It's been reported that accton fan monitor process keeps consuming memory after few days.
The amount of memory occupied increases in linear and never leased.
Signed-off-by: roy_lee <roy_lee@edge-core.com>
**- Why I did it**
- The thermalctld daemon on the Pmon docker requires support from the thermal manager API.
**- How I did it**
- Removed the old function for detecting a faulty fan.
- Removed the old function for detecting excess temperature.
- Implement thermal_manager APIs based on ThermalManagerBase
- Implement thermal_conditions APIs based on ThermalPolicyConditionBase
- Implement thermal_actions APIs based on ThermalPolicyActionBase
- Implement thermal_info APIs based on ThermalPolicyInfoBase
- Add thermal_policy.json
[multi_asic][vs]: Add dependency in teamd service to start after topology service.
- Why I did it
In multi-asic VS, topology service is run after database service to set up the internal asic topology.
swss and syncd have a dependency to start after topology service is run so that the interfaces are moved to right namespace and created in the right namespace. In case of multi-asic vs, during the initial boot up, when there is no configuration added, teamd service starts and swss/syncd do not start as topology service does not start. Upon loading configuration using config_db or minigraph, swss and sycnd start up , but teamd is not restarted as swss is not stopped and started. This causes teamd to be in a bad state and requires a reload of config.
- How I did it
Add dependency in teamd service to start after topology service is completed.
- How to verify it
No change in single asic vs or platform.
No change in multi-asic regular image.
Change only in multi-asic VS. Bring up a multi-asic VS image without any configration, teamd service will fail to start due to dependency failure. Load minigraph, start topology service, load configuration, ensure all services come up.
Signed-off-by: SuvarnaMeenakshi <sumeenak@microsoft.com>
- Introduced TS common file in docker as well and moved common functions.
- TSA/B/C scripts run only in BGP instances for front end ASICs.
In addition skip enforcing it on route maps used between internal BGP sessions.
admin@str--acs-1:~$ sudo /usr/bin/TSA
System Mode: Normal -> Maintenance
and in case of Multi-ASIC
admin@str--acs-1:~$ sudo /usr/bin/TSA
BGP0 : System Mode: Normal -> Maintenance
BGP1 : System Mode: Normal -> Maintenance
BGP2 : System Mode: Normal -> Maintenance
When large number of port channels (more than 64) is configured, a config reload command might ends with not all port channel configured and up. Further debug shows that unloading the port channels on the ASIC driver take a lot of time.
With the change, deleting all port channels before the syncd restart will free resources better and the ASIC driver will unload all netdev fast and the operation will execute properly.
Bring in a fix for thermal shutdown observed while executing warm-reboot:
- All | prevent FW access during ISSU
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
Fix the build failure of asyncsnmp-2.1.0-py3-none-any.whl .
Looks like a recent update on https://packages.debian.org/stretch/libpython3.5-stdlib
3.5.3-1+deb9u1 -> 3.5.3-1+deb9u3 break the build command python3 setup.py bdist_wheel
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
Fix#5812
LLDP conf Jinja2 Template does not verify IPv4 address and can use IPv6 version. This issue does not effect control LLDP daemon. Issue can be reproduced via `test_snmp_lldp` test. LLDP conf Jinja2 Template selects first item from the list of mgmt interfaces.
TESTBED_1 LLDP conf
```
configure ports eth0 lldp portidsubtype local eth0
configure system ip management pattern FC00:3::32
configure system hostname dut-1
```
TESTBED_2 LLDP conf
```
configure ports eth0 lldp portidsubtype local eth0
configure system ip management pattern 10.22.24.61
configure system hostname dut-2
```
TESTBED_1 MGMT_INTERFACE
```
$ redis-cli -n 4 keys "*" | grep MGMT_INTERFACE
MGMT_INTERFACE|eth0|10.22.24.53/23
MGMT_INTERFACE|eth0|FC00:3::32/64
```
TESTBED_2 MGMT_INTERFACE
```
$ redis-cli -n 4 keys "*" | grep MGMT_INTERFACE
MGMT_INTERFACE|eth0|FC00:3::32/64
MGMT_INTERFACE|eth0|10.22.24.61/23
```
Signed-off-by: Petro Bratash <petrox.bratash@intel.com>
To have the following fixes:
* All | Port status remains down after warm boot and flapping the port on peer side
* All | LAG HASH | IPv6 SRC_IP is not accounted in LAG hashing [
* All | ASIC driver | Kernel crash observed when driver reload is initiated before it fully loaded
* Spectrum-3 | Buffer | In lossless configuration, headroom is been evicted only when the shared buffers is free
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
On the DCS-7060CX-32S, a SEU can happen on a CPLD which by default would reboot the platform.
Other SEU scenarios are already handled but this one was missed since it's specific to this platform.
It's a pretty rare case which will now be reported in the syslog the same way others are.
Include SAI bug fixes:
Apply device MAC on port host interface when port is removed from LAG.
[Shared Headroom]: fixed watermark handling for SHP flow
Decrease verbosity of policer unbind message when no policer is attached
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
When we add allow-list key with action above route-map gets updated . For eg if we add deny action above template will become to no-export community. Now if we delete the key Issue is we still keep the no-export and do not move back to drop community.
This PR fixes this issue by rolling back default route-map community value back to constants.yml default action.
** Why I did it **
Disable SDK extended dump due to issue found
** How I did it **
Update SAI submodule
** How to verify it **
Verify the SDK extended dump is not called.
Signed-off-by: Eran Dahan <erand@nvidia.com>
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
- Why I did it
The command sudo ip netns identify <pid> is used in function get_current_namespace
to check in the cli command is running in host context or within a namespace.
This function is used for every CLI command and command sudo ip netns identify <pid> needs to be added in sudoer files to allow users with RO access to run show cli commands
This problem is not there on single asic platforms.
- How I did it
Add ip netns identify [0-9]* to sudoers file.
d324eaec945081f8718468b39a8cf12dae965fd5 (HEAD -> 201911, origin/201911) [PFCWD] Fix 'start' pfcwd command (#1345)
235c61cccbbbb1f948f53b561c98888681b7071a [ecnconfig] handle backend port names when extracting port I/F ID from the port name (#1361)
7f5c3b497148fdd8e710131c5ac3f9f0a5f2cddf Drop explict 3 seconds pause between two object updates/deletes. (#1359)
12c899207917751eac719916be69c0078671963d add vlan_intf_object only if there are ipv4 or ipv6 mappings (#1377)
52ce2c32bf4e267d043a739641f5eefba3f3910f Add subcommand description to interfaces counters (#1373)
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan arlakshm@microsoft.com
- Why I did it
This PR has the changes to support having different swss.rec and sairedis.rec for each asic.
The logrotate script is updated as well
- How I did it
Update the orchagent.sh script to use the logfile name options in these PRs(Azure/sonic-swss#1546 and Azure/sonic-sairedis#747)
In multi asic platforms the record files will be different for each asic, with the format swss.asic{x}.rec and sairedis.asic{x}.rec
Update the logrotate script for multiasic platform .
* Fix exception in bgpmon caused by duplicate keys
It is possible that BGP neighbors in IPv4 and IPv6 address families
share the same name (such as bgp monitor). However, such case is not
handled in bgpmon, and an Exception will be raised. This commit will
address the issue by Using set instead of list to avoid duplicate keys.
Following changes were done for ebtables:
- Support for Multi-asic platforms. Ebtable filters are installed in namespace for multi-asic and not host. On Single asic installed on host.
- For Multi-asic platforms we don't want to install on host otherwise Namespace-to-Namespace communication does not happens since ARP Request are not forwarded.
- Updated to use text file to restore ebtables rules then the binary format. Rules are restore as part of Database docker init instead of rc.local
- Removed the ebtable service files for buster as not needed as filters are restored/installed as part of database docker init.
All the binaries are pre-installed with ebtables* binary are same as ebatbles-legacy-*
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
Issue: Binary ebtables config file is CPU arch dependent
Fix: Load the text config during firsttime boot and
Generate the binary persistent atomic file
Signed-off-by: Antony Rheneus <arheneus@marvell.com>
when parallel build is enabled, both docker-fpm-frr and docker-syncd-brcm
is built at the same time, docker-fpm-frr requires swss which requires to
install libsaivs-dev. docker-syncd-brcm requires syncd package which requires
to install libsaibcm-dev.
since libsaivs-dev and libsaibcm-dev install the sai header in the same
location, these two packages cannot be installed at the same time. Therefore,
we need to serialize the build between these two packages. Simply uninstall
the conflict package is not enough to solve this issue. The correct solution
is to have one package wait for another package to be uninstalled.
For example, if syncd is built first, then it will install libsaibcm-dev.
Meanwhile, if the swss build job starts and tries to install libsaivs-dev,
it will first try to query if libsaibcm-dev is installed or not. if it is
installed, then it will wait until libsaibcm-dev is uninstalled. After syncd
job is finished, it will uninstall libsaibcm-dev and swss build job will be
unblocked.
To solve this issue, _UNINSTALLS is introduced to uninstall a package that
is no longer needed and to allow blocked job to continue.
Signed-off-by: Guohan Lu <lguohan@gmail.com>
backport c4b5b002c3
make swss build depends only on libsairedis instead of syncd. This allows to build swss without depending
on vendor sai library.
Currently, libsairedis build also buils syncd which requires vendor SAI lib. This makes difficult to build
swss docker in buster while still keeping syncd docker in stretch, as swss requires libsairedis which also
build syncd and requires vendor to provide SAI for buster. As swss docker does not really contain syncd
binary, so it is not necessary to build syncd for swss docker.
[submodule]: update sonic-sairedis
1e42517996bfe41ac58d4c25ee3f93502befcb9d (HEAD -> 201911) [build]: add option to build without syncd
Signed-off-by: Guohan Lu <lguohan@gmail.com>
**- Why I did it**
There is a preference to use thermalctld instead of fancontrol for 201911 release branch. The Arista platform submodule updates and thermal policies in the platforms will allow Arista devices to use thermalctld instead of fancontrol.
**- How I did it**
I cherry-picked the necessary commits from master branch for sonic-platform-modules-arista into 201911 branch. I've also added the file to skip fancontrol and added the thermal policies json.
**- How to verify it**
On Gardena, Upperlake, Clearlake, and Lodoga thermalctld is up and running with no errors. Fans show ~29%.
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
In order to prevent "mlxsw_minimal" driver accessing ASIC during in
service firmware upgrade flow, SDK will raise "OFFLINE" 'udev' event
at early beginning of such flow. When this event is received,
hw-managemnet will remove "mlxsw_minimal" driver.
There is no need to implement opposite "ONLINE" event, since this flow
is ended up with "kexec".
Signed-off-by: Kebo Liu <kebol@nvidia.com>
Bugs fixes:
All | Kernel | During system reload when CPU is loaded with heavy traffic, a Kernel Panic may occur.
All | Modules, Port split | FW stuck when device rebooted with locked Optical Transceivers in split mode
Spectrum-3 | PFC | On Spectrum-3 systems, slow reaction time to Rx pause packets on 40GbE ports may lead to buffer overflow on servers.
Spectrum-3 | SN4700, Port Split | On rare occasion SN4700, conducting 100G split (4x25G) in NRZ when splitter port 1 or 2 are down, ports 3 and 4 will also go down.
Enahncments:
All | Kernel | new notification on ISSU start, so other kernel drivers can disable any interface to ASIC
Signed-off-by: Kebo Liu <kebol@nvidia.com>
Recent changes brought l2 vlan concept which do not have DHCP
clients behind them and so DHCP relay is not required. Also,
dhcpmon fails to launch on those vlans as their interfaces
lack IP addresses. This PR limit launch of both DHCP relay
and dhcpmon to L3 vlans only.
singed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>