Commit Graph

1151 Commits

Author SHA1 Message Date
Ikki Zhu
a2e244d3bd [Seastone] DX010 platform switch to sfp-refactor based sfp impl (#13972)
Why I did it
sonic-sfp based sfp impl would be deprecated in future, change to sfp-refactor based implementation.

How I did it
Use the new sfp-refactor based sfp implementation for seastone.

How to verify it
Manual test sfp platform api or run sfp platform test cases.
2023-04-03 16:34:16 +08:00
Neetha John
06939ffaec
[202205] [qos] Update RDMA-CENTRIC lossy profile to use static threshold for Th devices (#14399)
Backport #14372 to 202205

Why I did it
For better accounting purposes, updating the ingress lossy traffic profile to use static threshold. This change is only intended for Th devices using RDMA-CENTRIC profiles

How I did it
Update the buffer templates for Th devices in RDMA-CENTRIC folder to use the correct threshold

Signed-off-by: Neetha John <nejo@microsoft.com>
2023-03-24 10:42:15 -07:00
Pavan-Nokia
cb2e03da8e
[Nokia-7215]Update Marvell EZB XML files (#14261)
Update cnc-base counters to 4096 from 0 in the Marvell SAI
Easy bringup XML files
2023-03-17 10:58:55 -07:00
mssonicbld
32ac9b0bce
Update dynamic threshold for TD2 (#14224) (#14273)
Why I did it
Update dynamic threshold to -1 to get optimal performance for RDMA traffic

How I did it
Modified pg_profile_lookup.ini to reflect the correct value

Signed-off-by: Neetha John <nejo@microsoft.com>
Co-authored-by: Neetha John <nejo@microsoft.com>
2023-03-16 17:04:42 -07:00
Samuel Angebault
9ac78190ee [Arista] Add missing platform_components.json (#14067)
Provide platform-components.json for Clearwater2 and Wolverine

These files are needed for fwutil platform sonic-mgmt tests to pass.

Fix PikeZ platform_components.json

Co-authored-by: Patrick MacArthur <pmacarthur@arista.com>
Co-authored-by: Andy Wong <andywong@arista.com>
2023-03-16 04:32:32 +08:00
Jemston Fernando
f39bdaecf8
Fix Belgite platform issues (#14035)
As part of platform hardening this commit fixes several platform issues
in various components like PSU, FAN, Temperature, LED.
Cherrypick PR#13389
2023-03-15 19:29:00 +00:00
Sambath Kumar Balasubramanian
da348ecb79 sonic-buildimage Remove unused SAT port from arista configs. (#14167)
Why I did it
To fix aristanetworks/sonic#85

How I did it
Remove unnecessary SAT ports

How to verify it
Speed change from 400-100g without any error.
2023-03-14 04:32:42 +08:00
Ikki Zhu
3a8305d4b0 [Seastone] fix dx010 qsfp eeprom data write issue (#13930)
Why I did it
Platform cases test_tx_disable, test_tx_disable_channel, test_power_override failed in dx010.

How I did it
Add i2c access algorithm for CPLD i2c adapters.

How to verify it
Verify it with platform_tests/api/test_sfp.py::TestSfpApi test cases.
2023-03-06 16:39:26 +08:00
kenneth-arista
812c1aeecf
sonic-buildimage Make changes to arista config.bcm files to support max cores (#13831) (#14033)
To support 64 cores on arista skus. Fixes aristanetworks/sonic#77
Remapped recycle ports to lowers core port ids and set appl_param_nof_ports_per_modid to 64.

Co-authored-by: Sambath Kumar Balasubramanian <63021927+skbarista@users.noreply.github.com>
2023-03-02 13:08:00 -08:00
mssonicbld
ab6b3cde4e
Add QOS profiles for Arista SKUs (#13829) (#14040) 2023-03-02 14:51:41 +08:00
Stephen Sun
76a5c75b82 [Mellanox] Advance hw-mgmt to v.7.0020.4104 (#13372)
- Why I did it
Advance hw-mgmt service to V.7.0020.4100
Add missing thermal sensors that are supported by hw-mgmt package
Delay system health service before hw-mgmt has started on Mellanox platform in order to avoid reading some sensors before ready.
Depends on sonic-net/sonic-linux-kernel#305

- How I did it
1. Update hw mgmt version
2. Add missing sensors
3. Delay service 

- How to verify it
Regression test.

Signed-off-by: Stephen Sun <stephens@nvidia.com>
2023-03-01 12:38:50 +08:00
mssonicbld
e842241f71
add psu fans status led available config (#13926) (#13936) 2023-02-23 06:29:38 +08:00
Samuel Angebault
3c3a4ac517 [Arista] update sensors.conf to ignore sensors (#12529)
Why I did it
The sensors and sensord processes were reporting data on unused sensors.
This lead to ALARM messages or erroneous values that could be misinterpreted.

How I did it
Ignore the affected sensors in the sensors.conf

How to verify it
Check that there are no longer ALARM messages from sensord in the syslog or in the output of sensors
2023-02-22 04:33:53 +08:00
mssonicbld
e44b255555
[DX010 platform] fix dx010 platform testcase issues (#13595) (#13778)
Why I did it
1. fix chassis test_set_fans_led case
2. fix chassis get_name case mismatch issue
3. fix fan_drawer test_set_fans_speed
4. fix component test_components test case

How I did it
Add corresponding configuration into chassis json file

How to verify it
Run platform tests cases to verify these failure cases

Co-authored-by: Ikki Zhu <79439153+qnos@users.noreply.github.com>
2023-02-10 18:18:00 -08:00
mssonicbld
cdbdf95e70
fix platform.json on Wolverine for thermal sensors (#13524) (#13748)
Why I did it
The current platform.json contains entries for thermals and SFPs that do not exist on Wolverine.

How I did it
I removed the incorrect entries.

How to verify it
Verify using applicable sonic-mgmt platform API tests.

Co-authored-by: Patrick MacArthur <patrick@patrickmacarthur.net>
2023-02-10 14:39:00 -08:00
mssonicbld
268e866c02
[Celestica DX010] fix fan drawer and watchdog platform testcase issues (#13426) (#13747)
Why I did it
fix DX010 fan drawer and watchdog platform test case issues

How I did it
1. Add fan_drawer get_maximum_consumed_power support
2. Adjust maximum watchdog timeout value check

How to verify it
Run test_fan_drawer and test_watchdog test cases.

Co-authored-by: Ikki Zhu <79439153+qnos@users.noreply.github.com>
2023-02-10 09:19:38 -08:00
mssonicbld
06aa8aa11b
[Mellanox] Support DSCP remapping in dual ToR topo on T0 switch (#12605) (#13745)
- Why I did it
Support DSCP remapping in dual ToR topo on T0 switch for SKU Mellanox-SN4600c-C64, Mellanox-SN4600c-D48C40, Mellanox-SN2700, Mellanox-SN2700-D48C8.

- How I did it
Regarding buffer settings, originally, there are two lossless PGs and queues 3, 4. In dual ToR scenario, the lossless traffic from the leaf switch to the uplink of the ToR switch can be bounced back.
To avoid PFC deadlock, we need to map the bounce-back lossless traffic to different PGs and queues. Therefore, 2 additional lossless PGs and queues are allocated on uplink ports on ToR switches.

On uplink ports, map DSCP 2/6 to TC 2/6 respectively
On downlink ports, both DSCP 2/6 are still mapped to TC 1
Buffer adjusted according to the ports information:
Mellanox-SN4600c-C64:
56 downlinks 50G + 8 uplinks 100G
Mellanox-SN4600c-D48C40, Mellanox-SN2700, Mellanox-SN2700-D48C8:
24 downlinks 50G + 8 uplinks 100G

- How to verify it
Unit test.

Signed-off-by: Stephen Sun <stephens@nvidia.com>
Co-authored-by: Stephen Sun <5379172+stephenxs@users.noreply.github.com>
2023-02-10 09:16:56 -08:00
mssonicbld
c5998be1e2
[Arista] Add other chassis names to platform_components.json for 720DT-48S (#12378) (#13744)
Why I did it
The 720DT-48S platform has variants with different chassis names, and these need to all be included in platform_components.json to ensure that sonic-mgmt platform_tests/fwutil/test_fwutil.py::test_fwutil_show passes

How I did it
Updated platform_components.json with the variant names for 720DT-48S.

How to verify it
Ran aforementioned testcase and verified that it passes on the different variants.

Co-authored-by: andywongarista <78833093+andywongarista@users.noreply.github.com>
2023-02-10 09:15:57 -08:00
Marty Y. Lok
e6fde1d9e5
[Nokia][devicedata] Modified the port autoneg default setting for Nokia-7215 platform (#13459)
Why I did it
autoneg is not supported in the previous release 202012 on Nokia-7215 platform. To migrate to the 202205 image with autoneg support, we need to disable the autoneg to allow the link to be up when issue load minigraph. This requires to change the autoneg setting to be off in the port_config.ini file.

How I did it
Modify the port_config.ini to set the autoneg off.

How to verify it
Running the new image, with load mingraph.xml, execute "show int autonet status" should show autoneg disabled
2023-02-09 13:13:42 -08:00
mssonicbld
6083175d06
[device/arista] Reduce SDK stat polling freq in DNX devices (#13429) (#13604) 2023-02-03 07:53:34 +08:00
mssonicbld
900b809e12
[Arista] [Platform] Update platform.json for psu led (#13523) (#13583) 2023-02-02 05:18:55 +08:00
mssonicbld
b131127761
[Celestica Seastone] fix multi sonic platform issues (#13356) (#13485) 2023-01-24 05:06:54 +08:00
kenneth-arista
63bdc43b7f [device/arista] Disabled polled_irq_mode for DNX SKUs (#13349)
Disabled polled_irq_mode for all Arista DNX devices as this mode
leads to excessive use of the CPU via an unneeded interrupt
polling thread.
2023-01-21 04:32:08 +08:00
Ying Xie
07baa17a32 [Arista] add support for hardware sku Arista-7260CX3-D92C16 (#13438)
Signed-off-by: Ying Xie <ying.xie@microsoft.com>

Signed-off-by: Ying Xie <ying.xie@microsoft.com>
2023-01-20 06:33:02 +08:00
Tejaswini Chadaga
3c485e02b2
[202205] Update BRCM SAI version to 7.1.31.4 (#13346)
Why I did it
To bring in the following fixes:

Revert temporary fix added to disable SA equal DA drops
CS00012273013 - [7.1][J2, J2c+] Disable SA Equals DA trap on DNX
CS00012274222 - How to block the voq for given destination port for a flow from a remote mod-id
CS00012275381 - SAI_INGRESS_PRIORITY_GROUP_STAT_PACKETS is incremented for port's PG's even if there are no traffic sent to that PG
CS00012274433 - Local Fault and Remote Fault are not polled by linkscan thread
How I did it
Merged above fixes to SAI code

How to verify it
Validated by running the basic sanity tests on XGS and DNX chassis platforms including

fib/test_fib.py
decap/test_decap.py
drop_counters/test_drop_counters.py
arp/test_arpall.py
2023-01-12 23:49:24 -08:00
Marty Y. Lok
44b661f63b
[Nokia-7215] Update Nokia-7215 device data which is required by the new version of Marvell SAI 1.10.2-2 (#13278)
Why I did it
Update the Nokia-7215 device data which is required by the new version of the Marvell SAI 1.10.2-2 to fix the syncd crash issue.

How I did it
Update the device data in folder device/nokia/armhf-nokia_ixs7215_52x-r0 /Nokia-7215.

How to verify it
With this PR, syncd should be running fine. Syncd should not crash.

Signed-off-by: mlok <marty.lok@nokia.com>
2023-01-06 14:47:03 -08:00
Marty Y. Lok
ad3beb6905 [Nokia][device-data] Rename the port name in the port_config.ini and also remove ECN setting in the BCM config file (#13053)
Signed-off-by: mlok <marty.lok@nokia.com>
2023-01-05 12:37:26 +08:00
Ikki Zhu
83e87cd12a Seastone add platform capability enhancement config (#13079) 2023-01-05 12:37:23 +08:00
andywongarista
4a6c954e90 [Arista] Update ip packet checksum when set to 0xffff on 720DT-48S (#13088)
Why I did it
This is to fix test_forward_ip_packet_with_0xffff_chksum_tolerant test failure on 720DT-48S. IP packets with checksum set to 0xffff will be forwarded with the same checksum on this platform, instead of updating to the correct value.

How I did it
Add bcm config sai_verify_incoming_chksum=0 so that checksum is updated instead of being left unchanged when checksum is 0xffff. Note that packets with invalid checksum are still dropped with this config.
2023-01-05 12:37:20 +08:00
byu343
3226d06e3d [Arista]: Add hwSku Arista-7260CX3-D108C10 (#13242)
* [Arista]: Add hwSku Arista-7260CX3-D108C10

* Add buffer-related config for Arista-7260CX3-D108C10
2023-01-05 10:51:31 +08:00
mssonicbld
109275ac2a
Fix missing system_ref_core_clock_khz (#12663) (#13074)
Add missing system_ref_core_clock_khz in Arista-7800R3A-36D2-C36 and Arista-7800R3A-36D2-C72

Co-authored-by: Maxime Lorrillere <mlorrillere@arista.com>
2022-12-17 00:26:19 -08:00
mssonicbld
332480f4eb
DNX(J2/J2c/J2c+): Reserve Non-ECMP Fec Resource for Non-ECMP Route Nexthops/NBR Entries (#13076) (#13089) 2022-12-17 15:12:34 +08:00
mssonicbld
e1791fef42
Revert "[Arista] Disable pcie checking on x86_64-arista_7050cx3_32s (#12900)" (#13085)
This reverts commit dd87a791b4.

Co-authored-by: vaibhav-dahiya <vdahiya@microsoft.com>
2022-12-16 16:00:40 -08:00
mssonicbld
fd6523b423
Fix port index for multi-asic (#13042) (#13086)
Port indexes of front panel ports are not contiguous in multi-asic because we didn't distiguish between
front panel and internal ports, e.g., recycle ports. Fix this by assigning index to front panel port first
and then internal ports.

Co-authored-by: Song Yuan <64041228+ysmanman@users.noreply.github.com>
2022-12-16 14:56:12 -08:00
kenneth-arista
d410ebe645 Add aggregate port_config.ini for Wolverine SKU (#12951)
Add missing aggregate port_config.ini needed by sonic-mgmt

Concatenate the ASIC specific port_config.ini from device/arista/x86_64-arista_7800r3a_36d2_lc/Arista-7800R3A-36D2-C36/[01] to create the aggregate file.
2022-12-15 16:38:11 +08:00
mssonicbld
943ea1b005
[arista] Add platform.json for arista chassis LC5 (#12949) (#13027) 2022-12-13 07:39:07 +08:00
byu343
6a718a3685 [Arista] Disable pcie checking on x86_64-arista_7050cx3_32s (#12900)
This change is to disable the pcie firmware check done by Broadcom SAI. The change is needed for the Arista platform x86_64-arista_7050cx3_32s; otherwise, the check will fail, blocking the initialization.

There was a pcie firmware check added in brcm SDK and certain Arista hardwares do not compliant with the check, so we added the disable_pcie_firmware_check originally for x86_64-arista_7060dx4_32. For x86_64-arista_7050cx3_32s, it was able to pass the check but some firmware change done in August made it fail.
2022-12-09 06:32:36 +08:00
Jing Kan
f0f143ea62 [Arista 720DT] Create SKU alias Arista-720DT-G48S4 (#12905) 2022-12-08 04:32:58 +08:00
Ikki Zhu
776cb55d96 Seastone: fix platform fan psu and temperature issues (#12567)
Why I did it:
Fix multiple seastone platform issues caused by sonic kernel upgrade.

How I did it:
Get gpio base id with new label path in gpio sys fs.

How to verify it:
After the change, show platform fan/psustatus/temperature works well.
2022-12-08 02:37:56 +08:00
Neetha John
69343494dd Update ECN settings for storage backend (#12855)
Signed-off-by: Neetha John <nejo@microsoft.com>

Why I did it
ECN parameters need to be updated for storage backend

How I did it
Included the check for storage backend devices to update qos configs

How to verify it
Verified that the new ecn settings are applied on storage backend device.
Verified that the old ecn settings are applied for storage frontend, non storage frontend/backend devices
2022-12-01 01:36:46 +00:00
andywongarista
465cd9db8b [Arista] Enable ipv6 128b lpm on 720DT-48S (#12832)
Why I did it
Added to allow test_crm_route to pass; the test tries to add a /126 ipv6 route and this change is required in order for the count of available routes to be updated correctly.
2022-12-01 01:36:29 +00:00
bingwang-ms
4c44e4eb98 Add missing flags in qos template file (#12793) 2022-11-28 18:52:01 +00:00
Samuel Angebault
c9e467be7d [Arista] Update platform.json for 7060CX-32S (#12783)
Why I did it
Some sonic-mgmt platform_tests/api were failing on the 7060CX-32S

How I did it
Added the missing metadata in platform.json and platform_components.json
This is purely test data and does not impact our API implementation.

How to verify it
Run platform_tests / api and expect 100% pass rate.
2022-11-28 18:51:52 +00:00
Samuel Angebault
d32a3af99c [Arista] Update platform.json for 7260CX3-64 (#12757)
Why I did it
Some sonic-mgmt platform_tests/api were failing on the 7260CX3-64

How I did it
Added the missing metadata in platform.json and platform_components.json
This is purely test data and does not impact our API implementation.

How to verify it
Run platform_tests/api and expect 100% passrate.
2022-11-28 18:51:13 +00:00
bingwang-ms
4f7a0b4705 Apply separated DSCP_TO_TC_MAP and TC_TO_QUEUE_MAP to uplink ports on dualtor (#12730)
Why I did it
The PR is to apply separated DSCP_TO_TC_MAP and TC_TO_QUEUE_MAP to uplink ports on dualtor.
The traffic with DSCP 2 and DSCP 6 from T1 is treated as lossless traffic.

DSCP    TC    Queue
2      2     2
6      6     6
Traffic with DSCP 2 or DSCP 6 from downlink is still treated as lossy traffic as before.

How I did it
Define DSCP_TO_TC_MAP|AZURE_UPLINK and TC_TO_QUEUE_MAP|AZURE_UPLINK.

How to verify it
Verified by UT
Verified by coping the new template to a testbed, and rendering a config_db.json
2022-11-28 18:51:04 +00:00
wenyiz2021
547d3df694 [Arista] [platform] Add thermal info in platform.json (#12714)
add 1 more thermal entry
2022-11-28 18:50:55 +00:00
wenyiz2021
e663d7ea72 [arista] [chassis] Add psu/thermal info in platform.json for sup (#12667)
update psu info in platform.json on sup
2022-11-28 18:50:12 +00:00
Neetha John
92ae2bda5d [Profile separation] MMU infrastructure update for TD2 (#12626)
Signed-off-by: Neetha John <nejo@microsoft.com>

Why I did it
There is a need to have separate profiles on compute and storage and this infra update will help achieve that

How I did it
Moved buffer pool/profile and qos definitions on TD2 to a common folder and all TD2 hwsku's will reference that folder
2022-11-28 18:49:47 +00:00
Bohan Yang
18bdd154a6 [Arista]Add media_settings.json for x86_64-arista_7800r3a_36d2_lc (#12444)
Why I did it
TX FIR tuning should be done based on the type of inserted transceiver

How I did it
Add media_settings.json which contains the tuning data for 100G optic and 400G optic.

How to verify it
Tested against x86_64-arista_7800r3a_36d2_lc
2022-11-28 18:49:17 +00:00
Vivek
db09bef671 [Mellanox] [SKU] Added Mellanox-SN4700-A96C8V8 SKU (#12347)
- Why I did it
A new SKU for MSN4700 Platform i.e. Mellanox-SN4700-V16A96

Requirements:

Breakout:
Port 1-24: 4x25G(4)[10G,1G]
Port 25-28: 2x100G[200G,50G,40G,25G,10G,1G]
Port 29-32: 2x200G[100G,50G,40G,25G,10G,1G]
Downlinks: 96 (1-24) + 4 (25-28)
Uplinks: 4 (29-32)
Shared Headroom: Enabled
Over Subscribe Ratio: 1:4
Default Topology: T0
Default Cable Length for T1: 5m
VxLAN source port range set: No
Static Policy Based Hashing Supported: No

Additional Details:
QoS params: The default ones defined in qos_config.j2 will be applied
Small Packet Percentage: Used 50% for traditional buffer model Note: For dynamic model, the value defined in LOSSLESS_TRAFFIC_PATTERN|AZURE|small_packet_percentage is used
SKU was drafted under the assumption that the downlink ports uses xcvr's that will only support the first 4 lanes of the physical port they are connected to. Hence for the ports 1-24, the last four lanes are not used
Cable Lengths used for generating buffer_defaults_{t0,t1}.j2 values

Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>
2022-11-28 18:49:05 +00:00