compatible with both Python 2 and Python 3
- Remove shebangs from plugins files which are not intended to be executable
- Replace tabs with spaces in Python plugin files and fix alignment, because Python 3 is more strict
- Remove trailing whitespace from plugins files
Need A mmu configuration to get the device going without generating lots of warnings.
Similar to dummy MMU configuration for Arista-7050CX3-32S-C32, this configuration will need to be updated with correct numbers. This MMU configuration is copied from 7060 comparable hwsku.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
Treat devices that are ToRRouters (ToRRouters and BackEndToRRouters) the same when rendering templates
Except for BackEndToRRouters belonging to a storage cluster, since these devices have extra sub-interfaces created
Treat devices that are LeafRouters (LeafRouters and BackEndLeafRouters) the same when rendering templates
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
- Why I did it
On Arista-7050CX3-32S-C32, there are constant stream of errors like following.
Nov 3 21:56:24.415190 str2-7050cx3-acs-06 NOTICE swss#orchagent: :- registerInWdDb: No lossless TC found on port Ethernet68
Which causes:
loganalyzer to claim test failed.
leaving the system without MMU configuration. Which couldn't be good for any IO test.
- How I did it
Added these MMU configuraions are copied from another platform and guaranteed to be incorrect for hwsku Arista-7050CX3-32S-C32.
Adding them so that we have A MMU configuration and the system won't throw a whole bunch of errors and leave MMU unconfigured. The correct MMU configuration will come later.
This configuration is definitely not suitable for testing system performance or QoS behavior.
Signed-off-by: Ying Xie ying.xie@microsoft.com
- How to verify it
Test will have chance to pass. Ran a few test that would fail otherwise.
We don't need a custom platform reboot on Clearwater2(Ms). They are expected to be rebooted via a normal linux soft reboot.
Remove symlink to the arista common platform reboot for those 2 platforms.
- Enable thermalctld support for our platforms
- Fix Chassis.get_num_sfp which had an off by one
- Implement read_eeprom and write_eeprom in SfpBase
- Refactor of Psus and PsuSlots. Psus they are now detected and metadata reported
- Improvements to modular support
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>