- Why I did it
Update platform data files for SN4800 to support chassis management
- How I did it
Update pcie.yml
Update sensors.conf
Update platform.json
- How to verify it
Run platform test suite in sonic-mgmt
- Why I did it
The MSN4410 platform was missing 2x100G and 4x50G supported breakout modes in platform.json
- How I did it
Added the aforementioned breakout modes to platform.json
- How to verify it
Run show interface breakout on a MSN4410 and verify that 2x100G and 4x50G are listed in the supported breakout modes for ports 1-24.
This change introduces 3 columns in the port_config.ini file.
These are coreId, corePortId and numVoq.
The ports for inband and recirc were also renamed properly.
Why I did it
Support Nokia ixr7250E IMM and Supervisor cards
How I did it
Added modules x86_64-nokia_ixr7250e_sup-r0 and x86_64-nokia_ixr7250e_36x400g-r0 ../device/nokia directory.
Modified the platform/broadcom/one-image.mk to include NOKIA_IXR7250_PLATFORM_MODULE
Modified the platform/broadcom/rule.mk to include the platform-module-nokia.mk
Why I did it
The SFP1 port was disabled in the default configuration.
How I did it
This commit enables the 10G front port for usage.
This was done using a DX030 together with an Arista switch using bcmsh and phy diag xe0 dsc to figure out what lane mappings make sense.
Validated on Celestica Seastone2 DX030.
How to verify it
Own a Celestica DX030
Connect the front SFP1 port to something.
It works :-)
You can do tcpdump -i Ethernet128 -n and you will see both incoming and outgoing LLDP.
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
Why I did it
To support dynamic port breakout Broadcom configurations on Arista platforms.
How I did it
Updated platform.json for platforms and added new hwsku, Broadcom config, and hwsku.json for dynamic port breakout usage.
The name of the new hwsku name used is very similar to the platform name (platform x86_64-arista_7050_qx32s hwsku Arista-7050QX-32S) as the flex hwsku is meant to be the default in the future.
How to verify it
Boot up device with the new hwsku, interfaces are up.
Change hwsku.json with new default breakout mode and reload device, breakout will have successfully been applied.
#### Why I did it
The values of the syseeprom were not valid
#### How I did it
I took the correct hexdump values from a real switch and created this hex file again
#### How to verify it
decode-syseeprom will display the new values
Deliver sfputil support for sfputil show eeprom and sfputil reset along with some component test case fixes
Co-authored-by: Carl Keene <keene@nokia.com>
* add hwsku.json for the Nokia-7215
* added required default_brkout_mode to hwsku as its not optional
* remove tabs from the file so spacing consistent
Co-authored-by: Carl Keene <keene@nokia.com>
#### Why I did it
New SN410 A1 system has a different sensor layout with A0 system, needs a new sensor conf file to support it.
#### How I did it
Since the SN4410 A1 system use exactly the same sensor layout as the SN4700 A1 system, so add a symbol link linking to the SN4700 A1 sensor conf file to reuse.
#### How to verify it
Run sensor test against the SN4410 A1 system;
Run platform related regression test against the SN4410 A1 system
Co-authored-by: Arun LK <Arun_L_K@dell.com>
Why I did it
Support for show system-health command in s5232f
How I did it
Added the configuration, API changes to support system health
How to verify it
Execute "show system-health summary/detail/monitor-list" CLI.
* Update default cable len to 0m for TD2 (#8298)
* Update sonic-cfggen tests with the correct cable len
Signed-off-by: Neetha John <nejo@microsoft.com>
As part of the buffer reclamation efforts for TD2, setting the default cable len to 0m which means unused ports will have a cable len of 0m.
Why I did it
To align with the changes in Azure/sonic-swss#1830
How to verify it
- With the default cable len set to 0m and the associated changes in swss, CABLE_LENGTH table had '0m' set for unused ports and accordingly more space was reserved for the shared pool
- Cfggen tests passed with the cable len update
Why I did it
To support "pcied" and "pcieutil" commands in DellEMC Z9332f.
How I did it
Add 'pcie.yaml' in device/dell/[PLATFORM]/ directory.
How to verify it
Execute "pcieutil check" command.
Logs: UT_logs.txt
Signed-off-by: Neetha John <nejo@microsoft.com>
As part of the buffer reclamation efforts for TD2, setting the default cable len to 0m which means unused ports will have a cable len of 0m.
Why I did it
To align with the changes in Azure/sonic-swss#1830
How to verify it
With the default cable len set to 0m and the associated changes in swss, CABLE_LENGTH table had '0m' set for unused ports and accordingly more space was reserved for the shared pool
- Improve chassis linecard restartability
- Fix 'show system-health' cli by adding non standard api
- Fix ledd crash on linecards with Recycle/Inband ports
- Refactor DPM management and add ADM1266 support
- Add state machine to update DPM RTC clock periodically
- Improve xcvr temperature reporting
- Fix lane mapping and `default_sku` for `x86_64-arista_7170_32c` platform
- Fix `7170-32C/CD` platform definition
1. Implement FanDrawer-Fan hierarchy.
2. Enable thermalctld, disable pcied.
3. Implement SystemLED in Chassis.
4. Correct Fan direction
5. Implement require Fan APIs for SystemHealthMonitoring.
6. Handle non-ascii character while reading PSU model/serial num.
```
Check if System-health can pass the check and display the SystemLED correctly.
///////// booting, DIAG_LED = GREEN_BLINKING /////////
root@sonic:/tmp# show system-health detail
System is currently booting...
root@sonic:/tmp# cat /sys/class/leds/diag/brightness
5
///////// container_checker fail, DIAG_LED = AMBER /////////
root@sonic:/sys/bus/i2c/devices# show system-health detail
System status summary
System status LED STATUS_LED_COLOR_AMBER
Services:
Status: OK
Hardware:
Status: Not OK
Reasons: container_checker is not Status ok
System services and devices monitor list
Name Status Type
-------------------------- -------- ----------
container_checker Not OK Program
sonic OK System
rsyslog OK Process
root-overlay OK Filesystem
var-log OK Filesystem
routeCheck OK Program
diskCheck OK Program
container_memory_telemetry OK Program
FAN-1F OK Fan
FAN-1R OK Fan
FAN-2F OK Fan
FAN-2R OK Fan
FAN-3F OK Fan
FAN-3R OK Fan
PSU-1 FAN-1 OK Fan
PSU-2 FAN-1 OK Fan
PSU 1 OK PSU
PSU 2 OK PSU
System services and devices ignore list
Name Status Type
--------------- -------- ------
asic Ignored Device
psu.temperature Ignored Device
///////// skip container_checker, DIAG_LED = GREEN /////////
root@sonic:/sys/bus/i2c/devices# vi /usr/share/sonic/device/x86_64-accton_as4630_54te-r0/system_health_monitoring_config.json
root@sonic:/sys/bus/i2c/devices#
root@sonic:/sys/bus/i2c/devices#
root@sonic:/sys/bus/i2c/devices# show system-health detail
System status summary
System status LED STATUS_LED_COLOR_GREEN
Services:
Status: OK
Hardware:
Status: OK
System services and devices monitor list
Name Status Type
-------------------------- -------- ----------
sonic OK System
rsyslog OK Process
root-overlay OK Filesystem
var-log OK Filesystem
routeCheck OK Program
diskCheck OK Program
container_memory_telemetry OK Program
FAN-1F OK Fan
FAN-1R OK Fan
FAN-2F OK Fan
FAN-2R OK Fan
FAN-3F OK Fan
FAN-3R OK Fan
PSU-1 FAN-1 OK Fan
PSU-2 FAN-1 OK Fan
PSU 1 OK PSU
PSU 2 OK PSU
System services and devices ignore list
Name Status Type
----------------- -------- -------
container_checker Ignored Service
psu.temperature Ignored Device
asic Ignored Device
```
Signed-off-by: Sean Wu <sean_wu@edge-core.com>
- Why I did it
To fix failed test cases of Haliburton platform APIs that found on platform_tests script
- How I did it
Add device/celestica/x86_64-cel_e1031-r0/platform.json
Update functions to support python3.7
Add more functions follow latest sonic_platform_base
Fix the bug
- How to verify it
Run platform_tests script
Signed-off-by: Wirut Getbamrung [wgetbumr@celestica.com]
*Edited platform.json for 4600 & 4600C
*Edited hwsku.json and port_config.ini files for all the SKU's present under these platforms
Signed-off-by: Vivek Reddy Karri <vkarri@nvidia.com>
This reverts commit a557dbd97e.
Reverting this PR as it is not required currently for multi-asic VS.
multi-asic VS will come up with multiple instances of swss and syncd. syncd will use default hwinfo string, same as in single asic VS.
Why I did it
To determine the revision of the pcie.yaml to be used based on BIOS version in DellEMC S6100 platform.
Depends on: Azure/sonic-platform-common#195
How I did it
Added two revisions of pcie.yaml pcie_1.yaml and pcie_2.yaml
Included a platform-specific Pcie class to provide the revision of the pcie.yaml to be used by pcieutil/pcied.
How to verify it
Execute pcieutil check (Azure/sonic-utilities#1672) command and verify the list of PCIe devices displayed.
Logs: UT_logs.txt
#### Why I did it
Support API 2.0 for S5248F platform
#### How I did it
Making changes to S5248F platform specific directory
Co-authored-by: Arun LK <Arun_L_K@dell.com>
Why I did it
MMU configuration for DellEMC Z9332 systems in T0/T1 topology
How I did it
Updated config.bcm, QoS/Buffer pool and lossy/lossless profile settings
How to verify it
Verified that Dell systems are booting up fine and basic test cases passing.
Introduce new sonic-buildimage images for Broadcom DNX ASIC family.
sonic-broadcom-dnx.bin
sonic-aboot-broadcom-dnx.swi
How I did it
NO CHANGE to existing make commands
make init; make configure PLATFORM=broadcom; make target/sonic-aboot-broadcom.swi; make target/sonic-broadcom.bin
The difference now is that it will result in new broadcom images for DNX asic family as well.
sonic-broadcom.bin, sonic-broadcom-dnx.bin
sonic-aboot-broadcom.swi, sonic-aboot-broadcom-dnx.swi
Note: This PR also adds support for Broadcom SAI 5.0 (based on 1.8 SAI ) for DNX based platform + changes in platform x86_64-arista_7280cr3_32p4 bcm config files and platform_env.conf files
Add device and platform code for ix7-bwde, ix8a-bwde.
Support platform API 2.0 for all quanta platforms except for ix1b
Co-authored-by: robert.hong <robert.hong@qct.io>
- Why I did it
To create SDK dump on Mellanox devices when SDK event has occurred.
- How I did it
Set the SKUs keys needed to initialize the feature in SAI.
- How to verify it
Simulate SDK event and check that dump is created in the expected path.
- Why I did it
The default breakout mode according to hwsku.json for the MSN4410 is 1x400G and this is not a supported breakout mode according to its platform.json
This causes a conflict on boot of this platform and no containers on the switch will init successfully.
- How I did it
Referenced the platform specification files and updated platform.json
- How to verify it
Install master version of SONiC on MSN4410
Boot switch and verify swss is successfully running using docker ps
What I did:
Updated 7260 MMU Profile based on latest MSFT Tier 1 Tomahawk2_MMU_Setting_48x100G_40m_16x100G_300m_v1.0 and
TH2_PGHdrm_MSFT.
How I verify:
Made sure image is up/traffic is flowing/mmu dump looked fine.
SAI qos test need will be updated to support this SKU.
- Why I did it
Enhance the Python3 support for platform API. Originally, some platform APIs call SDK API which didn't support Python 3. Now the Python 3 APIs have been supported in SDK 4.4.3XXX, Python3 is completely supported by platform API
- How I did it
Start all platform daemons from python3
1. Remove #/usr/bin/env python at the beginning of each platform API file as the platform API won't be started as daemons but be imported from other daemons.
2. Adjust SDK API calls accordingly
- How to verify it
Manually test and run regression platform test
Signed-off-by: Stephen Sun <stephens@nvidia.com>