Why I did it
Added Support for Dell EMC S5212f platform
How I did it
Implemented the support for Dell EMC S5212f platform
Platform: x86_64-dellemc_s5212f_c3538-r0
HwSKU: DellEMC-S5212f-P-25G
ASIC: broadcom
ASIC Count: 1
How to verify it
Verified the show command outputs
#### Why I did it
Add platform_asic file to each platform folder in sonic-device-data package. The file content will be used as the ground truth of mapping from PLATFORM_STRING to switch ASIC family.
One use case of the mapping is to prevent installing a wrong image, which targets for other ASIC platforms. For example, currently we have several ONIE images naming as sonic-*.bin, it's easy to mistakenly install the wrong image. With this mapping built into image, we could fetch the ONIE platform string, and figure out which ASIC it is using, and check we are installing the correct image.
After this PR merged, each platform vendor has to add one mandatory text file `device/PLATFORM_VENDOR/PLATFORM_STRING/platform_asic`, with the content of the platform's switch ASIC family.
I will update https://github.com/Azure/SONiC/wiki/Porting-Guide after this PR is merged.
You can get a list of the ASIC platforms by `ls -b platform | cat`. Currently the options are
```
barefoot
broadcom
cavium
centec
centec-arm64
generic
innovium
marvell
marvell-arm64
marvell-armhf
mellanox
nephos
p4
vs
```
Also support
```
broadcom-dnx
```
#### How I did it
#### How to verify it
Test one image on DUT. And check the folders under `/usr/share/sonic/device`
Depends on Azure/sonic-utilities#1626
Depends on Azure/sonic-swss#1754
QOS tables in config db used ABNF format i.e "[TABLE_NAME|name] to refer fieldvalue to other qos tables.
Example:
Config DB:
"Ethernet92|3": {
"scheduler": "[SCHEDULER|scheduler.1]",
"wred_profile": "[WRED_PROFILE|AZURE_LOSSLESS]"
},
"Ethernet0|0": {
"profile": "[BUFFER_PROFILE|ingress_lossy_profile]"
},
"Ethernet0": {
"dscp_to_tc_map": "[DSCP_TO_TC_MAP|AZURE]",
"pfc_enable": "3,4",
"pfc_to_queue_map": "[MAP_PFC_PRIORITY_TO_QUEUE|AZURE]",
"tc_to_pg_map": "[TC_TO_PRIORITY_GROUP_MAP|AZURE]",
"tc_to_queue_map": "[TC_TO_QUEUE_MAP|AZURE]"
},
This format is not consistent with other DB schema followed in sonic.
And also this reference in DB is not required, This is taken care by YANG "leafref".
Removed this format from all platform files to consistent with other sonic db schema.
Example:
"Ethernet92|3": {
"scheduler": "scheduler.1",
"wred_profile": "AZURE_LOSSLESS"
},
Dependent pull requests:
#7752 - To modify platfrom files
#7281 - Yang model
Azure/sonic-utilities#1626 - DB migration
Azure/sonic-swss#1754 - swss change to remove ABNF format
Why I did it
Added support for the device S5224F
How I did it
Implemented the support for the platform S5224F
Switch Vendor: DellEMC
Switch SKU: S5224F-ON
ASIC Vendor: Broadcom
SONiC Image: sonic-broadcom.bin
How to verify it
Verified the show platform/interface commands
Why I did it
Added support for the device N3248PXE
How I did it
Implemented the support for the platform N3248PXE
n3248pxe_unit_test_log.txt
Switch Vendor: DellEMC
* Switch SKU: N3248PXE
* ASIC Vendor: Broadcom
* SONiC Image: sonic-broadcom.bin
How to verify it
Verified the show platform commands
Why I did it
Added support for the device N3248TE
How I did it
Implemented the support for the platform N3248TE
Switch Vendor: DellEMC
Switch SKU: N3248TE
ASIC Vendor: Broadcom
SONiC Image: sonic-broadcom.bin
How to verify it
Verified the show platform commands
Co-authored-by: Arun LK <Arun_L_K@dell.com>
Why I did it
Support for show system-health command in s5232f
How I did it
Added the configuration, API changes to support system health
How to verify it
Execute "show system-health summary/detail/monitor-list" CLI.
* Update default cable len to 0m for TD2 (#8298)
* Update sonic-cfggen tests with the correct cable len
Signed-off-by: Neetha John <nejo@microsoft.com>
As part of the buffer reclamation efforts for TD2, setting the default cable len to 0m which means unused ports will have a cable len of 0m.
Why I did it
To align with the changes in Azure/sonic-swss#1830
How to verify it
- With the default cable len set to 0m and the associated changes in swss, CABLE_LENGTH table had '0m' set for unused ports and accordingly more space was reserved for the shared pool
- Cfggen tests passed with the cable len update
Why I did it
To support "pcied" and "pcieutil" commands in DellEMC Z9332f.
How I did it
Add 'pcie.yaml' in device/dell/[PLATFORM]/ directory.
How to verify it
Execute "pcieutil check" command.
Logs: UT_logs.txt
Signed-off-by: Neetha John <nejo@microsoft.com>
As part of the buffer reclamation efforts for TD2, setting the default cable len to 0m which means unused ports will have a cable len of 0m.
Why I did it
To align with the changes in Azure/sonic-swss#1830
How to verify it
With the default cable len set to 0m and the associated changes in swss, CABLE_LENGTH table had '0m' set for unused ports and accordingly more space was reserved for the shared pool
Why I did it
To determine the revision of the pcie.yaml to be used based on BIOS version in DellEMC S6100 platform.
Depends on: Azure/sonic-platform-common#195
How I did it
Added two revisions of pcie.yaml pcie_1.yaml and pcie_2.yaml
Included a platform-specific Pcie class to provide the revision of the pcie.yaml to be used by pcieutil/pcied.
How to verify it
Execute pcieutil check (Azure/sonic-utilities#1672) command and verify the list of PCIe devices displayed.
Logs: UT_logs.txt
#### Why I did it
Support API 2.0 for S5248F platform
#### How I did it
Making changes to S5248F platform specific directory
Co-authored-by: Arun LK <Arun_L_K@dell.com>
Why I did it
MMU configuration for DellEMC Z9332 systems in T0/T1 topology
How I did it
Updated config.bcm, QoS/Buffer pool and lossy/lossless profile settings
How to verify it
Verified that Dell systems are booting up fine and basic test cases passing.
#### Why I did it
- After [sonic-linux-kernel#177](https://github.com/Azure/sonic-linux-kernel/pull/177) changes, the I2C mux channels of Baseboard and Switchboard CPLDs are moved from i2c-4 and i2c-5 to i2c-36 and i2c-37 respectively.
- This caused QSFP driver initialization of i2c-36 to i2c-41 to fail causing the ports from Ethernet208 to Ethernet248 fail.
#### How I did it
- The fix to this problem is to change the order of QSFP driver initialization to I2C mux channels.
- Instead of the order i2c-10 to i2c-41, the order i2c-4 to i2c-35 is being utilized.
- Also, need to change the i2c-mux-channel number for Baseboard CPLD and switchboard CPLD in scripts to access them.
#### Why I did it
- xcvrd crash was seen in latest 201811 images.
- For Dell S6100,API 2.0 uses poll mode while 1.0 was still using interrupt mode.
#### How I did it
- Modified get_transceiver_change_event in 1.0 to poll mode.
Incorporate the below changes in DellEMC Z9332F platform:
- Implemented watchdog platform API support
- Implement ‘get_position_in_parent’, ‘is_replaceable’ methods for all device types
- Change return type of SFP methods to match specification in sonic_platform_common/sfp_base.py
- Added platform.json file in device directory.
Co-authored-by: V P Subramaniam <Subramaniam_Vellalap@dell.com>
The S6000 devices, the cold reboot is abrupt and it is likely to cause issues which will cause the device to land into EFI shell. Hence the platform reboot will happen after graceful unmount of all the filesystems as in S6100.
Moved the platform_reboot to platform_reboot_override and hooked it to the systemd shutdown services as in S6100
- Why I did it
The pcie configuration file location is under plugin directory not under platform directory.
#6437
- How I did it
Move all pcie.yaml configuration file from plugin to platform directory.
Remove unnecessary timer to start pcie-check.service
Move pcie-check.service to sonic-host-services
- How to verify it
Verify on the device
**- Why I did it**
PR https://github.com/Azure/sonic-platform-common/pull/102 modified the name of the SFF-8436 (QSFP) method to align the method name between all drivers, renaming it from `parse_qsfp_dom_capability` to `parse_dom_capability`. Once the submodule was updated, the callers using the old nomenclature broke. This PR updates all callers to use the new naming convention.
**- How I did it**
Update the name of the function globally for all calls into the SFF-8436 driver.
Note that the QSFP-DD driver still uses the old nomenclature and should be modified similarly. I will open a PR to handle this separately.
**- Why I did it**
To incorporate the below changes in DellEMC S6100, S6000 platforms.
- S6100, S6000:
- Enable 'thermalctld'
- Implement DeviceBase methods (presence, status, model, serial) for Fantray and Component
- Implement ‘get_position_in_parent’, ‘is_replaceable’ methods for all device types
- Implement ‘get_status’ method for Fantray
- Implement ‘get_temperature’, ‘get_temperature_high_threshold’, ‘get_voltage_high_threshold’, ‘get_voltage_low_threshold’ methods for PSU
- Implement ‘get_status_led’, ‘set_status_led’ methods for Chassis
- SFP:
- Make EEPROM read both Python2 and Python3 compatible
- Fix ‘get_tx_disable_channel’ method’s return type
- Implement ‘tx_disable’, ‘tx_disable_channel’ and ‘set_power_override’ methods
- S6000:
- Move PSU thermal sensors from Chassis to respective PSU
- Make available the data of both Fans present in each Fantray
**- How I did it**
- Remove 'skip_thermalctld:true' in pmon_daemon_control.json
- Implement the platform API methods in the respective device files
- Use `bytearray` for data read from transceiver EEPROM
- Change return type of 'get_tx_disable_channel' to match specification in sonic_platform_common/sfp_base.py