* catch signal SIGINT and SIGTERM to set all fans full-speed before end fan monitor.
Signed-off-by: roy_lee <roy_lee@accton.com>
* Add fan_control monitor for as7816-64x.
Signed-off-by: roy_lee <roy_lee@accton.com>
* Fix typo.
Signed-off-by: roy_lee <roy_lee@accton.com>
* Correct typo and duty setting after verified.
Signed-off-by: roy_lee <roy_lee@accton.com>
* [frr]: change frr as default sonic routing stack
* fix quagga configuration
* [vstest]: fix bgp test for frr
* [vstest]: skip bgp/test_invalid_nexthop.py for frr
Signed-off-by: Guohan Lu <gulv@microsoft.com>
* [service] Restart SwSS Docker container if orchagent exits unexpectedly
* Configure systemd to stop restarting swss if it attempts to restart more than 3 times in 20 minutes
* Move supervisor-proc-exit-listener script
* [docker-dhcp-relay] Enhance wait_for_intf.sh.j2 to utilize STATEDB
* Ensure dependent services stop/start/restart with SwSS
* Change 'StartLimitInterval' to 'StartLimitIntervalSec', as Stretch installs systemd 232 (>= v230)
* Also update journald.conf options
* Remove 'PartOf' option from unit files
* Add '$(SUPERVISOR_PROC_EXIT_LISTENER_SCRIPT)' to new shared docker-orchagent makefile
* Make supervisor-proc-exit-listener script read from 'critical_processes' file inside container
* Update critical_processes file for swss container
Submodule src/sonic-utilities 6ee0aea..b531934:
> [db migrator] Introduce the DB migration infrastructure (#519)
> Skip INTERFACE entries w/o prefix (#477)
> Bring queue storm status to 'pfcwd show stats' (#500)
> Align PSU DB count field with the schema Spec. (#509)
> [scripts] remove duplicate script copying for nbrshow (#517)
> If fast-reboot-dump gives an error, don't continue with fast-reboot (#515)
> load_minigraph: restart hostcfgd (#511)
> [fast/warm reboot] add some sanity check before warm reboot (#510)
> show BPS, PPS, UTIL rates w/o previous clear (#508)
> In sync with our latest change, where we default failthrough to be False. (#507)
> Add warm-boot feature processing for wedge100bf_32x/65x platforms (#485)
> [generate_dump] system dump improvements (#503)
> [neighbor advertiser] convert int to string before concatenating (#505)
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* DellEMC S6000, xcvrd support
* sleep 1 second to avoid busy looping
* removal of dead code
* Correct typo error to 1 second
* Introduced 1 second sleep
* Revamped script with blocking call support
* get_transceiver_change_event api definition update
* adding timeout support for get_transceiver_change_event
Port libteam patch which fixes the race condition we observed during
warm reboot.
Remove early patches: 0006, 0008, 0009.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* Base DHCP relay Docker image on Strech base Docker
* Change URL for isc-dhcp source repository
* Upgrade isc-dhcp source branch to 4.3.5-3.1
* Update patch #0001 to apply to isc-dhcp 4.3.5-3.1
* Update patch #0002 to apply to isc-dhcp 4.3.5-3.1
* Update patch #0003 to apply to isc-dhcp 4.3.5-3.1
* Update patch #0004 to apply to isc-dhcp 4.3.5-3.1
* Remove security patches, as they are now applied as part of 4.3.5-3.1 source
* Reorder patches to apply bug fix first, then features
* Extend makefile to build debug Docker image
* Update commit that series file applies against
SWSS clears DB tables, if teamd is not started after swss, there is a
race condition that swss might clear vital teamd information.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* Add bridge-utils to orchagent image
- Add vxlanmgrd to supervisorctl in docker -orchagent
Signed-off-by: Ze Gan zegan@microsoft.com
* Update submodule pointer for swss to include Vxlanmgrd changes
The base syncd dockers follow a template, which defines the base docker as DOCKER_SYNCD_BASE instead of DOCKER_SYNCD_. Fix the docker-syncd-<mlnx, bfn>.mk to use the new one.
This service (weekly) will let SSD firmware to do the garbage collection
after file-system deleted files. It could avoid slowness or
even READ-ONLY error due to SSD not being able to free the pages
even though the file system thinks there was a lot of space left.
Signed-off-by: Zhenggen Xu <zxu@linkedin.com>
Overall goal: Build debug images for every stretch docker.
An earlier PR (#2789) made the first cut, by transforming broadcom/orchagent to build target/docker-orhagent-dbg.gz.
Changes in this PR:
Made docker-orchagent build to be platform independent.
1.1) Created rules/docker_orchagent.mk
1.2) Removed platform//docker-orchagent-*.mk
1.3) Removed the corresponding entry from platform//rules.mk
Extended the debug docker image build to stretch based syncd dockers.
2.1) For now, only mellanox & barefoot are stretch based.
2.2) All the common variable definitions are put in one place platform/template/docker-syncd-base.mk
2.3) platform/[mellanox, bfn]/docker-syncd-[mlnx, bfn].mk are updated as detailed below.
2.3.1) Set platform code and include template base file
2.3.2) Add the dependencies & debug dependencies and any update over what base template offers.
Extended all stretch based non-platform dockers to build debug dockers too.
3.1) Affected are:
docker-database.mk,
docker-platform-monitor.mk,
docker-router-advertiser.mk,
docker-teamd.mk,
docker-telemetry.mk
Next: Build debug flavor of final images with regular dockers replaced with debug dockers where available.
* Add new device CIG CS6436-56P
* Delete minigraph.xml
It isn't necessary in the current system, just delete it
* Update qos.json.j2
* Update port_config.ini
Add the speed column. The cmd to show interface status as:
root@switch1:~# show interface status
Interface Lanes Speed MTU Alias Oper Admin Type Asym PFC
----------- --------------- ------- ----- ------------ ------ ------- ------ ----------
Ethernet0 8 25G 9100 Ethernet1/1 up up SFP N/A
Ethernet1 9 25G 9100 Ethernet2/1 up up SFP N/A
Ethernet2 10 25G 9100 Ethernet3/1 down down N/A N/A
Ethernet3 11 25G 9100 Ethernet4/1 down down N/A N/A
Ethernet4 12 25G 9100 Ethernet5/1 down down N/A N/A
Ethernet5 13 25G 9100 Ethernet6/1 down down N/A N/A
Ethernet6 14 25G 9100 Ethernet7/1 down down N/A N/A
Ethernet7 15 25G 9100 Ethernet8/1 down down N/A N/A
Ethernet8 16 25G 9100 Ethernet9/1 down down N/A N/A
Ethernet9 17 25G 9100 Ethernet10/1 down down N/A N/A
Ethernet10 18 25G 9100 Ethernet11/1 down down N/A N/A
Ethernet11 19 25G 9100 Ethernet12/1 down down N/A N/A
Ethernet12 20 25G 9100 Ethernet13/1 down down N/A N/A
Ethernet13 21 25G 9100 Ethernet14/1 down down N/A N/A
Ethernet14 22 25G 9100 Ethernet15/1 down down N/A N/A
Ethernet15 23 25G 9100 Ethernet16/1 down down N/A N/A
Ethernet16 32 25G 9100 Ethernet17/1 down down N/A N/A
Ethernet17 33 25G 9100 Ethernet18/1 down down N/A N/A
Ethernet18 34 25G 9100 Ethernet19/1 down down N/A N/A
Ethernet19 35 25G 9100 Ethernet20/1 down down N/A N/A
Ethernet20 40 25G 9100 Ethernet21/1 down down N/A N/A
Ethernet21 41 25G 9100 Ethernet22/1 down down N/A N/A
Ethernet22 42 25G 9100 Ethernet23/1 down down N/A N/A
Ethernet23 43 25G 9100 Ethernet24/1 down down N/A N/A
Ethernet24 48 25G 9100 Ethernet25/1 down down N/A N/A
Ethernet25 49 25G 9100 Ethernet26/1 down down N/A N/A
Ethernet26 50 25G 9100 Ethernet27/1 down down N/A N/A
Ethernet27 51 25G 9100 Ethernet28/1 down down N/A N/A
Ethernet28 56 25G 9100 Ethernet29/1 down down N/A N/A
Ethernet29 57 25G 9100 Ethernet30/1 down down N/A N/A
Ethernet30 58 25G 9100 Ethernet31/1 down down N/A N/A
Ethernet31 59 25G 9100 Ethernet32/1 down down N/A N/A
Ethernet32 64 25G 9100 Ethernet33/1 down down N/A N/A
Ethernet33 65 25G 9100 Ethernet34/1 down down N/A N/A
Ethernet34 66 25G 9100 Ethernet35/1 down down N/A N/A
Ethernet35 67 25G 9100 Ethernet36/1 down down N/A N/A
Ethernet36 68 25G 9100 Ethernet37/1 down down N/A N/A
Ethernet37 69 25G 9100 Ethernet38/1 down down N/A N/A
Ethernet38 70 25G 9100 Ethernet39/1 down down N/A N/A
Ethernet39 71 25G 9100 Ethernet40/1 down down N/A N/A
Ethernet40 72 25G 9100 Ethernet41/1 down down N/A N/A
Ethernet41 73 25G 9100 Ethernet42/1 down down N/A N/A
Ethernet42 74 25G 9100 Ethernet43/1 down down N/A N/A
Ethernet43 75 25G 9100 Ethernet44/1 down down N/A N/A
Ethernet44 76 25G 9100 Ethernet45/1 down down N/A N/A
Ethernet45 77 25G 9100 Ethernet46/1 down down N/A N/A
Ethernet46 78 25G 9100 Ethernet47/1 down down N/A N/A
Ethernet47 79 25G 9100 Ethernet48/1 down down N/A N/A
Ethernet48 84,85,86,87 100G 9100 Ethernet49/1 up up QSFP28 N/A
Ethernet49 80,81,82,83 100G 9100 Ethernet50/1 up up QSFP28 N/A
Ethernet50 92,93,94,95 100G 9100 Ethernet51/1 down down N/A N/A
Ethernet51 88,89,90,91 100G 9100 Ethernet52/1 down down N/A N/A
Ethernet52 108,109,110,111 100G 9100 Ethernet53/1 down down N/A N/A
Ethernet53 104,105,106,107 100G 9100 Ethernet54/1 down down N/A N/A
Ethernet54 116,117,118,119 100G 9100 Ethernet55/1 down down N/A N/A
Ethernet55 112,113,114,115 100G 9100 Ethernet56/1 down down N/A N/A
root@switch1:~#
Backport of
54f137c105
According to 6.4.15 of IEEE 802.1AX-2014, Figure 6-22, the state that the
port is selected moves MUX state from DETACHED to ATTACHED.
But ATTACHED state does not mean that the port can send and receive user
frames. COLLECTING_DISTRIBUTION state is the state that the port can send
and receive user frames. To move MUX state from ATTACHED to
COLLECTING_DISTRIBUTION, the partner state should be sync as well as the
port selected.
In function lacp_port_actor_update(), only INFO_STATE_SYNCHRONIZATION
should be set to the actor.state when the port is selected.
INFO_STATE_COLLECTING and INFO_STATE_DISTRIBUTING should be set to false
with ATTACHED mode and set to true when INFO_STATE_SYNCHRONIZATION of
partner.state is set.
In function lacp_port_should_be_{enabled, disabled}(), we also need to
check the INFO_STATE_SYNCHRONIZATION bit of partner.state.
Signed-off-by: Hangbin Liu <liuhangbin@gmail.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
* [dockers]: Upgrade SNMP docker to stretch build
* Removed patch-> 0003-CHANGES-BUG-2743-snmpd-crashes-when-receiving-a-GetN.patch
* update platform-common submodule
* adding PyYAML package to stretch dockerfile
* Installing redis package via pip in stretch dockerfile
* again updating platform-common submodule
* revert back the snmpd version to 5.7.3+dfsg-1.5
* upgrading the snmpd version to 5.7.3+dfsg-1.7+deb9u1 with openssl backport support
* update sonic-snmpagent submodule
* purge libdpkg-perl package in Dockerfile
* revert back the snmpd version to 5.7.3+dfsg-1.5
* minor change in series file