This is due to the fact that we use SONIC_OVERRIDE_BUILD_VARS internally
in our build jobs and this is not accounted in caching framework.
So we add MLNX_SDK_DEB_VERSION to force rebuild if we changed it via
SONIC_OVERRIDE_BUILD_VARS.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
#### Why I did it
- After [sonic-linux-kernel#177](https://github.com/Azure/sonic-linux-kernel/pull/177) changes, the I2C mux channels of Baseboard and Switchboard CPLDs are moved from i2c-4 and i2c-5 to i2c-36 and i2c-37 respectively.
- This caused QSFP driver initialization of i2c-36 to i2c-41 to fail causing the ports from Ethernet208 to Ethernet248 fail.
#### How I did it
- The fix to this problem is to change the order of QSFP driver initialization to I2C mux channels.
- Instead of the order i2c-10 to i2c-41, the order i2c-4 to i2c-35 is being utilized.
- Also, need to change the i2c-mux-channel number for Baseboard CPLD and switchboard CPLD in scripts to access them.
#### Why I did it
On our platforms syncd must be up while using the sonic_platform.
The issue is warm-reboot script first disables syncd then instantiate Chassis, which tries to connect syncd in __init__.
#### How I did it
Refactor Chassis to lazy initialize components.
Signed-off-by: Volodymyr Boyko <volodymyrx.boiko@intel.com>
Initialize fans and thermals lists on demand; make them properties in order to reduce Chassis object initialization time
Signed-off-by: Volodymyr Boyko <volodymyrx.boiko@intel.com>
- Why I did it
Update FW version to 2008_3110 fixing SN3800 specific warm boot scenario:
1. Disable interface
2. Warm Boot
3. Enable Interface --> link will remain down.
- How I did it
Use new FW that contains the fix for the problem mentioned above
- How to verify it
Run the scenario mentioned above and make sure that the link is up after warm boot
Signed-off-by: Dror Prital <drorp@nvidia.com>
Includes below comments:
```
fcf7cdc [patch] add patch "net: sch_generic: fix the missing new qdisc assignment bug" (#213)
```
#### Why I did it
To bring the fix "net: sch_generic: fix the missing new qdisc assignment bug".
#### How I did it
Updated submodule.
#### How to verify it
Build and run.
Verify that flapping a LAG member port does not lead to this member beeing stuck in disabled state.
Why I did it
7050 S4Q31 mmu configuration is missing ALPM configurations, causing not enough memory reserved for routes. Orchagent crashes on a nightly testbed with 6400 route entries.
How I did it
Add the missing ALPM configurations.
How to verify it
Load the configuration on testbed and verified new configuration exists and no more crash.
Signed-off-by: Ying Xie ying.xie@microsoft.com
Why I did it
In upgrade scenarios, where config_db.json is not carry forwarded to new image, it could be left w/o TACACS credentials.
Added a service to trigger 5 minutes after boot and restore TACACS, if /etc/sonic/old_config/tacacs.json is present.
How I did it
By adding a service, that would fire 5 mins after boot.
This service apply tacacs if available.
How to verify it
Upgrade and watch status of tacacs.timer & tacacs.service
You may create /etc/sonic/old_config/tacacs.json, with updated credentials
(before 5mins after boot) and see that appears in config & persisted too.
Which release branch to backport (provide reason below if selected)
201911
202006
202012
Why I did it
To enable syncd-rpc for Barefoot build
How I did it
Set the flag
How to verify it
ENABLE_SYNCD_RPC=y make configure PLATFORM=barefoot
ENABLE_SYNCD_RPC=y make all
#### Why I did it
To avoid the following error
```
Traceback (most recent call last):
File "/usr/local/bin/flush_unused_database", line 10, in <module>
if 'PONG' in output:
TypeError: a bytes-like object is required, not 'str'
```
`communicate` method returns the strings if streams were opened in text mode; otherwise, bytes.
In our case text arg in Popen is not true and that means that `communicate` return the bytes
#### How I did it
Set `text=True` to get strings instead of bytes
#### How to verify it
run `/usr/local/bin/flush_unused_database` inside database container
Why I did it
ndppd by default reads /proc/net/ipv6_route ever 30 seconds. Since T1s advertise so many routes to ToRs, this file is extremely large, and reading it causes ndppd's CPU usage to spike every 30 seconds
How I did it
Increase the delay for reading this file to the maximum possible value (max integer value), which will result in CPU spikes every ~24 days instead of every 30 seconds
How to verify it
Start ndppd with the new config file, confirm that no CPU spikes are seen except at startup
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
Build failed with error "Failed to verify the package"
The reason of the fail is version verification
Version manager didn't find dependencies for the barefoot platform
#### Why I did it
Support 2km cables for Microsoft SKUs
#### How I did it
1. Update pg_profile_lookup.ini with 2000m cable supported
2. Update buffer configuration for t1 with uplink cable 2000m
- For SN3800 platform:
- C64:
- t0: 32 100G down links and 32 100G up links.
- t1: 56 100G down links and 8 100G up links with 2 km cable.
- D112C8: 112 50G down links and 8 100G up links.
- D24C52: 24 50G down links, 20 100G down links, and 32 100G up links.
- D28C50: 28 50G down links, 18 100G down links, and 32 100G up links.
- For SN2700 platform:
- D48C8: 48 50G down links and 8 100G up links.
- C32:
- t0: 16 100G down links and 16 100G up links.
- t1: 24 100G down links and 8 100G up links with 2 km cable.
- For SN4600C platform:
- D112C8: 112 50G down links and 8 100G up links.
#### How to verify it
Run regression test
This PR contains the following changes
Original Arista-7050-QX-32S sku (32x40G ports) has been renamed to Arista-7050QX32S-Q32
Arista-7050-QX-32S is symlinked to Arista-7050QX-32S-S4Q31 (4x10G, 31x40G ports)
Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
The current code skips parsing bandwidth for DeviceMgmtLinks. We have a use case to set the speed for these type of links based on the bandwidth attribute in the minigraph
How to verify it
Ran sonic-cfggen on a minigraph and verified that interface of type DeviceMgmtLink has speed set in the PORT table from the bandwidth attribute in the minigraph
**- Why I did it**
- To fix failed test cases of Seastone-DX010 platform APIs that found on [platform_tests](https://github.com/Azure/sonic-mgmt/tree/master/tests/platform_tests/api) script
**- How I did it**
1. Add device/celestica/x86_64-cel_seastone-r0/platform.json
2. Update functions to support python3.7
3. Add more functions follow latest sonic_platform_base
4. Fix the bug
Signed-off-by: Yong Zhao yozhao@microsoft.com
Why I did it
This PR aims to monitor the memory usage of streaming telemetry container and restart streaming telemetry container if memory usage is larger than the pre-defined threshold.
How I did it
I borrowed the system tool Monit to run a script memory_checker which will periodically check the memory usage of streaming telemetry container. If the memory usage of telemetry container is larger than the pre-defined threshold for 10 times during 20 cycles, then an alerting message will be written into syslog and at the same time Monit will run the script restart_service to restart the streaming telemetry container.
How to verify it
I verified this implementation on device str-7260cx3-acs-1.
#### Why I did it
According to thermalctld hld, each fan must belong to a fan drawer, if the fan drawer does not physically exist, put fan into a virtual fan drawer. This PR is to clear fan from chassis._fan_list
#### How I did it
1. Don't put fan to chassis._fan_list
2. Always query fan from fan_drawer
Why I did it
Microsoft reported occasional daemon crashes on devices running 201911. On close inspection it was due to PMBus reads failing on IOError on very rare occasions.
This is the fix for 202012 branch.
How I did it
Add try/except block on performing reads on PMBus GPIOs.
How to verify it
Which release branch to backport (provide reason below if selected)
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
sonic-utilities:
* 8b98d45 2021-05-25 | [show] support for show muxcable firmware version of only active banks (#1629) (HEAD -> 202012) [vdahiya12]
* afd0975 2021-05-20 | [show] add support for muxcable metrics (#1615) [vdahiya12]
sonic-swss
* 7611df5 2021-05-27 | [tunneldecaporch] Set default MTU for the overlay loopback interface (#1756) (HEAD -> 202012) [Volodymyr Samotiy]
* 22fbb5c 2021-05-27 | [202012] Resolve neighbor when nexthop does not exist (#1759) (github/202012) [Shi Su]
* ec7710c 2021-05-27 | [Bulk mode] Limit the size of bulker (#1760) [Shi Su]
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
- Why I did it
Pick up fix from new hw-management package:
Fix gearbox thermal zone name, which was lack suffix thermal zone number
- How I did it
Update the hw-management version number in the make file
Update hw-management submodule pointer
- How to verify it
Run platform related test cases on Mellanox platform
Why I did it
Arista-7260CX3-Q64 is missing T1 MMU configuration.
How I did it
Define T1 MMU configuration for Arista-7260CX3-Q64.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
Why I did it
k8s handles in lower case, so the code ensures that it uses hostname in all lower case
How I did it
Wrapper for device_info.get_hostname that returns in lower case. This wrapper is used in all places that require hostname to use in kubectl commands.
How to verify it
Device joins successfully.
Why I did it
Currently, there is a bug in the ntp.conf jinja2 template where it will ignore the src_intf directive in CONFIG_DB if there are multiple IP addresses associated with an interface. This code change fixes that bug and allows the template to select the correct source interface for NTP.
How I did it
I did this by modifying the macro in ntp.conf.j2 which determines if there is an ip address associated with an interface to set a state variable when it detects a valid interface entry in CONFIG_DB instead of outputting "true" directly (which could result in multiple "trues" outputted for interfaces with multiple valid IP addresses).
How to verify it
Add two ipv4 addresses to an interface in SONiC
Add the following configuration to config_db.json
{
"NTP": {
"global": {
"src_intf": "Ethernet1"
}
}
}
Replace Ethernet1 with the interface name of the one you assigned the IP addresses to.
Run sudo config reload -y
Open /etc/ntp.conf and verify that the following line exists
...
interface listen Ethernet1
...
The interface specified should be the one set in the previous steps.
Description for the changelog
[ntp] Fix ntp.conf template to allow setting of source port in CONFIG_DB
Why I did it
This SAI change is to Enable TD2 platforms to also be able to handle VFP-based sub-interfaces.
This is the feature that is also needed for TD2 platforms.
How to verify it
Guohan and Team has validated this feature change on TD2 platforms
Signed-off-by: Neetha John nejo@microsoft.comFixes#7531
Why I did it
To enable bgp sessions to be established over subinterfaces
How I did it
Listen to VLAN_SUB_INTERFACE table in config db
How to verify it
Bgp sessions were established successfully over subinterface
#### Why I did it
The label for PSU related sensors on the Spectrum-2 platform is not aligned with the physical location of the PSU.
#### How I did it
Update the label in the sensor conf file for those relevant platforms
Signed-off-by: Kebo Liu <kebol@nvidia.com>
#### Why I did it
If a process limits using nodes by mempolicy/cpusets, and those nodes become memory exhaustion status, one process may be killed by oom-killer.
No panic occurs in this case, because other node's memory may be free.
This means system total status may be not fatal yet.
#### How I did it
Remove 'vm.panic_on_oom=1' kernel flag from 'vmcore-sysctl.conf '
Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
PG profile settings need to be aligned with Arista-7050-QX-32S
How I did it
Copy over the current settings from Arista-7050-QX-32S and define params for 10G and 1G speeds as well
Signed-off-by: Neetha John nejo@microsoft.comFixes#7531
Why I did it
To enable bgp sessions to be established over subinterfaces
How I did it
Listen to VLAN_SUB_INTERFACE table in config db
How to verify it
Bgp sessions were established successfully over subinterface
When FECDisabled is set to true in minigraph.py, push 'fec' 'none' explicitly to config_db. When 'fec' is defined in port_config.ini do not override it with 'rs' for 100G
Backport of #7667 to 202012 branch.