Why I did it
Fix PR merge failed because 'vstest' step does not install libyang.
How I did it
Install libyang in azure pipeline.
How to verify it
Pass vstest step.
- Why I did it
To include latest fixes and new functionality
SAI fixes and new features
fix#3205239, incorrect object type returned for SG child list
Fix VRF-VNI map entries remove issue
ECC health event and logging
[Port Buffers] restore default queue and pg configuration when all user pools are deleted
Fix EVPN type3 error on removal of uc/bc flood group
Fix EVPN type2 MAC move from local to remote results in SAI failure
Fix Disable learning on VXLAN tunnel
Fix error on VXLAN v6 tunnel removal
Fix port cannot apply schedule group when it is a lag member
Fix BFD add more detailed message on BFD packet not related to any existing session
gcc10 compilation fixes
Disable learning on VXLAN tunnel
Support BFD remote-disc exchange in negotiation stage
Tunnel Loopback packet action attribute implementation (for Dual TOR)
Add KVD resources MIN/MAX functionality (pending CRM issue with MIN only)
Support for CRC2 hash algorithm
Bulk counter support for PGs, queues
Support mirror sample rate attribute (SPC2+)
[Functional] [QoS] | Unable to remove SCHEDULE profile table even if there is no object referencing it
Next hop group optimized bulk API
Reduce verbosity of shared database already exists print
Span mirror policer (SPC2+), optimize pipeline for acl mirror action with policer on SPC2+
use same size descriptor pool for rx/tx
fix bfd - notify Sonic for admin-down event
2201 - empty list for supported fec for RJ45 ports
Fix don't disable used tunnel underlay interfaces
SDK fixes
100GbE FCI DAC (10137628-4050LF/HPE PN: 845408-B21) was recognized by mistake as supporting "cable burning' which caused the switch firmware to read page 0x9f (which unsupported in the cable) and to report this cable as having "bad eeprom".
Added remote peer UDP port information in BFD packet event.
After editing an ECMP, the resilient ECMP next-hop counter may not count correctly.
Fixed potential memory leaks in some APIs related to LPM
If TTL_CMD_COPY is used in Encap direction for a packet with no TTL, then the value passed in the ttl data structure will be used if non-zero (default 255 if zero).
In SN2201: When configuring Force mode, user should configure Speed and FEC on both sides
In Flex Tunnel encapsulation flow, if the encapsulation is with an IPv6 header, the flow label field may not be updated as expected.
In some cases, when changing speed to 400GbE over 8 lanes, the first few packets would be dropped.
In some traffic patterns involving small packets, the PortRcvErrors counter may mistakenly count events of local physical errors due to an internal flow in the hardware that involves link packets.
On Spectrum systems, sometimes during link failure, not all previous firmware indications cleared properly, potentially affecting the next link up attempt.
On the NVIDIA Spectrum-2 switch, when receiving a packet with Symbol Errors on ports that are configured to cut-thought mode, a pipeline might get stuck.
PCI calibration changes from a static to a dynamic mechanism.
SDK debug dump shows "Unknown" Counter in RFC3635 Counter Group.
SDK debug dump shows "Unknown" Counter in the PPCNT Traffic Class Counter Group.
SDK Dump missing column headers in some GC tables may result in difficulty understanding the dump.
SLL configuration is missing in SDK dump.
Spectrum-2 systems, do no support 1GbE on supported 40GbE modules.
When binding a UDP port which is already in use for BFD TX session, the error message appears incorrectly.
When Flex Tunnel was used, Flex Modifier sometimes experienced a brief mis-configuration during ISSU.
When many ports are active (e.g. 70 ports up), and the configuration of shared buffer is applied on the fly, occasionally, the firmware might get stuck.
When running 1GbE speeds on SN4600 system, the port remained active while peer side was closed.
When toggling many ports of the Spectrum devices while raising 10GbE link up and link maintenance is enabled, the switch may get stuck and may need to be rebooted.
When trying to reconfigure the Flex Parser header and Flex transition parameters after ISSU, the switch will returned an error even if the configuration was identical to that done before performing the ISSU.
While toggling the cable, and the low power mode is set to ON, an unexpected PMPE event error is received.
How I did it
Updated SDK/SAI submodule and relevant makefiles with the required versions.
- How to verify it
Build an image and run tests from "soni-mgmt".
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
linkmgrd:
* a0834e4 2022-09-22 | [Active-Active] server side admin forwarding state sync up (#133) (HEAD -> 202205) [Jing Zhang]
* ea56020 2022-09-21 | Post switchover reasons to STATE DB (#131) [Jing Zhang]
swss:
* d9cbf44 2022-09-24 | [orchagent] Fix issue: ip prefix shall be inited even if VRF/VNET is not ready (#2461) (HEAD -> 202205, github/202205) [Junchao-Mellanox]
* 3dcd6ff 2022-09-24 | [macsec]: Set MTU for MACsec (#2398) (#2466) [Ze Gan]
platform-daemon:
* 48b6239 2022-09-27 | [ycabled] add support for getting grpc secerts via shared file (#298) (HEAD -> 202205) [vdahiya12]
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
- Why I did it
Fix a typo in chassis platform API which causes the following error
>>> import sonic_platform as P
>>> c = P.platform.Platform().get_chassis()
>>> sl = c.get_all_sfps()
>>> sl[0].get_lpmode()
Sep 28 07:48:33 INFO LOG: Initializing SX log with STDOUT as output file.
False
>>> del c
Exception ignored in: <function Chassis.__del__ at 0x7f1d166ef8b0>
Traceback (most recent call last):
File "/usr/local/lib/python3.9/dist-packages/sonic_platform/chassis.py", line 126, in __del__
self.sfp_module.deinitialize_sdk_handle(sfp_module.SFP.shared_sdk_handle)
NameError: name 'sfp_module' is not defined
- How I did it
Use self while using the SDK handle
- How to verify it
Manual test
Signed-off-by: Stephen Sun <stephens@nvidia.com>
This reverts commit 9750cb4.
There is a PR to handle master branch revert: #12183
- Why I did it
The PR to be reverted introduced many notice logs every 1 minute if SFP is not plugged:
Cannot get module EEPROM information: Input/output error
Before the "bad" PR, the message format is like this:
INFO pmon#supervisord: xcvrd Cannot get module EEPROM information: Input/output error
It was truncated by rsyslog because every message is the same. However, the "bad" PR introduces SFP index to the message:
NOTICE pmon#xcvrd: Failed to get EEPROM data for sfp 39: Cannot get module EEPROM information: Input/output error
Rsyslog no longer truncate such log and many such messages are flooded to syslog.
- How I did it
Revert the PR
- How to verify it
Manual test
Update sonic-utilities submodule pointer to include the following:
* 99ed8ea [link-local]Modify RIF check to include link-local enabled interfaces ([#2394](https://github.com/Azure/sonic-utilities/pull/2394))
Signed-off-by: dgsudharsan <sudharsand@nvidia.com>
Signed-off-by: dgsudharsan <sudharsand@nvidia.com>
- Why I did it
ethtool print error logs when EEPROM of a SFP is not available. It prints error like this:
INFO pmon#/supervisord: xcvrd Cannot get module EEPROM information: Input/output error
INFO pmon#/supervisord: xcvrd Cannot get Module EEPROM data: Invalid argument
However, this log does not contain the relevant SFP index which is hard for developer/qa to find the exactly SFP.
- How I did it
Redirect ethtool stderr to subprocess and log it better
- How to verify it
Manual test
Why I did it
Current isc-dhcp uses below code to remove DHCP option:
memmove(sp, op, op[1] + 2);
sp += op[1] + 2;
sp points to the option to be stripped, we can call it as option S.
op points to the option after options S, we can call it as option O.
DHCP option is a typical type-length-value structure, the first byte is type, the second byte is length, and remain parts are value.
In this case, option O length is bigger than option S, and more than 2 bytes, after the memmove, we will get this result:
Now Option S and Option O are overwritten, op[1] was the length of Option O, and it's modified after memmove.
But current implementation is still using op[1] as length to update sp (sp+=op[1]+2), so we get the wrong sp.
How I did it
Create patch from https://github.com/isc-projects/dhcp
The new impelementation use mlen to store the length of Option O before memmove, that's how it fixed the bug.
size_t mlen = op[1] + 2;
memmove(sp, op, mlen);
sp += mlen;
How to verify it
I have a PR for sonic-mgmt to cover this issue:
sonic-net/sonic-mgmt#6330
Signed-off-by: Gang Lv ganglv@microsoft.com
- Why I did it
Update SDK/FW version - 4.5.2320/2010_2320 in order to have the following fixes:
• Spectrum-3 | PCI calibration changes from a static to a dynamic mechanism.
• [VxLAN] TTL was set to 0 for non IP traffic (such as ARP)
- How I did it
Update pointer for the SDK/FW
- How to verify it
Run regression tests
Why I did it
Some Arista products do not have an SSD but use an eMMC instead.
The SsdUtil plugin is therefore extended to support both.
How I did it
Implemented ssd_util.py platform plugin loaded by ssdutil.
This plugin fallback to the default SONiC implementation if the arista one can't be found.
How to verify it
Run show platform ssdhealth on a product with an eMMC
- Why I did it
interfaces-config service restarts networking service, during the restart loopback interface address is being removed and reassigned back, leaving loopback without an ipv4 address for a while.
On SONiC startup and config reload interfaces-config and bgp services start in parallel and sometimes
fpmsyncd in bgp attempts bind to loopback while it does not have an address, fails with the log
Exception "Cannot assign requested address" had been thrown in daemon
and exits with rc 0.
root@sonic:/# supervisorctl status
fpmsyncd EXITED Jul 20 05:04 AM
zebra RUNNING pid 35, uptime 6:15:05
zsocket EXITED Jul 20 05:04 AM
docker logs bgp
INFO exited: fpmsyncd (exit status 0; expected)
With fpmsyncd dead, configured routes do not appear in the database.
- How I did it
Added ordering dependency on interfaces-config service into bgp.config
- How to verify it
Itself the issue reproduces quite rarely, but one can gain the time interval between networking down and networking up in interfaces-config.sh like this:
diff --git a/files/image_config/interfaces/interfaces-config.sh b/files/image_config/interfaces/interfaces-config.sh
index f6aa4147a..87caceeff 100755
--- a/files/image_config/interfaces/interfaces-config.sh
+++ b/files/image_config/interfaces/interfaces-config.sh
@@ -63,7 +63,11 @@ done
# Read sysctl conf files again
sysctl -p /etc/sysctl.d/90-dhcp6-systcl.conf
-systemctl restart networking
+# systemctl restart networking
+
+systemctl start networking
+sleep 10
+systemctl stop networking
# Clean-up created files
rm -f /tmp/ztp_input.json /tmp/ztp_port_data.json
with this change the issue reproduces on every config reload.
Signed-off-by: Volodymyr Boyko <volodymyrx.boiko@intel.com>
Signed-off-by: maipbui maibui@microsoft.com
Why I did it
The xml.etree.ElementTree module is not secure against maliciously constructed data.
How I did it
Remove xml. Use lxml XML parsers package that prevent potentially malicious operation.
Multi-asic Docker instances are created behind Docker's default bridge
which doesn't allow talking to other Docker instances that are in the
host network (like database-chassis).
On linecards, we configure midplane interfaces to let per-asic docker
containers talk to CHASSIS_DB on the supervisor through internal chassis
network.
On the supervisor we don't need to use chassis internal network, but we
still need a similar setup in order to allow fabric containers to talk
to database-chassis
Why I did it
Enable syncd container autorestart for Innovium platforms
How I did it
Add critical_process file and sypervisord.conf entry
How to verify it
Tested with autorestart/test_container_autorestart.py::test_containers_autorestart
PASSED autorestart/test_container_autorestart.py::test_containers_autorestart[sonic-xxx-dut-sonic-xxx-dut|syncd]
Signed-off-by: rck-innovium rck@innovium.com
- Why I did it
To pickup new commit from sonic-swss-common submodule:
afd2382 [202205] Fix sonic-db-cli dictionary output format not backward compatible issue. sonic-net/sonic-swss-common#690
- How I did it
Advance the sonic-swss-common submodule pointer
Signed-off-by: Kebo Liu <kebol@nvidia.com>
Manually cherry-picking #11893
- Why I did it
The timer execution may fail if triggered during a config reload (when the sonic.target is stopped). This might happen in a rare situation if config reload is executed after reboot in a small time slot (for 0 to 30 seconds) before the tacacs-config timer is triggered:
systemctl status tacacs-config.timer
tacacs-config.timer - Delays tacacs apply until SONiC has started
Loaded: loaded (/lib/systemd/system/tacacs-config.timer; enabled-runtime; vendor preset: enabled)
Active: failed (Result: resources) since Mon 2022-08-29 15:53:03 IDT; 1min 28s ago
Trigger: n/a
Triggers: tacacs-config.service
Aug 29 15:47:53 r-boxer-sw01 systemd[1]: Started Delays tacacs apply until SONiC has started.
Aug 29 15:53:03 r-boxer-sw01 systemd[1]: tacacs-config.timer: Failed to queue unit startup job: Transaction for tacacs-config.service/start is destructive (mgmt-framework.timer has 's>
Aug 29 15:53:03 r-boxer-sw01 systemd[1]: tacacs-config.timer: Failed with result 'resources'.
- How I did it
To ensure that timer execution will be resumed after a config reload the WantedBy section of the systemd service is updated to describe relation to sonic.target.
- How to verify it
Reboot the system
After reboot monitor tacacs-config.timer status. 30 seconds before timer activation run "config reload -y" command.
Check system status.
Signed-off-by: Oleksandr Ivantsiv <oivantsiv@nvidia.com>
Update sonic-utilities submodule pointer to include the following:
[202205][subinterface]Added additional checks in portchannel and subinterface commands (#2371)
[202205] Use warm-boot infrastructure for fast-boot (#2365)
*The sonic-frr was upgraded to FRR 8.2.2 as part of PR #10691. However, sonic-frr/frr submodule was still referring to previous 7.5 version. Update the sonic-frr/frr submodule to 8.2.2 commit id. Fixes issue #11484.
Co-authored-by: Hasan Naqvi <56742004+hasan-brcm@users.noreply.github.com>
Update sonic-sairedis submodule pointer to include the following:
* [202205][SAI] advance SAI version to 1.10 to pick up saiserver and syncd-rpc support ([#1115](https://github.com/sonic-net/sonic-sairedis/pull/1115))
Signed-off-by: dprital <drorp@nvidia.com>
Signed-off-by: dprital <drorp@nvidia.com>
* Pin version of bazelisk to v1.13.0
This tries to avoid builds failures due to the latest version of
bazelisk changing and causing hash mismatches.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
Why I did it
bazelisk package with hash value 1227b24db77557d552701f6add122edc is deleted from github release.
Reproducible build only cached hash value. Package file didn't be cached. Because they are in different pipelines.
Using latest package hash instead.
Why I did it
This PR is to update TC_TO_QUEUE_MAP|AZURE for SKU Arista-7050CX3-32S-D48C8 and Arista-7260CX3 T0.
The change is only to align the TC_TO_QUEUE_MAP for regular traffic and bounced traffic. It has no impact on business because we have no traffic being mapped to TC2 or TC6.
How I did it
Update TC_TO_QUEUE_MAP|AZURE , and test cases as well.
How to verify it
Verified by running test case test_j2files.py
/sonic/src/sonic-config-engine$ python3 setup.py test -s tests/test_j2files.py
running test
......
----------------------------------------------------------------------
Ran 29 tests in 25.390s
OK
Why I did it
If the SWSS services was restarted, the MACsec service should also be restarted. Otherwise the data in wpa_supplicant and orchagent will not be consistent.
How I did it
Add dependency in docker-macsec.mk.
How to verify it
Manually check by 'sudo service swss restart'.
The MACsec container should be started after swss, the syslog will look like
Sep 8 14:36:29.562953 sonic INFO swss.sh[9661]: Starting existing swss container with HWSKU Force10-S6000
Sep 8 14:36:30.024399 sonic DEBUG container: container_start: BEGIN
...
Sep 8 14:36:33.391706 sonic INFO systemd[1]: Starting macsec container...
Sep 8 14:36:33.392925 sonic INFO systemd[1]: Starting Management Framework container...
Signed-off-by: Ze Gan <ganze718@gmail.com>
* [mux] skip mux operations during warm shutdown
- Enhance write_standby.py script to skip actions during warm shutdown.
- Expand the support to BGP service.
- MuX support was added by a previous PR.
- don't skip action during warm recovery
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
- Why I did it
Remove extra empty lines in the SN2201 pg_profile_lookup.ini to make it aligned with other platforms.
This extra empty line could confuse some test cases which need to parse this file.
Signed-off-by: Kebo Liu <kebol@nvidia.com>