* [device/mellanox/x86_64-mlnx_msn2700-r0/plugins/sfputil.py]
purpose and restrictions
1. reading eeprom via ethtool.
2. avoid changing common codes shared by all the manufacture (sonic-platform-common), contrain all the modifications with Mellanox-specific code.
current implementation
A new class based on SfpUtilBase and a new method _read_eeprom_specific_bytes_via_ethtool have been introduced in order to change the way the eprom DOM data is read. Typically the best practice to do this kind of thing is to contrain the modification within the function which execute reading operations only and keep other stuffs (especially the interface) untouched. However, this can hardly be achieved since the original reading function takes the file object as input parameter to represent the port. It is done by having the file object to point to /var/run/hwmanagement files, which will not be maintained in the future. As a result, a new interface has to be introduced with a port number/name as input parameter in order to get rid of the dependency on the those files:
_read_eeprom_specific_bytes_via_ethtool
Since the interface changed, all methods that call the interface should also be overwritten in order to call the new interface, including:
_read_eeprom_devid
get_transceiver_info_dict
get_transceiver_dom_info_dict
Only interface used to read eeprom DOM has been replaced and the main logic has not been changed except the following mentioned.
1. reading DOM data for sfp port, which is implementioned in get_transceiver_dom_info_dict. In this case a "calibration" should be firstly read from eeprom before other values like temperature, voltage, rx/tx power, can be parsed. However, this has been ignored in the original code, resulting in that the data cann't be parsed.
2. In the original implemention the data area containing the data are read from DOM separatedly in order to avoid read uncessary data and achieve a better performance. Having used ethtool to read DOM data, the performance gap between reading all the area and reading the spot data separatedly has been narrowed to almost zero. To make the code neat and readable, we change the way to read this data.
* [sfputil] Returns dict with all data set to N/A for ports without dom support
Currently, the way in which dom data is read has been changed from using sysfs to using ethtool.
The ethtool returns None for ports without dom support, resulting in None being returned. However, this fails xcvrd to add the TRANSCEIVER_DOM_SENSOR table entry of associated port to CONFIG_DB and then causes SNMP fail.
To address this issue a default dict is initialized with all data set to 'N/A' and is returned is the above case.
BTW, in the original implementation which sysfs is used to read dom data, even though non-None data is returned for ports without dom support, it does not contain valid data. This can result in wrong data in TRANSCEIVER_DOM_SENSOR table.
* [sfputil]
removing unnecessary empty lines
removing redundent code
replacing hardcoding strings/numbers with predefined const variables
* Add new device accton_as5812_54x.
Signed-off-by: roy_lee <roy_lee@accton.com>
* Rename 5812's config.bcm.
Signed-off-by: roy_lee <roy_lee@accton.com>
* Change fan module to support lm-sensors.
Validate for thermal policy.
Signed-off-by: roy_lee <roy_lee@accton.com>
* Add bask reset and lpmode control of 6 QSFP ports.
Signed-off-by: roy_lee <roy_lee@accton.com>
* Get currect duty of fan for comparing. Instead of by stored duty from previous iteration.
Signed-off-by: roy_lee <roy_lee@accton.com>
* Roll back the mistakes to update mellanox submodules.
Signed-off-by: roy_lee <roy_lee@accton.com>
* Rollback for misoperation on submodule platform/p4/SAI-P4-BM.
Signed-off-by: roy_lee <roy_lee@accton.com>
* Change indexes of ports to start from 1, as them on the front panel.
Add low-power mode control of the transciever's eeprom, follows SFF-8436.
Signed-off-by: roy_lee <roy_lee@accton.com>
This commit adds new code and JAON file to support PFC
and MMU setting for PFC feature on z9264f-Q64 (40G) T0
and T1 support. The buffers_defaults_t0.json and
buffers_defaults_t1.json file has the recommended values
for T0 and T1 configuration.
Unit tested and verified by running JSON file and checking
the hardware registers and table in broadcom. THe settings
in hardware are reflecting the JSON values.
Signed-off-by: Harish Venkatraman <harish_venkatraman@dell.com>
* [logrotate] Decrease frequency to every 10 minutes; kill any lingering logrotate processes
* [logrotate] Delete all *.1.gz files as firstaction; Remove note about init-system-helpers < 1.47 workaround
However, continue to send SIGHUP directly to rsyslogd process
because 'service rsyslog rotate' still doesn't work properly with
init-system-helpers version 1.48
[vlan] Add pytest case to add max vlan. (#881)
[badge]: add vs build badge (#898)
Fix PFC watchdog not getting lossless TC (#876)
[vstest]: skip test_AddMaxVlan as it takes almost two hours to finish (#901)
[test]: Enforce fake port-channel interfaces carrier up
Signed-off-by: Shu0T1an ChenG <shuche@microsoft.com>
Since we move to FRR, we need to connect FRR with fpmsyncd via FPM.
Adding static routes is also required.
Signed-off-by: Shu0T1an ChenG <shuche@microsoft.com>
* Add boot0 support for the 7280CR3
* Add platform and plugins for 7280CR3
* Add port config for 7280CR3
* Add platform_reboot for 7280CR3
* Add support for 7280CR3-32D4 based on the 7280CR3-32P4
* Update arista driver submodules
- Introduce new 7280CR3-32P4
- Improve to the led plugin for OSFP
This commit adds new code and JSON file to support PFC and
broadcom recommended MMU setting for PFC feaure on z9264f
(100G) T1 support. The buffers_defaults_t1.json file has
the broadcom recommended values for T1 configuration.
Unit tested and verified by running the JSON file and checking
the hardware registers and table in broadcom. The settings in
the hardware is reflecting the broadcom recommended values.
Signed-off-by: Harish Venkatraman <harish_venkatraman@dell.com>