Commit Graph

162 Commits

Author SHA1 Message Date
Junchao-Mellanox
f73d322081
Fix issue: watchdogutil command does not work (#16242)
Conflicts:
	platform/mellanox/mlnx-platform-api/sonic_platform/watchdog.py
	platform/mellanox/mlnx-platform-api/tests/test_watchdog.py
2023-08-28 23:58:15 +08:00
mssonicbld
946d276f96
[Mellanox] Remove reset_from_comex from reboot cause mapping (#15793) (#16039) 2023-08-06 14:03:59 +08:00
mssonicbld
b04c39f656
[Mellanox] Add support for BIOS update on Spectrum-4 (#15795) (#15941) 2023-07-23 22:42:39 +08:00
mssonicbld
923da6fc84
[Mellanox] get LED capability from capability file (#14584) (#15664) 2023-06-30 00:26:23 +08:00
mssonicbld
f407a10c27
[Mellanox] Adjust warning threshold implementation according to the latest algorithm update (#15092) (#15665) 2023-06-30 00:25:50 +08:00
Junchao-Mellanox
af7412d3a1 [Mellanox] add PSU fan direction support (#14508)
- Why I did it
Add PSU fan direction support

- How I did it
Implement fan.get_direction for PSU fan

- How to verify it
Manual test
Unit test
2023-06-10 12:32:26 +08:00
mssonicbld
d8f2f7c034
[Mellanox] Use sysfs for sfp reset/LPM/presence (#14130) (#15215) 2023-05-26 02:25:21 +08:00
Sudharsan Dhamal Gopalarathnam
156189dbad [Mellanox]Fix lpmode set when logical port is larger than 64 (#14138)
- Why I did it
In sfplpm API, the number of logical ports is hardcoded as 64. When a system contains more port than this, the SDK APIs would fail with a syslog as below

Mar 7 03:53:58.105980 r-leopard-58 ERR syncd#SDK: [MGMT_LIB.ERR] Slot [0] Module [0] has logport [0x00010069] in enabled state
Mar 7 03:53:58.105980 r-leopard-58 ERR syncd#SDK: [SDK_MGMT_LIB.ERR] Failed in __sdk_mgmt_phy_module_pwr_attr_set, error: Internal Error
Mar 7 03:53:58.106118 r-leopard-58 ERR pmon#-c: Error occurred when setting power mode for SFP module 0, slot 0, error code 1

- How I did it
Remove the hardcoded value of 64. Obtained the number of logical ports from SDK

- How to verify it
Manual testing
2023-03-19 20:50:58 +08:00
mssonicbld
aea96da04d
[Mellanox] Fix issue: cannot find label port for logical port when logical port number is larger than 64 (#13710) (#13962) 2023-03-06 16:47:31 +08:00
Junchao-Mellanox
e8789a2e11 [Mellanox] Check system eeprom existence in a retry manner (#13884)
- Why I did it
On Mellanox platform, system EEPROM is a soft link provided by hw-management. There is chance that config-setup service accessing the EEPROM before hw-management creating it. It causes errors. The PR is aim to fix it.

- How I did it
Waiting EEPROM creation in platform API up to 10 seconds.

- How to verify it
Manual test
2023-02-23 20:31:29 +08:00
Stephen Sun
4f3b649f8e [Mellanox] Support per PSU slope value for PSU power threshold (#13757)
- Why I did it
Support per PSU slope value for PSU power threshold according to hardware team requirement

- How I did it
Pass the PSU number as a parameter when fetching the slope value of PSU.

- How to verify it
Running regression and manual test

Signed-off-by: Stephen Sun <stephens@nvidia.com>
2023-02-20 12:38:20 +08:00
Vadym Hlushko
3530fdbea1 [SFP] Change logging severity when failed to read EEPROM (#13011)
- Why I did it
In order to prevent the sonic-mgmt/tests/platform_tests/sfp/test_sfputil.py test failing on the log analyzer step.

The mentioned test is performing the sfputil reset EthernetX for every interface on the SONiC switch, this action will flap the SFP device status (INSTERTED -> REMOVED -> INSTERTED).

The SONiC XCVRD daemon will catch this SFP device status change (because it is monitoring the presence status of the cable).
To judge the cable presence status, currently, we are still leveraging to read the first bytes of the EEPROM, and the EEPROM could be not ready at some moment and the SONiC XCVRD daemon will print the error log to Syslog:

ERR pmon#xcvrd: Error! Unable to read data for 'xx' port, page 'xx' offset 128, rc = 1, err msg: Sending access register

- How I did it
Change logging severity from ERR to WARNING

- How to verify it
Run the sonic-mgmt/tests/platform_tests/sfp/test_sfputil.py

OR much faster way to run the next script on the switch:

#!/bin/bash

START=0
END=248

for (( intf=$START; intf<=$END; intf+=8))
do
    sfputil reset Ethernet"${intf}"
done

sfputil show presence
2023-02-04 02:36:51 +08:00
Junchao-Mellanox
cf6f31b215 [Mellanox] Remove TODO comments which are no longer needed (#13023)
- Why I did it
Remove TODO comments which are no longer needed

- How I did it
Remove TODO comments which are no longer needed

- How to verify it
Only comment change
2023-02-04 02:36:47 +08:00
Kebo Liu
9680479661 [Mellanox] change the implementation of is_host() to fix a stuck issue on simx platform (#13100)
- Why I did it
Following code to judge whether a process is running inside a docker could get stuck on the simx platform

subprocess.Popen(["docker", "--version"],
                                stdout=subprocess.PIPE,
                                stderr=subprocess.STDOUT,
                                universal_newlines=True)
When it gets stuck, the config-chassisdb service can not be successfully started, thus the system can not be booted up.

root@sonic:/# service config-chassisdb status
     config-chassisdb.service - Config chassis_db
     Loaded: loaded (/lib/systemd/system/config-chassisdb.service; enabled; vendor preset: enabled)
     Active: activating (start) since Thu 2022-12-15 09:23:02 UTC; 29min ago
   Main PID: 571 (config-chassisd)
      Tasks: 14 (limit: 9501)
     Memory: 132.4M
     CGroup: /system.slice/config-chassisdb.service
                        ├─571 /bin/bash /usr/bin/config-chassisdb
			├─575 /usr/bin/python3 /usr/local/bin/sonic-cfggen -H -v DEVICE_METADATA.localhost.platform
			├─602 /bin/sh -c sudo decode-syseeprom -m
			├─603 sudo decode-syseeprom -m
			├─607 /usr/bin/python3 /usr/local/bin/decode-syseeprom -m
			├─616 /bin/sh -c docker --version 2>/dev/null
			└─617 docker --version

- How I did it
Use an alternative way to implement this function and issue can be avoided:

docker_env_file = '/.dockerenv'
return os.path.exists(docker_env_file) is False

- How to verify it
run regression on real hardware and simx platform.
2023-02-04 02:36:43 +08:00
Kebo Liu
ab54549d53 [Mellanox] Skip the leftover hardware reboot cause in case of last boot is warm/fast reboot (#13246)
- Why I did it
In case of warm/fast reboot, the hardware reboot cause will NOT be cleared because CPLD will not be touched in this flow. To not confuse the reboot cause determine logic, the leftover hardware reboot cause shall be skipped by the platform API, platform API will return the 'REBOOT_CAUSE_NON_HARDWARE' instead of the "hardware" reboot cause.

- How I did it
Check the proc cmdline to see whether the last reboot is a warm or fast reboot, if yes skip checking the leftover hardware reboot cause.

- How to verify it
a. Manual test:
    - Perform a power loss
    - Perform a warm/fast reboot
    - Check the reboot cause should be "warm-reboot" or "fast-reboot" instead of "power loss"
b. Run reboot cause related regression test.

Signed-off-by: Kebo Liu <kebol@nvidia.com>
2023-01-31 18:34:36 +08:00
Stephen Sun
91e12d7b49 [Mellanox] Support PSU power threshold checking (#11863)
* Support power threshold

Signed-off-by: Stephen Sun <stephens@nvidia.com>

* get_psu_power_warning_threshold => get_psu_power_warning_suppress_threshold

Signed-off-by: Stephen Sun <stephens@nvidia.com>

* Fix comments

Signed-off-by: Stephen Sun <stephens@nvidia.com>

Signed-off-by: Stephen Sun <stephens@nvidia.com>
2022-12-10 10:33:21 +08:00
Junchao-Mellanox
20d885dbc2
[Mellanox] Add new thermal sensors for SN5600 (#12671)
- Why I did it
Add new thermal sensors for SN5600

- How I did it
Add new thermal sensors for SN5600: PCH and SODIMM

- How to verify it
Manual test
2022-11-14 11:10:33 -08:00
Kebo Liu
c8c2b7fc45
[Mellanox] [Platform API] Update SN2201 dynamic minimum fan speed table (#12602)
- Why I did it
Update SN2201 dynamic minimum fan speed table according to data provided by the thermal team.

- How I did it
Update the thermal table in device_data.py

- How to verify it
Run platform related regression

Signed-off-by: Kebo Liu <kebol@nvidia.com>
2022-11-08 13:37:10 +02:00
Junchao-Mellanox
830b7d8cb4
[Mellanox] Use sdk sysfs instead of ethtool (#12480) 2022-11-03 11:17:44 -07:00
Stephen Sun
8c73e68468
Remove \n from the end of fs_path in ONIEUpdater (#12465)
This fixes the following error

```
admin@sonic:~$ sudo fwutil show status
mount: /mnt/onie-fs: special device /dev/sda2
 does not exist.
Error: Command '['mount', '-n', '-r', '-t', 'ext4', '/dev/sda2\n', '/mnt/onie-fs']' returned non-zero exit status 32.. Aborting...
Aborted!
admin@sonic:~$ sudo vi /usr/local/lib/python3.9/dist-packages/sonic_platform/

```
Seems like #11877 the rstrip('\n') was removed. Probably by mistake.

Signed-off-by: Stephen Sun <stephens@nvidia.com>
2022-10-23 09:59:20 +03:00
Mai Bui
648ca075c7
[device/mellanox] Mitigation for security vulnerability (#11877)
Signed-off-by: maipbui <maibui@microsoft.com>
Dependency: [PR (#12065)](https://github.com/sonic-net/sonic-buildimage/pull/12065) needs to merge first.
#### Why I did it
`subprocess.Popen()` and `subprocess.check_output()` is used with `shell=True`, which is very dangerous for shell injection.
#### How I did it
Disable `shell=True`, enable `shell=False`
#### How to verify it
Tested on DUT, compare and verify the output between the original behavior and the new changes' behavior.
[testresults.zip](https://github.com/sonic-net/sonic-buildimage/files/9550867/testresults.zip)
2022-10-06 17:51:31 -04:00
Junchao-Mellanox
1d69f0916e
[Mellanox] Provide dummy implementation for get_rx_los and get_tx_fault (#12231)
- Why I did it
get_rx_los and get_tx_fault is not supported via the exisitng interface used, need provide dummy implementation for them.
NOTE: in later releases we will get them back via different interface.

- How I did it
Return False * lane_num for get_rx_los and get_tx_fault

- How to verify it
Added unit test
2022-09-30 09:38:05 +03:00
Stephen Sun
4d317aff94
[Mellanox] Fix typo in platform API (#12136)
- Why I did it
Fix a typo in chassis platform API which causes the following error

>>> import sonic_platform as P
>>> c = P.platform.Platform().get_chassis()
>>> sl = c.get_all_sfps()
>>> sl[0].get_lpmode()
Sep 28 07:48:33 INFO    LOG: Initializing SX log with STDOUT as output file.
False
>>> del c
Exception ignored in: <function Chassis.__del__ at 0x7f1d166ef8b0>
Traceback (most recent call last):
  File "/usr/local/lib/python3.9/dist-packages/sonic_platform/chassis.py", line 126, in __del__
    self.sfp_module.deinitialize_sdk_handle(sfp_module.SFP.shared_sdk_handle)
NameError: name 'sfp_module' is not defined

- How I did it
Use self while using the SDK handle

- How to verify it
Manual test

Signed-off-by: Stephen Sun <stephens@nvidia.com>
2022-09-28 11:09:18 +03:00
Junchao-Mellanox
f890606d82
Revert "[Mellanox] Redirect ethtool stderr to subprocess for better error log (#12038)" (#12183)
This reverts commit 9750cb4.

There is a PR to handle 202205 branch revert: #12184

- Why I did it
The PR to be reverted introduced many notice logs every 1 minute if SFP is not plugged:

Cannot get module EEPROM information: Input/output error
Before the "bad" PR, the message format is like this:

INFO pmon#supervisord: xcvrd Cannot get module EEPROM information: Input/output error
It was truncated by rsyslog because every message is the same. However, the "bad" PR introduces SFP index to the message:

NOTICE pmon#xcvrd: Failed to get EEPROM data for sfp 39: Cannot get module EEPROM information: Input/output error
Rsyslog no longer truncate such log and many such messages are flooded to syslog.

- How I did it
Revert the PR

- How to verify it
Manual test
2022-09-28 10:15:26 +03:00
Junchao-Mellanox
9750cb48c6
[Mellanox] Redirect ethtool stderr to subprocess for better error log (#12038)
- Why I did it
ethtool print error logs when EEPROM of a SFP is not available. It prints error like this:

INFO pmon#/supervisord: xcvrd Cannot get module EEPROM information: Input/output error
INFO pmon#/supervisord: xcvrd Cannot get Module EEPROM data: Invalid argument
However, this log does not contain the relevant SFP index which is hard for developer/qa to find the exactly SFP.

- How I did it
Redirect ethtool stderr to subprocess and log it better

- How to verify it
Manual test
2022-09-14 20:41:43 +03:00
Junchao-Mellanox
46ebd06403
[Mellanox] Fix issue: set lpmode by platform API does not work (#11732)
- Why I did it
Fix issue: set lpmode by platform API does not work

- How I did it
Fix miss return value in code

- How to verify it
Manual test
2022-08-18 13:07:38 +03:00
orfarfara
aec1248258
[Mellanox] add PSU input voltage and current (#11510)
- Why I did it
Add PSU input voltage and input current to mlnx platform api.

- How I did it
Implement 2 function of getting the psu voltage and psu current input:
Get the values from "power/psu{}_curr_in" , "power/psu{}_volt_in"

- How to verify it
Manual test.
Run sonic-mgmt regression

Signed-off-by: orfar1994 <orfar1994@gmail.com>
2022-08-10 18:10:55 +03:00
Junchao-Mellanox
4c1c0c1852
[Mellanox] add more log while doing sysfs reading (#11556)
- Why I did it
Add more log while doing sysfs reading to increase the debug capability

- How I did it
Log the relevant file path and error number while sysfs reading return None

- How to verify it
Manual test
2022-08-08 15:06:52 +03:00
Stephen Sun
81600fafe9
[Mellanox] Support new platform API get_port_or_cage_type for RJ45 ports (#11336)
- Why I did it
Support get_port_or_cage_type for RJ45 ports

- How I did it
Implement the new platform API get_port_or_cage_type
Fix the issue: unable to import SFP when chassis object is destructed

- How to verify it
Manually test and regression test

Signed-off-by: Stephen Sun <stephens@nvidia.com>
2022-07-14 12:20:16 +03:00
Junchao-Mellanox
2863945f7c
[Mellanox] Fix issue: failed to decode Json while there is no hwsku.json (#11436)
- Why I did it
Fix bug: pmon report error on start up because some SKUs do not have hwsku.json

- How I did it
If hwsku.json, do not extract RJ45 port information

- How to verify it
Manual test.
Unit test.
2022-07-14 09:24:39 +03:00
Sudharsan Dhamal Gopalarathnam
23d68883f5
[Mellanox]Check dmi file permission before access (#11309)
Signed-off-by: Sudharsan Dhamal Gopalarathnam sudharsand@nvidia.com

Why I did it
During the system boot up when 'show platform status' or 'show version' command is executed before STATE_DB CHASSIS_INFO table is populated, the show will try to fallback to use the platform API. The DMI file in mellanox platforms require root permission for access. So if the show commands are executed as admin or any other user, the following error log will appear in the syslog

Jun 28 17:21:25.612123 sonic ERR show: Fail to decode DMI /sys/firmware/dmi/entries/2-0/raw due to PermissionError(13, 'Permission denied')

How I did it
Check the file permission before accessing it.

How to verify it
Added UT to verify. Manually verified if the error log is not thrown.
2022-07-01 17:29:07 -07:00
Kebo Liu
7ac590b5c5
[Mellanox] Enhance Platform API to support SN2201 - RJ45 ports and new components mgmt. (#10377)
* Support new platform SN2201 and RJ45 port

Signed-off-by: Kebo Liu <kebol@nvidia.com>

* remove unused import and redundant function

Signed-off-by: Kebo Liu <kebol@nvidia.com>

* fix error introduced by rebase

Signed-off-by: Kebo Liu <kebol@nvidia.com>

* Revert the special handling of RJ45 ports (#56)

* Revert the special handling of RJ45 ports

sfp.py
sfp_event.py
chassis.py

Signed-off-by: Stephen Sun <stephens@nvidia.com>

* Remove deadcode

Signed-off-by: Stephen Sun <stephens@nvidia.com>

* Support CPLD update for SN2201

A new class is introduced, deriving from ComponentCPLD and overloading _install_firmware
Change _install_firmware from private (starting with __) to protected, making it overloadable

Signed-off-by: Stephen Sun <stephens@nvidia.com>

* Initialize component BIOS/CPLD

Signed-off-by: Stephen Sun <stephens@nvidia.com>

* Remove swb_amb which doesn't on DVT board any more

Signed-off-by: Stephen Sun <stephens@nvidia.com>

* Remove the unexisted sensor - switch board ambient - from platform.json

Signed-off-by: Stephen Sun <stephens@nvidia.com>

* Do not report error on receiving unknown status on RJ45 ports

Translate it to disconnect for RJ45 ports
Report error for xSFP ports

Signed-off-by: Stephen Sun <stephens@nvidia.com>

* Add reinit for RJ45 to avoid exception

Signed-off-by: Stephen Sun <stephens@nvidia.com>

Co-authored-by: Stephen Sun <5379172+stephenxs@users.noreply.github.com>
Co-authored-by: Stephen Sun <stephens@nvidia.com>
2022-06-20 19:12:20 -07:00
Junchao-Mellanox
f135f37a50
[Mellanox] optimize platform API import time (#10815)
- Why I did it
"import sonic_platform" takes about 600ms ~ 1000ms, it is kind of slow. After this optimization, the time is about 100ms. The benefit is that those CLIs which does not need the slow import sentence would be faster than before.

- How I did it
Find slow import and call them when need.

- How to verify it
Measure the import time.
2022-06-07 15:13:16 +03:00
Andriy Yurkiv
70d71f99f5
[Mellanox] Credo Y-cable | add more log info, checks, fix exception message (#10779)
- Why I did it
Script fails when there is an exception while reading

- How I did it
Add more logs and checks. Fix wrong variable naming and messages.

- How to verify it
Provoke exception while read_eeprom() and check that it is handled properly
2022-05-19 17:36:02 +03:00
Junchao-Mellanox
af5e5c4c94
[Mellanox] Adjust PSU voltage WA (#10619)
- Why I did it
InvalidPsuVolWA.run might raise exception if user power off PSU when it is running. This exception is not caught and will be raised to psud which causes psud failed to update PSU data to DB.

- How I did it
1. Change the log level when WA does not work. This could happen when user power off PSU, hence changing the log level from error to warning is better
2. Change the wait time from 5 to 1 to avoid introduce too much delay in psud. 1 second is usually enough per my test
3. Give a default return value for function get_voltage_low_threshold and get_voltage_high_threshold to avoid exception reach to psud

- How to verify it
Manual test.
Run sonic-mgmt regression
2022-04-22 11:02:30 +03:00
Kebo Liu
a0c76b1bc9
[Mellanox] support newly added reboot cause (#10531)
- Why I did it
Implement newly added reboot causes in PR Azure/sonic-platform-common#277

- How I did it
Map the reboot cause sysfs to the newly added reboot causes.

- How to verify it
manual test, check whether the reboot cause is correct after rebooting the switch in various ways.
run the community reboot test to see whether the reboot cause checker is passing.

Signed-off-by: Kebo Liu <kebol@nvidia.com>
2022-04-18 10:55:56 +03:00
Junchao-Mellanox
0191300b96
[Mellanox] Auto correct PSU voltage threshold (WA) (#10394)
- Why I did it
There is a hardware bug that PSU voltage threshold sysfs returns incorrect value. The workaround is to call "sensor -s" to refresh it.

- How I did it
Call "sensor -s" when the threshold value is not incorrect and PSU is "DELTA 1100"

- How to verify it
Unit test and Manual test
2022-04-14 08:14:40 +03:00
Andriy Yurkiv
1e2e493daa
[Mellanox] Credo Y-cable read_eeprom/write_eeprom API implementation (#10320)
- Why I did it
Implement read_eeprom/write_eeprom API for Credo Y-cable for Dual ToR Active-Standby

- How I did it
Use mlxreg utility for API implementation

Signed-off-by: Andriy Yurkiv <ayurkiv@nvidia.com>
2022-03-30 20:41:31 +03:00
Dror Prital
8bc81206c5
[Mellanox] Update NVIDIA License header for files changed since 1.1.2022 (#10289)
- Why I did it
Update NVIDIA Copyright header to "mellanox" files which were changed since 1.1.2022

- How I did it
Update the copyright header

- How to verify it
Sanity tests and PR checkers.
2022-03-23 13:19:25 +02:00
Oleksandr Ivantsiv
9565ef7a9a
[Mellanox] Refactor SFP to use new APIs. (#10317)
- Why I did it
Refactor SFP code to remove code duplication and to be able to use the latest features available in new APIs.

- How I did it
Refactor SFP code to remove code duplication and to be able to use the latest features available in new APIs.

- How to verify it
Run sonic-mgmt/platform_tests/sfp tests
2022-03-23 09:16:03 +02:00
Junchao-Mellanox
f0ddd102d5
[Mellanox] Add CPU thermal control for Nvidia platforms (#10202)
Why I did it
Add CPU thermal control for Nvidia platforms which will be enabled for platforms that have heavy CPU load. Now it is only enabled on 4800, and it will be enabled on future platforms.

How I did it
Check CPU pack temperature and update cooling level accordingly

How to verify it
Manual test
Added sonic-mgmt test case, PR link will update later
2022-03-21 09:54:52 -07:00
Junchao-Mellanox
dc04d64219
[Mellanox] Fix issue: psu might use wrong voltage sysfs which causes invalid voltage value (#10231)
- Why I did it
Fix issue: psu might use wrong voltage sysfs which causes invalid voltage value. The flow is like:

1. User power off a PSU
2. All sysfs files related to this PSU are removed
3. User did a reboot/config reload
4. PSU will use wrong sysfs as voltage node

- How I did it
Always try find an existing sysfs.

- How to verify it
Manual test
2022-03-20 10:34:04 +02:00
Junchao-Mellanox
fe59e0f2c0
[Mellanox] Fix issue: thermal zone threshold value 0 causes fan speed stuck at 100% (#10057)
- Why I did it
In SONiC thermal control algorithm, it compares thermal zone temperature with thermal zone threshold. Previously, a thermal zone with no thermal sensor can still get its threshold. However, a recently driver patch changes this behavior: a thermal zone with no thermal sensor will return 0 for threshold. We need to ignore such thermal zone.

- How I did it
Ignore thermal zones whose temperature is 0.

- How to verify it
Added unit test case and Manual test
2022-02-24 12:05:56 +02:00
Stephen Sun
486e9b0c75
Fix issue: module id got from get_change_event is wrong (#9961)
Signed-off-by: Stephen Sun <stephens@nvidia.com>
2022-02-13 09:20:37 +05:30
Junchao-Mellanox
43e967d6a4
Fix issue: 'sx_port_mapping_t' object has no attribute 'slot_id' (#9835)
- Why I did it
Fix issue: 'sx_port_mapping_t' object has no attribute 'slot_id'. sx_port_mapping_t only has attribute slot.

- How I did it
Change slot_id to slot.

- How to verify it
Manual test
2022-01-27 07:38:32 +02:00
Junchao-Mellanox
8e590da563
[Mellanox] Fix select timeout in sfp event (#9795)
- Why I did it
Python select.select accept a optional timeout value in seconds, however, the value passes to it is a value in millisecond.

- How I did it
Transfer the value to millisecond.

- How to verify it
Manual test
2022-01-27 07:36:56 +02:00
Alexander Allen
8a07af95e5
[Mellanox] Modified Platform API to support all firmware updates in single boot (#9608)
Why I did it
Requirements from Microsoft for fwutil update all state that all firmwares which support this upgrade flow must support upgrade within a single boot cycle. This conflicted with a number of Mellanox upgrade flows which have been revised to safely meet this requirement.

How I did it
Added --no-power-cycle flags to SSD and ONIE firmware scripts
Modified Platform API to call firmware upgrade flows with this new flag during fwutil update all
Added a script to our reboot plugin to handle installing firmwares in the correct order with prior to reboot
How to verify it
Populate platform_components.json with firmware for CPLD / BIOS / ONIE / SSD
Execute fwutil update all fw --boot cold
CPLD will burn / ONIE and BIOS images will stage / SSD will schedule for reboot
Reboot the switch
SSD will install / CPLD will refresh / switch will power cycle into ONIE
ONIE installer will upgrade ONIE and BIOS / switch will reboot back into SONiC
In SONiC run fwutil show status to check that all firmware upgrades were successful
2022-01-24 00:56:38 -08:00
Junchao-Mellanox
4ae504a813
[Mellanox] Optimize thermal control policies (#9452)
- Why I did it
Optimize thermal control policies to simplify the logic and add more protection code in policies to make sure it works even if kernel algorithm does not work.

- How I did it
Reduce unused thermal policies
Add timely ASIC temperature check in thermal policy to make sure ASIC temperature and fan speed is coordinated
Minimum allowed fan speed now is calculated by max of the expected fan speed among all policies
Move some logic from fan.py to thermal.py to make it more readable

- How to verify it
1. Manual test
2. Regression
2022-01-19 11:44:37 +02:00
Junchao-Mellanox
ca36b4a57b
Fix build issue: cannot import name FW_AUTO_ERR_UKNOWN- required module not found (#9764) 2022-01-14 20:12:53 +05:30
Lior Avramov
a9c9f56eeb
[Mellanox] Include CPU board and switch board sensors only on SN2201 system (#9644)
Why I did it
Recently additional sensors that were needed only for specific system added to all systems and caused errors.

How I did it
* Include CPU board and switch board sensors only on SN2201 system
* Fix issue in test_chassis_thermal, now it skips non existing thermals.

How to verify it
Run show platform temperature

Signed-off-by: liora <liora@nvidia.com>
2022-01-05 10:25:47 -08:00