Why I did it
Nvidia platform API does not support set LED to orange
How I did it
Allow user to set LED to orange
How to verify it
Added unit test
Manual test
#### Why I did it
DPB falls due to missing POLL_INTERVAL in sonic-flex_counter yang model.
#### How I did it
Added POLL_INTERVAL leaf to ACL container in sonic-flex_counter yang model.
#### How to verify it
Run the command config interface breakout <interface> <breakout_mode>
**NOTE:**
To verify this fix, a PR ([add set_owner to feature yang](https://github.com/Azure/sonic-buildimage/pull/9075)) that fix another bug in SONiC should be merged to master.
Closes#7958
#### Why I did it
The previous implementation of sonic-cfggen did a simple comparison between default breakout mode in
hwsku.json and supported modes in platform.json. To set a different default speed in hwsku.json
it was required to add one more entry to supported modes in platfrom.json file:
1x10G[100G,50G] vs 1x100G[50G,10G]
The new implementation does more intelligent parsing and analysis of supported and default modes. It
allows changing default speed without adding a new entry to platform.json.
#### How I did it
Add more intelligent parsing and analysis of supported and default modes.
#### How to verify it
Run sonic-config-engine unit tests from sonic-config-engine/tests directory
- Why I did it
Add support for SN2201 platform
- How I did it
Add required content for SN2201 platform
Note: still missing kernel driver support for this system. Once all is upstream will be updated as well.
- How to verify it
Install and basic sanity tests including traffic.
Signed-off-by: liora liora@nvidia.com
Why I did it
Adding platform support for centec v682-48y8c and v682-48x8c.
V682-48y8c switch has 48 SFP+ (1G/10G/25G) ports, 8 QSFP28 (40G/100G) ports on CENTEC TsingMa.MX.
V682-48y8c is different from V682-48y8c_d in that:
transceiver is managed by cpu smbus rather than TsingMa.MX i2c bus.
port led is managed by mcu inside TsingMa.MX.
fan, psu, sensors, leds are managed by cpu smbus other than the cpu board vendor's close sourse driver.
V682-48x8c switch has 48 SFP+ (1G/10G) ports, 8 QSFP28 (40G/100G) ports on CENTEC TsingMa.MX.
CPU used in v682-48y8c and v682-48x8c is Intel(R) Xeon(R) CPU D-1527.
How I did it
Modify related code in platform and device directory.
Upgrade centec sai to v1.9.
upgrade python to python3 and kernel version to 5.0 for V682-48y8c_d.
How to verify it
Build centec amd64 sonic image, verify platform functions (port, sfp, led etc) on centec v682-48y8c and v682-48x8c board.
Co-authored-by: shil <shil@centecnetworks.com>
- Why I did it
Fix sonic-config-engine unit test failure
- How I did it
* Do not use pytest fixture in the test since it is not compatible with unittest framework which is used by all of the rest test cases.
* Supply 2 missing files
- How to verify it
Run unit test or compile the module (when the unit test will run automatically)
Signed-off-by: Stephen Sun <stephens@nvidia.com>
This interface type is used for recirculation on chassis.
The definition is required to prevent this interface from being
considered a physical interface in sonic-platform-common and
sonic-platform-daemon
- Why I did it
To include latest fixes.
SAI
1. Reclaim buffers for port which is admin down
2. Support for Spectrum-4 os Nvidia ASIC simulation
3. Support for SN2201
4. Fix host interface table entry, one channel per trap (fix sflow double registration)
5. 2 new queue counters - ecn marked packets + shared current occupancy
6. Fix storm policer unknown unicast
7. Add key/value for accuflow counters
8. Add MAC move
9. Add mirror congestion mode attribute
SDK
1. Under various circumstances, Ethernet ports falsely showed that InfiniBand cables were connected.
2. In SN4600C, at times, the link up time in both DAC and optics cables may, in the worst case, take up to 15 seconds.
3. Using SN4600C with copper or optics loopback cables in NRZ speeds, link may raise in long link up times
4. When ECMP has high amount of next-hops based on VLAN interfaces, in some rare cases, packets will get a wrong VLAN tag and will be dropped.
5. When connecting Spectrum devices with optical transceivers that support RXLOS, remote side port down might cause the switch firmware to get stuck and cause unexpected switch behavior.
6. Aggregation event is missing for WJH L2 drop reason 'Unicast egress port list is empty'.
7. Tying the SCL and SDA of the optical modules to 3.3V causes errors.
8. On SN4600, there was a delay of more than 10 seconds from the time a data packet is sent from CPU until it is transmitted through one of the switch ports.
9. While using SN4600C system with Finisar FTLC1157RGPL 100GbE CWDM4 modules, intermittent link flaps across multiple ports may be observed.
10. In Spectrum-2 and Spectrum-3 systems, link did not work in auto-negotiation when connected to Marvell PHY. KR mechanism has been enhanced to integrate with Marvell PHY.
11. The tunnel counter counts the drop packets now for Spectrum-2 and Spectrum-3 and consistent with Spectrum behavior and count the ECN dropped packets as well.
12. When connecting SN3800 to Cisco-9000, fast-linkup flow will fail and will rise in the normal flow.
13. Race condition in WJH library: when multiple threads load the LAG shared memory concurrently, the program may crash.
14. Add WJH L2 drop reason 'Unicast egress port list is empty' as a new drop reason.
15. Fixed a memory leak in sx_api_port_sflow_statistics_get API.
16. During initialization flow, the command interface that is used by the minimal driver and SDK caused the collision in the firmware since the same buffer is used in the firmware for the two interfaces.
17. Fix route issue on Kernel 5.10
- How I did it
Updated SDK/SAI submodule and relevant makefiles with the required versions.
- How to verify it
Build an image and run tests from "sonic-mgmt".
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
<!--
Please make sure you've read and understood our contributing guidelines:
https://github.com/Azure/SONiC/blob/gh-pages/CONTRIBUTING.md
** Make sure all your commits include a signature generated with `git commit -s` **
If this is a bug fix, make sure your description includes "fixes #xxxx", or
"closes #xxxx" or "resolves #xxxx"
Please provide the following information:
-->
#### Why I did it
1. Fix auditd log file path, because known issue: https://github.com/Azure/sonic-buildimage/issues/9548
2. When SONiC change to based on bullseye, auditd version upgrade from 2.8.4 to 3.0.2, and in auditd 3.0.2 the plugin file path changed to /etc/audit/plugins.d, however the upstream auditisp-tacplus project not follow-up this change, it still install plugin config file to /etc/audit/audisp.d. so the plugin can't be launch correctly, the code change in src/tacacs/audisp/patches/0001-Porting-to-sonic.patch fix this issue.
#### How I did it
Fix tacacs plugin config file path.
Create /var/log/audit folder for auditd.
#### How to verify it
Pass all UT, also run per-command acccounting UT to validate plugin loaded.
#### Which release branch to backport (provide reason below if selected)
<!--
- Note we only backport fixes to a release branch, *not* features!
- Please also provide a reason for the backporting below.
- e.g.
- [x] 202006
-->
- [ ] 201811
- [ ] 201911
- [ ] 202006
- [ ] 202012
- [ ] 202106
#### Description for the changelog
<!--
Write a short (one line) summary that describes the changes in this
pull request for inclusion in the changelog:
-->
Fix tacacs plugin config file path.
Create /var/log/audit folder for auditd.
#### A picture of a cute animal (not mandatory but encouraged)
What I did:
Updated Jinja Template to enable BGP Graceful Restart based on device role. By default it will be enable only if the device role type is TorRouter.
Why I did:-
By default FRR is configured in Graceful Helper mode. Graceful Restart is needed on T0/TorRouter only since the device can go for warm-reboot. For T1/LeafRouter it need to be in Helper mode only
- Why I did it
To have an ability to use PRM sniffer.
- How I did it
Enabled the option in configure flags.
- How to verify it
Built and ran on switch. Enabled the feature in runtime and checked the sniffer recording.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
Why I did it
database.sh failed to create the database for namespace in multiasic platform.
The latest code Docker version 20.10.x, command "docker create" no longer takes optional "NET=" with empty value. Syntax error show with current docker create command in database.sh. Issue #9503
How I did it
Modify the docker_image_ctl.j2 to set default network setting NET="bridge" instead of empty for namespace database.
#### Why I did it
POLL_INTERVAL cannot be set if any of the detection/restoration times in this table is less than the POLL_INTERVAL.
#### How I did it
Add "must" constraint to make sure detection/restoration times are greater than POLL_INTERVAL.
#### How to verify it
Use apply-patch command to update POLL_INTERVAL.
Build sonic-yang-model.
- Why I did it
The capability files were incorrect in comparison to the marketing spec of the SN4410 platform.
- How I did it
Aligned the capability files according to the marketing spec.
- How to verify it
Basic manual sanity checks:
1. Check if critical docker containers were UP
2. Check if interfaces were created and were UP
3. Check if interfaces created in the syncd docker container by executing – sx_api_ports_dump.py script
4. Check the logs from the start of the switch – everything was OK
5. Verified the port breakout
Signed-off-by: Vadym Hlushko <vadymh@nvidia.com>
- Why I did it
To fix an issue that hw-mgmt patches were not applied. One patch was already in upstream hw-mgmt package thus applying it again caused an error and no other patches were applied. Also, I did it to improve the Makefile, so that the make will fail in case patches fail to apply.
- How I did it
Removed obsolete patch, made applying patches a hard failure in the build.
- How to verify it
Run the make and verify patches are applied.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
- Why I did it
To fix the above error when running make slave.mk with PLATFORM=vs.
- How I did it
Instead of:
export BUILD_MULTIASIC_KVM=$(BUILD_MULTIASIC_KVM)
do just the export:
export BUILD_MULTIASIC_KVM
BUILD_MULTIASIC_KVM is already defined to be either empty, or from rules/config or from the environment - from Makefile.work. No need to dereference the variable in the export statement.
- How to verify it
PLATFORM=vs make -f slave.mk list # verify no error and BUILD_MULTIASIC_KVM is empty in the output
PLATFORM=vs BUILD_MULTIASIC_KVM=y make -f slave.mk list # verify no error and BUILD_MULTIASIC_KVM is set to y in the output
Signed-off-by: Stepan Blyshchak <stepanb@nvidia.com>
Fix the nodesource.list cannot read issue, it is cased by the full path not used.
```
2021-12-03T06:59:26.0019306Z Removing intermediate container 77cfe980cd36
2021-12-03T06:59:26.0020872Z ---> 528fd40e60f6
2021-12-03T06:59:26.0021457Z Step 81/81 : RUN post_run_buildinfo
2021-12-03T06:59:26.0841136Z ---> Running in d804bd7e1b06
2021-12-03T06:59:29.1626594Z [91mDEPRECATION: Python 2.7 reached the end of its life on January 1st, 2020. Please upgrade your Python as Python 2.7 is no longer maintained. pip 21.0 will drop support for Python 2.7 in January 2021. More details about Python 2 support in pip can be found at https://pip.pypa.io/en/latest/development/release-process/#python-2-support pip 21.0 will remove support for this functionality.
2021-12-03T06:59:34.2960105Z [0m[91m/usr/bin/sed: can't read nodesource.list: No such file or directory
2021-12-03T06:59:34.5094880Z [0mThe command '/bin/sh -c post_run_buildinfo' returned a non-zero code: 2
```
Co-authored-by: Ubuntu <xumia@xumia-vm1.jqzc3g5pdlluxln0vevsg3s20h.xx.internal.cloudapp.net>
Fix no space left on device issue in tmpfs.
2021-12-01T06:30:40.1651742Z cp: write error: No space left on device
2021-12-01T06:30:40.1652225Z Failure: local_fs_run():/dev/vdb Unable to copy /tmp/tmp.gl4Sgp/onie-installer.bin to tmpfs
Updated BGP Template for the case:
1. For Packet Chassis do not advertise Loopback4096 address into BGP as there is Static Route for same.
Having this route in BGP causes two level of recursion in Zebra and cause assert in Zebra
when there are many nexthop involved
2. Advertise only P2P Connected IP's into BGP (External Peers). For Packet chassis we have backend IP Interface subnet and if
they get advertised into BGP then it also causes recursion
- Add INCLUDE_PINS to config to enable/disable container
- Add Docker files and supporting resources
- Add sonic-pins submodule and associated make files
Submission containing materials of a third party:
Copyright Google LLC; Licensed under Apache 2.0
#### Why I did it
Adds P4RT container to SONiC for PINS
The P4RT app is covered by this HLD:
https://github.com/pins/SONiC/blob/master/doc/pins/p4rt_app_hld.md
#### How I did it
Followed the pattern and templates used for other SONiC applications
#### How to verify it
Build SONiC with INCLUDE_P4RT set to "y".
Verify that the resulting build has a container called "p4rt" running.
You can verify that the service is up by running the following command on the SONiC switch:
```bash
sudo netstat -lpnt | grep p4rt
```
You should see the service listening on TCP port 9559.
#### Which release branch to backport (provide reason below if selected)
None
#### Description for the changelog
Build P4RT container for PINS
6f2d8d2110967d813053bcfcd8b34c42c5d0cda2 (HEAD -> 202111, origin/202111) [Voq][Inband] Support the Ethernet-IB port (#228
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
f81043b1f9ff02196629655f4735b33afd7f0ae1 (HEAD -> 202111, origin/202111) [port2alias]: Fix to get right number of return values (#1906)
bbbf65943ec46e9330eadaed8bcdf1612cb8bd55 [CLI][show bgp] On chassis don't show internal BGP sessions by default (#1927)
e12de7e7bf6cff3ec127f261bf88e4d29776d27b [port] Fix port speed set (#1952)
cae7af752d484956d7fe40e4c3a849ddad460976 Fix invalid output of syslog IPv6 servers (#1933)
6009341ddf790094166be5f0a81b4c114f00220b Routed subinterface enhancements (#1821)
6ab9d67ca6550c592b97afb513804be474f84eb0 Enhance sfputil for CMIS QSFP (#1949)
76cc67ba4f81c69b20efb3341808037c9db8f703 [debug dump] Refactoring Modules and Unit Tests (#1943)
cff58a8171423e4012bc8caf9748996a1e98b7e2 Add command reference for trap flow counters (#1876)
71cf3ee43524d56ad57dd90b937cfbf4bf63ba6a [Reclaim buffer] [Mellanox] Db migrator support reclaiming reserved buffer for unused ports (#1822)
e699b49fb722e6d6fe5a1d2dacd2d39eb085c1e4 Add show command for BFD sessions (#1942)
bb6c5774c843dbfad5f1ba00ee76dae7720902d1 [warm-reboot] Fix failures of warm reboot on disconnect of ssh session (#1529)
2e8bbb308477862a76d2327fcf696875e8f08650 Add trap flow counter support (#1868)
58407c1386ef13772a9a9320a795e380f162ab2c [load_minigraph] Delay pfcwd start until the buffer templates are rendered (#1937)
eb388e0584ba1fe8d8dba58f1c5a148036ffe047 [sonic-package-manager] support sonic-cli-gen and packages with YANG model (#1650)
2371d84e7d281bdb9988b5a1a012498dbbfb89ec generic_config_updater: Filename changed & VLAN validator added (#1919)
7c0718dfaf23289d4ecc3ada9332e465c9a4e56b [config reload] Update command reference (#1941)
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
c2aac75 [SFP-Refactor] Fix LP mode API issue (#247)
dba17c8 Firmware upgrade CLI support for QSFP-DD transceivers (#244)
cd69212 [SFP-Refactor] Implement CMIS Low Power mode (#237)
9cea07f Fix RegGroupField decode (#245)
6ae1909 Add CMIS QSFP support (#246)
c1f317d Gracefully handle CMIS APIs for passive modules (#238)
ec7335d fix for firmware functions (#243)
cf2ebe9 Fix RegBitField decode/encode (#242)
ef4f2c6 Fix SFP_CABLE_TECH_FIELD (#240)
e118644 remove time counting message in functions because function running time could be difficult to predict in unit tests (#241)
Signed-off-by: Prince George <prgeor@microsoft.com>
#### Why I did it
Updated hw-mgmt pointer to updated branch and to include new bugfixes. The hw-mgmt submodule was previously pointing to an orphaned commit which could not be fetched from github, this has now been resolved.
#### How I did it
Updated submodule pointer.
#### How to verify it
Clone down repository and update all submodules.
Bring in the following commit:
405f1df Use build profiles instead of distro version for Python 2 binding build (#558)
This change requires a corresponding change in this repo to set a build
profile to not build the python 2 bindings on Bullseye.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
Why I did it
Fix for issue #8389
How I did it
The /etc/rsyslog.conf is empty file which cause the FATAL of the process rsyslogd in the global instance database container. The function updateSyslogConf() should only generate the rsyslog.conf for containers in the namespace. it should not do it for the containers in the global instance. Instead, default rsyslog.conf should be used. Especially for database container, updateSyslogConf() is called before the database container is created. The result cause the sonic-cfggen failed to generate the rsyslog.conf.Why I did it
Fix for issue #8389
How I did it
The /etc/rsyslog.conf is empty file which cause the FATAL of the process rsyslogd in the global instance database container. The function updateSyslogConf() should only generate the rsyslog.conf for containers in the namespace. it should not do it for the containers in the global instance. Instead, default rsyslog.conf should be used. Especially for database container, updateSyslogConf() is called before the database container is created. The result cause the sonic-cfggen failed to generate the rsyslog.conf.
Signed-off-by: mlok <marty.lok@nokia.com>
This pull request integrate audisp-tacplus to SONiC for per-command accounting.
#### Why I did it
To support TACACS per-command accounting, we integrate audisp-tacplus project to sonic.
#### How I did it
1. Add auditd service to SONiC
2. Port and patch audisp-tacplus to SONiC
#### How to verify it
UT with CUnit to cover all new code in usersecret-filter.c
Also pass all current UT.
#### Which release branch to backport (provide reason below if selected)
N/A
#### Description for the changelog
Add audisp-tacplus for per-command accounting.
#### A picture of a cute animal (not mandatory but encouraged)
Why I did it
Fix some of the version files not used issue.
One of example version file version-py3-all-armhf, when building marvell-armhf, the version is used as expected, but it not use.
The BGP_VOQ_CHASSIS_NEIGHBOR keepalive and holdtime timers are
configured similar to general neighbors. Changes are done to configure
BGP_VOQ_CHASSIS_NEIGHBOR timers similar to BGP_INTENAL_NEIGBOR since voq
chassis bgp neighbors are similar to bgp internal neighbors in
multi-asic. As it is done for bgp internal neighbors, the keepalive and
holdtime timers are set to 3 and 10 seconds respectively. Also similar
to bgp internal neighbors, connection retry timer is also configured for
voq chassis bgp neighbors.
Signed-off-by: vedganes <vedavinayagam.ganesan@nokia.com>
Why I did it
Add bgpcfgd support to advertise routes.
How I did it
Make bgpcfgd subscribe to the ADVERTISE_NETWORK table in STATE_DB and configure route advertisement accordingly.
How to verify it
Added unit tests in bgpcfgd and verify on KVM about route advertisement.
- Consolidate the two [Service] sections by moving the ExecStartPre line for mark_dhcp_packet.py to the first section and removing the second.
- Make the mark_dhcp_packet.py file executable
- Also clean up mark_dhcp_packet.py
- Remove unused imports
- Fix spacing and line lengths to conform to PEP8
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
* Routed subinterfae enhancements HLD #833
* Adding python API support to get routed subinterface long name to get correct parent interface for the routed subinterface.
Signed-off-by: Stephen Sun stephens@nvidia.com
Why I did it
Support zero buffer profiles
Add buffer profiles and pool definition for zero buffer profiles
Support applying zero profiles on INACTIVE PORTS
Enable dynamic buffer manager to load zero pools and profiles from a JSON file
Dependency: It depends on Azure/sonic-swss#1910 and submodule advancing PR once the former merged.
How I did it
Add buffer profiles and pool definition for zero buffer profiles
If the buffer model is static:
Apply normal buffer profiles to admin-up ports
Apply zero buffer profiles to admin-down ports
If the buffer model is dynamic:
Apply normal buffer profiles to all ports
buffer manager will take care when a port is shut down
Update buffers_config.j2 to support INACTIVE PORTS by extending the existing macros to generate the various buffer objects, including PGs, queues, ingress/egress profile lists
Originally, all the macros to generate the above buffer objects took active ports only as an argument
Now that buffer items need to be generated on inactive ports as well, an extra argument representing the inactive ports need to be added
To be backward compatible, a new series of macros are introduced to take both active and inactive ports as arguments
The original version (with active ports only) will be checked first. If it is not defined, then the extended version will be called
Only vendors who support zero profiles need to change their buffer templates
Enable buffer manager to load zero pools and profiles from a JSON file:
The JSON file is provided on a per-platform basis
It is copied from platform/<vendor> folder to /usr/share/sonic/temlates folder in compiling time and rendered when the swss container is being created.
To make code clean and reduce redundant code, extract common macros from buffer_defaults_t{0,1}.j2 of all SKUs to two common files:
One in Mellanox-SN2700-D48C8 for single ingress pool mode
The other in ACS-MSN2700 for double ingress pool mode
Those files of all other SKUs will be symbol link to the above files
Update sonic-cfggen test accordingly:
Adjust example output file of JSON template for unit test
Add unit test in for Mellanox's new buffer templates.
How to verify it
Regression test.
Unit test in sonic-cfggen
Run regression test and manually test.