Commit Graph

42 Commits

Author SHA1 Message Date
Lawrence Lee
669687385b [device]: Add SAI checksum verify to TD3 config (#8857)
* [device]: Add SAI checksum verify to TD3 config
* A new config option was added to control the value of IPV4_INCR_CHECKSUM_ORIGINAL_VALUE_VERIFY in the EGR_FLEX_CONFIG control register (this prevents checksums of 0xffff from being propagated to other devices)
2022-07-17 03:11:54 +00:00
bingwang-ms
d9cd1a1355 Add extra lossy PG profile for ports between T1 and T2 (#11157)
Signed-off-by: bingwang <wang.bing@microsoft.com>

Why I did it
This PR brings two changes

Add lossy PG profile for PG2 and PG6 on T1 for ports between T1 and T2.
After PR Update qos config to clear queues for bounced back traffic #10176 , the DSCP_TO_TC_MAP and TC_TO_PG_MAP is updated when remapping is enable

DSCP_TO_TC_MAP
Before	After	Why do this change
"2" : "1"	"2" : "2"	Only change for leaf router to map DSCP 2 to TC 2 as TC 2 will be used for lossless TC
"6" : "1"	"6" : "6"	Only change for leaf router to map DSCP 6 to TC 6 as TC 6 will be used for lossless TC

TC_TO_PRIORITY_GROUP_MAP
Before	After	Why do this change
"2" : "0"	"2" : "2"	Only change for leaf router to map TC 2 to PG 2 as PG 2 will be used for lossless PG
"6" : "0"	"6" : "6"	Only change for leaf router to map TC 6 to PG 6 as PG 6 will be used for lossless PG

So, we have two new lossy PGs (2 and 6) for the T2 facing ports on T1, and two new lossless PGs (2 and 6) for the T0 facing port on T1.
However, there is no lossy PG profile for the T2 facing ports on T1. The lossless PGs for ports between T1 and T0 have been handled by buffermgrd .Therefore, We need to add lossy PG profiles for T2 facing ports on T1.

We don't have this issue on T0 because PG 2 and PG 6 are lossless PGs, and there is no lossy traffic mapped to PG 2 and PG 6

Map port level TC7 to PG0
Before the PCBB change, DSCP48 -> TC 6 -> PG 0.
After the PCBB change, DSCP48 -> TC 7 -> PG 7
Actually, we can map TC7 to PG0 to save a lossy PG.

How I did it
Update the qos and buffer template.

How to verify it
Verified by UT.
2022-06-30 05:15:41 +00:00
vmittal-msft
7c5567553f Updated buffer profile settings for TD3 based HWSKUs (Arista-7050CX3-32S-C32, Arista-7050CX3-32S-D48C8) (#11202)
* Updated buffer profile settings for TD3 based HWSKUs (Arista-7050CX3-32S-C32, Arista-7050CX3-32S-D48C8)
2022-06-24 05:15:14 +00:00
bingwang-ms
6f713419ba Add two extra lossless queues for bounced back traffic (#10496)
Signed-off-by: bingwang <bingwang@microsoft.com>

Why I did it
This PR is to add two extra lossless queues for bounced back traffic.
HLD sonic-net/SONiC#950

SKUs include
Arista-7050CX3-32S-C32
Arista-7050CX3-32S-D48C8
Arista-7260CX3-D108C8
Arista-7260CX3-C64
Arista-7260CX3-Q64

How I did it
Update the buffers.json.j2 template and buffers_config.j2 template to generate new BUFFER_QUEUE table.

For T1 devices, queue 2 and queue 6 are set as lossless queues on T0 facing ports.
For T0 devices, queue 2 and queue 6 are set as lossless queues on T1 facing ports.
Queue 7 is added as a new lossy queue as DSCP 48 is mapped to TC 7, and then mapped into Queue 7

How to verify it
Verified by UT
Verified by coping the new template and generate buffer config with sonic-cfggen
2022-06-22 23:05:14 +00:00
zitingguo-ms
ae90bfae4b [AN/LT][Fix bug]:enable phy_an_lt_msft attribute on some platforms (#11147) 2022-06-16 02:13:22 +00:00
Richard.Yu
af855033ec [Tunnel PFC] Add property for tunnel PFC (#10962)
* [Tunnel PFC] Add property for tunnel PFC

Replace the config.bcm file with j2 template file
- Add 'sai_remap_prio_on_tnl_egress=1' property when device metadata local
- Host subtype is 'dualtor'
- Change sai.profile foe the new config.bcm.j2
2022-06-05 15:21:24 +00:00
bingwang-ms
76502c821e Update qos template to support SYSTEM_DEFAULT table (#10936)
* Update qos template to support SYSTEM_DEFAULT table

Signed-off-by: bingwang <wang.bing@microsoft.com>
2022-06-05 15:21:10 +00:00
vmittal-msft
ede1e0e889
Adjustment to ingress pool size to accomodate brcm sai (#10694) 2022-04-28 20:39:56 -07:00
bingwang-ms
3fc3259a35
Define qos map AZURE_TUNNEL for QoS remapping of tunnel traffic (#10565)
* Add AZURE_TUNNEL map

Signed-off-by: bingwang <wang.bing@microsoft.com>
2022-04-25 15:06:10 +08:00
vmittal-msft
dd243c1024
Changes to support topology and port speed agnostic switch init for TD3 based platforms (#10587) 2022-04-18 15:19:22 -07:00
Nikola Dancejic
f2acf952fb
[device config] Adding configuration for default route fallback (#10465)
* [device config] Adding configuration for default route fallback
* Set sai_tunnel_underlay_route_mode attribute to fallback to default route if more specific route is unavailable.
2022-04-12 14:43:03 -07:00
bingwang-ms
b9dd1df372
Update qos config to clear queues for bounced back traffic (#10176)
* Update qos config to clear queues for bounced back traffic

Signed-off-by: bingwang <bingwang@microsoft.com>
2022-04-05 22:32:25 +08:00
gechiang
ddfe87a71a
[BRCMSAI 6.0.0.13-1] Fix Cancun file directory at new location causing TD3 platform boot issue (#9922) 2022-02-07 08:56:06 -08:00
Prince Sunny
d6c3a9308c
[broadcom]: td2/td3 change cpu cos num to 10 (#9301)
bcm_num_cos=10 forces SDK default to map internal priority 0-7 to COS 0. It is now consistent with other SKUs.
2021-11-17 20:56:46 -08:00
gechiang
ef457ab13f
Disable ALPM distributed hitbit thread that is used for debug purpose only but interfered with Other functional operations (#9199) 2021-11-09 07:21:57 -08:00
Qi Luo
add9b651b6
Add platform_asic file to each platform folder in sonic-device-data based package (#8542)
#### Why I did it
Add platform_asic file to each platform folder in sonic-device-data package. The file content will be used as the ground truth of mapping from PLATFORM_STRING to switch ASIC family.

One use case of the mapping is to prevent installing a wrong image, which targets for other ASIC platforms. For example, currently we have several ONIE images naming as sonic-*.bin, it's easy to mistakenly install the wrong image. With this mapping built into image, we could fetch the ONIE platform string, and figure out which ASIC it is using, and check we are installing the correct image.

After this PR merged, each platform vendor has to add one mandatory text file  `device/PLATFORM_VENDOR/PLATFORM_STRING/platform_asic`, with the content of the platform's switch ASIC family.

I will update https://github.com/Azure/SONiC/wiki/Porting-Guide after this PR is merged.

You can get a list of the ASIC platforms by `ls -b platform | cat`. Currently the options are
```
barefoot
broadcom
cavium
centec
centec-arm64
generic
innovium
marvell
marvell-arm64
marvell-armhf
mellanox
nephos
p4
vs
```

Also support
```
broadcom-dnx
```

#### How I did it

#### How to verify it
Test one image on DUT. And check the folders under `/usr/share/sonic/device`
2021-10-08 19:27:48 -07:00
Ashok Daparthi-Dell
6cbdf11e53
SONIC QOS YANG - Remove qos tables field value refernce format (#7752)
Depends on Azure/sonic-utilities#1626
Depends on Azure/sonic-swss#1754

QOS tables in config db used ABNF format i.e "[TABLE_NAME|name] to refer fieldvalue to other qos tables.

Example:
Config DB:
"Ethernet92|3": {
"scheduler": "[SCHEDULER|scheduler.1]",
"wred_profile": "[WRED_PROFILE|AZURE_LOSSLESS]"
},
"Ethernet0|0": {
"profile": "[BUFFER_PROFILE|ingress_lossy_profile]"
},
"Ethernet0": {
"dscp_to_tc_map": "[DSCP_TO_TC_MAP|AZURE]",
"pfc_enable": "3,4",
"pfc_to_queue_map": "[MAP_PFC_PRIORITY_TO_QUEUE|AZURE]",
"tc_to_pg_map": "[TC_TO_PRIORITY_GROUP_MAP|AZURE]",
"tc_to_queue_map": "[TC_TO_QUEUE_MAP|AZURE]"
},

This format is not consistent with other DB schema followed in sonic.
And also this reference in DB is not required, This is taken care by YANG "leafref".

Removed this format from all platform files to consistent with other sonic db schema.
Example:
"Ethernet92|3": {
"scheduler": "scheduler.1",
"wred_profile": "AZURE_LOSSLESS"
},

Dependent pull requests:
#7752 - To modify platfrom files
#7281 - Yang model
Azure/sonic-utilities#1626 - DB migration
Azure/sonic-swss#1754 - swss change to remove ABNF format
2021-09-28 09:21:24 -07:00
zzhiyuan
144851fea8
[Arista] Add dynamic port breakout hwsku to platforms (#7975)
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
Why I did it
To support dynamic port breakout Broadcom configurations on Arista platforms.

How I did it
Updated platform.json for platforms and added new hwsku, Broadcom config, and hwsku.json for dynamic port breakout usage.

The name of the new hwsku name used is very similar to the platform name (platform x86_64-arista_7050_qx32s hwsku Arista-7050QX-32S) as the flex hwsku is meant to be the default in the future.

How to verify it
Boot up device with the new hwsku, interfaces are up.
Change hwsku.json with new default breakout mode and reload device, breakout will have successfully been applied.
2021-08-16 07:03:50 -07:00
vmittal-msft
e7cec0928b
Updated SONIC buffer pool settings to accomodate SAI adjustment for Arista-7050CX3-32S-C32 (#8159) 2021-07-16 12:32:16 -07:00
gechiang
6fc279b7c1
Add BRCM SOC Property to not count ACL drops towards interface RX_DRP… (#7945)
* Add BRCM SOC Property to not count ACL drops towards interface RX_DRP counter for 7050CX3 and 7260CX3 DualToR platforms
2021-06-23 18:09:47 -07:00
vmittal-msft
aae315faaf
Updated MMU settings for Arista-7050CX3-32S-C32 T1 topology (#7597) 2021-05-12 21:28:19 -07:00
vmittal-msft
68dfa704b3
Updated Qos/MMU settings for Arista-7050CX3-32S-C32 & Arista-7050CX3-32S-D48C8 (#7068)
* TD3 Qos/MMU settings for Arista-7050CX3-32S-C32 & Arista-7050CX3-32S-D48C8
2021-04-30 10:02:08 -07:00
Prince Sunny
dd4d2a75f0
[Broadcom] Set hierarchical ecmp levels to 2 (#7370)
Set hierarchical ecmp level to 2 instead of 3. Based on CS00011833367, ecmp level must be set to 2.
This is already handled for TH2 platforms. Change is required only for TD3

Co-authored-by: Ubuntu <prsunny@prince-vm.vzw1i4tqyeburcdz5lrgulxi2c.yx.internal.cloudapp.net>
2021-04-21 13:22:52 -07:00
Sujin Kang
d5238ae8dd
[pcie.yaml] Move pcie configuration file path to platform directory (#6475)
- Why I did it
The pcie configuration file location is under plugin directory not under platform directory.
#6437

- How I did it

Move all pcie.yaml configuration file from plugin to platform directory.
Remove unnecessary timer to start pcie-check.service
Move pcie-check.service to sonic-host-services
- How to verify it
Verify on the device
2021-02-21 08:27:37 -08:00
vmittal-msft
02cc486511
Remove dummy MMU profiles for Arista-7050CX3-32S-C32 and Arista-7050CX3-32S-D48C8 (#6785) 2021-02-17 11:45:00 -08:00
Vaibhav Hemant Dixit
a7ba1b8b43
Add the 10G ports with updated speed (#6699)
Port_config update for hwsku 7050CX3-32S-C3 - add two 10G ports.
This change is added to fix issue of "PortsOrch initialization failure" seen by previous removal of these 10G ports.
Tested on the device with new minigraph, and the PortsOrch initialization failure is not seen.
2021-02-05 19:34:17 -08:00
gechiang
c98e8d6690
[BCM Config] Update TD3 bcm.config files to use ISSU capable premium CANCUN 6.4.1 (#6651) 2021-02-02 21:48:26 -08:00
Vaibhav Hemant Dixit
580666a406
[arista]: 7050CX3-32S-C32: Remove unused 10G ports and update speed (#6638)
port_config.ini for HWSKU Arista-7050CX3-32S-C32 has missing speed column and duplicated lanes.
The incorrect speed causes issues in Orchagent RESTARTCHECK as the below task remains as the remaining item during swss shutdown.
2021-02-02 11:26:36 -08:00
Tamer Ahmed
284c2738e8
[sonic-device-data]: Update BRCM Tunnel/ECMP Parameter For 7050cx3 SKUs (#6415)
Update Tunnel and ECMP parameters for brcm 7050cx3 48x50G+8x100G and 32x100G SKUs.

signed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
2021-01-29 14:15:48 -08:00
Samuel Angebault
4e0a869b44
[arista]: Add placeholder healthd configuration for all platforms (#6233)
Prevent system-healthd from service from failing at boot time due to missing configuration.
Also adds basic support for healthd.
The following caveat exists with this placeholder configuration:
 - No PSU monitoring (sensors/fans)
 - No ASIC temperature monitoring
2020-12-17 05:18:38 -08:00
zzhiyuan
4d4b489a5f
Add platform.json to Arista platforms (#6150)
platform.json is needed for sonic-mgmt testing. Also in the future it will be used as part of dynamic port breakout.

Also removed the folder symlink for BlackhawkDD because it has a different platform.json than BlackhawkO.

Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
2020-12-08 10:20:13 -08:00
Ying Xie
1ba583cb46
[TD3] add dummy MMU configuration for Arista-7050CX3-32S-D48C8 (#5950)
Need A mmu configuration to get the device going without generating lots of warnings.

Similar to dummy MMU configuration for Arista-7050CX3-32S-C32, this configuration will need to be updated with correct numbers. This MMU configuration is copied from 7060 comparable hwsku.

Signed-off-by: Ying Xie <ying.xie@microsoft.com>
2020-11-17 19:01:39 -08:00
Ying Xie
6a8ebef449
[Arista 7050cx3] add dummy MMU configurations for Arista-7050CX3-32S-C32 (#5798)
- Why I did it
On Arista-7050CX3-32S-C32, there are constant stream of errors like following.

Nov 3 21:56:24.415190 str2-7050cx3-acs-06 NOTICE swss#orchagent: :- registerInWdDb: No lossless TC found on port Ethernet68

Which causes:

loganalyzer to claim test failed.
leaving the system without MMU configuration. Which couldn't be good for any IO test.
- How I did it
Added these MMU configuraions are copied from another platform and guaranteed to be incorrect for hwsku Arista-7050CX3-32S-C32.

Adding them so that we have A MMU configuration and the system won't throw a whole bunch of errors and leave MMU unconfigured. The correct MMU configuration will come later.

This configuration is definitely not suitable for testing system performance or QoS behavior.

Signed-off-by: Ying Xie ying.xie@microsoft.com

- How to verify it
Test will have chance to pass. Ran a few test that would fail otherwise.
2020-11-09 13:27:36 -08:00
Samuel Angebault
5bfe37ca42
[Arista] Update driver submodules (#5686)
- Enable thermalctld support for our platforms
 - Fix Chassis.get_num_sfp which had an off by one
 - Implement read_eeprom and write_eeprom in SfpBase
 - Refactor of Psus and PsuSlots. Psus they are now detected and metadata reported
 - Improvements to modular support

Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
2020-10-23 12:28:36 -07:00
Samuel Angebault
a24b581d80
[Arista] Add pcie.yaml configuration file for a few platforms (#5527)
* Add pcie.yaml configuration for Gardena
* Add pcie.yaml configuration for Upperlake
* Add pcie.yaml configuration for Clearlake
* Add pcie.yaml configuration for Lodoga
2020-10-02 09:05:43 -07:00
Samuel Angebault
4ec83b25bc
[arista]: Add new 48x50G + 8x100G hwsku for Lodoga (#5452) 2020-09-23 22:41:07 -07:00
abdosi
a6a10f05b7
In SAI 3.5 by default we are supporting 256 Group with 64 Memeber each. (#5400)
However in SAI 3.7 default behaviout got changes to 128 Group and 128
    Memeber each.

    This change is to make sure we are using same ECMP Group/Memeber Per
    Group for 3.7 also so that behaviour is consistent.

Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
2020-09-22 11:21:12 -07:00
abdosi
b6efb49817
Update bcm soc property bcm_num_cos from 8 to 10 (#5314)
as needed by SAI 3.7 and above. Without this change
Warmboot fails from 3.5 to 3.7 as Braodcoam Datastructure
gets corrupted after warm-boot.

Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
2020-09-04 07:40:17 -07:00
zzhiyuan
2c426a8290 Skip thermalctld for arista platforms (#4893)
thermalctld throwing error messages because it is not yet fully configured, disabling it for now on arista platforms.

Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
2020-07-12 18:08:51 +00:00
Samuel Angebault
de4fa1874a
[arista]: remove the soc property disabling sram scan (#4623) 2020-05-20 12:44:48 -07:00
byu343
ae52223892
[arista]: Add fancontrol for arista 7050cx3 (#4121) 2020-02-11 13:19:07 -08:00
Samuel Angebault
64500e143b [Arista] Update drivers and boot script (#3959)
* Update arista driver submodule

* Add support for 7260CX3-64E in boot0

* Refactor boot0 platform specific definition

Make it easier to manage new sku

* Add support for 7050CX3-32S in boot0

Just contains the required boot0 information

* Add basic plugin support for DCS-7050CX3-32S

* Add port config for Arista-7050CX3-32S-C32

Co-authored-by: yurypm <yurypm@arista.com>
Co-authored-by: byu343 <byu@arista.com>
2020-01-17 10:44:49 -08:00