Commit Graph

1134 Commits

Author SHA1 Message Date
Dror Prital
d5bd2dd6bf
[202205] [Mellanox] update NVIDIA copyright header for added files (#12126)
- Why I did it
Add NVIDIA Copyright header for new "NVIDIA" files

- How I did it
Add the copyright header as remark at the head of the file
2022-09-22 19:08:08 +03:00
Junhua Zhai
5479892d1b [PikeZ] Update port alias in Arista-720DT-48S (#12086)
Fix #12037, by following HLD https://github.com/sonic-net/SONiC/blob/master/doc/sonic-port-name.md.
2022-09-21 21:19:14 +00:00
Samuel Angebault
366ded2936 Implement ssd_util plugin for Arista products (#11981)
Why I did it
Some Arista products do not have an SSD but use an eMMC instead.
The SsdUtil plugin is therefore extended to support both.

How I did it
Implemented ssd_util.py platform plugin loaded by ssdutil.
This plugin fallback to the default SONiC implementation if the arista one can't be found.

How to verify it
Run show platform ssdhealth on a product with an eMMC
2022-09-21 21:16:03 +00:00
Mai Bui
a63af72142 [device/ruijie] Mitigation for security vulnerability #11779
Signed-off-by: maipbui maibui@microsoft.com
Why I did it
The xml.etree.ElementTree module is not secure against maliciously constructed data.
How I did it
Remove xml. Use lxml XML parsers package that prevent potentially malicious operation.
2022-09-21 21:14:14 +00:00
Maxime Lorrillere
458b12b4af [Chassis][Voq]Configure midplane network on supervisor (#11725)
Multi-asic Docker instances are created behind Docker's default bridge
which doesn't allow talking to other Docker instances that are in the
host network (like database-chassis).

On linecards, we configure midplane interfaces to let per-asic docker
containers talk to CHASSIS_DB on the supervisor through internal chassis
network.

On the supervisor we don't need to use chassis internal network, but we
still need a similar setup in order to allow fabric containers to talk
to database-chassis
2022-09-21 21:12:40 +00:00
bingwang-ms
96588d20e0 Map TC6 to Queue 1 for regular traffic (#11904)
Why I did it
This PR is to update TC_TO_QUEUE_MAP|AZURE for SKU Arista-7050CX3-32S-D48C8 and Arista-7260CX3 T0.

The change is only to align the TC_TO_QUEUE_MAP for regular traffic and bounced traffic. It has no impact on business because we have no traffic being mapped to TC2 or TC6.

How I did it
Update TC_TO_QUEUE_MAP|AZURE , and test cases as well.

How to verify it
Verified by running test case test_j2files.py

/sonic/src/sonic-config-engine$ python3 setup.py test -s tests/test_j2files.py
running test
......
----------------------------------------------------------------------
Ran 29 tests in 25.390s

OK
2022-09-08 16:34:31 +00:00
Kebo Liu
67d9acda39 [SN2201] remove extra empty lines in the pg_profile_lookup.ini (#11923)
- Why I did it
Remove extra empty lines in the SN2201 pg_profile_lookup.ini to make it aligned with other platforms.
This extra empty line could confuse some test cases which need to parse this file.

Signed-off-by: Kebo Liu <kebol@nvidia.com>
2022-09-08 15:48:45 +00:00
Jiahua Wang
fa21a82d22
Add sai_mdio_access_clause22=1 in td3x2-a720dt-48s-flex.config.bcm (#11899)
Back port #11303 to 202205 branch manually
2022-09-01 09:21:59 +08:00
Dev Ojha
648ddee39c [Arista7050cx3] TD3 SKU changes for pg headroom value after interop testing with cisco 8102 (#11901)
Why I did it
After PFC interop testing between 8102 and 7050cx3, data packet losses were observed on the Rx ports of the 7050cx3 (inflow from 8102) during testing. This was primarily due to the slower response times to react to PFC pause packets for the 8102, when receiving such frames from neighboring devices. To solve for the packet drops, the 7050cx3 pg headroom size has to be increased to 160kB.

How I did it
Modified the xoff threshold value to 160kB in the pg_profile file to allow for the buffer manager to read that value when building the image, and configuring the device

How to verify it
run "mmuconfig -l" once image is built


Signed-off-by: dojha <devojha@microsoft.com>
2022-09-01 00:13:15 +00:00
saksarav-nokia
5f385de2b7 [Nokia][Nokia-IXR7250E-36x100G & Nokia-IXR7250E-36x400G] Update BCM (#11577)
config to support ERSPAN egress mirror and also set flag to preserve ECN
2022-09-01 00:05:12 +00:00
Samuel Angebault
31b208ecfc [Arista] Fix content of platform.json for DCS-720DT-48S (#11855)
Why I did it
Content of platform.json was outdated and some platform_tests/api of sonic-mgmt were failing.

How I did it
Added the necessary values to platform.json

How to verify it
Running platform_tests/api of sonic-mgmt should yield 100% passrate.
2022-09-01 00:01:45 +00:00
andywongarista
1e91ad314b Enable AN for Ethernet24-47 (#11839)
Enable port AN ON explicitly and then port will become (oper status) UP. Somehow those ports AN are not default ON in bcm sdk.
2022-08-31 23:57:31 +00:00
Junhua Zhai
2ff3b84ae8 Correct port index in Arista-720DT-48S/phy24_config.json (#11699)
Port index 22 is associated with phy23_config.json, then same port index 22 in phy24_config.json may cause gearbox port creation error. Port Ethernet22 maps to index 23.
2022-08-31 23:57:25 +00:00
andywongarista
1885e565eb
[Arista] Add missing configs for 720DT-48S (#11898)
Backport of #11362
2022-08-31 18:44:40 +08:00
andywongarista
0adfd724e6
[202205][Arista] Add initial support for 720DT-48S (#10656) (#11860)
Added initial set of config files to allow for booting and partial traffic testing in SONiC on the 720DT-48S.

How to verify it
- Switch boots
- show interfaces status shows links up on interfaces Ethernet24-51
- Traffic flows with no errors on interfaces Ethernet24-51
2022-08-30 12:39:26 +08:00
vmittal-msft
2eb6c3d03c PFCWD fix for multi port multi priority scenario for HWSKU Dell Z9332 (#11640)
PFCWD fix for multi port multi priority scenario for HWSKU Dell Z9332
2022-08-26 20:52:56 +00:00
Vivek
5654524a3e [Mellanox] [4700] Update platform capability file to support new breakout mode (#11614)
- Why I did it
This new breakout mode is required when a QSFP cable is used on the QSFP-DD supported 4700 port. since QSFP only uses the first 4 lanes, this mode is required to restrict the child ports to only use the first four lanes

- How I did it
Updated the platfrom.json file with the extended data

- How to verify it
Tested on one port:

root@msn-4700:/home/admin# show int status
  Interface                            Lanes    Speed    MTU    FEC    Alias    Vlan    Oper    Admin                                             Type    Asym PFC
-----------  -------------------------------  -------  -----  -----  -------  ------  ------  -------  -----------------------------------------------  ----------
  Ethernet0                                0      25G   9100    N/A    etp1a  routed      up       up                                  QSFP28 or later         N/A
  Ethernet1                                1      25G   9100    N/A    etp1b  routed    down       up                                              N/A         N/A
  Ethernet2                                2      25G   9100    N/A    etp1c  routed    down       up                                              N/A         N/A
  Ethernet3                                3      25G   9100    N/A    etp1d  routed    down       up                                              N/A         N/A

Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>
2022-08-26 20:52:24 +00:00
saksarav-nokia
a5171349a7
[NOKIA][DEVICE]Updated BCM config file to disable the cmic dma abort during cold boot and recycle port setting (#11825)
Signed-off-by: Sakthivadivu Saravanaraj <sakthivadivu.saravanaraj@nokia.com>
2022-08-24 15:53:50 -07:00
Sambath Kumar Balasubramanian
1d627f73c8
[Chassis][Voq] Update bcm config file system_ref_core_clock_khz param for j2cplus linecards. (#11760)
Update the bcm config file system_ref_core_clock_khz param to
handlesystems with J2cplus linecards.
We need system_ref_core_clock_khz to be set to 1600000 for supporting j2
and j2cplus linecards on the same chassis.
2022-08-19 16:15:12 -07:00
DavidZagury
25e48f9a12 [Mellanox] Add support for Service Port in SN5600 (#11609)
- Why I did it
SN5600 has an additional service interface with a different parameters than other interfaces.

- How I did it
Added the etp65 interface with the correct parameters.

- How to verify it
Run platform test on SN5600 platform.
Check the service port can startup correctly.
2022-08-17 17:08:14 +00:00
Vivek
adccd64bb4 [Mellanox] [SKU] Mellanox-SN4700-C128 SKU added (#11574)
- Why I did it
New SKU for MSN-4700 Platform i.e. Mellanox-SN4700-C128

Requirements:
* Breakout: Port 1-32: 4x100G
* Downlinks: 120 (1-30)
* Uplinks: 8 (31-32)
* Shared Headroom: Enabled
* Over Subscribe Ratio: 1:8
* Default Topology: T2
* Default Cable Length for T2: 1500m
* QoS params: The default ones defined in qos_config.j2 will be applied
* Small Packet Percentage: Used 50% for traditional buffer model Note: For dynamic model, the value defined in LOSSLESS_TRAFFIC_PATTERN|AZURE|small_packet_percentage is used

Additional Details:
Switch Type has to be programmed as SpineRouter through config_db.json in DEVICE_METADATA|localhost|type field for the buffer values & cable lengths defined in the buffers_defaults_t2.j2 to apply on the device
Cable Lengths Used for generating buffer_defaults_{t0,t1,t2}.j2 values

Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>
2022-08-11 16:17:39 +00:00
Stephen Sun
8a12a4ba02 Support queue 7 in dual ToR scenario (#11571)
Signed-off-by: Stephen Sun <stephens@nvidia.com>
2022-08-08 20:45:17 +00:00
bingwang-ms
fda1290926 Support different DSCP_TO_TC_MAP for T1 in dualtor deployment (#11569)
* Support different DSCP_TO_TC_MAP for T1 in dualtor deployment
2022-08-08 20:44:32 +00:00
kenneth-arista
2280f3854c [Arista] Enable larger number of LAGs on 7800 LCs (#11070)
For 7800 LCs, set LAG mode to support 1024 number of 16-member system
LAGs.

Why I did it
The SOC property changes are necessary to match #10519 which increases the number of system LAG IDs to 1024.

Description for the changelog
For 7800 LCs, set LAG mode to support 1024 number of 16-member system
LAGs.
2022-08-08 20:40:54 +00:00
Samuel Angebault
cf282747e6 [Arista] Update configurations for 7800R3A-36D2 (#10987)
Why I did it
This linecard runs in multi-asic mode and therefore needs the use_pcie_id_chassis file to work properly.
The default_sku file was also missing which would break the boot when no minigraph is provided.

Description for the changelog
Add missing default_sku and use_pci_id_chassis configs for 7800R3A-36D2
2022-08-08 20:39:57 +00:00
Ikki Zhu
400b401f4b [hlx/sfp] fix hlx platform sfp+ tx disable issue (#11532)
Why I did it:
To fix hlx platform sfp+ module tx disable issue

How I did it:
Fix sfp+ tx disable function according SFF-8472 specification

Co-authored-by: Eric Zhu <erzhu@celestica.com>
2022-07-28 20:37:55 +00:00
Marty Y. Lok
948c932cee [Nokia][IXR7250E] Add Nokia platform Nokia-IXR7250E-36x100GE 100G line card device dat (#11382)
Signed-off-by: mlok <marty.lok@nokia.com>
2022-07-28 20:34:05 +00:00
Stephen Sun
b4d8ee3fec [Mellanox] Support Mellanox-SN4600C-C64 as T1 switch in dual-ToR scenario (#11261)
- Why I did it
Support Mellanox-SN4600C-C64 as T1 switch in dual-ToR scenario
This is to port #11032 and #11299 from 202012 to master.

Support additional queue and PG in buffer templates, including both traditional and dynamic model
Support mapping DSCP 2/6 to lossless traffic in the QoS template.
Add macros to generate additional lossless PG in the dynamic model
Adjust the order in which the generic/dedicated (with additional lossless queues) macros are checked and called to generate buffer tables in common template buffers_config.j2
Buffer tables are rendered via using macros.
Both generic and dedicated macros are defined on our platform. Currently, the generic one is called as long as it is defined, which causes the generic one always being called on our platform. To avoid it, the dedicated macrio is checked and called first and then the generic ones.
Support MAP_PFC_PRIORITY_TO_PRIORITY_GROUP on ports with additional lossless queues.
On Mellanox-SN4600C-C64, buffer configuration for t1 is calculated as:

40 * 100G downlink ports with 4 lossless PGs/queues, 1 lossy PG, and 3 lossy queues
16 * 100G uplink ports with 2 lossless PGs/queues, 1 lossy PG, and 5 lossy queues

Signed-off-by: Stephen Sun <stephens@nvidia.com>
2022-07-28 20:30:00 +00:00
Kebo Liu
67e46e1004 add flag skip_xcvrd_cmis_mgr to skip cmis task on Nvidia platform (#11120)
Signed-off-by: Kebo Liu <kebol@nvidia.com>
2022-07-28 20:26:25 +00:00
Kebo Liu
2f59460fc4 [Mellanox] Enhance Platform API to support SN2201 - RJ45 ports and new components mgmt. (#10377)
* Support new platform SN2201 and RJ45 port

Signed-off-by: Kebo Liu <kebol@nvidia.com>

* remove unused import and redundant function

Signed-off-by: Kebo Liu <kebol@nvidia.com>

* fix error introduced by rebase

Signed-off-by: Kebo Liu <kebol@nvidia.com>

* Revert the special handling of RJ45 ports (#56)

* Revert the special handling of RJ45 ports

sfp.py
sfp_event.py
chassis.py

Signed-off-by: Stephen Sun <stephens@nvidia.com>

* Remove deadcode

Signed-off-by: Stephen Sun <stephens@nvidia.com>

* Support CPLD update for SN2201

A new class is introduced, deriving from ComponentCPLD and overloading _install_firmware
Change _install_firmware from private (starting with __) to protected, making it overloadable

Signed-off-by: Stephen Sun <stephens@nvidia.com>

* Initialize component BIOS/CPLD

Signed-off-by: Stephen Sun <stephens@nvidia.com>

* Remove swb_amb which doesn't on DVT board any more

Signed-off-by: Stephen Sun <stephens@nvidia.com>

* Remove the unexisted sensor - switch board ambient - from platform.json

Signed-off-by: Stephen Sun <stephens@nvidia.com>

* Do not report error on receiving unknown status on RJ45 ports

Translate it to disconnect for RJ45 ports
Report error for xSFP ports

Signed-off-by: Stephen Sun <stephens@nvidia.com>

* Add reinit for RJ45 to avoid exception

Signed-off-by: Stephen Sun <stephens@nvidia.com>

Co-authored-by: Stephen Sun <5379172+stephenxs@users.noreply.github.com>
Co-authored-by: Stephen Sun <stephens@nvidia.com>
2022-07-28 20:24:49 +00:00
Neetha John
f92e3e8262 Update 7260 MMU and ECN settings (#11449)
Signed-off-by: Neetha John <nejo@microsoft.com>

Why I did it
Improve throughput and latency for 7260 deployments

How I did it
Update the dynamic threshold to 0 and ECN settings as 2mb/10mb/5%

How to verify it
Updated unit tests to use the modified values for 7260 ecn settings.
2022-07-22 22:14:41 +00:00
Lawrence Lee
669687385b [device]: Add SAI checksum verify to TD3 config (#8857)
* [device]: Add SAI checksum verify to TD3 config
* A new config option was added to control the value of IPV4_INCR_CHECKSUM_ORIGINAL_VALUE_VERIFY in the EGR_FLEX_CONFIG control register (this prevents checksums of 0xffff from being propagated to other devices)
2022-07-17 03:11:54 +00:00
Ying Xie
cd991bb8e1 [Buffer] Separate buffer profile for Arista-7060CX-32S-Q24C8
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
2022-07-12 15:05:19 -07:00
Ying Xie
43b2f15286 [7060] fix default port map
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
2022-07-12 15:05:19 -07:00
zzhiyuan
a0265de430 [Arista] [201811] Add Arista-7260CX3-D96C16 HWSKU (#10034)
Why I did it
This was an ask by Microsoft to provide:
7260 config.bcm file for hardware sku Arista-7260CX3-D92C16 (Named Arista-7260CX3-D96C16).

There are 16 100G uplinks:
Ethernet13-20/1
Ethernet45-52/1

All other ports are breakout to 2 50G ports.

How I did it
Copied existing Arista-7260CX3-D108C8 HWSKU and altered the bcm.config and port_config.ini files.

How to verify it
The new 100G ports do come up with a 201811 image using this HWSKU.

Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
2022-07-12 15:05:19 -07:00
Kevin Wang
7566032403 [Buffer] Separate buffer profile for Arista-7260CX3-Q64
Signed-off-by: Kevin Wang <shengkaiwang@microsoft.com>
2022-07-12 15:05:19 -07:00
Kevin Wang
a62af01e9e [Buffer] Separate buffer profile for Arista-7260CX3-D108C8
Signed-off-by: Kevin Wang <shengkaiwang@microsoft.com>
2022-07-12 15:05:19 -07:00
Kevin Wang
8b9f1fb65d [Buffer] Separate buffer profile for Arista-7260CX3-C64
50G data is not accurate, needs further update.

Signed-off-by: Kevin Wang <shengkaiwang@microsoft.com>
2022-07-12 15:05:19 -07:00
Kevin Wang
b929929f0c [Buffer] Separate buffer profile for Arista-7060CX-32S-C32
Signed-off-by: Kevin Wang <shengkaiwang@microsoft.com>
2022-07-12 15:05:19 -07:00
Kevin Wang
a0c38a9c81 [Buffer] Separate buffer profile for Arista-7060CX-32S-D48C8
Signed-off-by: Kevin Wang <shengkaiwang@microsoft.com>
2022-07-12 15:05:19 -07:00
Kevin Wang
634b4ee1f2 [Buffer] Separate buffer profile for Arista-7060CX-32S-Q32
Signed-off-by: Kevin Wang <shengkaiwang@microsoft.com>
2022-07-12 15:05:19 -07:00
Kevin Wang
b245ee7860 [Buffer] Separate buffer profile for Celestica-DX010-D48C8
Signed-off-by: Kevin Wang <shengkaiwang@microsoft.com>
2022-07-12 15:05:19 -07:00
Kevin Wang
0c94b72c2a [Buffer] Separate buffer profile for Force10-S6100
Signed-off-by: Kevin Wang <shengkaiwang@microsoft.com>
2022-07-12 15:05:19 -07:00
Ying Xie
9494b724e3 [buffer] create infrastructure to enable buffer/QoS profiles
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
2022-07-12 15:05:19 -07:00
vmittal-msft
8035e3d9a7 Updated Chassis MMU settings for 40G/100G/400G line cards (#11108)
* Updated Chassis MMU settings for 40G/100G/400G line cards
2022-07-05 16:10:50 +00:00
arista-nwolfe
b3672c1f57
Setting the soc property for num_sa_per_sc on macsec encrypt/decrypt (cherry-pick of PR 11166) (#11279) 2022-07-05 09:06:24 -07:00
bingwang-ms
d9cd1a1355 Add extra lossy PG profile for ports between T1 and T2 (#11157)
Signed-off-by: bingwang <wang.bing@microsoft.com>

Why I did it
This PR brings two changes

Add lossy PG profile for PG2 and PG6 on T1 for ports between T1 and T2.
After PR Update qos config to clear queues for bounced back traffic #10176 , the DSCP_TO_TC_MAP and TC_TO_PG_MAP is updated when remapping is enable

DSCP_TO_TC_MAP
Before	After	Why do this change
"2" : "1"	"2" : "2"	Only change for leaf router to map DSCP 2 to TC 2 as TC 2 will be used for lossless TC
"6" : "1"	"6" : "6"	Only change for leaf router to map DSCP 6 to TC 6 as TC 6 will be used for lossless TC

TC_TO_PRIORITY_GROUP_MAP
Before	After	Why do this change
"2" : "0"	"2" : "2"	Only change for leaf router to map TC 2 to PG 2 as PG 2 will be used for lossless PG
"6" : "0"	"6" : "6"	Only change for leaf router to map TC 6 to PG 6 as PG 6 will be used for lossless PG

So, we have two new lossy PGs (2 and 6) for the T2 facing ports on T1, and two new lossless PGs (2 and 6) for the T0 facing port on T1.
However, there is no lossy PG profile for the T2 facing ports on T1. The lossless PGs for ports between T1 and T0 have been handled by buffermgrd .Therefore, We need to add lossy PG profiles for T2 facing ports on T1.

We don't have this issue on T0 because PG 2 and PG 6 are lossless PGs, and there is no lossy traffic mapped to PG 2 and PG 6

Map port level TC7 to PG0
Before the PCBB change, DSCP48 -> TC 6 -> PG 0.
After the PCBB change, DSCP48 -> TC 7 -> PG 7
Actually, we can map TC7 to PG0 to save a lossy PG.

How I did it
Update the qos and buffer template.

How to verify it
Verified by UT.
2022-06-30 05:15:41 +00:00
vmittal-msft
7c5567553f Updated buffer profile settings for TD3 based HWSKUs (Arista-7050CX3-32S-C32, Arista-7050CX3-32S-D48C8) (#11202)
* Updated buffer profile settings for TD3 based HWSKUs (Arista-7050CX3-32S-C32, Arista-7050CX3-32S-D48C8)
2022-06-24 05:15:14 +00:00
Neetha John
3304fcd3a5 [qos]: Adjust 7260 buffer sizes to accomodate extra lossless queues (#11018)
Why I did it
As part of PCBB changes, we need to enable 2 extra lossless queues. The changes in this PR are done to adjust only the reserved sizes on Th2 for the additional 2 lossless queues
Calculations are done based on 40 downlinks for T1 and 16 uplinks for dual ToR

How to verify it
Verified that the rendering works fine on Th2 dut
Unit tests have been updated to reflect the modified buffer sizes when pcbb is enabled. There are existing testcases that will test the original buffer sizes when pcbb is disabled. With these changes, was able to build sonic-config-engine wheel successfully

Signed-off-by: Neetha John <nejo@microsoft.com>
2022-06-23 02:33:48 +00:00
saksarav-nokia
5a3c8d693f Updated Nokia device BCM and platform config (#11106) 2022-06-22 23:08:51 +00:00
bingwang-ms
6f713419ba Add two extra lossless queues for bounced back traffic (#10496)
Signed-off-by: bingwang <bingwang@microsoft.com>

Why I did it
This PR is to add two extra lossless queues for bounced back traffic.
HLD sonic-net/SONiC#950

SKUs include
Arista-7050CX3-32S-C32
Arista-7050CX3-32S-D48C8
Arista-7260CX3-D108C8
Arista-7260CX3-C64
Arista-7260CX3-Q64

How I did it
Update the buffers.json.j2 template and buffers_config.j2 template to generate new BUFFER_QUEUE table.

For T1 devices, queue 2 and queue 6 are set as lossless queues on T0 facing ports.
For T0 devices, queue 2 and queue 6 are set as lossless queues on T1 facing ports.
Queue 7 is added as a new lossy queue as DSCP 48 is mapped to TC 7, and then mapped into Queue 7

How to verify it
Verified by UT
Verified by coping the new template and generate buffer config with sonic-cfggen
2022-06-22 23:05:14 +00:00
zitingguo-ms
ae90bfae4b [AN/LT][Fix bug]:enable phy_an_lt_msft attribute on some platforms (#11147) 2022-06-16 02:13:22 +00:00
Jon Goldberg
3f12919dee [Nokia ixs7215] change var/log size to 4GB (#11122)
This makes use of #11121 to add support for configuration of VAR_LOG_SIZE on Nokia IXS7215
2022-06-16 02:12:59 +00:00
Richard.Yu
3467f434e8 [Tunnel PFC][Fix bug] Fix bug and Tests for adding property 'sai_remap_prio_on_tnl_egress' (#11027)
* [Tunnel PFC] Tests for adding property 'sai_remap_prio_on_tnl_egress'

Add tests for adding property 'sai_remap_prio_on_tnl_egress', this
property should only be added in dual tor environment.

Test done:
Run test test_j2files.py

Co-authored-by: richardyu <richardyu@contoso.com>
2022-06-14 14:59:14 +00:00
Kebo Liu
7af4efacb7 [Mellanox] Update SN2201 sai profile and platform reboot script (#10978)
- Why I did it
1. SN2201 sai profile needs to be updated according to the latest hardware.
2. In the reboot script, need to use the common symbol link of the power_cycle sysfs instead of directly accessing it due to SN2201 sysfs is different than other platforms.
3. echo 1 > $SYSFS_PWR_CYCLE will trigger the reboot immediately, the following sleep 3 and echo 0 > $SYSFS_PWR_CYCLE will never be executed, can be removed.

- How I did it
1. Replace the SN2201 sai profile with the latest one.
2. In the platform_reboot script, replace the direct sysfs path with the symbol link path.
3. Remove the redundant code from platform_reboot

- How to verify it
Perform reboot on all the Nvidia platforms, and check all can be rebooted successfully.

Signed-off-by: Kebo Liu <kebol@nvidia.com>
2022-06-09 16:50:19 +00:00
Richard.Yu
af855033ec [Tunnel PFC] Add property for tunnel PFC (#10962)
* [Tunnel PFC] Add property for tunnel PFC

Replace the config.bcm file with j2 template file
- Add 'sai_remap_prio_on_tnl_egress=1' property when device metadata local
- Host subtype is 'dualtor'
- Change sai.profile foe the new config.bcm.j2
2022-06-05 15:21:24 +00:00
bingwang-ms
76502c821e Update qos template to support SYSTEM_DEFAULT table (#10936)
* Update qos template to support SYSTEM_DEFAULT table

Signed-off-by: bingwang <wang.bing@microsoft.com>
2022-06-05 15:21:10 +00:00
Samuel Angebault
912923f47b
[Arista] Update supervisor configurations (#10913)
* Removed unused default_config.json

* Remove asic.conf file from HW SKUs directories as they are not used by upstream code

* Enable dynamic PCI ID identification on Otterlake2

Co-authored-by: Maxime Lorrillere <mlorrillere@arista.com>
2022-05-30 13:34:55 -07:00
Taylor Cai
11f0bffe13
[device/celestica]:Fix failed test case of Haliburton snmp (#10844) 2022-05-26 00:06:50 +08:00
abdosi
0285bfe42e
[chassis] Fix issues regarding database service failure handling and mid-plane connectivity for namespace. (#10500)
What/Why I did:

Issue1: By setting up of ipvlan interface in interface-config.sh we are not tolerant to failures. Reason being interface-config.service is one-shot and do not have restart capability. 

Scenario: For example if let's say database service goes in fail state  then interface-services also gets failed because of dependency check but later database service gets restart but interface service will remain in stuck state and the ipvlan interface nevers get created.

Solution: Moved all the logic in database service from interface-config service which looks more align logically also since the namespace is created here and all the network setting (sysctl) are happening here.With this if database starts we recreate the interface.

Issue 2: Use of IPVLAN vs MACVLAN

Currently we are using ipvlan mode.  However above failure scenario is not handle correctly by ipvlan mode. Once the ipvlan interface is created and ip address assign to it and if we restart interface-config or database (new PR) service Linux Kernel gives error "Error: Address already assigned to an ipvlan device."  based on this:https://github.com/torvalds/linux/blob/master/drivers/net/ipvlan/ipvlan_main.c#L978Reason being if we do not do cleanup of ip address assignment (need to be unique for IPVLAN)  it remains in Kernel Database and never goes to free pool even though namespace is deleted. 

Solution: Considering this hard dependency of unique ip macvlan mode is better for us and since everything is managed by Linux Kernel and no dependency for on user configured IP address.

Issue3: Namespace database Service do not check reachability to Supervisor Redis Chassis   Server.

Currently there is no explicit check as we never do Redis PING from namespace to Supervisor Redis Chassis  Server. With this check it's possible we will start database and all other docker even though there is no connectivity and will hit the error/failure late in cycle

Solution: Added explicit PING from namespace that will check this reachability.

Issue 4:flushdb give exception when trying to accces Chassis Server DB over Unix Sokcet.

Solution: Handle gracefully via try..except and log the message.
2022-05-24 16:54:12 -07:00
jerseyang
c92bfe0728
Add belgite support (#9511)
Why I did it
add celestica belgite platform

How I did it
add belgite platform in celestica

Co-authored-by: nicwu-cel <nicwu@celestica.com>
Co-authored-by: anjian <anjian@celestica.com>
Co-authored-by: sandycelestica <sandyli@celestica.com>
2022-05-23 18:45:37 -07:00
Song Yuan
b23ad6748a
[Arista] Add QOS and buffer profiles for SKU Arista-7800R3-48CQM2-C48 (#10752)
* Add QOS and buffer profiles for Arista SKU.

* Add unit test for SKU Arista-7800R3-48CQM2-C48.
2022-05-23 13:50:04 -07:00
Maxime Lorrillere
392899682f
[Arista] Add support for Wolverine linecards (#8887)
Add support for WolverineQCpu, WolverineQCpuMs, WolverineQCpuBk, WolverineQCpuBkMs

Co-authored-by: Maxime Lorrillere <mlorrillere@arista.com>
2022-05-20 14:11:06 -07:00
Marty Y. Lok
937bf09c92
{nokia] Update Nokia IXR7250e supervisor card device data (#10595)
Signed-off-by: mlok <marty.lok@nokia.com>
2022-05-19 11:38:34 -07:00
Vivek R
5ea244cac8
Removed platform specific reboot files for mellanox simx platforms (#10806)
- Why I did it
Platform_reboot files for simx doesn't do aything different apart from calling /sbin/reboot. which is anyway done in the /usr/local/bin/reboot script i.e. the parent script which calls the platform specific reboot scripts if present.

Moreover, /sbin/reboot invoked in the platform specific reboot script is a non-blocking call and thus it returns back to the original script (although /sbin/reboot does it job in the background) and we see messages like this.

Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>
2022-05-14 15:20:57 +03:00
Arun Saravanan Balachandran
942bef4475
DellEMC: S6100, Z9332f - Include ONIE version in 'show platform firmware status' (#10493)
Why I did it
To include ONIE version in show platform firmware status command output in DellEMC S6100 and Z9332f platforms.

How I did it
Include ‘ONIE’ in the list of components provided by platform APIs in DellEMC S6100 and Z9332f.
Unmount ONIE-BOOT if mounted using fast/soft/warm-reboot plugins in DellEMC S6100.
2022-05-12 09:24:06 -07:00
Samuel Angebault
123f20fea3
[Arista] Add missing configuration files for linecards (#10749)
Why I did it
Fixes some pmon errors/warnings by providing missing configuration files

How I did it
Add missing pcie.yaml and sensors.conf for supported linecards

How to verify it
pcie-check should pass
sensors should display proper sensor names
2022-05-09 11:51:38 -07:00
jostar-yang
b86499ccb9
[PDDF] Rename temp for as7816/7326/7726 (#10609)
* [PDDF] Rename temp for 7816/7326/7726

Signed-off-by: Jostar Yang <jostar_yang@accton.com.tw>

* Change naming to pddf device

Co-authored-by: Jostar Yang <jostar_yang@accton.com.tw>
2022-05-09 10:47:45 -07:00
Polly Hsu
a1e76d25b7
[as7816-64x] Update installer.conf (#10418)
Co-authored-by: ecsonic <ecsonic@edge-core.com>
Why I did it
The customer report of the PCIe Bus Errors upon the SDK initialization of as7816-64x.

How I did it
Based on the internal info and discussion, update "pcie_aspm=off" into ONIE_PLATFORM_EXTRA_CMDLINE_LINUX of installer.conf to resolve it.
2022-05-02 11:09:16 -07:00
Song Yuan
a9d5858da1
Fix buffer template for Arista SKU. (#10663)
Why I did it
The buffer pool & profile setting in buffer template was not correct and caused the errors like the following:

ERR swss#orchagent: :- parseReference: malformed reference:[BUFFER_PROFILE|ingress_lossless_profile]. Must not be surrounded by [ ]

How I did it
Fix the buffer pool & profile setting by removing "[]".

How to verify it
Loaded image with this fix in a switch and made sure the error was not seen anymore.
2022-05-02 09:49:42 -07:00
vmittal-msft
ede1e0e889
Adjustment to ingress pool size to accomodate brcm sai (#10694) 2022-04-28 20:39:56 -07:00
zzhiyuan
d19a953e13
[Arista] Add 1x100G over 4 lanes configuration for 7060DX4 (#10655)
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
2022-04-25 08:11:32 -07:00
bingwang-ms
3fc3259a35
Define qos map AZURE_TUNNEL for QoS remapping of tunnel traffic (#10565)
* Add AZURE_TUNNEL map

Signed-off-by: bingwang <wang.bing@microsoft.com>
2022-04-25 15:06:10 +08:00
Taylor Cai
988a687182
Fix issue test_crm and test_fib (#10585)
Why I did it
Fix issue (https://github.com/Azure/sonic-buildimage/issues/9171) and (https://github.com/Azure/sonic-buildimage/issues/9236)

How I did it
Add flag in config file for get correct count of IPv6 entry.
Add init config file to set IPv4 ECMP hash on L4.

How to verify it
Compile the sonic_platform wheel for e1031, then upload to device and install the wheel, verify using testbed.
2022-04-22 20:35:52 +08:00
vmittal-msft
dd243c1024
Changes to support topology and port speed agnostic switch init for TD3 based platforms (#10587) 2022-04-18 15:19:22 -07:00
Junhua Zhai
04f810a346
[gearbox] use credo sai v0.7.5 (#10578)
The v0.7.5 has bug fix for the support of gearbox port and macsec counters. It also includes a owl firmware update with owl.lz4.fw.1.94.0.bin.

How I did it
Update credo sai url for v0.7.5
Update gearbox_config.json with using firmware owl.lz4.fw.1.94.0.bin instead of owl.lz4.fw.1.92.1.bin

How to verify it
Test gearbox port and macsec counter successfully on A7280.
2022-04-15 10:41:43 -07:00
Junchao-Mellanox
0191300b96
[Mellanox] Auto correct PSU voltage threshold (WA) (#10394)
- Why I did it
There is a hardware bug that PSU voltage threshold sysfs returns incorrect value. The workaround is to call "sensor -s" to refresh it.

- How I did it
Call "sensor -s" when the threshold value is not incorrect and PSU is "DELTA 1100"

- How to verify it
Unit test and Manual test
2022-04-14 08:14:40 +03:00
Oleksandr Kozodoi
8c10c01bd8
Updated format of generating BUFFER_QUEUE in buffers_defaults templates (#9850)
This PR includes necessary changes for correct generating BUFFER_QUEUE values in DB. Changes are based on the schema.md

Why I did it
Change format of generating BUFFER_QUEUE in DB according to schema.md and yang-model.

Old format:
    "BUFFER_QUEUE": {
        "Ethernet0,Ethernet100,Ethernet104,Ethernet108,Ethernet112,Ethernet116,Ethernet12,Ethernet120,Ethernet124,Ethernet16,Ethernet20,Ethernet24,Ethernet28,Ethernet32,Ethernet36,Ethernet4,Ethernet40,Ethernet44,Ethernet48,Ethernet52,Ethernet56,Ethernet60,Ethernet64,Ethernet68,Ethernet72,Ethernet76,Ethernet8,Ethernet80,Ethernet84,Ethernet88,Ethernet92,Ethernet96|queue": {
            "profile": "profile"
        },
        "Ethernet0,Ethernet100,Ethernet104,Ethernet108,Ethernet112,Ethernet116,Ethernet12,Ethernet120,Ethernet124,Ethernet16,Ethernet20,Ethernet24,Ethernet28,Ethernet32,Ethernet36,Ethernet4,Ethernet40,Ethernet44,Ethernet48,Ethernet52,Ethernet56,Ethernet60,Ethernet64,Ethernet68,Ethernet72,Ethernet76,Ethernet8,Ethernet80,Ethernet84,Ethernet88,Ethernet92,Ethernet96|queue": {
            "profile": "profile"
        }
    },
New format:
    "BUFFER_QUEUE": {
        "Ethernet0|queue": {
            "profile": "profile"
        },
        "Ethernet0|queue": {
            "profile": "profile"
        },
        "Ethernet4|queue": {
            "profile": "profile"
        },
        "Ethernet4|queue": {
            "profile": "profile"
        },
        "Ethernet8|queue": {
            "profile": "profile"
        },
        "Ethernet8|queue": {
            "profile": "profile"
        },
        ...
    }
How I did it
Updated structure of buffers_defaults jinja templates.

Signed-off-by: Oleksandr Kozodoi <oleksandrx.kozodoi@intel.com>
2022-04-13 09:11:01 -07:00
byu343
da43edcf3e
[arista] Update serdes tuning values for 7800r3_48cqm2 (#9967)
This update the serdes tuning values for Arista 7800r3_48cqm2. The values are for the optical transceivers.
2022-04-12 15:53:35 -07:00
Nikola Dancejic
f2acf952fb
[device config] Adding configuration for default route fallback (#10465)
* [device config] Adding configuration for default route fallback
* Set sai_tunnel_underlay_route_mode attribute to fallback to default route if more specific route is unavailable.
2022-04-12 14:43:03 -07:00
brandonchuang
2116f62978
[AS9716-32D] Support i2c mux reset (#10492)
Why I did it
    Prevent from i2c bus to get locked.

How I did it
    Add sysfs driver to access ioport.
    Command to reset i2c mux:
    echo 1 > /sys/devices/platform/as9716_32d_ioport/i2c_mux_rst
    Command to bring i2c mux out of reset:
    echo 0 > /sys/devices/platform/as9716_32d_ioport/i2c_mux_rst

Signed-off-by: Brandon Chuang <brandon_chuang@edge-core.com>
2022-04-09 10:51:49 -07:00
saksarav-nokia
f311947cfa
[Nokia][device] Updated the BCM config file to reduce the CPU usage (#10485)
Signed-off-by: Sakthivadivu Saravanaraj <sakthivadivu.saravanaraj@nokia.com>
2022-04-07 14:34:32 -07:00
byu343
58df23e1d7
[arista] Update serdes tuning values for 7280cr3 (#9966) 2022-04-05 09:49:26 -07:00
Vadym Yashchenko
8e616c153b
[BFN] Refactoring and adding some functions of Thermal class (set and get thresholds and etc.) (#10205)
* Revised set_high_thershold and set_low_thershold methobs in the thermal.py

Signed-off-by: Vadym Yashchenko <vadymx.yashchenko@intel.com>

* Revised set_low_thershold and set_high_thershold

Signed-off-by: Vadym Yashchenko <vadymx.yashchenko@intel.com>

* Added separated files with thermal thresholds, changed platform.json and
thermal.py

Signed-off-by: Vadym Yashchenko <vadymx.yashchenko@intel.com>

* Revised on code revieww

Signed-off-by: Vadym Yashchenko <vadymx.yashchenko@intel.com>

* Reverted thermal.py

Signed-off-by: Vadym Yashchenko <vadymx.yashchenko@intel.com>

* Revised ther python.py

Signed-off-by: Vadym Yashchenko <vadymx.yashchenko@intel.com>

* Revised due to code review

Signed-off-by: Vadym Yashchenko <vadymx.yashchenko@intel.com>

* Added fucntion for fix the problem of tofino sensor high critical threshold

Signed-off-by: Vadym Yashchenko <vadymx.yashchenko@intel.com>

* Revised due to code review

Signed-off-by: Vadym Yashchenko <vadymx.yashchenko@intel.com>

* Revised due to code review

Signed-off-by: Vadym Yashchenko <vadymx.yashchenko@intel.com>

* Revised due to code review

Signed-off-by: Vadym Yashchenko <vadymx.yashchenko@intel.com>

* Revised only for cab18-4

Signed-off-by: Vadym Yashchenko <vadymx.yashchenko@intel.com>

* Revised default thresholds

Signed-off-by: Vadym Yashchenko <vadymx.yashchenko@intel.com>

* Revised ther def thresholds

Signed-off-by: Vadym Yashchenko <vadymx.yashchenko@intel.com>

* Revised on code review

Signed-off-by: Vadym Yashchenko <vadymx.yashchenko@intel.com>

* Revised platform.json and thermal_thresholds.json

Signed-off-by: Vadym Yashchenko <vadymx.yashchenko@intel.com>

* Code review in PR to azure (trigger CI)

Signed-off-by: Vadym Yashchenko <vadymx.yashchenko@intel.com>

* Added handle of exception

Signed-off-by: Vadym Yashchenko <vadymx.yashchenko@intel.com>

* Revised exception handler

* Added psu-1 thermal names to platfrom.json

Signed-off-by: Vadym Yashchenko <vadymx.yashchenko@intel.com>

* Changed platform.json and thermal_thresholds.json in
x86_64-acton_as9516_32d-r0

Signed-off-by: Vadym Yashchenko <vadymx.yashchenko@intel.com>

* Removed indentation from json file

Signed-off-by: Vadym Yashchenko <vadymx.yashchenko@intel.com>
2022-04-05 09:13:08 -07:00
Andriy Kokhan
31be203af6
[BFN] Updated x86_64-accton_as9516_32d-r0/platform.json (#10368)
Signed-off-by: Andriy Kokhan <andriyx.kokhan@intel.com>
2022-04-05 09:11:38 -07:00
bingwang-ms
b9dd1df372
Update qos config to clear queues for bounced back traffic (#10176)
* Update qos config to clear queues for bounced back traffic

Signed-off-by: bingwang <bingwang@microsoft.com>
2022-04-05 22:32:25 +08:00
jostar-yang
b39b7a3f2d
[Accton/PDDF] Support pddf to as4630/as7816/as7326 (#10340)
Why I did it
Support pddf to as4630/as7816/as7326

How I did it
Send needed file to the PR for these platform

How to verify it
Test sensors and show platform cmd.
root@as7326-56x-3:/home/admin# show platform psustatus
PSU Model Serial HW Rev Voltage (V) Current (A) Power (W) Status LED

PSU 1 FSF045-611 FSF0451912000505 N/A 12.06 5.50 66.00 OK green
PSU 2 FSF045-611 FSF0451912000568 N/A 12.00 5.50 66.00 OK green

root@as7326-56x-3:/home/admin# sensors
lm75-i2c-15-4a
Adapter: i2c-1-mux (chan_id 6)
Main Board Temperature: +35.5 C (high = +80.0 C, hyst = +75.0 C)

lm75-i2c-15-4b
Adapter: i2c-1-mux (chan_id 6)
CPU Board Temperature: +29.0 C (high = +80.0 C, hyst = +75.0 C)

fan_ctrl-i2c-11-66
Adapter: i2c-1-mux (chan_id 2)
fan1: 9100 RPM
fan2: 9400 RPM
fan3: 9300 RPM
fan4: 9600 RPM
fan5: 9000 RPM
fan6: 9100 RPM
fan7: 9100 RPM
fan8: 9300 RPM
fan9: 9200 RPM
fan10: 9400 RPM
fan11: 9200 RPM
fan12: 9400 RPM

pch_haswell-virtual-0
Adapter: Virtual device
temp1: +43.0 C

psu_pmbus-i2c-17-59
Adapter: i2c-1-mux (chan_id 0)
in3: +12.06 V
fan1: 6272 RPM
temp1: +37.0 C
power2: 60.00 W
curr2: +6.00 A

lm75-i2c-15-49
Adapter: i2c-1-mux (chan_id 6)
Main Board Temperature: +40.0 C (high = +80.0 C, hyst = +75.0 C)

lm75-i2c-15-48
Adapter: i2c-1-mux (chan_id 6)
Main Board Temperature: +39.0 C (high = +80.0 C, hyst = +75.0 C)

psu_pmbus-i2c-13-5b
Adapter: i2c-1-mux (chan_id 4)
in3: +12.00 V
fan1: 6144 RPM
temp1: +36.0 C
power2: 66.00 W
curr2: +5.50 A

coretemp-isa-0000
Adapter: ISA adapter
Package id 0: +50.0 C (high = +82.0 C, crit = +104.0 C)
Core 0: +50.0 C (high = +82.0 C, crit = +104.0 C)
Core 1: +50.0 C (high = +82.0 C, crit = +104.0 C)
Core 2: +50.0 C (high = +82.0 C, crit = +104.0 C)
Core 3: +50.0 C (high = +82.0 C, crit = +104.0 C)

Signed-off-by: Jostar Yang <jostar_yang@accton.com.tw>
2022-04-01 09:55:04 -07:00
arunlk-dell
ddc269ac81
DellEMC: Added platform.json file for N3248TE (#9404)
Why I did it
Added platform.json file for N3248TE

How I did it
Defined the platform.json file with the required components under chassis.

How to verify it
validated the API 2.0 test suite

Co-authored-by: Arun LK <Arun_L_K@dell.com>
2022-04-01 07:35:07 -07:00
arunlk-dell
a9e86c3b82
DellEMC: N3248TE platform API2.0 changes (#10400)
DellEMC: N3248TE platform API2.0 changes

Why I did it
N3248TE Platform API 2.0 changes

How I did it
Implemented the functional API's needed for Platform API 2.0
Added system_health_monitoring_config.json file
How to verify it
Used the API 2.0 test suite to validate the test cases.

Co-authored-by: Arun LK <Arun_L_K@dell.com>
2022-04-01 07:34:31 -07:00
Marty Y. Lok
13353dffe8
[Nokia][device] Update the BCM config with Recycle ports info for Nokia IXR7250E platform (#10389)
Signed-off-by: mlok <marty.lok@nokia.com>
2022-03-31 20:54:40 -07:00
jostar-yang
7debcffe62
[Accton/PDDF] Enable thermalctld in pmon (#9982)
When do "skip_thermalcltd: true" will let "show platform fan" and "show platform temp" fail.
When enable thermalctld, these cmd will work well.

Signed-off-by: Jostar Yang <jostar_yang@accton.com.tw>
2022-03-29 13:35:42 -07:00
Dror Prital
8bc81206c5
[Mellanox] Update NVIDIA License header for files changed since 1.1.2022 (#10289)
- Why I did it
Update NVIDIA Copyright header to "mellanox" files which were changed since 1.1.2022

- How I did it
Update the copyright header

- How to verify it
Sanity tests and PR checkers.
2022-03-23 13:19:25 +02:00
dflynn-Nokia
99b7891e4d
[Nokia ixs7215] Fixes to support Debian bullseye (#10309)
The following changes are provided to support bullseye and the latest master
branch content.
    - Accommodate relocated fan and thermal sysfs entries in bullseye
    - Add support for chassis and PSU HW revision


Why I did it
Fix platform issues introduced by the bullseye kernel upgrade.

How I did it
Minor fixes to Nokia ixs7215 platform code

How to verify it
Execute the following CLI commands
show platform summary
show platform fan
show platform temperature
2022-03-22 17:58:46 -07:00
Eric Zhu
4caa887642
Fix issue of partially parsing syseeprom value (#10020) (#10276)
Why I did it
The current code assumes that the value part does not have whitespace. So everything after the whitespace will be ignored. The syseeprom values returned from platform API do not match the output of "show platform syseeprom" on dx010 and e1031 device.

How I did it
This change improved the regular expression for parsing syseeprom values to accommodate whitespaces in the value.
PR 10021 provides the solution, but committed to the wrong place for dx010 and e1031.

How to verify it
Compile the sonic_platform wheel for dx010, then upload to device and install the wheel, verify the platform eeprom API.

Signed-off-by: Eric Zhu <erzhu@celestica.com>
2022-03-21 09:25:36 -07:00
Marty Y. Lok
e919f4dafa
[Nokia][IXR7250E]Update Nokia IXR7250E platform device data file (#10091)
Signed-off-by: mlok <marty.lok@nokia.com>
2022-03-21 17:58:03 +05:30
Kebo Liu
9d2078c446
[Mellanox] Update Mellanox SN2201 device specific files (#10275)
Update device-specific files for new platform SN2201, including:

device/mellanox/x86_64-nvidia_sn2201-r0/ACS-SN2201/buffers_defaults_objects.j2
device/mellanox/x86_64-nvidia_sn2201-r0/ACS-SN2201/hwsku.json
device/mellanox/x86_64-nvidia_sn2201-r0/default_sku
device/mellanox/x86_64-nvidia_sn2201-r0/pcie.yaml
device/mellanox/x86_64-nvidia_sn2201-r0/platform.json
device/mellanox/x86_64-nvidia_sn2201-r0/platform_components.json
device/mellanox/x86_64-nvidia_sn2201-r0/sensors.conf

Signed-off-by: Kebo Liu <kebol@nvidia.com>
Co-authored-by: Stephen Sun <stephens@nvidia.com>
2022-03-18 12:11:13 -07:00
Jeff Henning
ad6200029f
Edgecore 4630/5835/7326/7816 API2.0 platform support (#10053)
* Initial pass of EdgeCore platform changes.

* Remove libevent dependency from lldpd.

* Remove python2 dependencies python3.7 force from platform install script.

* Include usbmount support changes.

* Add missing 4630 install file.

* Update a few file permissions.  Add umask line to Makefile.  Specify python3.9 in install script.

* Misc platform updates:
- Add missing fan drawer component to sonic_platform
- Remove kernel version specification from Makefile
- Update to 4630 utility

* - Fix file permissions on source files
- Fix compile issue with 4630 driver modules (set_fs, get_fs, no longer supported in kernel 5.10)

* Fix missing/extra parens in 4630 util script.

* Fix indentation in fanutil.py.

* Integrate deltas from Edgecore to ec_platform branch.

* Installer update from Edgecore to resolve smbus serial console errors.

* Update stable_size for warm boot.

* Fix SFP dictionary key to match xcvrd.

* - Add missing define in event.py files needed for xcvrd
- Fix SFP info dict key for 7xxx switches

* 5835 platform file updates including installer and 5835 utility.

* 5835 fix for DMAR errors on serial console.

* Don't skip starting thermalctld in the pmon container.

* Revert several changes that were not related to platform.

* Run thermalctld in pmon container.

* Don't disable thermalctld in the pmon container.

* Fix prints/parens in 7816 install utility.

* - Incorporate 7816 changes from Edgecore
- Fix 7326 driver file using old kernel function

* Update kernel modules to use kernel_read().

* Fix compile errors with 7816 and 7326 driver modules.

* Fix some indents preventing platform files from loading.

* Update 7816 platform sfp dictionary to match field names in xcvrd.

* Add missing service and util files for 7816.

* Update file names, etc. based on full SKU for 7816.

* Delete pddf files not needed.  These were causing conflicts with API2.0
implementation.

* Remove pddf files suggested by Edgecore that were preventing API2.0 support from starting.

* Install API2.0 file instead of pddf.

* Update 7326 mac service file to not use pddf.  Fix syntax errors in 7326 utility script.

* Fix sonic_platform setup file for 7326.

* Fix syntax errors in python scripts.

* Updates to 7326 platform files.

* Fix some tab errors pulled down from master merge.

* Remove pddf files that were added from previous merge.

* Updates for 5835.

* Fix missing command byte for 5835 psu status.

* Fix permission bits on 4630 service files.

* Update platforms to use new SFP refactoring.

* Fix unused var warnings.
2022-03-18 06:17:08 +05:30
Marty Y. Lok
5a531f4eb2
[Nokia][VoQ] The role of the Inband port should be "Inb" and recycle port (#9950)
Signed-off-by: mlok <marty.lok@nokia.com>
2022-03-15 09:21:50 -07:00
Taras Keryk
a89f294fd5
[BFN] Implementation API for platform component (#10180)
* [BFN] Implementation API for platform component
	SONiC has a concept of "platform components"
	this may include - CPLD, FPGA, BIOS, BMC, etc.

	These changes are needed to read the version of the BIOS and BMC component.

	What I did
		Create components.py module
		Add funcion for reading componet version to thrift interface
	How I did it
		The previous implementaion didn't have platform components API, so fwutil return an empty list.
		After implementation of the platform component API, we have actual list of platform components and firmware versions

	How to verify it
		Run manually 'fwutil show status' or run unit tests

	Previous command output
		Chassis                   Module    Component    Version    Description
		------------------------  --------  -----------  ---------  -------------

	New command output
		Chassis                   Module    Component    Version    Description
                ------------------------  --------  -----------  ---------  -------------
                Chassis1		  N/A       BIOS         1.2.3	   Chassis BIOS
                                                    BMC          5.1	   Chassis BMC
Signed-off-by: Taras Keryk <tarasx.keryk@intel.com>

* [BFN] Implementation API for platform component
            SONiC has a concept of "platform components"
            this may include - CPLD, FPGA, BIOS, BMC, etc.

            These changes are needed to read the version of the BIOS and BMC component.

            What I did
                    Create components.py module
                    Add funcion for reading componet version to thrift interface
            How I did it
                    The previous implementaion didn't have platform components API, so fwutil return an empty list.
                    After implementation of the platform component API, we have actual list of platform components and firmware versions

            How to verify it
                    Run manually 'fwutil show status' or run unit tests

            Previous command output
                    Chassis                   Module    Component    Version    Description
                    ------------------------  --------  -----------  ---------  -------------

            New command output
                    Chassis                   Module    Component    Version    Description
                    ------------------------  --------  -----------  ---------  -------------
                    Chassis1                  N/A       BIOS         1.2.3     Chassis BIOS
                                                        BMC          5.1       Chassis BMC

Signed-off-by: Taras Keryk <tarasx.keryk@intel.com>

* [BFN] Implementation API for platform component
    get chassis name from json

* [BFN] Implementation API for platform component
      Updated platform and platrom_components json

* [BFN] Implementation API for platform component
      Fixed spaces in component.py

* [BFN] Implementation API for platform component
      Fixed exception in component.py

* Update chassis.py

* [BFN] Implementation API for platform component
      Fixed spaces in component.py, chassis.py

* [BFN] Implementation API for platform component: Fixed spaces in component.py, chassis.py

* Fixed exception in get_bios_version
2022-03-10 16:25:06 +05:30
Kostiantyn Yarovyi
bf5f9c2918
[BFN] Update configuration files (#9913)
* [Barefoot] update switch-tna-sai.conf file

* remove deprecated conf files

* [Barefoot] update switch-tna-sai.conf file for Accton wedge100bf_32qs platform

* pdated switch-tna-sai.conf
2022-03-09 09:57:08 +05:30