- Why I did it
The latest upgrade of Mellanox hw-mgmt V7.0020.1300 introduced a couple new kernel modules for new Mellanox platforms that have yet to be upstreamed to the linux kernel.
As these new platforms do not have SONiC support we elected not to upstream these new drivers to sonic-linux-kernel but hw-mgmt expects them to exist which is causing a non-functional error on switch boot.
Feb 15 00:09:55.374130 r-leopard-simx-74 ERR systemd-modules-load[269]: Failed to find module 'emc2305'
Feb 15 00:09:55.374141 r-leopard-simx-74 ERR systemd-modules-load[269]: Failed to find module 'ads1015'
To resolve this we can patch hw-mgmt to no longer attempt to load these modules by default.
- How I did it
Added a SONiC patch to Mellanox hw-mgmt in order to remove the unused kernel modules which were not upstreamed to sonic-linux-kernel
- How to verify it
Boot switch and verify there are no error logs regarding kernel modules failing to load.
- Why I did it
In SONiC thermal control algorithm, it compares thermal zone temperature with thermal zone threshold. Previously, a thermal zone with no thermal sensor can still get its threshold. However, a recently driver patch changes this behavior: a thermal zone with no thermal sensor will return 0 for threshold. We need to ignore such thermal zone.
- How I did it
Ignore thermal zones whose temperature is 0.
- How to verify it
Added unit test case and Manual test
- Why I did it
Update MFT to version 4.18.1-16 for bugs fixes and new SN2201 support
- How I did it
Advance to MFT tool version to 4.18.1-16
- How to verify it
Manually tested on all Mellanox platforms (ASIC FW Upgrade, link debug tools, CPLD upgrade, etc.)
- Why I did it
New version of mellanox platform management code available adding support for new platforms and fixing bugs.
- How I did it
1. Updated the submodule
2. Updated makefile version references
3. Regenerated SONiC patches
- Why I did it
Fix issue: 'sx_port_mapping_t' object has no attribute 'slot_id'. sx_port_mapping_t only has attribute slot.
- How I did it
Change slot_id to slot.
- How to verify it
Manual test
- Why I did it
Python select.select accept a optional timeout value in seconds, however, the value passes to it is a value in millisecond.
- How I did it
Transfer the value to millisecond.
- How to verify it
Manual test
- Why I did it
To include latest SDK fixes:
1. On CMIS modules, after low power configuration, the firmware waited for the module state to be ModuleReady instead of ModuleLowPower causing delays.
2. When connecting SN4600C, 100GbE port with CWDM4 module (Gen 3.0), link up time is 30 seconds.
and to include SAI fixes \ changes:
1. Reduce verbosity for resource check vendor data not found
2. Fix metadata validation, check default value on conditions check
3. Add 100MB, 10MB to 2201 system
4. L3 VXLAN overlay ECMP
5. VXLAN srcport API implementation
6. Fix scheduler profile null (default values) when set on sub group scheduler group
7. Fix ACL binding restoration when port leaves a LAG
8. Fix route logic for set next hop/action and reference counter for ECMP overlay
- How I did it
1. Updated SDK/FW submodule and relevant makefiles with the required versions.
2. Update SAI submodule and relevant makefile with the required version.
- How to verify it
Build an image and run tests from "sonic-mgmt".
Why I did it
Requirements from Microsoft for fwutil update all state that all firmwares which support this upgrade flow must support upgrade within a single boot cycle. This conflicted with a number of Mellanox upgrade flows which have been revised to safely meet this requirement.
How I did it
Added --no-power-cycle flags to SSD and ONIE firmware scripts
Modified Platform API to call firmware upgrade flows with this new flag during fwutil update all
Added a script to our reboot plugin to handle installing firmwares in the correct order with prior to reboot
How to verify it
Populate platform_components.json with firmware for CPLD / BIOS / ONIE / SSD
Execute fwutil update all fw --boot cold
CPLD will burn / ONIE and BIOS images will stage / SSD will schedule for reboot
Reboot the switch
SSD will install / CPLD will refresh / switch will power cycle into ONIE
ONIE installer will upgrade ONIE and BIOS / switch will reboot back into SONiC
In SONiC run fwutil show status to check that all firmware upgrades were successful
- Why I did it
Optimize thermal control policies to simplify the logic and add more protection code in policies to make sure it works even if kernel algorithm does not work.
- How I did it
Reduce unused thermal policies
Add timely ASIC temperature check in thermal policy to make sure ASIC temperature and fan speed is coordinated
Minimum allowed fan speed now is calculated by max of the expected fan speed among all policies
Move some logic from fan.py to thermal.py to make it more readable
- How to verify it
1. Manual test
2. Regression
Why I did it
Recently additional sensors that were needed only for specific system added to all systems and caused errors.
How I did it
* Include CPU board and switch board sensors only on SN2201 system
* Fix issue in test_chassis_thermal, now it skips non existing thermals.
How to verify it
Run show platform temperature
Signed-off-by: liora <liora@nvidia.com>
- Why I did it
Added missing functionality for dynamic buffer calculation in Spectrum-4.
- How I did it
Added a section of code in asic_table.j2 for Spectrum-4, and added the simx version of SN5600 to the supported list.
- How to verify it
Manually: buffershow -l should show all ingress/egress lossy/lossless pools, and all fields of profiles should show values.
Automatically: https://github.com/Azure/sonic-mgmt/blob/master/tests/qos/test_buffer.py
Signed-off-by: Raphael Tryster <raphaelt@nvidia.com>
- Why I did it
To fix an issue that hw-mgmt patches were not applied. One patch was already in upstream hw-mgmt package thus applying it again caused an error and no other patches were applied. Also, I did it to improve the Makefile, so that the make will fail in case patches fail to apply.
- How I did it
Removed obsolete patch, made applying patches a hard failure in the build.
- How to verify it
Run the make and verify patches are applied.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
- Why I did it
Rename platform x86_64-mlnx_msn4800 to x86_64-nvidia_msn4800
- How I did it
Rename platform folder as well as all code that reference the platform name
- How to verify it
Manual test
- Why I did it
To have an ability to use PRM sniffer.
- How I did it
Enabled the option in configure flags.
- How to verify it
Built and ran on switch. Enabled the feature in runtime and checked the sniffer recording.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
The same docker image is built multiple times after upgrading to bullseye, the build time is increased to about 15 hours from 6 hours.
See log: https://dev.azure.com/mssonic/be1b070f-be15-4154-aade-b1d3bfb17054/_apis/build/builds/50390/logs/9
Line 1437: 2021-11-11T11:15:02.7094923Z [ building ] [ target/docker-sonic-telemetry.gz ]
Line 1446: 2021-11-11T11:37:41.1073304Z [ finished ] [ target/docker-sonic-telemetry.gz ]
Line 1459: 2021-11-11T11:38:20.6293007Z [ building ] [ target/docker-sonic-telemetry.gz-load ]
Line 1462: 2021-11-11T11:38:28.1250201Z [ finished ] [ target/docker-sonic-telemetry.gz-load ]
Line 2906: 2021-11-11T18:57:42.8207365Z [ building ] [ target/docker-sonic-telemetry.gz ]
Line 2917: 2021-11-11T19:43:47.1860961Z [ finished ] [ target/docker-sonic-telemetry.gz ]
Line 3997: 2021-11-11T22:49:35.0196252Z [ building ] [ target/docker-sonic-telemetry.gz ]
Line 4002: 2021-11-11T23:14:00.4127728Z [ finished ] [ target/docker-sonic-telemetry.gz ]
How I did it
Place the python wheels in another folder relative to the build distribution.
Co-authored-by: Ubuntu <xumia@xumia-vm1.jqzc3g5pdlluxln0vevsg3s20h.xx.internal.cloudapp.net>
- Why I did it
Add new Spectrum-4 system support SN5600 on top of Nvidia ASIC simulator.
- How I did it
Add all relevant system and simulator SKU.
Updated syseeprom.hex and related directories to reflect Nvidia SN5600 brand name.
- How to verify it
Tested init flow, basic show commands, up interfaces, traffic test.
Signed-off-by: Raphael Tryster <raphaelt@nvidia.com>
- Why I did it
To include latest fixes.
SAI
1. Reclaim buffers for port which is admin down
2. Support for Spectrum-4 os Nvidia ASIC simulation
3. Support for SN2201
4. Fix host interface table entry, one channel per trap (fix sflow double registration)
5. 2 new queue counters - ecn marked packets + shared current occupancy
6. Fix storm policer unknown unicast
7. Add key/value for accuflow counters
8. Add MAC move
9. Add mirror congestion mode attribute
SDK
1. Under various circumstances, Ethernet ports falsely showed that InfiniBand cables were connected.
2. In SN4600C, at times, the link up time in both DAC and optics cables may, in the worst case, take up to 15 seconds.
3. Using SN4600C with copper or optics loopback cables in NRZ speeds, link may raise in long link up times
4. When ECMP has high amount of next-hops based on VLAN interfaces, in some rare cases, packets will get a wrong VLAN tag and will be dropped.
5. When connecting Spectrum devices with optical transceivers that support RXLOS, remote side port down might cause the switch firmware to get stuck and cause unexpected switch behavior.
6. Aggregation event is missing for WJH L2 drop reason 'Unicast egress port list is empty'.
7. Tying the SCL and SDA of the optical modules to 3.3V causes errors.
8. On SN4600, there was a delay of more than 10 seconds from the time a data packet is sent from CPU until it is transmitted through one of the switch ports.
9. While using SN4600C system with Finisar FTLC1157RGPL 100GbE CWDM4 modules, intermittent link flaps across multiple ports may be observed.
10. In Spectrum-2 and Spectrum-3 systems, link did not work in auto-negotiation when connected to Marvell PHY. KR mechanism has been enhanced to integrate with Marvell PHY.
11. The tunnel counter counts the drop packets now for Spectrum-2 and Spectrum-3 and consistent with Spectrum behavior and count the ECN dropped packets as well.
12. When connecting SN3800 to Cisco-9000, fast-linkup flow will fail and will rise in the normal flow.
13. Race condition in WJH library: when multiple threads load the LAG shared memory concurrently, the program may crash.
14. Add WJH L2 drop reason 'Unicast egress port list is empty' as a new drop reason.
15. Fixed a memory leak in sx_api_port_sflow_statistics_get API.
16. During initialization flow, the command interface that is used by the minimal driver and SDK caused the collision in the firmware since the same buffer is used in the firmware for the two interfaces.
17. Fix route issue on Kernel 5.10
- How I did it
Updated SDK/SAI submodule and relevant makefiles with the required versions.
- How to verify it
Build an image and run tests from "sonic-mgmt".
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
Why I did it
Nvidia platform API does not support set LED to orange
How I did it
Allow user to set LED to orange
How to verify it
Added unit test
Manual test
- Why I did it
Add support for SN2201 platform
- How I did it
Add required content for SN2201 platform
Note: still missing kernel driver support for this system. Once all is upstream will be updated as well.
- How to verify it
Install and basic sanity tests including traffic.
Signed-off-by: liora liora@nvidia.com
Depends on #9358
Why I did it
Adjust LED logical according to hw-mgmt change.
How I did it
Add a trigger to set LED to blink.
How to verify it
Manual test
#### Why I did it
Updated hw-mgmt pointer to updated branch and to include new bugfixes. The hw-mgmt submodule was previously pointing to an orphaned commit which could not be fetched from github, this has now been resolved.
#### How I did it
Updated submodule pointer.
#### How to verify it
Clone down repository and update all submodules.
Signed-off-by: Stephen Sun stephens@nvidia.com
Why I did it
Support zero buffer profiles
Add buffer profiles and pool definition for zero buffer profiles
Support applying zero profiles on INACTIVE PORTS
Enable dynamic buffer manager to load zero pools and profiles from a JSON file
Dependency: It depends on Azure/sonic-swss#1910 and submodule advancing PR once the former merged.
How I did it
Add buffer profiles and pool definition for zero buffer profiles
If the buffer model is static:
Apply normal buffer profiles to admin-up ports
Apply zero buffer profiles to admin-down ports
If the buffer model is dynamic:
Apply normal buffer profiles to all ports
buffer manager will take care when a port is shut down
Update buffers_config.j2 to support INACTIVE PORTS by extending the existing macros to generate the various buffer objects, including PGs, queues, ingress/egress profile lists
Originally, all the macros to generate the above buffer objects took active ports only as an argument
Now that buffer items need to be generated on inactive ports as well, an extra argument representing the inactive ports need to be added
To be backward compatible, a new series of macros are introduced to take both active and inactive ports as arguments
The original version (with active ports only) will be checked first. If it is not defined, then the extended version will be called
Only vendors who support zero profiles need to change their buffer templates
Enable buffer manager to load zero pools and profiles from a JSON file:
The JSON file is provided on a per-platform basis
It is copied from platform/<vendor> folder to /usr/share/sonic/temlates folder in compiling time and rendered when the swss container is being created.
To make code clean and reduce redundant code, extract common macros from buffer_defaults_t{0,1}.j2 of all SKUs to two common files:
One in Mellanox-SN2700-D48C8 for single ingress pool mode
The other in ACS-MSN2700 for double ingress pool mode
Those files of all other SKUs will be symbol link to the above files
Update sonic-cfggen test accordingly:
Adjust example output file of JSON template for unit test
Add unit test in for Mellanox's new buffer templates.
How to verify it
Regression test.
Unit test in sonic-cfggen
Run regression test and manually test.
- Why I did it
When PSU is powered off, the PSU is still on the switch and the air flow is still the same. In this case, it is not necessary to set FAN speed to 100%.
- How I did it
When PSU is powered of, don't treat it as absent.
- How to verify it
Adjust existing unit test case
Add new case in sonic-mgmt
- Why I did it
Support PSU voltage high/low thresholds and power max threshold
1. Add thresholds support for voltage and power.
2. As thresholds are not supported on all platforms, we need to check the capability first and fetch thresholds only if it is supported.
- How I did it
- How to verify it
Run regression test and manual test.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
#### Why I did it
Mellanox builds were failing intermittently due to the `issue_version` file and MFT package not building correctly in the Azure pipeline environment (both of these packages were patched to build correctly with bullseye running on the host and buster running on the dockers)
#### How I did it
Fixed two problems:
1. BLDENV is not passed to the Makefiles so the references to this were replaced with correct logic
2. `issue_version` was not defined as a target for bullseye and as such was not cached. Altered the build such that it is defined as a target for bullseye (in the case of buster it builds the file, in the case of bullseye it copies from buster)
The previous PR fixing this was reverted as it is no longer necessary for a passing build and was not a long-term fix. https://github.com/Azure/sonic-buildimage/pull/9235
#### How to verify it
Build on AZP and verify success.
The issu-version file for Mellanox is generated from the Mellanox SDK
libraries. The SDK is installed into a Buster docker container, but the
issu-version file goes onto the base OS, which is Bullseye. To work
around this, the issu-version build rules explicitly copies the
issu-version file to target/files/bullseye/ during the Buster build.
Because of our build infra, if caching is enabled and a cache is being
used, then for issu-version, since it is technically built as part of
Buster, then only target/files/buster/issu-version is saved into the
cache, and target/files/bullseye/issu-version isn't cached. If this
cache gets used, then target/files/bullseye/issu-version is missing, and
the final image build fails.
This is to work around the current build issue where Mellanox builds are
failing. This is so that issu-version is always "built", so that copy is
made into the bullseye directory.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
* Make neccesary changed to mellanox platform code to build on Debian 11
* Revert use of backported kernel to build mft and elect to only build kernel module under bullseye
Allow mellanox platform to build and successfully switch packets in
Debian 11
Upgraded
* Mellanox SDK
* Mellanox Hardware Management
* Mellanox Firmware
* Mellanox Kernel Patches
Adjusted build system to support host system running bullseye and
dockers running buster.
ISSU will likely be broken. As of right now, the issu-version file is
not being generated during build.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
- Why I did it
In case an app.ext requires a dependency syncd^1.0.0, the RPC version of syncd will not satisfy this constraint, since 1.0.0-rpc < 1.0.0. This is not correct to put 'rpc' as a prerelease identifier. Instead put 'rpc' as build metadata in the version: 1.0.0+rpc which satisfies the constraint ^1.0.0.
- How I did it
Changed the way how to version in RPC and DBG images are constructed.
- How to verify it
Install app.ext with syncd^1.0.0 dependency on a switch with RPC syncd docker.
Signed-off-by: Stepan Blyshchak <stepanb@nvidia.com>
- Why I did it
* To support systems with dynamic port configuration
* Apply lazy initialization to faster the speed of loading platform API
- How I did it
* Add module.py to implement dynamic port configuration (aka line card model)
* Adjust chassis.py, platform.py, thermal.py, sfp.py to support dynamic port configuration
* Optimize existing code
- How to verify it
Platform regression on MSN4700, MSN3800 and MSN2700, 100% pass
Unit test covers all new changes.
- Why I did it
Bug fix:
bad_param request due to missing parser rest command while running mlxlink
- How I did it
Advance to MFT tool version to 4.17.2-12.
- How to verify it
Manually tested on all mellanox platforms.
- Why I did it
Add NVIDIA Copyright header to "mellanox" files
- How I did it
Add NVIDIA Copyright header as a comment for Mellanox files
- How to verify it
Sanity tests and PR checkers.
Why I did it
Currently the mellanox platform API is validating the file extensions of firmware packages to be installed for basic sanity checking. However, ONIE packages do not have an extension and as such if there is a "." in the name it is taken to be an extension and then fails the sanity check.
How I did it
I removed the check which ensures that ONIE images don't have a file extension.
How to verify it
Name the ONIE updater file 2021.onie and attempt to install it via fwutil install fw 2021.onie --yes
Why I did it
The fwutil update all utility expects the auto_update_firmware method in the Platform API to execute the update_firmware() call and not the install_firmware() call.
How I did it
Changed the method in the mellanox platform API component implementation.
How to verify it
Run fwutil update all with a CPLD update on a Mellanox platform and verify that it properly updates the firmware using the MPFA file.
- Why I did it
Advance to new Nvidia SAI release with the following changes:
New features:
- Align with new SDK/FW version 4.5.1006 and above and in parallel to existing used SDK/FW bundle
- Implement timestamp and egress_queue_index hostif packet attributes.
Bugs fixes:
- Fix compilation issues with gcc10
- Fix return code for buffer overflow for query enum values and query statistics capabilities
- Reduce verbosity of print in case packet ingress on invalid port
- Fix mirror Qos settings
- How I did it
Updated SAI version and submodule pointer
- How to verify it
Run regression tests from sonic-mgmt
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
- Why I did it
Change thermal recover threshold from temp_trip_norm to temp_trip_high, so that thermal algorithm would set fan speed to minimum allowed earlier and save power.
- How I did it
Change thermal recover threshold from temp_trip_norm to temp_trip_high
- How to verify it
Manual test
- Why I did it
Advance to Mellanox SAI ver 1.19.2 to pick up dynamic Policy Based Hashing support.
For this version above the static Policy Based Hashing is no longer supported.
For detailed release notes check https://github.com/Mellanox/SAI-Implementation/blob/sonic2111/release%20notes.txt
- How I did it
Updated SAI-Implementation submodule
- How to verify it
1. make configure PLATFORM=mellanox
2. make target/sonic-mellanox.bin
Run full regression as well as new dynamic PBH tests
Signed-off-by: Nazarii Hnydyn <nazariig@nvidia.com>
#### Why I did it
New PSU could install different type of fan, so fan max/min speed should be read per PSU
#### How I did it
The existing implementation read PSU max/min fan speed from a common file, change it to read from per PSU file
#### How to verify it
Manual test
- Why I did it
Update SDK\FW version to 4.4.3326\2008.3326. This version contains:
New Features:
1. Add support for Fast Boot for SN3800
Bug Fixing:
1. In some cases, when the total number of allocations exceeds the resource limit, an error can occur due to incorrect resource release procedure. This issue is most likely to affect the following resources: flow counters, ACL actions, PBS, WJH filter, Tunnels, ECMP containers, MC (L2 &L3)
2. On Spectrum systems, when using Async Router API with IPV6, an error message in the log regarding failing to remove ECMP container may show up. This error is not functional and can be safely ignored.
3. On Spectrum-2 systems and above, when using warm boot, setting max_bridge_num to a value greater than 1968 will cause an error and potential crash.
4. Some Molex cables do not support speed after reboot
- How I did it
- How to verify it
Was verified by running regression tests that includes complete sonic-mgmt tests supported
- Why I did it
New release of MFT has the following changelog / RN
Fixed an issue that resulted in getting MVPD read errors from the mlxfwmanager during fast reboot.
Fixed mlxuptime sometimes generating a time less than previous due the wrong frequency calculation
- How I did it
Update makefile pointer to new version.
- How to verify it
Manually tested on all Mellanox platforms.
Update SDK\FW version to 4.4.3320\2008.3324. This version contains:
New Features:
* Add support for Fast Boot for SN3800
Bug Fixing:
* In some cases, when the total number of allocations exceeds the resource limit, an error can occur due to incorrect resource release procedure. This issue is most likely to affect the following resources: flow counters, ACL actions, PBS, WJH filter, Tunnels, ECMP containers, MC (L2 &L3)
* On Spectrum systems, when using Async Router API with IPV6, an error message in the log regarding failing to remove ECMP container may show up. This error is not functional and can be safely ignored.
* On Spectrum-2 systems and above, when using warm boot, setting max_bridge_num to a value greater than 1968 will cause an error and potential crash.
* Some Molex cables do not support speed after reboot
Signed-off-by: Dror Prital <drorp@nvidia.com>
The start template script that this value is used in will determine what
network namespace to use, and will add --net=host if it needs to run in
the host namespace.
With Docker 20.10, if --net=host is specified twice in docker run, then
it errors out. Therefore, remove the explicit --net=host in the run
options setting and let the start template script specify it.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
Why I did it
BIOS upgrade on rare cases cannot guarantee bus value remain the same on every BIOS release. Ignoring this field in order for pcied not to fail but still verify device id in a different way. The solution is future proof and will not require changes in code when new BIOS version is available
How I did it
Since bus is not a fixed value (it is determined by the bios version) we are ignoring this field, and instead checking if there is a device that match on all other fields that and in addition has a matching device id.
How to verify it
Verify no errors or failures in pcied on different BIOS version with the same code base.
- Why I did it
Update SAI version to 1.19.1. The following was changed:
1. Update license
2. Do not remove and re-apply the same SDK mirror session on LAG
3. FEC fix to support all speeds
4. Improve PG counters performance
5. Fix number of switch priorities for port mirroring
Signed-off-by: Dror Prital <drorp@nvidia.com>
Avoid initializing sfp/thermal/components/fan/psu/leds on simx and create vpd_info file on hw_management when we use mellanox simulator platform
- Why I did it
this is a fix for issue in mellanox simulator platforms. the syseepromd failed on the pmon docker. also "decode-syseeprom" failed also
- How I did it
before initializing thermal/components/fan/psu/leds --> check if we are running on simx
creating the vpd_info on the hw_management folder.
- How to verify it
check if syseepromd process was loaded properly on the pmon docker.
decode-syseeprom is working well without errors/warnings
- Why I did it
to prevent python exception error when executing warm-reboot command on mellanox simulator platform
- How I did it
return None on the watchdog python script on cases that watchdog file is not exist
- How to verify it
warm-reboot is running well without the python error. error message will appear on log on these cases.
in order to avoid this error message we can simulate the watchdog on mellanox simulator platform
Update FW version to 2008.3218, fixing the following issues:
- 50G/100G links that are operationally down before warm-reboot are not coming up after warm-reboot
- 50G/100G links with admin shut / no shut commands are not coming up after warm-reboot
Signed-off-by: Dror Prital <drorp@nvidia.com>
- Why I did it
* For SAI - Advance to adopt the following fixes:
1. Better handle not implement object type for resource availability
2. Fix ext dump when saidump is triggered from 2nd process (saidump utility) other than main adapter host (syncd in SONiC)
* For SDK\FW:
- Changes and new features:
1. Added support in SN4600C systems for new module Finisar ET7402-CWDM4 (100G CWDM4 QSFP28 1310nm SM 2KM).
2. Added support for new module MMS1W50-HM (2km transceiver FR4) for 200GbE
3. Improved performance of "per-port-buffer" counters
4. Added support for Kernel 5.10
- Bugs fixes:
On rare occasions (0.5%), in SN4600C systems, when using 100GbE NRZ mode and Fastboot flow, the link up time may take up to 10 seconds
Signed-off-by: Dror Prital <drorp@nvidia.com>
#### Why I did it
Currently, SONiC use a single value to represent SFP error, however, multiple SFP errors could exist at the same time. This PR is aimed to support it
#### How I did it
Return bitmap instead of single value when a SFP event occurs
Signed-off-by: Stephen Sun <stephens@nvidia.com>
Split and bulk counter bug fixes:
- Init port auto neg to default on static (SAI XML) port split for 2nd+ port
- Fix port stats SAI_PORT_STAT_WRED_DROPPED_PACKETS, SAI_PORT_STAT_ECN_MARKED_PACKETS, SAI_PORT_STAT_ETHER_TX_OVERSIZE_PKTS
- Hide error message when reading not implemented port stat
Signed-off-by: Shlomi Bitton <shlomibi@nvidia.com>
- Why I did it
The methods get_model, get_serial, and get_revision have been implemented by reading relevant information from VPD and then recording the information into relevant fields.
However, there is no VPD data on platforms with fixed PSUs and relevant fields haven't been initialized, which causes the methods to throw exceptions. which in turn prevents psud from inserting fields into PSU table.
Eventually, this causes show platform psustatus doesn't output correct info.
- How I did it
Initialize those fields as N/A on systems with fixed PSUs.
- How to verify it
Manually test.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
- Why I did it
Remove EEPROM cache file and use DB instead
- How I did it
Read EEPROM data from DB if possible
If data is not ready in DB, read from hardware using a visitor pattern
- How to verify it
Manual test and regression
Why I did it
The Mellanox platform is required to support the fwutil auto-update feature defined here
This is to allow switches, when performing SONiC upgrades to choose whether to perform firmware upgrades that may interrupt the data plane through a cold boot.
How I did it
Two methods were added to the component implementations for mellanox.
In the base Component class we add a default function that chooses to skip the installation of any firmware unless the cold boot option is provided. This is because the Mellanox platform, by default, does not support installing firmware on ONIE, the CPLD, or the BIOS "on-the-fly".
In the ComponentSSD class we add a function that behaves similarly but uses the Mellanox specific SSD firmware upgrade tool to check if the current SSD supports being upgraded on the fly in order to decide whether to skip or perform the installation.
How to verify it
Unit tests are included with this PR. These test will run on build of target sonic-mellanox.bin
You may also perform fwutil auto-update ... commands after Azure/sonic-utilities#1242 is merged in.
- Why I did it
Enhance the Python3 support for platform API. Originally, some platform APIs call SDK API which didn't support Python 3. Now the Python 3 APIs have been supported in SDK 4.4.3XXX, Python3 is completely supported by platform API
- How I did it
Start all platform daemons from python3
1. Remove #/usr/bin/env python at the beginning of each platform API file as the platform API won't be started as daemons but be imported from other daemons.
2. Adjust SDK API calls accordingly
- How to verify it
Manually test and run regression platform test
Signed-off-by: Stephen Sun <stephens@nvidia.com>
- Why I did it
Adjust the Makefile for SDK/python-SDK-API to support both python2 and python3
- How to verify it
Build the image and check whether python2 and python3 are both supported by SDK API.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
Why I did it
* For SAI - Upgrade to Version 1.19.0
- Add support for VxLAN encap TTL uniform model on SPC2/3
- Add ACL entry actions set VRF, set do no learn, add VLAN ID, add VLAN priority
- Add ACL field has VLAN tag
- Bulk counters (improve port statistics performance)
- Create async dump extra as part of debug generate dump
- Create irisc dump on severe health event
- Support 0 port systems (modify get switch mac to work accordingly)
- Set interface vlan up state for ping tool in SONiC
- Support attributes SAI_PORT_ATTR_QOS_SCHEDULER_PROFILE_ID, SAI_PORT_ATTR_QOS_INGRESS_BUFFER_PROFILE_LIST,
SAI_PORT_ATTR_QOS_EGRESS_BUFFER_PROFILE_LIST, SAI_PORT_ATTR_POLICER_ID as part of port create Git stats
* For SDK\FW - Upgrade to Version SDK 4.4.3106, FW 2008_3110
Added Features:
- Increased ACL table
- Enhanced PSAMPLE support
- Added support for Finisar SR4 module in SN3700 systems
- Added support for Python 3.0 in examples.
Fix bugs:
- On LR4 transceivers 00YD278, the firmware incorrectly identified the transceiver
- Reduce memory consumption for virtual LAG
- Fixed PSAMPLE listeners cleanup on SDK drivers unloading.
- On Spectrum-2 and Spectrum-3 systems, slow reaction time to Rx pause packets may lead to buffer overflow on servers.
- BER may be experienced when using 5m DAC cables between SN4700 and SN2700 in 100GbE speed.
- On very rare occasion, when connecting DR4 PAM4 transceiver to 100GbE DR1 NRZ, low BER may be experienced.
- Unexpected packet drops on the port ingress buffer may be experienced when working in 400GbE mode.
Note: When performing ISSU from an older version, this fix won't be applied. For fix to apply, a non-ISSU reset is required.
- Fix SN3800 specific warm boot scenario: Disable interface, Warm Boot, Enable Interface --> link will remain down.
Signed-off-by: Dror Prital <drorp@nvidia.com>
This is due to the fact that we use SONIC_OVERRIDE_BUILD_VARS internally
in our build jobs and this is not accounted in caching framework.
So we add MLNX_SDK_DEB_VERSION to force rebuild if we changed it via
SONIC_OVERRIDE_BUILD_VARS.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
Signed-off-by: Yong Zhao yozhao@microsoft.com
Why I did it
Currently we leveraged the Supervisor to monitor the running status of critical processes in each container and it is more reliable and flexible than doing the monitoring by Monit. So we removed the functionality of monitoring the critical processes by Monit.
How I did it
I removed the script process_checker and corresponding Monit configuration entries of critical processes.
How to verify it
I verified this on the device str-7260cx3-acs-1.
- Why I did it
Pick up fix from new hw-management package:
Fix gearbox thermal zone name, which was lack suffix thermal zone number
- How I did it
Update the hw-management version number in the make file
Update hw-management submodule pointer
- How to verify it
Run platform related test cases on Mellanox platform
#### Why I did it
According to thermalctld hld, each fan must belong to a fan drawer, if the fan drawer does not physically exist, put fan into a virtual fan drawer. This PR is to clear fan from chassis._fan_list
#### How I did it
1. Don't put fan to chassis._fan_list
2. Always query fan from fan_drawer
#### Why I did it
This pull request allows calls to be made through the platform 2.0 API that retrieve the PSU and Chassis hardware revision on Mellanox platforms. Access to these values will aid customers in determining their hardware revisions for debugging and technical support. These values are intended to be eventually exposed through the CLI.
#### How I did it
For the PSU hardware revision I used the existing VPD function calls implemented in https://github.com/Azure/sonic-buildimage/pull/7382
For the Chassis hardware revision I parsed the SMBIOS / DMI type 2 information to retrieve the information.
Originally, SFP modules were always accessed from platform daemons, and arbitrary SFP modules can be accessed in the daemon. So all SFP modules were initialized in one shot once one of the following chassis APIs called
- get_all_sfps
- get_sfp_numbers
- get_sfp
Recently, we noticed that SFP modules can also be accessed from CLI, eg. the latest refactor of `sfputil`.
In this case, only one SFP module is accessed in the chassis object's life cycle.
To initialize all SFP modules in one shot is waste of time and causes the CLI to take much more time to finish.
So we would like to optimize the initialization flow by introducing a two-phase initialization approach:
- Partial initialization, which means the `chassis._sfp_list` has been initialized with proper length and all elements being `None`
- Full initialization, which means all elements in `chassis._sfp_list` are created
If the relevant function is called,
- `get_sfp`, only partial initialization will be done, and then the specific SFP module is initialized.
- `get_all_sfps` or `get_num_sfps`, full initialization will be done, which means all SFP modules are initialized.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
- Why I did it
Updated FW to xx.2008.2526 version.
Fixed issues:
1. Spectrum-2, Spectrum-3 | sFlow | High CPU load and high on fully loaded switch.
2. Spectrum-2, Spectrum-3 | Fine grain LAG | in rare cases doesn’t update the right entry
- How I did it
Updated submodule pointer and version in a Makefile.
- How to verify it
Full regression and bugs validation
Signed-off-by: Shlomi Bitton <shlomibi@nvidia.com>
#### Why I did it
We want to add the ability for the command `show platform psustatus` to show the serial number and part number of the PSU devices on Mellanox platforms. This will be useful for data-center management of field replaceable units (FRUs) on switches.
#### How I did it
I implemented the platform 2.0 functions `get_model()` and `get_serial()` for the PSU in the mellanox platform API by referencing the sysfs nodes provided by the [hw-management](https://github.com/Azure/sonic-buildimage/tree/master/platform/mellanox/hw-management) module.
#### Why I did it
Adopt a single way to get fan direction for all ASIC types.
It depends on hw-mgmt V.7.0010.2000.2303. Depends on https://github.com/Azure/sonic-buildimage/pull/7419
#### How I did it
Originally, the get_direction was implemented by fetching and parsing `/var/run/hw-management/system/fan_dir` on the Spectrum-2 and the Spectrum-3 systems. It isn't supported on the Spectrum system.
Now, it is implemented by fetching `/var/run/hw-management/thermal/fanX_dir` for all the platforms.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
The following error message is observed during chassis object being destroyed
"Exception ignored in: <function Chassis.__del__ at 0x7fd22165cd08>
Traceback (most recent call last):
File "/usr/local/lib/python3.7/dist-packages/sonic_platform/chassis.py", line 83, in __del__
ImportError: sys.meta_path is None, Python is likely shutting down
The chassis tries to import deinitialize_sdk_handle during being destroyed for the purpose of releasing the sdk_handle.
However, importing another module during shutting down can cause the error because some of the fundamental infrastructures are no longer available."
This error occurs when a chassis object is created and then destroyed in the Python shell.
- How I did it
To fix it, record the deinitialize_sdk_handle in the chassis object when sdk_handle is being initialized and call the deinitialize handler when the chassis object is being destroyed
- How to verify it
Manually test.
- Why I did it
Upgrade hw-mgmt to 7.0100.2303
Bug fixes
1. Fan direction feature fix for fixed FAN system (using shell instead of binutils/strings)
2. Remove cpld 4th link on systems with only 3 CPLD's
3. hw-mgmt: thermal: Add hardcoded critical trip point. Follow-up after patch "Removing critical thermal zones to prevent unexpected software system shutdown".
4. Fix sensor attribute mapping to be label based instead of index based to allow common handling of voltage regulator names independently of hardware changes.
5. Update 'lm-sensors' custom configuration file. Relevant only for users utilizing sensors.conf files coming along with hw-management package.
6. For full feature list please follow https://github.com/Mellanox/hw-mgmt/blob/V.7.0010.2300_BR/debian/Release.txt
- How I did it
Update hw-mgmt pointer
Remove unused patches
Fix existing patch to make sure it apply successfully
- How to verify it
Full platform regression on all mellanox platforms
Changes in the new release:
Fix 10G and 50G speeds in SAI XML to support all interface types
Enable SMAC=DMAC and SMAC MC in tunnel debug counter
Add tunnel statistics
Add isolation group API implementation
Fix ACL ANY debug counter to correctly track ACL drops
Add VXLAN source port hard coded range, controlled by K/V
FW dump me now feature
Add mlxtrace to saidump
Speed lane setting and AN control
Implement query stats API
VNI miss part of tunnel decal drop reason
Align with SAI API v1.8.1
Signed-off-by: Dror Prital <drorp@nvidia.com>
Signed-off-by: Stepan Blyschak stepanb@nvidia.com
This PR is part of SONiC Application Extension
Depends on #5938
- Why I did it
To provide an infrastructure change in order to support SONiC Application Extension feature.
- How I did it
Label every installable SONiC Docker with a minimal required manifest and auto-generate packages.json file based on
installed SONiC images.
- How to verify it
Build an image, execute the following command:
admin@sonic:~$ docker inspect docker-snmp:1.0.0 | jq '.[0].Config.Labels["com.azure.sonic.manifest"]' -r | jq
Cat /var/lib/sonic-package-manager/packages.json file to verify all dockers are listed there.
New features and fixes in the new SDK/FW:
SN4600C | AN/LT support
SN2700 | AN/LT bugs fixes
WJH | FID_MISS support
Signed-off-by: Kebo Liu <kebol@nvidia.com>
- Why I did it
Add missed files for dynamic buffer calculation for ACS-MSN3420 and ACS-MSN4410
- How I did it
asic_table.j2: Add mapping from platform to ASIC
Add buffer_dynamic.json.j2 for ACS-MSN4410.
- How to verify it
Check whether the dynamic buffer calculation daemon starts successfully.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
Integrate hw-management package V.7.0010.2002
Bug fixes:
Removing critical thermal zones to prevent unexpected software system shutdown:
*Kernel 4.9 -0071-mlxsw-core-Remove-critical-trip-point-from-thermal-z.patch
*Kernel 4.19 -076-mlxsw-core-Remove-critical-trip-point-from-thermal-z.patch
Removing redundant link for cpld3 for fixed systems (SN2100, SN2010).
Fix an issue with missed attribute for cpld3 (port CPLD) for SN2700, SN2410.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
Fix the following issues:
Spectrum-2, Spectrum-3 | Port | Fix link issue when using 25 GbE rate between two ports while one is on Spectrum-2-based system and the other is on Spectrum-3-based system
All | warmboot | fail to upgrade from earlier SONiC versions with official SDK/FW 4.4.2306 (was on SONiC 201911)
All | What-Just-Happened | When enabling or disabling WJH under high traffic load to the host CPU, in very specific and low probability conditions, an error could occur, that may result in loss of data, channel failure or in extreme cases SW failure
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
- Why I did it
The existing Fan led and Psu led object initialize itself to green color in init method. However, there are multiple daemons calls sonic platform API and there could be a case that:
A PSU is removed from system
Reboot switch
psud detects that 1 PSU is missing and set PSU led to red
Other daemon just start up and call sonic platform API, the API set PSU led to green by call PsuLed.init
This PR is a partial fix for the issue. As we also need guarantee that the led is initialized with a correct value. I checked existing psud and thermalctld code. psud always initialize the PSU led color on boot up, thermalcltd need some changes to initialize led color on the first run
- How I did it
Remove the led color initialization code from FanLed.init and PsuLed.init
- How to verify it
Manual test
There was a change to replace platform utils with sonic platform API in psuutil. However, psu API is not initialized on host side. The PR is to fix it.
- Why I did it
To pick up new features and fix from SDK/FW and SAI
SDK/FW new Feature:
All | Added support for multiple modules and cable types. For full list contact Nvidia networking support
Spectrum-3 | SN46000C | Added support for up to 5W on ports 49 to 64 .
SDK/FW bugs' fix:
All | fast reboot | fast boot failure from latest 201811 to 201911 and above
Spectrum | 10GbE/1GbE Transceiver (FTLX8574D3BCV) stopped working after firmware upgrade
Spectrum-2 | When device is rebooted with locked Optical Transceivers in split mode, the firmware may get stuck
Spectrum-2 | SN3700 | When connecting at 200GbE to Ixia K400, Ixia receives CRC errors
Spectrum-2 | SN3800 | On rare occasions packets loss may be experienced due to signal integrity issues
Spectrum-2 | When the port is a member of a LAG, after a warmboot and port toggle on the peer-side, the port remains down
Spectrum-3 | SN4700 | While using Optic cable in Split 4x1 mode in PAM4, when two first ports are toggled, the other 2 ports go down
Spectrum-3 | SN4700 | When working in 400GbE, deleting the headroom configuration (changing buffer size to zero) on the fly may cause continual packet drops
SAI
All | sFlow | Use hardcoded value 1 as netlink group number ax expected by hsflowd
- How I did it
Update the related version number in the make files and update the submodule pointer accordingly.
- How to verify it
Run regression test and everything works good.
#### Why I did it
Recently, CLI sfputil replace the old sonic platform utils with sonic platform API. However, sonic platform API does not support SFP low power mode and reset related operation. The PR is to fix it.
The change to replace platform utils with sonic platform API was reverted on 202012, once this PR is merged, we can cherry-pick these two PRs to 202012 together.
#### How I did it
In low power mode and reset related operation, use "docker exec" if the command is running on host side.
- Why I did it
Update MFT tool version to 4.16.0
Bugs fixes:
mlxlink: Fixed an issue that caused the margin scan to fail with the following message: Eye scan not completed.
mlxcable: Cable firmware burning capability is not supported.
New features:
mlxlink: Enabled margin scan on Network links.
mlxlink: Added PRBS TX/RX polarity inversion using the following flags: --invert_tx_polarity / --invert_rx_polarity
- How I did it
Update MFT make file with new version number.
- How to verify it
Build image and test related functions on Mellanox platform