- Why I did it
To implement Syslog Source IP feature based on HLD: https://github.com/sonic-net/SONiC/pull/1002
- How I did it
Added the relevant yang model
- How to verify it
Added unit test
Signed-off-by: Nazarii Hnydyn <nazariig@nvidia.com>
#### Why I did it
Support the following tables which were introduced during dynamic buffer calculation
- LOSSLESS_TRAFFIC_PATTERN
- DEFAULT_LOSSLESS_BUFFER_PARAMETER
#### How I did it
- LOSSLESS_TRAFFIC_PATTERN
|name|type|range|mandatory|description|
|---|---|---|---|---|
|mtu|uint16|64~10240|true|The maximum packet size of a lossless packet|
|small_packet_percentage|uint8|0~100|true|The percentage of small packet|
- DEFAULT_LOSSLESS_BUFFER_PARAMETER
|name|type|range|mandatory|description|
|---|---|---|---|---|
|default_dynamic_th|int8|-8~7|true|The default dynamic_th for all buffer profiles that are dynamically generated for lossless PG|
|over_subscribe_ratio|uint16|-|false|The oversubscribe ratio for shared headroom pool.|
|||||Semantically, the upper bound is the number of physical ports but it can not be represented in the yang module. So we keep the upper bound open. As the type is (signed) integer whose lower bound is 0 by nature, we do not need to specify the range.|
#### How to verify it
Run unit test
Update the bcm config file system_ref_core_clock_khz param to handlesystems with J2cplus linecards.
We need system_ref_core_clock_khz to be set to 1600000 for supporting j2 and j2cplus linecards on the same chassis.
#### Why I did it
There might be a case where service checker periodic operation determined that specific container is running but when it tries to perform an operation on it, it was already closed by the user. This is a valid flow and we should not log an error message, informative warning is enough.
#### How I did it
I reduce log severity.
#### How to verify it
I verified it manually.
The return statement does not end with a semicolon in function scheduler_csm_socket_cleanup, which generates a compilation warning and may cause unexpected problems.
Signed-off-by: ouxiaolong <ouxiaolong@asterfusion.com>
05c79ef Fix header for the output table following 'show ipv6 interface' command (#2219)
fc5633f increase coverage to 80% (#2214)
c0dffba [config][muxcable] fix minor config DB logic issue (#2210)
a50eca0 [generic-config-updater] Add NTP validator (#2212)
a3d1345 [gendump] Add Support to dump BCM-DNX commands (#1813)
bb185d5 [yang] remove mistakenly added parameter for 'get_module_name' (#2193)
2cccf26 [counters] skip showing counters that are not enabled (#2199)
ff05bc8 [config][muxcable] Add support for displaying soc_ipv4 and cable_type in config/show muxcable commands (#2189)
3197f39 Add check to not allow deleting PO if its member of vlan. (#2141)
2513da1 [dump] Optimized dump state cli and modified tests to not use common data (#2175)
9e310e5 Fix sonic-installer and 'show version' command crash when database docker not running issue. (#2183)
4ad70b9 [sonic-installer] use host docker startup arguments when running dockerd in chroot (#2179)
3d3c89b fix for non-coherent cmis modules (#2163)
2054680 [subinterface] Fix route add command to accept subinterface as dev (#2180)
5383e92 [subinterface]Avoid removing the subinterface when last configured ip is removed (#2181)
f5af780 [GCU] Handling type1 lists (#2171)
4516179 [yang] extend ConfigMgmt constructor to pass YANG options (#2118)
2f53bd4 [dump] implement ACL modules (#2153)
494dd62 show commands for SYSTEM READY (#1851)
4fc09b1 [GCU] Handling non-compliant leaf-list with string values (#2174)
675c7b6 Add sonic-delayed.target to Application Extension .timer file generator (#2176)
c587933 [portconfig] Allow to configure interface mtu for physical ports only
9881f3e Broadcast Unknown-multicast and Unknown-unicast Storm-control (#928)
88286cb sonic-utils: initial support for link-training (#2071)
- Why I did it
When LLDP is disabled through feature command, it gets spawned after reboot.
- How I did it
In syncd.sh check if the service is enabled before spawning automatically during cold reboot.
- How to verify it
Disable lldp feature. Perform cold reboot and verify its not spawned.
* [Interfaces] Modify template to support multiple management interfaces
* Modify minigraph to process interfaces in sorted order
Signed-off-by: Ubuntu <gechen@gechen-sonic-dev.d0r25nej54guppclip4gpy5b5a.jx.internal.cloudapp.net>
* Add UT minigraph
Signed-off-by: Ubuntu <gechen@gechen-sonic-dev.d0r25nej54guppclip4gpy5b5a.jx.internal.cloudapp.net>
* make case insensitve comparison
Signed-off-by: George Chen <gechen@microsoft.com>
* Use natural sort
Signed-off-by: George Chen <gechen@microsoft.com>
Co-authored-by: Ubuntu <gechen@gechen-sonic-dev.d0r25nej54guppclip4gpy5b5a.jx.internal.cloudapp.net>
Why I did it
The t0-sonic pool has been fixed, so add it back to azp checker.
How I did it
Remove continueOnError in run-test-template.yml.
Signed-off-by: Ze Gan <ganze718@gmail.com>
Why I did it
Support to use symbol links in platform folder to reduce the image size.
The current solution is to copy each lazy installation targets (xxx.deb files) to each of the folders in the platform folder. The size will keep growing when more and more packages added in the platform folder. For cisco-8000 as an example, the size will be up to 2G, while most of them are duplicate packages in the platform folder.
How I did it
Create a new folder in platform/common, all the deb packages are copied to the folder, any other folders where use the packages are the symbol links to the common folder.
Why platform.tar?
We have implemented a patch for it, see #10775, but the problem is the the onie use really old unzip version, cannot support the symbol links.
The current solution is similar to the PR 10775, but make the platform folder into a tar package, which can be supported by onie. During the installation, the package.tar will be extracted to the original folder and removed.
* Support new platform SN2201 and RJ45 port
Signed-off-by: Kebo Liu <kebol@nvidia.com>
* remove unused import and redundant function
Signed-off-by: Kebo Liu <kebol@nvidia.com>
* fix error introduced by rebase
Signed-off-by: Kebo Liu <kebol@nvidia.com>
* Revert the special handling of RJ45 ports (#56)
* Revert the special handling of RJ45 ports
sfp.py
sfp_event.py
chassis.py
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Remove deadcode
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Support CPLD update for SN2201
A new class is introduced, deriving from ComponentCPLD and overloading _install_firmware
Change _install_firmware from private (starting with __) to protected, making it overloadable
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Initialize component BIOS/CPLD
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Remove swb_amb which doesn't on DVT board any more
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Remove the unexisted sensor - switch board ambient - from platform.json
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Do not report error on receiving unknown status on RJ45 ports
Translate it to disconnect for RJ45 ports
Report error for xSFP ports
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Add reinit for RJ45 to avoid exception
Signed-off-by: Stephen Sun <stephens@nvidia.com>
Co-authored-by: Stephen Sun <5379172+stephenxs@users.noreply.github.com>
Co-authored-by: Stephen Sun <stephens@nvidia.com>
* [sflow + dropmon] added INCLUDE_SFLOW_DROPMON flag, added patches for hsflowd
*Added a capability of monitoring dropped packets for the sFlow daemon in order to improve network - monitoring, diagnostic, and troubleshooting. The drop monitor service allows the sFlow daemon to export another type of sample - dropped packets as Discard samples alongside Counter samples and Packet Flow samples.
Signed-off-by: Vadym Hlushko <vadymh@nvidia.com>
- Why I did it
Need to execute mlxreg inside pmon docker
- How I did it
Add MFT package to pmon Makefile
- How to verify it
Install image, go to pmon : docker exec -it pmon bash, exec mlxreg
Verifiy warm, fast and cold reboot while MFT is being called in pmon constantly
Signed-off-by: Andriy Yurkiv <ayurkiv@nvidia.com>
- Why I did it
An issue is encountered when a value "False" is written for a feature in "check_up_status" field, which does not pass YANG validation.
- How I did it
We usually use stypes::boolean_type for such fields, even in this YANG model. This custom type, supports "False" value.
- How to verify it
Write "False" in "check_up_status" field and see if YANG validation passes.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
Signed-off-by: Yong Zhao yozhao@microsoft.com
Why I did it
This PR aims to fix an issue (#10088) by enhancing the script memory_checker.
Specifically, if container is not created successfully during device is booted/rebooted, then memory_checker do not need check its memory usage.
How I did it
In the script memory_checker, a function is added to get names of running containers. If the specified container name is not in current running container list, then this script will exit without checking its memory usage.
How to verify it
I tested on a lab device by following the steps:
Stops telemetry container with command sudo systemctl stop telemetry.service
Removes telemetry container with command docker rm telemetry
Checks whether the script memory_checker ran by Monit will generate the syslog message saying it will exit without checking memory usage of telemetry.
example:
├── folderA
│ ├── fileA (skip vstest)
│ ├── fileB
│ └── fileC
If we want to skip vstest when changing /folderA/fileA, and not skip vstest when changing fileB or fileC.
vstest-include:
^folderA/fileA
vstest-exclude:
^folderA
Why I did it
S5212F - Platform API 2.0 changes
S5224F - Platform API 2.0 changes
How I did it
Implemented the functional API's needed for Platform API 2.0
Added media_settings.json, pcie.yaml, platform.json, system_health_monitoring_config.json files.
How to verify it
Used the API 2.0 test suite to validate the test cases.
Why I did it
This change adds the support for Arista 7060dx5_64s and 7060px5_64s
How I did it
How to verify it
We verified the platform driver is working and the ports are up on 7060dx5_64s and 7060px5_64s.
Add most configuration files for the DCS-7050PX4-32S and DCS-7050DX4-32S.
This review only contains platform configuration files, dataplane ones will follow in future change.
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
- Why I did it
Recent change to delay PMON service in case of fast/warm reboot introduce an issue when restarting only SWSS service after fast/warm reboot for Nvidia platform.
Since the timer is triggered only when the system boot, in a scenario when the system is after a fast/warm reboot and the user restart SWSS service, as part of syncd.sh script, PMON service will stop but the timer will not start again.
- How I did it
On syncd.sh script, in case of fast/warm indication, check if pmon.timer is running.
If it is running it means we are at the first boot and continue normally.
If it is not running, meaning the service was restarted, start the timer to keep the system behavior consistent.
- How to verify it
Run fast/warm reboot.
service swss restart.
Observe PMON service starting.
Signed-off-by: Shlomi Bitton <shlomibi@nvidia.com>
Why I did it
The docker storage driver vfs is not a good option for build, it uses the “deep copy” when building a new layer, leads to lower performance and more space used on disk than other storage drivers.
A better docker storage driver is the default one overlay2, it is a modern union filesystem.
#### Why I did it
SSHD keepalive timeout feature not enabled on sonic.
#### How I did it
Enable SSHD keepalive timeout feature by set ClientAliveCountMax to 1.
#### How to verify it
Pass All E2E test case.
Manually test with following steps:
1. Change config and restart sshd
2. Connect a ssh with -vvv option to show debug message
3. Get running ssh by command and stop it:
```
azureuser@liuh-dev-vm-02:~$ ps -auxww | grep vvv
azureus+ 1614153 0.0 0.0 12244 6004 pts/1S+ 15:48 0:00 ssh admin@10.250.0.101 -vvv
azureus+ 1615570 0.0 0.0 8168 2424 pts/3S+ 15:49 0:00 grep --color=auto vvv
azureuser@liuh-dev-vm-02:~$ kill -Stop 1614153
```
4. Check TCP status from server side with ss command:
https://man7.org/linux/man-pages/man8/ss.8.html
```
admin@vlab-01:~$ ss | grep -i ssh
tcp ESTAB 0 010.250.0.101:ssh 10.250.0.1:58150
tcp FIN-WAIT-2 0 010.250.0.101:ssh 10.250.0.1:58164
tcp ESTAB 0 010.250.0.101:ssh 10.250.0.1:57978
```
FIN-WAIT-2 means server already terminate the connection and wait for client response:
https://kb.iu.edu/d/ajmi
. FIN-WAIT-2 <-- <SEQ=300><ACK=101><CTL=ACK> <-- CLOSE-WAIT
5. Check again later will show the session been complete closed:
```
admin@vlab-01:~$ ss | grep -i ssh
tcp ESTAB 0 010.250.0.101:ssh 10.250.0.1:58150
tcp ESTAB 0 010.250.0.101:ssh 10.250.0.1:57978
```
Why I did it
Added support for the device Z9432F
How I did it
Implemented the support for the platform Z9432F
Switch Vendor: DellEMC
Switch SKU: Z9432F-ON
ASIC Vendor: Broadcom
SONiC Image: sonic-broadcom.bin
Why I did it
To address internal build failures where the cable len for some of the skus is set to 300m for all tiers.
How I did it
For the buffers test, generate a new output file based off the original expected output with CABLE_LENGTH table updated to use 300m. In the comparison logic, compare against each of the expected output files and if any matches, the testcase is set to pass
Signed-off-by: Neetha John <nejo@microsoft.com>
* 48cccb4 2022-06-13 | do not use sai_query_api_version if vendor sai does not support in VendorSai.cpp (#1064) (HEAD, origin/master, origin/HEAD) [Guohan Lu]
* 9b0f773 2022-06-13 | [vslib]: Fixbug in cleanup MACsec device (#1059) [Ze Gan]
* cdf9427 2022-06-11 | No sai api version check if vendor sai does not support (#1063) (HEAD, origin/master, origin/HEAD) [Guohan Lu]
* 3964cf1 2022-06-09 | [counter] Fix port flex counter (#1052) [Junhua Zhai]
* 2231b7a 2022-06-03 | Purge package sonic-db-cli which depends on libswsscommon (#1057) [Qi Luo]
* 7aa09b9 2022-06-01 | Set PR diff code coverage threshold to 80% (#1039) [Kamil Cudnik]
* 66a29bc 2022-05-18 | [syncd] Use vendor SAI instead of direct SAI api (#1042) [Kamil Cudnik]
* 564bea7 2022-05-18 | [ci] Paralize azure pipeline (#1040) [Shilong Liu]
* 57ed180 2022-05-17 | [configure.ac] implement SAI API version check (#1000) [Stepan Blyshchak]
* 8894dc7 2022-05-17 | vslib: add support for read-only port capabilities (#1038) [Dante (Kuo-Jung) Su]
* 42af975 2022-04-29 | [vslib]: Update packet number of MACsec SA at runtime (#1007) [Ze Gan]
Signed-off-by: Guohan Lu <lguohan@gmail.com>
This fixes the build for armhf to be able to use '/device///installer.conf' files. Specifically, armhf needs support to be able to change the size of /var/log/ directory. It is hardcoded to 512 bytes on all armhf platforms currently. This change will allow any armhf platform to be able to use an installer.conf file to customize the installed image.
Why I did it
The dhcp_graph_url used by internal service is always set as "N/A". So we can make the updategraph logic short.
How I did it
Shorten 'if statement' logic for /tmp/dhcp_graph_url