#### Why I did it
- Adapt config/show CLI commands to support DHCPv6 relay
- Support multiple dhcp servers assignment in one command
- Fix IP validation
- Adapt UT and add new UT cases
#### How I did it
- Modify config/show dhcp relay files
- Modify config/show UT files
#### How to verify it
This PR has a dependency on PR https://github.com/Azure/sonic-utilities/pull/1717
Build an image with the dependent PR and this PR
Use config/show DHCPv6 relay commands.
The unit test failure was due to missing bgp graceful restart select
defer time configuration in voq_chassis.conf. Modified sample output
data file voq_chassis.conf to include this configuration.
Signed-off-by: vedganes <vedavinayagam.ganesan@nokia.com>
*Edited platform.json for 4600 & 4600C
*Edited hwsku.json and port_config.ini files for all the SKU's present under these platforms
Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>
Why I did it
Pcied running by python 2.
How I did it
dropped python2 support and add python3 support for pcied in file docker-pmon.supervisord.conf.j2
How to verify it
docker exec pmon supervisorctl status
- Why I did it
New release of MFT has the following changelog / RN
Fixed an issue that resulted in getting MVPD read errors from the mlxfwmanager during fast reboot.
Fixed mlxuptime sometimes generating a time less than previous due the wrong frequency calculation
- How I did it
Update makefile pointer to new version.
- How to verify it
Manually tested on all Mellanox platforms.
*To run VNET route consistency check periodically.
*For any failure, the monit will raise alert based on return code.
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
- Why I did it
The MSN4410 platform was missing 2x100G and 4x50G supported breakout modes in platform.json
- How I did it
Added the aforementioned breakout modes to platform.json
- How to verify it
Run show interface breakout on a MSN4410 and verify that 2x100G and 4x50G are listed in the supported breakout modes for ports 1-24.
This change introduces 3 columns in the port_config.ini file.
These are coreId, corePortId and numVoq.
The ports for inband and recirc were also renamed properly.
Why I did it
Support Nokia ixr7250E IMM and Supervisor cards
How I did it
Added modules x86_64-nokia_ixr7250e_sup-r0 and x86_64-nokia_ixr7250e_36x400g-r0 ../device/nokia directory.
Modified the platform/broadcom/one-image.mk to include NOKIA_IXR7250_PLATFORM_MODULE
Modified the platform/broadcom/rule.mk to include the platform-module-nokia.mk
Enable fib_multipath_use_neigh for v4
https://www.kernel.org/doc/Documentation/networking/ip-sysctl.txt
Why I did:
This is helpful if the neighbor are not directly connected then Kernel forward to unreachable neighbor option. With this option forwarding using neighbor state to be valid.
with state of tdport from previous warm-reboot.
In case LAG was down before reboot, lacp->wr is not cleared.
In lacp_event_watch_port_flush_data we incremented nr_of_tdports and add
tdport to lacp->wr.state. In case lacp->wr.state already had this tdport
we do not set new state for tdport but appened a new item in
lacp->wr.state. In case we preformed warm-reboot and PortChannel member
was down, after reboot PortChannel member became up next warm-reboot
will initialize teamd with PortChannel member in down state.
Fix this issue by calling stop_wr_mode() when LAG was down. This was probably intended but missed.
#### Why I did it
To fix an issue seen in warm-reboot-sad test cases.
#### How I did it
I fixed it in SONiC libteam patch that adds warm-reboot support. Details in commit description.
#### How to verify it
Run warm-reboot-sad test on t0-56 topology.
Fix for sonic-cfggen exception during platform string read during fresh install and start of sonic in multi asic, /var/run/redisX/ is created after database docker is started.
#### Why I did it
Use a predefined variable to get vendor information when the swss docker container is created
#### How I did it
Use `{{ sonic_asic_platform }}` instead of `$SONIC_CFGGEN -y /etc/sonic/sonic_version.yml -v asic_type`
#### How to verify it
Manually test.
#### Why I did it
The values of the syseeprom were not valid
#### How I did it
I took the correct hexdump values from a real switch and created this hex file again
#### How to verify it
decode-syseeprom will display the new values
Master/202012 image size grew quite a bit. 3.7G harddrive can no longer hold one image and safely upgrade to another image. Every bit of harddrive space is precious to save now.
Also sh syntax seemingly changed, [ condition ] && action was a legit syntax in 201911 branch but it is an error when condition not met with 202012 or later images. Change the syntax to if statement to avoid the issue.
Signed-off-by: Ying Xie ying.xie@microsoft.com
Deliver sfputil support for sfputil show eeprom and sfputil reset along with some component test case fixes
Co-authored-by: Carl Keene <keene@nokia.com>
Fix#7968
Issue is detected on SONiC.20201231.11
In test_static_route.py::test_static_route_ecmp static routes are configured, but neighbors are not resolved after config reload even after 10 minutes.
It looks like the arp_update script is starting to ping when Vlan1000 is not fully configured.
When issue is reproduced, stuck ping6 process is observed in swss container :
USER PID %CPU %MEM VSZ RSS TTY STAT START TIME COMMAND
root 180 0.1 0.0 6296 1272 pts/0 S 17:03 0:03 ping6 -I Vlan1000 -n -q -i 0 -c 1 -W 0 ff02::1
And when arp_update script successfully resolves neighbors, we observe sleep 300 instead of ping process
* add hwsku.json for the Nokia-7215
* added required default_brkout_mode to hwsku as its not optional
* remove tabs from the file so spacing consistent
Co-authored-by: Carl Keene <keene@nokia.com>
#### Why I did it
hostcfgd is starting at the same time as 'create_switch' method is called on orchagent process.
This introduce a degradation on the function execution time which eventually cause the fast-boot flow and a boot scenarion in general to run slower (~6 seconds).
This change will delay the start time of this daemon.
The aaastatsd will delay as well since it has a dependency on hostcfgd, so it is required to delay both.
90 seconds determined as the maximum allowed downtime for control plane to come back up on fast-boot flow.
#### How I did it
Add two timers for hostcfgd and aaastatsd services in order to delay the startup of these services.
#### How to verify it
Install an image with this change and observe the daemons start 90 seconds after the system boot.
Why I did it
fix the dx010 system eeprom unavailable issue
How I did it
enable the i2c slave 30ms timeout mechanism
How to verify it
i2cstress test in DX010 iSMT controller bus
Co-authored-by: nicwu-cel <nicwu@celestica.com>
enable automated test suites to selectively run relevant tests ( or not run tests ) based upon a new port_type identifier in hwsku.json
How I did it
Modified the valid optional fields in validity check for hwsku.json per recommendation from Joe in
https://github.com/Azure/sonic-mgmt/pull/2654/files
Co-authored-by: Carl Keene <keene@nokia.com>
Signed-off-by: Rajkumar Pennadam Ramamoorthy rpennadamram@marvell.com
Why I did it
Install sonic image from ONIE. Once system is up, execute "config reload" command.
Root cause is that "determine-reboot-cause.service" was in failed state.
root@sonic:/host/reboot-cause# systemctl list-units --failed
UNIT LOAD ACTIVE SUB DESCRIPTION
● determine-reboot-cause.service loaded failed failed Reboot cause determination service
How I did it
Fixed the issue by setting default reason to "REBOOT_CAUSE_UNKNOWN" instead of "None".
How to verify it
Check " determine-reboot-cause.service' loaded successfully post image installation from ONIE.
Verify "reboot-cause.txt" file is created and config reload succeeds.
#### Why I did it
New SN410 A1 system has a different sensor layout with A0 system, needs a new sensor conf file to support it.
#### How I did it
Since the SN4410 A1 system use exactly the same sensor layout as the SN4700 A1 system, so add a symbol link linking to the SN4700 A1 sensor conf file to reuse.
#### How to verify it
Run sensor test against the SN4410 A1 system;
Run platform related regression test against the SN4410 A1 system
#### Why I did it
* `arp_update` fails to ping those neighbors over vlan sub interfaces.
#### How I did it
* modify `arp_update_vars.j2` to get vlan sub interfaces with ipv6 addresses assigned.
* modify `arp_update` to send ipv6 pings over those retrieved vlan sub interfaces.
Signed-off-by: Longxiang Lyu <lolv@microsoft.com>
1d3a810 [python coverage] fix result color bar (#202)
3f7b359 Add a template function that returns list of asics on module (#185)
abc2709 Fix decode error when parsing EEPROM fields (#199)
789b41e Load interval from thermal_policy.json (#178)
540ed1c Fix Xcvrd crash due to invalid key access in type_of_media_interface, host_electrical_interface, connector_dict (#206)
716caf8 Unifying the platform api for get_pcie_aer_stats with PcieBase (#197)
Update sonic-utilities with following commit
3f3974e [show priority-group drop counters] Add user info output when user want to check PG counters and polling are disabled (#1678)
16606de Global and Interface commands for IPv6 Link local address enhancements (#1159)
0dcb2b6 Open record file in append mode (#1845)
03ce2ee [vnet/vxlan] Add support of multiple mappers for the VxLAN tunnel (#1843)
c5e90ab VOQ: Nexthop for remote VOQ LC should be created on inband OIF. (#1823)
834c5c8 Td2: Reclaim buffer from unused ports (#1830)
a5ad55c [Dynamic Buffer Calc] Bug fix: Don't create lossless buffer profile for active ports without speed configured (#1822)
f50368f [cfgmgr] Update Makefile.am to consume lib zmq (#1865)
Use DOCKER_HOST. Every client including docker command and python docker API uses this environment variable to connect to dockerd.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
* Update default cable len to 0m for TD2 (#8298)
* Update sonic-cfggen tests with the correct cable len
Signed-off-by: Neetha John <nejo@microsoft.com>
As part of the buffer reclamation efforts for TD2, setting the default cable len to 0m which means unused ports will have a cable len of 0m.
Why I did it
To align with the changes in Azure/sonic-swss#1830
How to verify it
- With the default cable len set to 0m and the associated changes in swss, CABLE_LENGTH table had '0m' set for unused ports and accordingly more space was reserved for the shared pool
- Cfggen tests passed with the cable len update
Why I did it
To support "pcied" and "pcieutil" commands in DellEMC Z9332f.
How I did it
Add 'pcie.yaml' in device/dell/[PLATFORM]/ directory.
How to verify it
Execute "pcieutil check" command.
Logs: UT_logs.txt