Why I did it
When reboot the chassis by issuing "sudo reboot" on Supervisor card. The internal midplane communication xe0 should be shutdown to avoid double reboot on the linecard.
Added a udev link rule to disable the autoneg on AMD xgbe port Xe0 and Xe1 and make the setting in sync with the peer Broadcom greyhound ports.
How I did it
Modify the Nokia-7250IXRE specific reboot script on the Supervisor card to shutdown the internal interface xe0. Also move reboot linecard code to the top of the script to make sure the notification has been send to Linecard before shutdown the xe0 interface.
Introduced a new rule 80-net-by-driver.link to disable the autoneg on the AMD size. This change requires the latest NDK which contains the change to set the autoneg on the xe0 and xe1 port on the Greyhound.
Signed-off-by: mlok <marty.lok@nokia.com>
Why I did it
Support Egress Mirroring on supported Arista platforms
How I did it
Add necessary soc properties for egress mirroring recycle ports to be created
Signed-off-by: Nathan Wolfe <nwolfe@arista.com>
Updated asic_port_names for all Arista LC SKUs to follow latest naming
conventions to remove redundant ASICx suffix. For
Arista-7800R3-48CQ2-C48, added the asic_port_name mapping.
Why I did it
sonic-sfp based sfp impl would be deprecated in future, change to sfp-refactor based implementation.
How I did it
Use the new sfp-refactor based sfp implementation for seastone.
How to verify it
Manual test sfp platform api or run sfp platform test cases.
Why I did it
For better accounting purposes, updating the ingress lossy traffic profile to use static threshold. This change is only intended for Th devices using RDMA-CENTRIC profiles
How I did it
Update the buffer templates for Th devices in RDMA-CENTRIC folder to use the correct threshold
How to verify it
Verified the changes manually on a Th device.
Existing unit tests render Th template from the RDMA-CENTRIC folder. Updated the expected output to use the correct threshold
Why I did it
Update dynamic threshold to -1 to get optimal performance for RDMA traffic
How I did it
Modified pg_profile_lookup.ini to reflect the correct value
Signed-off-by: Neetha John <nejo@microsoft.com>
Provide platform-components.json for Clearwater2 and Wolverine
These files are needed for fwutil platform sonic-mgmt tests to pass.
Fix PikeZ platform_components.json
Co-authored-by: Patrick MacArthur <pmacarthur@arista.com>
Co-authored-by: Andy Wong <andywong@arista.com>
Why I did it
Platform cases test_tx_disable, test_tx_disable_channel, test_power_override failed in dx010.
How I did it
Add i2c access algorithm for CPLD i2c adapters.
How to verify it
Verify it with platform_tests/api/test_sfp.py::TestSfpApi test cases.
To support 64 cores on arista skus. Fixesaristanetworks/sonic#77
Remapped recycle ports to lowers core port ids and set appl_param_nof_ports_per_modid to 64.
Why I did it
Seastone does not have the psu fans' status led, need to reflect it in platform.json.
How I did it
Set the psu fans status led available to false.
How to verify it
Verify it with platform_tests/api/test_psu_fans.py::TestPsuFans::test_set_fans_led case.
Why I did it
The sensors and sensord processes were reporting data on unused sensors.
This lead to ALARM messages or erroneous values that could be misinterpreted.
How I did it
Ignore the affected sensors in the sensors.conf
How to verify it
Check that there are no longer ALARM messages from sensord in the syslog or in the output of sensors
Why I did it
This change specifies the tuning values for each lane of the B52 phy chips. These values can be different for different ports. The values being set are under the assumption of optical transceivers. This change depends on the change to sonic-swss: sonic-net/sonic-swss#2158.
How to verify it
We verified the values are correctly set on the B52 chips of Arista 7280cr3, by reading them from the debug cli of the B52 driver.
*Why I did it
The current sonic image bringup failed on Silverstone:
4:56:15.957705 sonic NOTICE swss#orchagent: :- addDecapTunnel: Create overlay loopback router interface oid:6000000000520
*How I did it
Enable bcm switch Tunnel function on Silverstone.
*How to verify it
The new sonic image can bringup OK on Silverstone.
- Why I did it
Advance hw-mgmt service to V.7.0020.4100
Add missing thermal sensors that are supported by hw-mgmt package
Delay system health service before hw-mgmt has started on Mellanox platform in order to avoid reading some sensors before ready.
Depends on sonic-net/sonic-linux-kernel#305
- How I did it
1. Update hw mgmt version
2. Add missing sensors
3. Delay service
- How to verify it
Regression test.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
Why I did it
1. fix chassis test_set_fans_led case
2. fix chassis get_name case mismatch issue
3. fix fan_drawer test_set_fans_speed
4. fix component test_components test case
How I did it
Add corresponding configuration into chassis json file
How to verify it
Run platform tests cases to verify these failure cases
Why I did it
The 720DT-48S platform has variants with different chassis names, and these need to all be included in platform_components.json to ensure that sonic-mgmt platform_tests/fwutil/test_fwutil.py::test_fwutil_show passes
How I did it
Updated platform_components.json with the variant names for 720DT-48S.
How to verify it
Ran aforementioned testcase and verified that it passes on the different variants.
Why I did it
The current platform.json contains entries for thermals and SFPs that do not exist on Wolverine.
How I did it
I removed the incorrect entries.
How to verify it
Verify using applicable sonic-mgmt platform API tests.
- Why I did it
Support DSCP remapping in dual ToR topo on T0 switch for SKU Mellanox-SN4600c-C64, Mellanox-SN4600c-D48C40, Mellanox-SN2700, Mellanox-SN2700-D48C8.
- How I did it
Regarding buffer settings, originally, there are two lossless PGs and queues 3, 4. In dual ToR scenario, the lossless traffic from the leaf switch to the uplink of the ToR switch can be bounced back.
To avoid PFC deadlock, we need to map the bounce-back lossless traffic to different PGs and queues. Therefore, 2 additional lossless PGs and queues are allocated on uplink ports on ToR switches.
On uplink ports, map DSCP 2/6 to TC 2/6 respectively
On downlink ports, both DSCP 2/6 are still mapped to TC 1
Buffer adjusted according to the ports information:
Mellanox-SN4600c-C64:
56 downlinks 50G + 8 uplinks 100G
Mellanox-SN4600c-D48C40, Mellanox-SN2700, Mellanox-SN2700-D48C8:
24 downlinks 50G + 8 uplinks 100G
- How to verify it
Unit test.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
Why I did it
Default pcieutil uses one configuration for all models of platform
How I did it
Take the configuration file as base for all models of concrete platform where model-specific devices are not listed in this configuration
How to verify it
Run pmon#pcied and verify that there is no error/warning logs on initialization step
Why I did it
fix DX010 fan drawer and watchdog platform test case issues
How I did it
1. Add fan_drawer get_maximum_consumed_power support
2. Adjust maximum watchdog timeout value check
How to verify it
Run test_fan_drawer and test_watchdog test cases.
Why I did it
By specifying 'status_led' 'controllable' to false for psu section, it means the platform is not yet supporting psu status led
How I did it
specify 'status_led' 'controllable' to false for psu section
How to verify it
by running test in pdb, manually add {'status_led' : {'controllable' : False}} in dictionary
this flag will be able to get False and skip testing:
ce290c735d/tests/platform_tests/api/test_psu.py (L337)
After upgrade to brcmsai 8.1, the sdk running environment (container) recommended with mininum memory size as below
TH4/TD4(ltsw) uses 512MB
TH3 used 300MB
Helix4/TD2/TD3/TH/TH 256 MB
Base on this requirement, adjust the default syncd share memory size and set the memory size for special ACISs in platform_env.conf file for different types of Broadcom ASICs.
How I did it
Add the platform_env.conf file if none of it for broadcom platform (base on platform_asic file)
Add the 'SYNCD_SHM_SIZE' and set the value
for ltsw(TD4/TH4) devices set to 512M at least (update the platform_env.conf)
for Td2/TH2/TH devices set to 256M
for TH3 set to 300M
verify
How to verify it
verify the image with code fix
Check with UT
Check on lab devices
On a problematic device which cannot start successfully
Run with the command
$ cat /proc/linux-kernel-bde
Broadcom Device Enumerator (linux-kernel-bde)
Module parameters:
maxpayload=128
usemsi=0
dmasize=32M
himem=(null)
himemaddr=(null)
DMA Memory (kernel): 33554432 bytes, 0 used, 33554432 free, local mmap
No devices found
$ docker rm -f syncd
syncd
$ sudo /usr/bin/syncd.sh start
Cannot get Broadcom Chip Id. Skip set SYNCD_SHM_SIZE.
Creating new syncd container with HWSKU Force10-S6000
a4862129a7fea04f00ed71a88715eac65a41cdae51c3158f9cdd7de3ccc3dd31
$ docker inspect syncd | grep -i shm
"ShmSize": 67108864,
"Tag": "fix_8.1_shm_issue.67873427-9f7ca60a0e",
On Normal device
$ docker inspect syncd | grep -i shm
"ShmSize": 268435456,
"Tag": "fix_8.1_shm_issue.67873427-9f7ca60a0e"
change the config syncd_shm.ini to b85=128m
$ docker rm -f syncd
syncd
$ sudo /usr/bin/syncd.sh start
Creating new syncd container with HWSKU Force10-S6000
3209ffc1e5a7224b99640eb9a286c4c7aa66a2e6a322be32fb7fe2113bb9524c
$ docker inspect syncd | grep -i shm
"ShmSize": 134217728,
"Tag": "fix_8.1_shm_issue.67873427-9f7ca60a0e",
change the config under
/usr/share/sonic/device/x86_64-dell_s6000_s1220-r0/Force10-S6000/platform_env.conf
and run command
$ cat /usr/share/sonic/device/x86_64-dell_s6000_s1220-r0/platform_env.conf
SYNCD_SHM_SIZE=300m
$ sudo /usr/bin/syncd.sh start
Creating new syncd container with HWSKU Force10-S6000
897f6fcde1f669ad2caab7da4326079abd7e811bf73f018c6dacc24cf24bfda5
$ docker inspect syncd | grep -i shm
"ShmSize": 314572800,
"Tag": "fix_8.1_shm_issue.67873427-9f7ca60a0e",
Signed-off-by: richardyu-ms <richard.yu@microsoft.com>
Eariler the SDK stat polling was erroneously set to once every msec
which is far more frequent than required by SWSS. The new setting, which
is consistent with other vendor SKUs, is once a second. The net result
is reduced CPU MHz by syncd.
Why I did it
Fix the following issues for Seastone platform:
- system-health issue: show system-health detail will not complete #9530, Celestica Seastone DX010-C32: show system-health detail fails with 'Chassis' object has no attribute 'initizalize_system_led' #11322
- show platform firmware updates issue: Celestica Seastone DX010-C32: show platform firmware updates #11317
- other platform optimization
How I did it
Modify and optimize the platform implememtation.
How to verify it
Manual run the test commands described in these issues.
Why I did it
Ragile adapter ra-b6510-32c ra-b6510-48v8c ra-b6910-64c ra-b6920-4s to kernel 5.x
Signed-off-by: “pettershao” pettershao@ragilenetworks.com
Fix code issue when SonicV2Connector.get() return None.
#### Why I did it
When database key does not exist, SonicV2Connector.get() will return None.
Code will break if not check return value.
#### How I did it
Check SonicV2Connector.get() return value before use it.
#### How to verify it
Pass all E2E test case.
Why I did it
Add two platform that support s3IP framework
How I did it
Add two platforms supporting S3IP SYSFS (TCS8400, TCS9400)
How to verify it
Manual test
Adding platform support for FS s5800-48t4s and s5800-48t8s-mars8p.
Both s5800-48t4s and s5800-48t8s-mars8p have 48 * 10/100/1000 Base-T ports, 4 * 10GE SFP+ Ports on Centec TsingMa.
s5800-48t4s is different from s5800-48t8s-mars8p in that:
The phy chip used by s5800-48t4s is Marvell 88e1680;
The phy chip used by s5800-48t4s-mars8p is Centec ctc21108;
Why I did it
This is to fix test_forward_ip_packet_with_0xffff_chksum_tolerant test failure on 720DT-48S. IP packets with checksum set to 0xffff will be forwarded with the same checksum on this platform, instead of updating to the correct value.
How I did it
Add bcm config sai_verify_incoming_chksum=0 so that checksum is updated instead of being left unchanged when checksum is 0xffff. Note that packets with invalid checksum are still dropped with this config.
Why I did it
On DNX (J2/J2c/J2c+) platforms, Single Path Nexthops and ECMp Nexthop resources(FECs) are shared. BRCM SAI do not have partition of this resource, and hence more single path Nexthop entries, causes ECMP programming to fail in scaled setup.
How I did it
Broadcom provided SAI changes to reserve resources for single path nexthop entries(More details in CSP: https://brcmsemiconductor-csm.wolkenservicedesk.com/wolken-support/allcases/request-details?requestId=CS00012251649).
Along with SAI changes, they provided configurable Macro/flag to reserve NON_ECMP entries.
This PR is to add that flag in various sai.profile files wherever applicable.
PS: We are reserving 3072 single path Nexthop entries on each Linecard. Calculation is as follows.
Max Slots per chassis: 8
Max No of Ports(each LC): 64
MyIP/Subnet Entries per port: 4(v4/v6)
Nbr Entries Per port: 2(v4/v6)
Total Non_ECMP Count: 8x64x(4+2) = 3072
How to verify it
Without this change, the ECMP group count will be shown as Max_count in 'crm show resources all' command, and with this change the ECMP group count will be decreased by 24(3072/128).
Port indexes of front panel ports are not contiguous in multi-asic because we didn't distiguish between
front panel and internal ports, e.g., recycle ports. Fix this by assigning index to front panel port first
and then internal ports.
Add missing aggregate port_config.ini needed by sonic-mgmt
Concatenate the ASIC specific port_config.ini from device/arista/x86_64-arista_7800r3a_36d2_lc/Arista-7800R3A-36D2-C36/[01] to create the aggregate file.
Signed-off-by: maipbui <maibui@microsoft.com>
Dependency: [PR (#12065)](https://github.com/sonic-net/sonic-buildimage/pull/12065) needs to merge first.
#### Why I did it
1. `eval()` - not secure against maliciously constructed input, can be dangerous if used to evaluate dynamic content. This may be a code injection vulnerability.
2. `subprocess()` - when using with `shell=True` is dangerous. Using subprocess function without a static string can lead to command injection.
3. `os` - not secure against maliciously constructed input and dangerous if used to evaluate dynamic content.
4. `is` operator - string comparison should not be used with reference equality.
5. `globals()` - extremely dangerous because it may allow an attacker to execute arbitrary code on the system
#### How I did it
1. `eval()` - use `literal_eval()`
2. `subprocess()` - use `shell=False` instead. use an array string. Ref: [https://semgrep.dev/docs/cheat-sheets/python-command-injection/#mitigation](https://semgrep.dev/docs/cheat-sheets/python-command-injection/#mitigation)
3. `os` - use with `subprocess`
4. `is` - replace by `==` operator for value equality
5. `globals()` - avoid the use of globals()
This change is to disable the pcie firmware check done by Broadcom SAI. The change is needed for the Arista platform x86_64-arista_7050cx3_32s; otherwise, the check will fail, blocking the initialization.
There was a pcie firmware check added in brcm SDK and certain Arista hardwares do not compliant with the check, so we added the disable_pcie_firmware_check originally for x86_64-arista_7060dx4_32. For x86_64-arista_7050cx3_32s, it was able to pass the check but some firmware change done in August made it fail.
Why I did it:
Fix multiple seastone platform issues caused by sonic kernel upgrade.
How I did it:
Get gpio base id with new label path in gpio sys fs.
How to verify it:
After the change, show platform fan/psustatus/temperature works well.
Signed-off-by: maipbui <maibui@microsoft.com>
Dependency: [https://github.com/sonic-net/sonic-buildimage/pull/12065](https://github.com/sonic-net/sonic-buildimage/pull/12065)
#### Why I did it
`subprocess.Popen()` and `subprocess.run()` is used with `shell=True`, which is very dangerous for shell injection.
`os` - not secure against maliciously constructed input and dangerous if used to evaluate dynamic content
`getstatusoutput` is dangerous because it contains `shell=True` in the implementation
#### How I did it
Replace `os` by `subprocess`, use with `shell=False`
Remove unused functions
#### Why I did it
`os` and `commands` modules are not secure against maliciously constructed input
`getstatusoutput` is detected without a static string, uses `shell=True`
#### How I did it
Eliminate the use of `os` and `commands`
Use `subprocess` instead
Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
ECN parameters need to be updated for storage backend
How I did it
Included the check for storage backend devices to update qos configs
How to verify it
Verified that the new ecn settings are applied on storage backend device.
Verified that the old ecn settings are applied for storage frontend, non storage frontend/backend devices
Signed-off-by: maipbui <maibui@microsoft.com>
#### Why I did it
The [xml.etree.ElementTree](https://docs.python.org/3/library/xml.etree.elementtree.html#module-xml.etree.ElementTree) module is not secure against maliciously constructed data.
`os` - not secure against maliciously constructed input and dangerous if used to evaluate dynamic content
`subprocess.getstatusoutput` is dangerous because include shell=True in the implementation
#### How I did it
Remove xml. Use [lxml](https://pypi.org/project/lxml/) XML parsers package that prevent potentially malicious operation.
Replace `os` by `subprocess`
Use command as an array instead of string
Use `getstatusoutput_noshell` in `sonic_py_common` lib
Why I did it
Added to allow test_crm_route to pass; the test tries to add a /126 ipv6 route and this change is required in order for the count of available routes to be updated correctly.
Why I did it
TX FIR tuning should be done based on the type of inserted transceiver
How I did it
Add media_settings.json which contains the tuning data for 100G optic and 400G optic.
How to verify it
Tested against x86_64-arista_7800r3a_36d2_lc
Why I did it
The PR is to apply separated DSCP_TO_TC_MAP and TC_TO_QUEUE_MAP to uplink ports on dualtor.
The traffic with DSCP 2 and DSCP 6 from T1 is treated as lossless traffic.
DSCP TC Queue
2 2 2
6 6 6
Traffic with DSCP 2 or DSCP 6 from downlink is still treated as lossy traffic as before.
How I did it
Define DSCP_TO_TC_MAP|AZURE_UPLINK and TC_TO_QUEUE_MAP|AZURE_UPLINK.
How to verify it
Verified by UT
Verified by coping the new template to a testbed, and rendering a config_db.json
Why I did it
Some sonic-mgmt platform_tests/api were failing on the 7060CX-32S
How I did it
Added the missing metadata in platform.json and platform_components.json
This is purely test data and does not impact our API implementation.
How to verify it
Run platform_tests / api and expect 100% pass rate.
Why I did it
Some sonic-mgmt platform_tests/api were failing on the 7260CX3-64
How I did it
Added the missing metadata in platform.json and platform_components.json
This is purely test data and does not impact our API implementation.
How to verify it
Run platform_tests/api and expect 100% passrate.
Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
There is a need to have separate profiles on compute and storage and this infra update will help achieve that
How I did it
Moved buffer pool/profile and qos definitions on TD2 to a common folder and all TD2 hwsku's will reference that folder
Why I did it
Fixes#12614
How I did it
In the container_checker the database_chassis is added to expected container if device is supervisor
To detect the device is superviso, add supervisor=1 to the platform_env.conf of 7808 sup platform
How to verify it
run container_checker monit check
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
Signed-off-by: maipbui <maibui@microsoft.com>
#### Why I did it
`subprocess.Popen()` and `subprocess.run()` is used with `shell=True`, which is very dangerous for shell injection.
`os` - not secure against maliciously constructed input and dangerous if used to evaluate dynamic content
#### How I did it
Replace `os` by `subprocess`
Remove unused functions
Why I did it
This changes should go with updated SDE for BFN. Without update we do see orchagent core dump.
How I did it
Revert changes
How to verify it
Deploy topology. No core dump appears
- Why I did it
A new SKU for MSN4700 Platform i.e. Mellanox-SN4700-V16A96
Requirements:
Breakout:
Port 1-24: 4x25G(4)[10G,1G]
Port 25-28: 2x100G[200G,50G,40G,25G,10G,1G]
Port 29-32: 2x200G[100G,50G,40G,25G,10G,1G]
Downlinks: 96 (1-24) + 4 (25-28)
Uplinks: 4 (29-32)
Shared Headroom: Enabled
Over Subscribe Ratio: 1:4
Default Topology: T0
Default Cable Length for T1: 5m
VxLAN source port range set: No
Static Policy Based Hashing Supported: No
Additional Details:
QoS params: The default ones defined in qos_config.j2 will be applied
Small Packet Percentage: Used 50% for traditional buffer model Note: For dynamic model, the value defined in LOSSLESS_TRAFFIC_PATTERN|AZURE|small_packet_percentage is used
SKU was drafted under the assumption that the downlink ports uses xcvr's that will only support the first 4 lanes of the physical port they are connected to. Hence for the ports 1-24, the last four lanes are not used
Cable Lengths used for generating buffer_defaults_{t0,t1}.j2 values
Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>
- Why I did it
Barefoot uses hysteresis, instead of 'xon-threshold'. 'xon' is only
supported in static mode, so there is a need to add this attribute
to every mode in PG profile init file
- How I did it
'xon_offset' was added to pg_profile_lookup.ini
- How to verify it
Install and basic sanity tests including traffic.
Checked with:
pfcwd/test_pfc_config.py pfcwd/test_pfcwd_all_port_storm.py
pfcwd/test_pfcwd_function.py pfcwd/test_pfcwd_war_reboot.py
pfc_asym/test_pfc_asym.py
Signed-off-by: Mariusz Stachura <mariusz.stachura@intel.com>
Signed-off-by: Mariusz Stachura <mariusz.stachura@intel.com>
Signed-off-by: Mariusz Stachura <mariusz.stachura@intel.com>
What I did
Adding the dynamic headroom calculation support for Barefoot platforms.
Why I did it
Enabling dynamic mode for barefoot case.
How I verified it
The community tests are adjusted and pass.
A new SKU for MSN4700 Platform i.e. Mellanox-SN4700-V48C32
Requirements:
Breakout:
Port 1-24: 2x200G
Port 25-32: 4x100G
Downlinks: 48 (1-24)
Uplinks: 32 (25-32)
Shared Headroom: Enabled
Over Subscribe Ratio: 1:8
Default Topology: T1
Default Cable Length for T1: 300m
VxLAN source port range set: No
Static Policy Based Hashing Supported: No
Additional Details:
QoS params: The default ones defined in qos_config.j2 will be applied
Small Packet Percentage: Used 50% for traditional buffer model Note: For dynamic model, the value defined in LOSSLESS_TRAFFIC_PATTERN|AZURE|small_packet_percentage is used
Cable Lengths used for generating buffer_defaults_{t0,t1}.j2 values
Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>
#### Why I did it
To add new SKU Mellanox-SN2700-D44C10 with following requirements:
| Port configuration | Value |
| ------ |--------- |
| Breakout mode for each port |**Defined in port mapping** |
| Speed of the port | **Defined in Port mapping** |
| Auto-negotiation enable/disable | **No setting required** |
| FEC mode | **No setting required** |
|Type of transceiver used | **Not needed**|
Buffer configuration | Value
------ |---------
Shared headroom | **Enabled**
Shared headroom pool factor | **2**
Dynamic Buffer | **Disable**
In static buffer scenario how many uplinks and downlinks? | **44 x50G and 2x100G Downlinks 8x100G uplinks**
2km cable support required? | **No**
Switch configuration | Value
------ |---------
Warmboot enabled? | **yes**
Should warmboot be added to SAI profile when enabled? | **yes**
Is VxLAN source port range set? | **No**
Should Vxlan source port range be added to SAI profile when set. | **No**
Is Static Policy Based Hashing enabled? | **No**
Port Mapping
| Ports | Mode |
| ------ |--------- |
| 1,2 | 1x100G |
| 3-6 | 2x50G |
| 7-10 | 1x100G |
| 11-22 | 2x50G |
| 23-26 | 1x100G |
| 27-32 | 2x50G |
Number of Uplinks / Downlinks:
TO topology: **44 x50G and 2x100G Downlinks 8x100G uplinks**.
#### How I did it
Defined the SKU as per requirements
#### How to verify it
Load the SKU and verify if all links come up and traffic passes.
Signed-off-by: maipbui <maibui@microsoft.com>
#### Why I did it
`eval()` - not secure against maliciously constructed input, can be dangerous if used to evaluate dynamic content. This may be a code injection vulnerability.
#### How I did it
`eval()` - use `literal_eval()`
changed the platform device name under nokia directory; we now need to specify marvell armhf/arm64 to provide more accurate platform identity. otherwise onie discovery won't recognize the asic being installed.
Why I did it
when we load images using onie discovery, the process was failing because of marvell ASIC mismatch
How I did it
replace the platform asic with marvell-armhf under 7215
How to verify it
load a new image using http server and verify that the image can be loaded successfully
Why I did it
For the change to support gearbox taps by gearbox_config.json (sonic-net/sonic-swss#2158), I need to add tests to sonic-swss/tests/test_gearbox.py to satisfy the test coverage of the change. The existing code in test_gearbox.py has already used brcm_gearbox_vs and here is to add some gearbox tap value to its gearbox_config.json, for the added tests in sonic-swss/tests/test_gearbox.py.
How I did it
How to verify it
This change itself will not affect existing code.
Signed-off-by: maipbui <maibui@microsoft.com>
#### Why I did it
`subprocess.Popen()` and `subprocess.run()` is used with `shell=True`, which is very dangerous for shell injection.
`os` - not secure against maliciously constructed input and dangerous if used to evaluate dynamic content
#### How I did it
Replace `os` by `subprocess`, remove `shell=True`
Remove unused functions
Signed-off-by: maipbui <maibui@microsoft.com>
Dependency: [PR (#12065)](https://github.com/sonic-net/sonic-buildimage/pull/12065) needs to merge first.
#### Why I did it
`subprocess.Popen()` and `subprocess.check_output()` is used with `shell=True`, which is very dangerous for shell injection.
#### How I did it
Disable `shell=True`, enable `shell=False`
#### How to verify it
Tested on DUT, compare and verify the output between the original behavior and the new changes' behavior.
[testresults.zip](https://github.com/sonic-net/sonic-buildimage/files/9550867/testresults.zip)
Why I did it
Add components data for sonic-mgmt testing
How I did it
Update platform.json and add platform_components.json
How to verify it
Ran sonic-mgmt tests (test_chassis and test_component)
Why I did it
Some Arista products do not have an SSD but use an eMMC instead.
The SsdUtil plugin is therefore extended to support both.
How I did it
Implemented ssd_util.py platform plugin loaded by ssdutil.
This plugin fallback to the default SONiC implementation if the arista one can't be found.
How to verify it
Run show platform ssdhealth on a product with an eMMC
Multi-asic Docker instances are created behind Docker's default bridge
which doesn't allow talking to other Docker instances that are in the
host network (like database-chassis).
On linecards, we configure midplane interfaces to let per-asic docker
containers talk to CHASSIS_DB on the supervisor through internal chassis
network.
On the supervisor we don't need to use chassis internal network, but we
still need a similar setup in order to allow fabric containers to talk
to database-chassis
Why I did it
This PR is to update TC_TO_QUEUE_MAP|AZURE for SKU Arista-7050CX3-32S-D48C8 and Arista-7260CX3 T0.
The change is only to align the TC_TO_QUEUE_MAP for regular traffic and bounced traffic. It has no impact on business because we have no traffic being mapped to TC2 or TC6.
How I did it
Update TC_TO_QUEUE_MAP|AZURE , and test cases as well.
How to verify it
Verified by running test case test_j2files.py
/sonic/src/sonic-config-engine$ python3 setup.py test -s tests/test_j2files.py
running test
......
----------------------------------------------------------------------
Ran 29 tests in 25.390s
OK
- Why I did it
Remove extra empty lines in the SN2201 pg_profile_lookup.ini to make it aligned with other platforms.
This extra empty line could confuse some test cases which need to parse this file.
Signed-off-by: Kebo Liu <kebol@nvidia.com>
Why I did it
After PFC interop testing between 8102 and 7050cx3, data packet losses were observed on the Rx ports of the 7050cx3 (inflow from 8102) during testing. This was primarily due to the slower response times to react to PFC pause packets for the 8102, when receiving such frames from neighboring devices. To solve for the packet drops, the 7050cx3 pg headroom size has to be increased to 160kB.
How I did it
Modified the xoff threshold value to 160kB in the pg_profile file to allow for the buffer manager to read that value when building the image, and configuring the device
How to verify it
run "mmuconfig -l" once image is built
Signed-off-by: dojha <devojha@microsoft.com>
* Update sensor names for msn4600c for the 5.10 kernel
Looks like a sensor was removed in the 5.10 kernel for the tps53679
sensor, so the names/indexing has changed.
Related to Azure/sonic-mgmt#4513.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
* Update sensors file
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
Why I did it
Content of platform.json was outdated and some platform_tests/api of sonic-mgmt were failing.
How I did it
Added the necessary values to platform.json
How to verify it
Running platform_tests/api of sonic-mgmt should yield 100% passrate.
Why I did it
S5296F - Platform API 2.0 changes
How I did it
Implemented the functional API's needed for Platform API 2.0
How to verify it
Used the API 2.0 test suite to validate the test cases.
- Why I did it
This new breakout mode is required when a QSFP cable is used on the QSFP-DD supported 4700 port. since QSFP only uses the first 4 lanes, this mode is required to restrict the child ports to only use the first four lanes
- How I did it
Updated the platfrom.json file with the extended data
- How to verify it
Tested on one port:
root@msn-4700:/home/admin# show int status
Interface Lanes Speed MTU FEC Alias Vlan Oper Admin Type Asym PFC
----------- ------------------------------- ------- ----- ----- ------- ------ ------ ------- ----------------------------------------------- ----------
Ethernet0 0 25G 9100 N/A etp1a routed up up QSFP28 or later N/A
Ethernet1 1 25G 9100 N/A etp1b routed down up N/A N/A
Ethernet2 2 25G 9100 N/A etp1c routed down up N/A N/A
Ethernet3 3 25G 9100 N/A etp1d routed down up N/A N/A
Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>
#### Why I did it
Update scripts in sonic-buildimage from py-swsssdk to swsscommon
#### How I did it
Replace swsssdk with swsscommon in alphanetworks devices code.
#### How to verify it
Pass all E2E test case
#### Which release branch to backport (provide reason below if selected)
<!--
- Note we only backport fixes to a release branch, *not* features!
- Please also provide a reason for the backporting below.
- e.g.
- [x] 202006
-->
- [ ] 201811
- [ ] 201911
- [ ] 202006
- [ ] 202012
- [ ] 202106
- [ ] 202111
- [ ] 202205
#### Description for the changelog
Replace swsssdk with swsscommon in alphanetworks devices code.
#### Link to config_db schema for YANG module changes
<!--
Provide a link to config_db schema for the table for which YANG model
is defined
Link should point to correct section on https://github.com/Azure/sonic-buildimage/blob/master/src/sonic-yang-models/doc/Configuration.md
-->
#### A picture of a cute animal (not mandatory but encouraged)
#### Why I did it
Update scripts in sonic-buildimage from py-swsssdk to swsscommon
#### How I did it
Replace swsssdk with swsscommon in centec devices.
#### How to verify it
Pass all E2E test case
#### Which release branch to backport (provide reason below if selected)
<!--
- Note we only backport fixes to a release branch, *not* features!
- Please also provide a reason for the backporting below.
- e.g.
- [x] 202006
-->
- [ ] 201811
- [ ] 201911
- [ ] 202006
- [ ] 202012
- [ ] 202106
- [ ] 202111
- [ ] 202205
#### Description for the changelog
Replace swsssdk with swsscommon in centec devices.
#### Link to config_db schema for YANG module changes
<!--
Provide a link to config_db schema for the table for which YANG model
is defined
Link should point to correct section on https://github.com/Azure/sonic-buildimage/blob/master/src/sonic-yang-models/doc/Configuration.md
-->
#### A picture of a cute animal (not mandatory but encouraged)
#### Why I did it
Update scripts in sonic-buildimage from py-swsssdk to swsscommon
#### How I did it
Remove unused swsssdk import from accton device code
#### How to verify it
Pass all E2E test case
#### Which release branch to backport (provide reason below if selected)
<!--
- Note we only backport fixes to a release branch, *not* features!
- Please also provide a reason for the backporting below.
- e.g.
- [x] 202006
-->
- [ ] 201811
- [ ] 201911
- [ ] 202006
- [ ] 202012
- [ ] 202106
- [ ] 202111
- [ ] 202205
#### Description for the changelog
Remove unused swsssdk import from accton device code
#### Link to config_db schema for YANG module changes
<!--
Provide a link to config_db schema for the table for which YANG model
is defined
Link should point to correct section on https://github.com/Azure/sonic-buildimage/blob/master/src/sonic-yang-models/doc/Configuration.md
-->
#### A picture of a cute animal (not mandatory but encouraged)
Signed-off-by: maipbui maibui@microsoft.com
Why I did it
The xml.etree.ElementTree module is not secure against maliciously constructed data.
How I did it
Remove xml. Use lxml XML parsers package that prevent potentially malicious operation.
# Why I did it
platform-modules-belgite's deb requests linux-image-5.10.0-8-2-amd64-unsigned, which does not match the runtime kernel version
# How I did it
update the belgite's deb configuration in deb's control
# How to verify it
check the firsttime boot log in belgite platform
Co-authored-by: nicwu-cel <nicwu@celestica.com>
Port index 22 is associated with phy23_config.json, then same port index 22 in phy24_config.json may cause gearbox port creation error. Port Ethernet22 maps to index 23.
- Why I did it
SN5600 has an additional service interface with a different parameters than other interfaces.
- How I did it
Added the etp65 interface with the correct parameters.
- How to verify it
Run platform test on SN5600 platform.
Check the service port can startup correctly.
- Why I did it
New SKU for MSN-4700 Platform i.e. Mellanox-SN4700-C128
Requirements:
* Breakout: Port 1-32: 4x100G
* Downlinks: 120 (1-30)
* Uplinks: 8 (31-32)
* Shared Headroom: Enabled
* Over Subscribe Ratio: 1:8
* Default Topology: T2
* Default Cable Length for T2: 1500m
* QoS params: The default ones defined in qos_config.j2 will be applied
* Small Packet Percentage: Used 50% for traditional buffer model Note: For dynamic model, the value defined in LOSSLESS_TRAFFIC_PATTERN|AZURE|small_packet_percentage is used
Additional Details:
Switch Type has to be programmed as SpineRouter through config_db.json in DEVICE_METADATA|localhost|type field for the buffer values & cable lengths defined in the buffers_defaults_t2.j2 to apply on the device
Cable Lengths Used for generating buffer_defaults_{t0,t1,t2}.j2 values
Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>
- Why I did it
Add new sensor conf file to support respined platforms(SN3700/SN3700C/SN4600C)
- How I did it
Add new sensor conf
Update the get_sensors_conf_path scripts to apply the sensor conf according to the HW respin version info
- How to verify it
run platform test(including sensor test)
Signed-off-by: Kebo Liu <kebol@nvidia.com>
Why I did it:
To fix hlx platform sfp+ module tx disable issue
How I did it:
Fix sfp+ tx disable function according SFF-8472 specification
Co-authored-by: Eric Zhu <erzhu@celestica.com>
- Why I did it
Support Mellanox-SN4600C-C64 as T1 switch in dual-ToR scenario
This is to port #11032 and #11299 from 202012 to master.
Support additional queue and PG in buffer templates, including both traditional and dynamic model
Support mapping DSCP 2/6 to lossless traffic in the QoS template.
Add macros to generate additional lossless PG in the dynamic model
Adjust the order in which the generic/dedicated (with additional lossless queues) macros are checked and called to generate buffer tables in common template buffers_config.j2
Buffer tables are rendered via using macros.
Both generic and dedicated macros are defined on our platform. Currently, the generic one is called as long as it is defined, which causes the generic one always being called on our platform. To avoid it, the dedicated macrio is checked and called first and then the generic ones.
Support MAP_PFC_PRIORITY_TO_PRIORITY_GROUP on ports with additional lossless queues.
On Mellanox-SN4600C-C64, buffer configuration for t1 is calculated as:
40 * 100G downlink ports with 4 lossless PGs/queues, 1 lossy PG, and 3 lossy queues
16 * 100G uplink ports with 2 lossless PGs/queues, 1 lossy PG, and 5 lossy queues
Signed-off-by: Stephen Sun <stephens@nvidia.com>
* Why I did it
Followup to #10656. This change adds the remaining configs for the 720DT-48S platform.
* How I did it
Adds the following:
gearbox_config.json and other gearbox-related config files, to enable traffic on external PHY ports (Ethernet0-23)
sensors.conf
pcie.yaml
Also add missing facts in platform.json
* How to verify it
show interfaces status shows links up on interfaces Ethernet0-23
traffic flows with no errors on interfaces Ethernet0-23
Note: above testing depends on Add gbsyncd container for broncos #11154 and [orchagent]: Enhance initSaiPhyApi sonic-swss#2367, as well as having the appropriate PAI driver.
Co-authored-by: Samuel Angebault <staphylo@arista.com>
Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
Improve throughput and latency for 7260 deployments
How I did it
Update the dynamic threshold to 0 and ECN settings as 2mb/10mb/5%
How to verify it
Updated unit tests to use the modified values for 7260 ecn settings.
Why I did it
This was an ask by Microsoft to provide:
7260 config.bcm file for hardware sku Arista-7260CX3-D92C16 (Named Arista-7260CX3-D96C16).
There are 16 100G uplinks:
Ethernet13-20/1
Ethernet45-52/1
All other ports are breakout to 2 50G ports.
How I did it
Copied existing Arista-7260CX3-D108C8 HWSKU and altered the bcm.config and port_config.ini files.
How to verify it
The new 100G ports do come up with a 201811 image using this HWSKU.
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
* [device]: Add SAI checksum verify to TD3 config
* A new config option was added to control the value of IPV4_INCR_CHECKSUM_ORIGINAL_VALUE_VERIFY in the EGR_FLEX_CONFIG control register (this prevents checksums of 0xffff from being propagated to other devices)
For 7800 LCs, set LAG mode to support 1024 number of 16-member system
LAGs.
Why I did it
The SOC property changes are necessary to match #10519 which increases the number of system LAG IDs to 1024.
Description for the changelog
For 7800 LCs, set LAG mode to support 1024 number of 16-member system
LAGs.
Why I did it
This linecard runs in multi-asic mode and therefore needs the use_pcie_id_chassis file to work properly.
The default_sku file was also missing which would break the boot when no minigraph is provided.
Description for the changelog
Add missing default_sku and use_pci_id_chassis configs for 7800R3A-36D2
Signed-off-by: polly_hsu polly_hsu@edge-core.com
Why I did it
Update to support as7816-64x DPB (Dynamic Port Breakout)
How I did it
Download the SONiC master image with commit, 64dc08a dated 2022-04-05 from SONiC Image Azure Pipelines
Update the file change of this PR accordingly
How to verify it
Set the default t1 topology configuration
Configure to breakout Ethernet0 from "1x100G[40G]" to "4x25G"
$ sudo config interface breakout Ethernet0 "4x25G" -f
Check the SONiC DBP interface status is expected
$ show interfaces status
Why I did it
Support Intel Tofino based platforms Netberg Aurora 610
ASIC: Intel Tofino BFN-T10-032D-020
Pors: 48x 25G + 8x 100G
How I did it
Added specification to device/netberg directory
Added platform/barefoot/sonic-platform-modules-netberg contains kernel modules, scripts and sonic_platform packages.
Modified the platform/barefoot/one-image.mk and platform/barefoot/rule.mk to include Aurora 610 related ID and files.
How to verify it
Build SONiC
Install the image on the device and verify the related components are installed and shown correctly.
Why I did it
Add 6512-32r support for Wistron platform
Update sw-to3200k for newer branch
How I did it
Add code in device and platform folder for 6512-32r
Update sw-to3200k code both in device and platform folder
How to verify it
Install on Wistron device and run command to verify
Signed-off-by: RogerChang Roger_Chang@wistron.com
Added initial set of config files to allow for booting and partial traffic testing in SONiC on the 720DT-48S.
How to verify it
- Switch boots
- show interfaces status shows links up on interfaces Ethernet24-51
- Traffic flows with no errors on interfaces Ethernet24-51
Signed-off-by: bingwang <wang.bing@microsoft.com>
Why I did it
This PR brings two changes
Add lossy PG profile for PG2 and PG6 on T1 for ports between T1 and T2.
After PR Update qos config to clear queues for bounced back traffic #10176 , the DSCP_TO_TC_MAP and TC_TO_PG_MAP is updated when remapping is enable
DSCP_TO_TC_MAP
Before After Why do this change
"2" : "1" "2" : "2" Only change for leaf router to map DSCP 2 to TC 2 as TC 2 will be used for lossless TC
"6" : "1" "6" : "6" Only change for leaf router to map DSCP 6 to TC 6 as TC 6 will be used for lossless TC
TC_TO_PRIORITY_GROUP_MAP
Before After Why do this change
"2" : "0" "2" : "2" Only change for leaf router to map TC 2 to PG 2 as PG 2 will be used for lossless PG
"6" : "0" "6" : "6" Only change for leaf router to map TC 6 to PG 6 as PG 6 will be used for lossless PG
So, we have two new lossy PGs (2 and 6) for the T2 facing ports on T1, and two new lossless PGs (2 and 6) for the T0 facing port on T1.
However, there is no lossy PG profile for the T2 facing ports on T1. The lossless PGs for ports between T1 and T0 have been handled by buffermgrd .Therefore, We need to add lossy PG profiles for T2 facing ports on T1.
We don't have this issue on T0 because PG 2 and PG 6 are lossless PGs, and there is no lossy traffic mapped to PG 2 and PG 6
Map port level TC7 to PG0
Before the PCBB change, DSCP48 -> TC 6 -> PG 0.
After the PCBB change, DSCP48 -> TC 7 -> PG 7
Actually, we can map TC7 to PG0 to save a lossy PG.
How I did it
Update the qos and buffer template.
How to verify it
Verified by UT.