7790a74d90
- Why I did it Support shared headroom pool Signed-off-by: Stephen Sun stephens@nvidia.com - How I did it Port configurations for SKUs based on 2700/3800 platform from 201911 For SN3800 platform: C64: 32 100G down links and 32 100G up links. D112C8: 112 50G down links and 8 100G up links. D24C52: 24 50G down links, 20 100G down links, and 32 100G up links. D28C50: 28 50G down links, 18 100G down links, and 32 100G up links. For SN2700 platform: D48C8: 48 50G down links and 8 100G up links C32: 16 100G downlinks and 16 100G uplinks Add configuration for Mellanox-SN4600C-D112C8 112 50G down links and 8 100G up links. - How to verify it Run regression test.
18 lines
746 B
INI
18 lines
746 B
INI
# PG lossless profiles.
|
|
# speed cable size xon xoff threshold
|
|
10000 5m 19456 19456 24576 0
|
|
25000 5m 19456 19456 24576 0
|
|
40000 5m 19456 19456 24576 0
|
|
50000 5m 19456 19456 24576 0
|
|
100000 5m 19456 19456 25600 0
|
|
10000 40m 19456 19456 24576 0
|
|
25000 40m 19456 19456 26624 0
|
|
40000 40m 19456 19456 27648 0
|
|
50000 40m 19456 19456 28672 0
|
|
100000 40m 19456 19456 32768 0
|
|
10000 300m 19456 19456 30720 0
|
|
25000 300m 19456 19456 39936 0
|
|
40000 300m 19456 19456 49152 0
|
|
50000 300m 19456 19456 55296 0
|
|
100000 300m 19456 19456 86016 0
|