Commit Graph

22 Commits

Author SHA1 Message Date
Kevin Wang
b8b7a0f4fc [Buffer] Separate buffer profile for Arista-7260CX3-Q64
Signed-off-by: Kevin Wang <shengkaiwang@microsoft.com>
2022-07-12 11:48:01 -07:00
bingwang-ms
ac86f71287
Add extra lossy PG profile for ports between T1 and T2 (#11157)
Signed-off-by: bingwang <wang.bing@microsoft.com>

Why I did it
This PR brings two changes

Add lossy PG profile for PG2 and PG6 on T1 for ports between T1 and T2.
After PR Update qos config to clear queues for bounced back traffic #10176 , the DSCP_TO_TC_MAP and TC_TO_PG_MAP is updated when remapping is enable

DSCP_TO_TC_MAP
Before	After	Why do this change
"2" : "1"	"2" : "2"	Only change for leaf router to map DSCP 2 to TC 2 as TC 2 will be used for lossless TC
"6" : "1"	"6" : "6"	Only change for leaf router to map DSCP 6 to TC 6 as TC 6 will be used for lossless TC

TC_TO_PRIORITY_GROUP_MAP
Before	After	Why do this change
"2" : "0"	"2" : "2"	Only change for leaf router to map TC 2 to PG 2 as PG 2 will be used for lossless PG
"6" : "0"	"6" : "6"	Only change for leaf router to map TC 6 to PG 6 as PG 6 will be used for lossless PG

So, we have two new lossy PGs (2 and 6) for the T2 facing ports on T1, and two new lossless PGs (2 and 6) for the T0 facing port on T1.
However, there is no lossy PG profile for the T2 facing ports on T1. The lossless PGs for ports between T1 and T0 have been handled by buffermgrd .Therefore, We need to add lossy PG profiles for T2 facing ports on T1.

We don't have this issue on T0 because PG 2 and PG 6 are lossless PGs, and there is no lossy traffic mapped to PG 2 and PG 6

Map port level TC7 to PG0
Before the PCBB change, DSCP48 -> TC 6 -> PG 0.
After the PCBB change, DSCP48 -> TC 7 -> PG 7
Actually, we can map TC7 to PG0 to save a lossy PG.

How I did it
Update the qos and buffer template.

How to verify it
Verified by UT.
2022-06-28 12:50:33 -07:00
zitingguo-ms
e2078627c7
[AN/LT][Fix bug]:enable phy_an_lt_msft attribute on some platforms (#11147) 2022-06-15 17:29:45 -07:00
Neetha John
453504f421
[qos]: Adjust 7260 buffer sizes to accomodate extra lossless queues (#11018)
Why I did it
As part of PCBB changes, we need to enable 2 extra lossless queues. The changes in this PR are done to adjust only the reserved sizes on Th2 for the additional 2 lossless queues
Calculations are done based on 40 downlinks for T1 and 16 uplinks for dual ToR

How to verify it
Verified that the rendering works fine on Th2 dut
Unit tests have been updated to reflect the modified buffer sizes when pcbb is enabled. There are existing testcases that will test the original buffer sizes when pcbb is disabled. With these changes, was able to build sonic-config-engine wheel successfully

Signed-off-by: Neetha John <nejo@microsoft.com>
2022-06-05 22:20:26 -07:00
Richard.Yu
a6c9e195df
[Tunnel PFC] Add property for tunnel PFC (#10962)
* [Tunnel PFC] Add property for tunnel PFC

Replace the config.bcm file with j2 template file
- Add 'sai_remap_prio_on_tnl_egress=1' property when device metadata local
- Host subtype is 'dualtor'
- Change sai.profile foe the new config.bcm.j2
2022-06-05 08:08:36 -07:00
bingwang-ms
1cc602c6af
Add two extra lossless queues for bounced back traffic (#10496)
Signed-off-by: bingwang <bingwang@microsoft.com>

Why I did it
This PR is to add two extra lossless queues for bounced back traffic.
HLD sonic-net/SONiC#950

SKUs include
Arista-7050CX3-32S-C32
Arista-7050CX3-32S-D48C8
Arista-7260CX3-D108C8
Arista-7260CX3-C64
Arista-7260CX3-Q64

How I did it
Update the buffers.json.j2 template and buffers_config.j2 template to generate new BUFFER_QUEUE table.

For T1 devices, queue 2 and queue 6 are set as lossless queues on T0 facing ports.
For T0 devices, queue 2 and queue 6 are set as lossless queues on T1 facing ports.
Queue 7 is added as a new lossy queue as DSCP 48 is mapped to TC 7, and then mapped into Queue 7

How to verify it
Verified by UT
Verified by coping the new template and generate buffer config with sonic-cfggen
2022-06-02 13:03:27 -07:00
Nikola Dancejic
f2acf952fb
[device config] Adding configuration for default route fallback (#10465)
* [device config] Adding configuration for default route fallback
* Set sai_tunnel_underlay_route_mode attribute to fallback to default route if more specific route is unavailable.
2022-04-12 14:43:03 -07:00
bingwang-ms
b9dd1df372
Update qos config to clear queues for bounced back traffic (#10176)
* Update qos config to clear queues for bounced back traffic

Signed-off-by: bingwang <bingwang@microsoft.com>
2022-04-05 22:32:25 +08:00
gechiang
ef457ab13f
Disable ALPM distributed hitbit thread that is used for debug purpose only but interfered with Other functional operations (#9199) 2021-11-09 07:21:57 -08:00
Ashok Daparthi-Dell
6cbdf11e53
SONIC QOS YANG - Remove qos tables field value refernce format (#7752)
Depends on Azure/sonic-utilities#1626
Depends on Azure/sonic-swss#1754

QOS tables in config db used ABNF format i.e "[TABLE_NAME|name] to refer fieldvalue to other qos tables.

Example:
Config DB:
"Ethernet92|3": {
"scheduler": "[SCHEDULER|scheduler.1]",
"wred_profile": "[WRED_PROFILE|AZURE_LOSSLESS]"
},
"Ethernet0|0": {
"profile": "[BUFFER_PROFILE|ingress_lossy_profile]"
},
"Ethernet0": {
"dscp_to_tc_map": "[DSCP_TO_TC_MAP|AZURE]",
"pfc_enable": "3,4",
"pfc_to_queue_map": "[MAP_PFC_PRIORITY_TO_QUEUE|AZURE]",
"tc_to_pg_map": "[TC_TO_PRIORITY_GROUP_MAP|AZURE]",
"tc_to_queue_map": "[TC_TO_QUEUE_MAP|AZURE]"
},

This format is not consistent with other DB schema followed in sonic.
And also this reference in DB is not required, This is taken care by YANG "leafref".

Removed this format from all platform files to consistent with other sonic db schema.
Example:
"Ethernet92|3": {
"scheduler": "scheduler.1",
"wred_profile": "AZURE_LOSSLESS"
},

Dependent pull requests:
#7752 - To modify platfrom files
#7281 - Yang model
Azure/sonic-utilities#1626 - DB migration
Azure/sonic-swss#1754 - swss change to remove ABNF format
2021-09-28 09:21:24 -07:00
gechiang
8e903f4566
BRCM Disable ACL Drop counted towards interface RX_DRP counters (#8382)
* BRCM Disable ACL Drop counted towards interface RX_DRP counters
2021-08-10 19:03:22 -07:00
gechiang
6fc279b7c1
Add BRCM SOC Property to not count ACL drops towards interface RX_DRP… (#7945)
* Add BRCM SOC Property to not count ACL drops towards interface RX_DRP counter for 7050CX3 and 7260CX3 DualToR platforms
2021-06-23 18:09:47 -07:00
Ying Xie
a42aa3d316
[MMU] define T1 MMU configuratino for Arista-7260CX3-Q64 (#7718)
Why I did it
Arista-7260CX3-Q64 is missing T1 MMU configuration.

How I did it
Define T1 MMU configuration for Arista-7260CX3-Q64.

Signed-off-by: Ying Xie <ying.xie@microsoft.com>
2021-05-27 08:20:07 -07:00
gechiang
6f65b42e4c
7260cx3 DualToR config.bcm support based on DualToR setting in device metadata at boot time (#7168)
* 7260cx3 DualToR config.bcm support based on DualToR setting in device metadata at boot time. 
For HWSKU Arista-7260CX3-C64 the MMU setting SOC for T0/T1 is also combined into the config.bcm.j2 logic so use just one config file and adding delta based on Switch Roles.
2021-03-31 14:23:24 -07:00
abdosi
a6a10f05b7
In SAI 3.5 by default we are supporting 256 Group with 64 Memeber each. (#5400)
However in SAI 3.7 default behaviout got changes to 128 Group and 128
    Memeber each.

    This change is to make sure we are using same ECMP Group/Memeber Per
    Group for 3.7 also so that behaviour is consistent.

Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
2020-09-22 11:21:12 -07:00
abdosi
b6efb49817
Update bcm soc property bcm_num_cos from 8 to 10 (#5314)
as needed by SAI 3.7 and above. Without this change
Warmboot fails from 3.5 to 3.7 as Braodcoam Datastructure
gets corrupted after warm-boot.

Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
2020-09-04 07:40:17 -07:00
Wenda Ni
0d2aa7fb5b [devices]: PG headroom change for Arista 7260 (#3600)
Signed-off-by: Wenda Ni <wenni@microsoft.com>
2019-10-15 06:03:48 -07:00
Ying Xie
eeeda28434
[bcm config] enable sram scan (#3558)
Per Broadcom's recommendations.

Signed-off-by: Ying Xie <ying.xie@microsoft.com>
2019-10-03 17:02:59 -07:00
Wenda Ni
7b0a5ba6ae Remove the divide by 4 operation to the under the hood SAI (#1532)
* Remove the divide by 4 operation to the under the hood SAI

This is to avoid the need and thus the confusion for application program to know
the mmu internal architecture

This change must have support from SAI change to reach the correct
config

Signed-off-by: Wenda <wenni@microsoft.com>

* Relegate the divide by 4 operation to the under the hood SAI for egress
lossless pool

Extend to 7060 and 6100

Signed-off-by: Wenda <wenni@microsoft.com>

* Add more TH/TH2 hwskus

Signed-off-by: Wenda Ni <wenni@microsoft.com>

* Update config test

Signed-off-by: Wenda Ni <wenni@microsoft.com>

* Add TH2 ingress lossy profile

Signed-off-by: Wenda Ni <wenni@microsoft.com>

* Move the divide by 4 operation to SAI internal

Signed-off-by: Wenda Ni <wenni@microsoft.com>

* [bcm SAI] Upgrade Broadcom SAI to version 3.5.3.1-15

- Broadcom SAI 3.5 GA release 20190924.

Signed-off-by: Ying Xie <ying.xie@microsoft.com>
2019-09-25 15:57:07 -07:00
Ying Xie
99b0b349bf
[mmu] add mmu_init_config to HWSKU Arista-7260CX3-Q64 (#3334)
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
2019-08-13 17:31:25 -07:00
zzhiyuan
0ef7dc5d98 [devices]: Update Arista 7260CX3-64 10G SFP tuning (#3151) 2019-07-16 08:42:55 -07:00
Ying Xie
f98bec41c7
[HWSKU] Define HWSKU Arista-7260CX3-Q64 and Arista-7260CX3-Q44 (#2562)
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
2019-02-14 11:27:15 -08:00