Why I did it
This was an ask by Microsoft to provide:
7260 config.bcm file for hardware sku Arista-7260CX3-D92C16 (Named Arista-7260CX3-D96C16).
There are 16 100G uplinks:
Ethernet13-20/1
Ethernet45-52/1
All other ports are breakout to 2 50G ports.
How I did it
Copied existing Arista-7260CX3-D108C8 HWSKU and altered the bcm.config and port_config.ini files.
How to verify it
The new 100G ports do come up with a 201811 image using this HWSKU.
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
Signed-off-by: bingwang <wang.bing@microsoft.com>
Why I did it
This PR brings two changes
Add lossy PG profile for PG2 and PG6 on T1 for ports between T1 and T2.
After PR Update qos config to clear queues for bounced back traffic #10176 , the DSCP_TO_TC_MAP and TC_TO_PG_MAP is updated when remapping is enable
DSCP_TO_TC_MAP
Before After Why do this change
"2" : "1" "2" : "2" Only change for leaf router to map DSCP 2 to TC 2 as TC 2 will be used for lossless TC
"6" : "1" "6" : "6" Only change for leaf router to map DSCP 6 to TC 6 as TC 6 will be used for lossless TC
TC_TO_PRIORITY_GROUP_MAP
Before After Why do this change
"2" : "0" "2" : "2" Only change for leaf router to map TC 2 to PG 2 as PG 2 will be used for lossless PG
"6" : "0" "6" : "6" Only change for leaf router to map TC 6 to PG 6 as PG 6 will be used for lossless PG
So, we have two new lossy PGs (2 and 6) for the T2 facing ports on T1, and two new lossless PGs (2 and 6) for the T0 facing port on T1.
However, there is no lossy PG profile for the T2 facing ports on T1. The lossless PGs for ports between T1 and T0 have been handled by buffermgrd .Therefore, We need to add lossy PG profiles for T2 facing ports on T1.
We don't have this issue on T0 because PG 2 and PG 6 are lossless PGs, and there is no lossy traffic mapped to PG 2 and PG 6
Map port level TC7 to PG0
Before the PCBB change, DSCP48 -> TC 6 -> PG 0.
After the PCBB change, DSCP48 -> TC 7 -> PG 7
Actually, we can map TC7 to PG0 to save a lossy PG.
How I did it
Update the qos and buffer template.
How to verify it
Verified by UT.
Why I did it
As part of PCBB changes, we need to enable 2 extra lossless queues. The changes in this PR are done to adjust only the reserved sizes on Th2 for the additional 2 lossless queues
Calculations are done based on 40 downlinks for T1 and 16 uplinks for dual ToR
How to verify it
Verified that the rendering works fine on Th2 dut
Unit tests have been updated to reflect the modified buffer sizes when pcbb is enabled. There are existing testcases that will test the original buffer sizes when pcbb is disabled. With these changes, was able to build sonic-config-engine wheel successfully
Signed-off-by: Neetha John <nejo@microsoft.com>
Signed-off-by: bingwang <bingwang@microsoft.com>
Why I did it
This PR is to add two extra lossless queues for bounced back traffic.
HLD sonic-net/SONiC#950
SKUs include
Arista-7050CX3-32S-C32
Arista-7050CX3-32S-D48C8
Arista-7260CX3-D108C8
Arista-7260CX3-C64
Arista-7260CX3-Q64
How I did it
Update the buffers.json.j2 template and buffers_config.j2 template to generate new BUFFER_QUEUE table.
For T1 devices, queue 2 and queue 6 are set as lossless queues on T0 facing ports.
For T0 devices, queue 2 and queue 6 are set as lossless queues on T1 facing ports.
Queue 7 is added as a new lossy queue as DSCP 48 is mapped to TC 7, and then mapped into Queue 7
How to verify it
Verified by UT
Verified by coping the new template and generate buffer config with sonic-cfggen
* [Tunnel PFC] Tests for adding property 'sai_remap_prio_on_tnl_egress'
Add tests for adding property 'sai_remap_prio_on_tnl_egress', this
property should only be added in dual tor environment.
Test done:
Run test test_j2files.py
Co-authored-by: richardyu <richardyu@contoso.com>
* [Tunnel PFC] Add property for tunnel PFC
Replace the config.bcm file with j2 template file
- Add 'sai_remap_prio_on_tnl_egress=1' property when device metadata local
- Host subtype is 'dualtor'
- Change sai.profile foe the new config.bcm.j2
* [device config] Adding configuration for default route fallback
* Set sai_tunnel_underlay_route_mode attribute to fallback to default route if more specific route is unavailable.
#### Why I did it
Add platform_asic file to each platform folder in sonic-device-data package. The file content will be used as the ground truth of mapping from PLATFORM_STRING to switch ASIC family.
One use case of the mapping is to prevent installing a wrong image, which targets for other ASIC platforms. For example, currently we have several ONIE images naming as sonic-*.bin, it's easy to mistakenly install the wrong image. With this mapping built into image, we could fetch the ONIE platform string, and figure out which ASIC it is using, and check we are installing the correct image.
After this PR merged, each platform vendor has to add one mandatory text file `device/PLATFORM_VENDOR/PLATFORM_STRING/platform_asic`, with the content of the platform's switch ASIC family.
I will update https://github.com/Azure/SONiC/wiki/Porting-Guide after this PR is merged.
You can get a list of the ASIC platforms by `ls -b platform | cat`. Currently the options are
```
barefoot
broadcom
cavium
centec
centec-arm64
generic
innovium
marvell
marvell-arm64
marvell-armhf
mellanox
nephos
p4
vs
```
Also support
```
broadcom-dnx
```
#### How I did it
#### How to verify it
Test one image on DUT. And check the folders under `/usr/share/sonic/device`
Depends on Azure/sonic-utilities#1626
Depends on Azure/sonic-swss#1754
QOS tables in config db used ABNF format i.e "[TABLE_NAME|name] to refer fieldvalue to other qos tables.
Example:
Config DB:
"Ethernet92|3": {
"scheduler": "[SCHEDULER|scheduler.1]",
"wred_profile": "[WRED_PROFILE|AZURE_LOSSLESS]"
},
"Ethernet0|0": {
"profile": "[BUFFER_PROFILE|ingress_lossy_profile]"
},
"Ethernet0": {
"dscp_to_tc_map": "[DSCP_TO_TC_MAP|AZURE]",
"pfc_enable": "3,4",
"pfc_to_queue_map": "[MAP_PFC_PRIORITY_TO_QUEUE|AZURE]",
"tc_to_pg_map": "[TC_TO_PRIORITY_GROUP_MAP|AZURE]",
"tc_to_queue_map": "[TC_TO_QUEUE_MAP|AZURE]"
},
This format is not consistent with other DB schema followed in sonic.
And also this reference in DB is not required, This is taken care by YANG "leafref".
Removed this format from all platform files to consistent with other sonic db schema.
Example:
"Ethernet92|3": {
"scheduler": "scheduler.1",
"wred_profile": "AZURE_LOSSLESS"
},
Dependent pull requests:
#7752 - To modify platfrom files
#7281 - Yang model
Azure/sonic-utilities#1626 - DB migration
Azure/sonic-swss#1754 - swss change to remove ABNF format
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
Why I did it
To support dynamic port breakout Broadcom configurations on Arista platforms.
How I did it
Updated platform.json for platforms and added new hwsku, Broadcom config, and hwsku.json for dynamic port breakout usage.
The name of the new hwsku name used is very similar to the platform name (platform x86_64-arista_7050_qx32s hwsku Arista-7050QX-32S) as the flex hwsku is meant to be the default in the future.
How to verify it
Boot up device with the new hwsku, interfaces are up.
Change hwsku.json with new default breakout mode and reload device, breakout will have successfully been applied.
What I did:
Updated 7260 MMU Profile based on latest MSFT Tier 1 Tomahawk2_MMU_Setting_48x100G_40m_16x100G_300m_v1.0 and
TH2_PGHdrm_MSFT.
How I verify:
Made sure image is up/traffic is flowing/mmu dump looked fine.
SAI qos test need will be updated to support this SKU.
Why I did it
Arista-7260CX3-Q64 is missing T1 MMU configuration.
How I did it
Define T1 MMU configuration for Arista-7260CX3-Q64.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* 7260cx3 DualToR config.bcm support based on DualToR setting in device metadata at boot time.
For HWSKU Arista-7260CX3-C64 the MMU setting SOC for T0/T1 is also combined into the config.bcm.j2 logic so use just one config file and adding delta based on Switch Roles.
- Why I did it
The pcie configuration file location is under plugin directory not under platform directory.
#6437
- How I did it
Move all pcie.yaml configuration file from plugin to platform directory.
Remove unnecessary timer to start pcie-check.service
Move pcie-check.service to sonic-host-services
- How to verify it
Verify on the device
Prevent system-healthd from service from failing at boot time due to missing configuration.
Also adds basic support for healthd.
The following caveat exists with this placeholder configuration:
- No PSU monitoring (sensors/fans)
- No ASIC temperature monitoring
platform.json is needed for sonic-mgmt testing. Also in the future it will be used as part of dynamic port breakout.
Also removed the folder symlink for BlackhawkDD because it has a different platform.json than BlackhawkO.
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
- Enable thermalctld support for our platforms
- Fix Chassis.get_num_sfp which had an off by one
- Implement read_eeprom and write_eeprom in SfpBase
- Refactor of Psus and PsuSlots. Psus they are now detected and metadata reported
- Improvements to modular support
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
However in SAI 3.7 default behaviout got changes to 128 Group and 128
Memeber each.
This change is to make sure we are using same ECMP Group/Memeber Per
Group for 3.7 also so that behaviour is consistent.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
as needed by SAI 3.7 and above. Without this change
Warmboot fails from 3.5 to 3.7 as Braodcoam Datastructure
gets corrupted after warm-boot.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
thermalctld throwing error messages because it is not yet fully configured, disabling it for now on arista platforms.
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
* Remove the divide by 4 operation to the under the hood SAI
This is to avoid the need and thus the confusion for application program to know
the mmu internal architecture
This change must have support from SAI change to reach the correct
config
Signed-off-by: Wenda <wenni@microsoft.com>
* Relegate the divide by 4 operation to the under the hood SAI for egress
lossless pool
Extend to 7060 and 6100
Signed-off-by: Wenda <wenni@microsoft.com>
* Add more TH/TH2 hwskus
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Update config test
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Add TH2 ingress lossy profile
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Move the divide by 4 operation to SAI internal
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* [bcm SAI] Upgrade Broadcom SAI to version 3.5.3.1-15
- Broadcom SAI 3.5 GA release 20190924.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* Fix showing systemd shutdown sequence when verbose is set
* Fix creation of kernel-cmdline file
Sometimes boot0 prints error
"mv: can't preserve ownership of '/mnt/flash/image-arsonic.xxxx/kernel-cmdline': Operation not permitted"
* Improve flash space usage during installation
Some older systems only have 2GB of flash available. Installing a second
image on these can prove to be challenging.
The new installation process moves the installer swi to memory in order
to avoid free up space from the flash before uncompressing it there.
It removes all the flash space usage spike and also improves the IO
since the installation is no more reading and writting to the flash at
the same time.
* Add support of 7060CX-32S-SSD
* 7260CX3: use inventory powerCycle procedures
* 7050QX-32S: use inventory powerCycle procedures
* 7050QX-32: use inventory powerCycle procedures
* platform: arista: add common platform_reboot
Replace platform_reboot by a link to new common for devices already
using a similar script.
* 7060CX-32S: use inventory powerCycle procedures
* Install python smbus in pmon
Some platform plugin need the python smbus library to perform some actions.
This installs the dependency.
* QoS config change: 1) DSCP mapping; 2) link pg/queue 6 to lossy buffer;
3) redistribute scheduler
Signed-off-by: Wenda <wenni@microsoft.com>
* Add scheduling weight to queue 2
Signed-off-by: Wenda <wenni@microsoft.com>
* Link pg/queue 2 to lossy buffer
Signed-off-by: Wenda <wenni@microsoft.com>
* Update the pg headroom for a7060-D48C8 50G
Signed-off-by: Wenda <wenni@microsoft.com>
* Update config gen test for qos
Signed-off-by: Wenda <wenni@microsoft.com>
* Update pg headroom size, and update egress lossy pool size accordingly
Signed-off-by: Wenda <wenni@microsoft.com>
* Update headroom pool size; Update ingress service pool and egress lossy
pool sizes accordingly;
Signed-off-by: Wenda <wenni@microsoft.com>
* a7260: update headroom pool size; Update ingress service pool and egress lossy pool sizes accordingly;
Signed-off-by: Wenda <wenni@microsoft.com>
* Update config gen test for buffer
Signed-off-by: Wenda <wenni@microsoft.com>
* Unify qos config with qos_config.j2 template
Signed-off-by: Wenda <wenni@microsoft.com>
* Change 7050 to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: device/arista/x86_64-arista_7050_qx32/Arista-7050-QX32/qos.json.j2
modified: device/arista/x86_64-arista_7050_qx32s/Arista-7050-QX-32S/qos.json.j2
* Change a7060, a7260, s6000, s6100, z9100 to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
* Change mlnx devices to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: ../../../mellanox/x86_64-mlnx_msn2100-r0/ACS-MSN2100/qos.json.j2
modified: ../../../mellanox/x86_64-mlnx_msn2410-r0/ACS-MSN2410/qos.json.j2
modified: ../../../mellanox/x86_64-mlnx_msn2700-r0/ACS-MSN2700/qos.json.j2
modified: ../../../mellanox/x86_64-mlnx_msn2700-r0/Mellanox-SN2700-D48C8/qos.json.j2
* Change barefoot devices to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: barefoot/x86_64-accton_wedge100bf_32x-r0/montara/qos.json.j2
modified: barefoot/x86_64-accton_wedge100bf_65x-r0/mavericks/qos.json.j2
* Change accton as7212 to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: accton/x86_64-accton_as7212_54x-r0/AS7212-54x/qos.json.j2
* Apply PORT_QOS_MAP to active ports only
Signed-off-by: Wenda <wenni@microsoft.com>
* Update qos config test with qos_config.j2 template
Signed-off-by: Wenda <wenni@microsoft.com>
* Update sample output of qos-dell6100.json
Signed-off-by: Wenda <wenni@microsoft.com>
* Remove generating the default port name and index list, i.e., remove the generate_port_lists macro, because PORT is always defined
Signed-off-by: Wenda <wenni@microsoft.com>
* Include pfc_to_pg_map according to platform asic type obtained from
/etc/sonic/sonic_version.yml rather than specifying per hwsku
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Customize TC_TO_PRIORITY_GROUP_MAP and
PFC_PRIORITY_TO_PRIORITY_GROUP_MAP for barefoot
Signed-off-by: Wenda <wenni@microsoft.com>
* Unify PFC_PRIORITY_TO_PRIORITY_GROUP_MAP: remove "0":"0", "1":"1" as
these two pgs do not generate PFC frames.
Signed-off-by: Wenda <wenni@microsoft.com>
* [updategraph] add support to use preset config instead of default minigraph
* Fix variable case
* Remove default minigraph case
* Remove default minigraphs and add default_sku files