- Why I did it
Support shared headroom pool
Signed-off-by: Stephen Sun stephens@nvidia.com
- How I did it
Port configurations for SKUs based on 2700/3800 platform from 201911
For SN3800 platform:
C64: 32 100G down links and 32 100G up links.
D112C8: 112 50G down links and 8 100G up links.
D24C52: 24 50G down links, 20 100G down links, and 32 100G up links.
D28C50: 28 50G down links, 18 100G down links, and 32 100G up links.
For SN2700 platform:
D48C8: 48 50G down links and 8 100G up links
C32: 16 100G downlinks and 16 100G uplinks
Add configuration for Mellanox-SN4600C-D112C8
112 50G down links and 8 100G up links.
- How to verify it
Run regression test.
Calculate pool size in t1 as 24 * downlink port + 8 * uplink port
- Take both port and peer MTU into account when calculating headroom
- Worst case factor is decreased to 50%
- Mellanox-SN2700-C28D8 t0, assume 48 * 50G/5m + 8 * 100G/40m ports
- Mellanox-SN2700 (C32)
- t0: 16 * 100G/5m + 16 * 100G/40m
- t1: 16 * 100G/40m + 16 * 100G/300m
Signed-off-by: Stephen Sun <stephens@mellanox.com>
Co-authored-by: Stephen Sun <stephens@mellanox.com>
Add related files to the device folder:
buffer config templates
pg lookup profile
port_config.ini
sai profile
sensor conf
plugins