Fix watchdog reboot cause for wolverine linecard
Fix PSU fan speed of 0% by adding max RPM to most psu descriptions
Add product DCS-7060DX5-64
Add product DCS-7060DX5-32
catch system error and log as warning level instead of
error level in case interface was already deleted
Signed-off-by: Gokulnath-Raja <Gokulnath_R@dell.com>
The only platforms that currently need the stretch slave container are
innovium and nephos, and both are not building with the current code due
to other issues. All other platforms only need buster and bullseye slave
containers.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
- Why I did it
Mellanox syncd container will be based on Debian iproute2 plus patches instead of Nvidia internal version of iproute2
- How I did it
Download iproute2 from Debian repository, apply patches and compile to create a new target.
The target is then deployed in syncd container of Mellanox switches only.
The new target is called IPROUTE2_MLNX.
- How to verify it
Compile and load on switch, verify interfaces network devices created successfully.
Verify LLDP shows connections to neighbors.
Verify ping between 2 hosts over 2 router ports is successful.
Update sonic-sairedis submodule pointer to include the following:
* 61cf1ce Revert Ignore removing switch for mellanox platform due to known limitation (1216) ([#1232](https://github.com/sonic-net/sonic-sairedis/pull/1232))
Signed-off-by: dprital <drorp@nvidia.com>
#### Why I did it
Enhance the error message output mechanism during swss docker creating
#### How I did it
Capture the output to stderr of `sonic-cfggen` and output it using `echo` to make sure the error message will be logged in syslog.
#### How to verify it
Manually test
Install python-redis package to docker containers
#### Why I did it
This this bug: https://github.com/sonic-net/sonic-buildimage/issues/14531
The 'flush_unused_database' is part of docker-database, and docker-database does not install python-redis package by itself. it's using redis installed by sonic-py-swsssdk.
So after remove sonic-py-swsssdk from container, this script break.
To this this bug and avoid similer bug happen again, install python-redis to docker containers which removed sonic-py-swsssdk .
#### How I did it
Install python-redis to containers.
#### How to verify it
Pass all UT.
Create new UT to cover this scenario: https://github.com/sonic-net/sonic-mgmt/pull/8032
#### Description for the changelog
Improve sudo cat command for RO user.
Improve sudo cat command for RO user.
#### Why I did it
RO user can use sudo command show none syslog files.
#### How I did it
Improve sudo cat command for RO user.
#### How to verify it
Pass all UT.
Manually check fixed code work correctly.
#### Description for the changelog
Improve sudo cat command for RO user.
Why I did it
After sonic-install install a new image, print_menu is set echo without any data. No image info between Hit any key to stop autoboot: 0 and Start USB
Board configuration detected:
Net:
| port | Interface | PHY address |
|--------|-----------|--------------|
No ethernet found.
Hit any key to stop autoboot: 0
(Re)start USB...
USB0: Port (usbActive) : 0 Interface (usbType = 2) : USB EHCI 1.00
scanning bus 0 for devices... 3 USB Device(s) found
scanning usb for storage devices... 0 Storage Device(s) found
How I did it
The fw_setenv print_menu is missing the double quotes. That causes the value is truncated. Using double quotes to in the environment setting.
How to verify it
Install new image with this fix. And reboot the system. The following section should be shown:
Signed-off-by: mlok <marty.lok@nokia.com>
[S6100] Improve S6100 serial-getty monitor, wait and re-check when getty not running to avoid false alert.
#### Why I did it
On S6100, the serial-getty service some time can't auto-restart by systemd. So there is a monit unit to check serial-getty service status and restart it.
However, this monit will report false alert, because in most case when serial-getty not running, systemd can restart it successfully.
To avoid the false alert, improve the monitor to wait and re-check.
Steps to reproduce this issue:
1. User login to device via console, and keep the connection.
2. User login to device via SSH, check the serial-getty@ttyS1.service service, it's running.
3. Run 'monit reload' from SSH connection.
4. Check syslog 1 minutes later, there will be false alert: ' 'serial-getty' process is not running'
#### How I did it
Add check-getty.sh script to recheck again later when getty service not running.
And update monit unit to check serial-getty service status with this script to avoid false alert.
#### How to verify it
Pass all UT.
Manually check fixed code work correctly:
```
admin@***:~$ sudo systemctl stop serial-getty@ttyS1.service
admin@***:~$ sudo /usr/local/bin/check-getty.sh
admin@***:~$ echo $?
1
admin@***:~$ sudo systemctl status serial-getty@ttyS1.service
● serial-getty@ttyS1.service - Serial Getty on ttyS1
Loaded: loaded (/lib/systemd/system/serial-getty@.service; enabled-runtime; vendor preset: enabled)
Active: inactive (dead) since Tue 2023-03-28 07:15:21 UTC; 1min 13s ago
admin@***:~$ sudo /usr/local/bin/check-getty.sh
admin@***:~$ echo $?
0
admin@***:~$ sudo systemctl status serial-getty@ttyS1.service
● serial-getty@ttyS1.service - Serial Getty on ttyS1
Loaded: loaded (/lib/systemd/system/serial-getty@.service; enabled-runtime; vendor preset: enabled)
```
syslog:
```
Mar 28 07:10:37.597458 *** INFO systemd[1]: serial-getty@ttyS1.service: Succeeded.
Mar 28 07:12:43.010550 *** ERR monit[593]: 'serial-getty' status failed (1) -- no output
Mar 28 07:12:43.010744 *** INFO monit[593]: 'serial-getty' trying to restart
Mar 28 07:12:43.010846 *** INFO monit[593]: 'serial-getty' stop: '/bin/systemctl stop serial-getty@ttyS1.service'
Mar 28 07:12:43.132172 *** INFO monit[593]: 'serial-getty' start: '/bin/systemctl start serial-getty@ttyS1.service'
Mar 28 07:13:43.286276 *** INFO monit[593]: 'serial-getty' status succeeded (0) -- no output
```
#### Description for the changelog
[S6100] Improve S6100 serial-getty monitor.
#### Ensure to add label/tag for the feature raised. example - PR#2174 under sonic-utilities repo. where, Generic Config and Update feature has been labelled as GCU.