Signed-off-by: bingwang <wang.bing@microsoft.com>
Why I did it
This PR brings two changes
Add lossy PG profile for PG2 and PG6 on T1 for ports between T1 and T2.
After PR Update qos config to clear queues for bounced back traffic #10176 , the DSCP_TO_TC_MAP and TC_TO_PG_MAP is updated when remapping is enable
DSCP_TO_TC_MAP
Before After Why do this change
"2" : "1" "2" : "2" Only change for leaf router to map DSCP 2 to TC 2 as TC 2 will be used for lossless TC
"6" : "1" "6" : "6" Only change for leaf router to map DSCP 6 to TC 6 as TC 6 will be used for lossless TC
TC_TO_PRIORITY_GROUP_MAP
Before After Why do this change
"2" : "0" "2" : "2" Only change for leaf router to map TC 2 to PG 2 as PG 2 will be used for lossless PG
"6" : "0" "6" : "6" Only change for leaf router to map TC 6 to PG 6 as PG 6 will be used for lossless PG
So, we have two new lossy PGs (2 and 6) for the T2 facing ports on T1, and two new lossless PGs (2 and 6) for the T0 facing port on T1.
However, there is no lossy PG profile for the T2 facing ports on T1. The lossless PGs for ports between T1 and T0 have been handled by buffermgrd .Therefore, We need to add lossy PG profiles for T2 facing ports on T1.
We don't have this issue on T0 because PG 2 and PG 6 are lossless PGs, and there is no lossy traffic mapped to PG 2 and PG 6
Map port level TC7 to PG0
Before the PCBB change, DSCP48 -> TC 6 -> PG 0.
After the PCBB change, DSCP48 -> TC 7 -> PG 7
Actually, we can map TC7 to PG0 to save a lossy PG.
How I did it
Update the qos and buffer template.
How to verify it
Verified by UT.
Why I did it
As part of PCBB changes, we need to enable 2 extra lossless queues. The changes in this PR are done to adjust only the reserved sizes on Th2 for the additional 2 lossless queues
Calculations are done based on 40 downlinks for T1 and 16 uplinks for dual ToR
How to verify it
Verified that the rendering works fine on Th2 dut
Unit tests have been updated to reflect the modified buffer sizes when pcbb is enabled. There are existing testcases that will test the original buffer sizes when pcbb is disabled. With these changes, was able to build sonic-config-engine wheel successfully
Signed-off-by: Neetha John <nejo@microsoft.com>
Signed-off-by: bingwang <bingwang@microsoft.com>
Why I did it
This PR is to add two extra lossless queues for bounced back traffic.
HLD sonic-net/SONiC#950
SKUs include
Arista-7050CX3-32S-C32
Arista-7050CX3-32S-D48C8
Arista-7260CX3-D108C8
Arista-7260CX3-C64
Arista-7260CX3-Q64
How I did it
Update the buffers.json.j2 template and buffers_config.j2 template to generate new BUFFER_QUEUE table.
For T1 devices, queue 2 and queue 6 are set as lossless queues on T0 facing ports.
For T0 devices, queue 2 and queue 6 are set as lossless queues on T1 facing ports.
Queue 7 is added as a new lossy queue as DSCP 48 is mapped to TC 7, and then mapped into Queue 7
How to verify it
Verified by UT
Verified by coping the new template and generate buffer config with sonic-cfggen
* [Tunnel PFC] Tests for adding property 'sai_remap_prio_on_tnl_egress'
Add tests for adding property 'sai_remap_prio_on_tnl_egress', this
property should only be added in dual tor environment.
Test done:
Run test test_j2files.py
Co-authored-by: richardyu <richardyu@contoso.com>
* [Tunnel PFC] Add property for tunnel PFC
Replace the config.bcm file with j2 template file
- Add 'sai_remap_prio_on_tnl_egress=1' property when device metadata local
- Host subtype is 'dualtor'
- Change sai.profile foe the new config.bcm.j2
* Removed unused default_config.json
* Remove asic.conf file from HW SKUs directories as they are not used by upstream code
* Enable dynamic PCI ID identification on Otterlake2
Co-authored-by: Maxime Lorrillere <mlorrillere@arista.com>
Why I did it
Fixes some pmon errors/warnings by providing missing configuration files
How I did it
Add missing pcie.yaml and sensors.conf for supported linecards
How to verify it
pcie-check should pass
sensors should display proper sensor names
Why I did it
The buffer pool & profile setting in buffer template was not correct and caused the errors like the following:
ERR swss#orchagent: :- parseReference: malformed reference:[BUFFER_PROFILE|ingress_lossless_profile]. Must not be surrounded by [ ]
How I did it
Fix the buffer pool & profile setting by removing "[]".
How to verify it
Loaded image with this fix in a switch and made sure the error was not seen anymore.
The v0.7.5 has bug fix for the support of gearbox port and macsec counters. It also includes a owl firmware update with owl.lz4.fw.1.94.0.bin.
How I did it
Update credo sai url for v0.7.5
Update gearbox_config.json with using firmware owl.lz4.fw.1.94.0.bin instead of owl.lz4.fw.1.92.1.bin
How to verify it
Test gearbox port and macsec counter successfully on A7280.
This PR includes necessary changes for correct generating BUFFER_QUEUE values in DB. Changes are based on the schema.md
Why I did it
Change format of generating BUFFER_QUEUE in DB according to schema.md and yang-model.
Old format:
"BUFFER_QUEUE": {
"Ethernet0,Ethernet100,Ethernet104,Ethernet108,Ethernet112,Ethernet116,Ethernet12,Ethernet120,Ethernet124,Ethernet16,Ethernet20,Ethernet24,Ethernet28,Ethernet32,Ethernet36,Ethernet4,Ethernet40,Ethernet44,Ethernet48,Ethernet52,Ethernet56,Ethernet60,Ethernet64,Ethernet68,Ethernet72,Ethernet76,Ethernet8,Ethernet80,Ethernet84,Ethernet88,Ethernet92,Ethernet96|queue": {
"profile": "profile"
},
"Ethernet0,Ethernet100,Ethernet104,Ethernet108,Ethernet112,Ethernet116,Ethernet12,Ethernet120,Ethernet124,Ethernet16,Ethernet20,Ethernet24,Ethernet28,Ethernet32,Ethernet36,Ethernet4,Ethernet40,Ethernet44,Ethernet48,Ethernet52,Ethernet56,Ethernet60,Ethernet64,Ethernet68,Ethernet72,Ethernet76,Ethernet8,Ethernet80,Ethernet84,Ethernet88,Ethernet92,Ethernet96|queue": {
"profile": "profile"
}
},
New format:
"BUFFER_QUEUE": {
"Ethernet0|queue": {
"profile": "profile"
},
"Ethernet0|queue": {
"profile": "profile"
},
"Ethernet4|queue": {
"profile": "profile"
},
"Ethernet4|queue": {
"profile": "profile"
},
"Ethernet8|queue": {
"profile": "profile"
},
"Ethernet8|queue": {
"profile": "profile"
},
...
}
How I did it
Updated structure of buffers_defaults jinja templates.
Signed-off-by: Oleksandr Kozodoi <oleksandrx.kozodoi@intel.com>
* [device config] Adding configuration for default route fallback
* Set sai_tunnel_underlay_route_mode attribute to fallback to default route if more specific route is unavailable.
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
Why I did it
Arista 7060 platform has a rare and unreproduceable PCIe timeout that could possibly be solved with increasing the switch PCIe timeout value. To do this we'll call a script for this platform to increase the PCIe timeout on boot-up.
No issues would be expected from the setpci command. From the PCIe spec:
"Software is permitted to change the value in this field at any
time. For Requests already pending when the Completion
Timeout Value is changed, hardware is permitted to use either
the new or the old value for the outstanding Requests, and is
permitted to base the start time for each Request either on when
this value was changed or on when each request was issued. "
How I did it
Add "platform-init" support in swss docker similar to how "hwsku-init" is called, only this would be for any device belonging to a platform. Then the script would reside in device data folder.
Additionally, add pciutils dependency to docker-orchagent so it can run the setpci commands.
How to verify it
On bootup of an Arista 7060, can execute:
lspci -vv -s 01:00.0 | grep -i "devctl2"
In order to check that the timeout has changed.
- Use SfpOptoeBase by default to leverage new `sonic_xcvr` refactor
- Add support for `Woodleaf` product
- Move `libsfp-eeprom.so` to a different `.deb` package
- Add new logrotate configuration for arista logs
- Improve logging mechanism for the drivers (IO loglevel, fix syslog duplicates)
- Initialize chassis cards in parallel
- Refactor of `get_change_event` to fix interrupts treated as presence change
#### Why I did it
Add platform_asic file to each platform folder in sonic-device-data package. The file content will be used as the ground truth of mapping from PLATFORM_STRING to switch ASIC family.
One use case of the mapping is to prevent installing a wrong image, which targets for other ASIC platforms. For example, currently we have several ONIE images naming as sonic-*.bin, it's easy to mistakenly install the wrong image. With this mapping built into image, we could fetch the ONIE platform string, and figure out which ASIC it is using, and check we are installing the correct image.
After this PR merged, each platform vendor has to add one mandatory text file `device/PLATFORM_VENDOR/PLATFORM_STRING/platform_asic`, with the content of the platform's switch ASIC family.
I will update https://github.com/Azure/SONiC/wiki/Porting-Guide after this PR is merged.
You can get a list of the ASIC platforms by `ls -b platform | cat`. Currently the options are
```
barefoot
broadcom
cavium
centec
centec-arm64
generic
innovium
marvell
marvell-arm64
marvell-armhf
mellanox
nephos
p4
vs
```
Also support
```
broadcom-dnx
```
#### How I did it
#### How to verify it
Test one image on DUT. And check the folders under `/usr/share/sonic/device`
Depends on Azure/sonic-utilities#1626
Depends on Azure/sonic-swss#1754
QOS tables in config db used ABNF format i.e "[TABLE_NAME|name] to refer fieldvalue to other qos tables.
Example:
Config DB:
"Ethernet92|3": {
"scheduler": "[SCHEDULER|scheduler.1]",
"wred_profile": "[WRED_PROFILE|AZURE_LOSSLESS]"
},
"Ethernet0|0": {
"profile": "[BUFFER_PROFILE|ingress_lossy_profile]"
},
"Ethernet0": {
"dscp_to_tc_map": "[DSCP_TO_TC_MAP|AZURE]",
"pfc_enable": "3,4",
"pfc_to_queue_map": "[MAP_PFC_PRIORITY_TO_QUEUE|AZURE]",
"tc_to_pg_map": "[TC_TO_PRIORITY_GROUP_MAP|AZURE]",
"tc_to_queue_map": "[TC_TO_QUEUE_MAP|AZURE]"
},
This format is not consistent with other DB schema followed in sonic.
And also this reference in DB is not required, This is taken care by YANG "leafref".
Removed this format from all platform files to consistent with other sonic db schema.
Example:
"Ethernet92|3": {
"scheduler": "scheduler.1",
"wred_profile": "AZURE_LOSSLESS"
},
Dependent pull requests:
#7752 - To modify platfrom files
#7281 - Yang model
Azure/sonic-utilities#1626 - DB migration
Azure/sonic-swss#1754 - swss change to remove ABNF format
Why I did it
Fix an issue on the Clearwater2 linecard.
When the linecard is started with a fresh image without configuration, phys would not be initialized.
How I did it
Added default_sku for Clearwater2 which prevents config-setup from failing to create a default config_db.json.
Added some extra logic in the phy-credo-init script to run the phy_config.sh of the hwsku pointed by default_sku if the DEVICE_METADATA.localhost.hwsku information is not populated in CONFIG_DB.
How to verify it
Booting an image with this change and without configuration will lead to the phys being initialized using the phy_config.sh from default_sku.
- Disable health monitoring of `psu.voltage` until support is implemented
- chassis: disable provisioning bit once linecard has booted
- chassis: fix issue in `show version` when running as `admin`
- chassis: fix race when reading an eeprom before it's available
- chassis: implement `get_all_asics` call
- api: fix `ChassisBase.get_system_eeprom_info` implementation
- api: add missing thermal condition and info
- api: fix return value of `ChassisBase.set_status_led`
- sfp: introduce SfpOptoeBase implementation used based on configuration knob
- psu: rely on pmbus to read input/output status when other mechanism is missing
- misc: other refactors and improvements
Why I did it
The first 4 ports on this dut are breakout ports. They might not always be connected in lab. Mark them as 'RJ45' to skip the SFP check since they are by default disabled.
How to verify it
run platform test_reboot.py
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
This change introduces 3 columns in the port_config.ini file.
These are coreId, corePortId and numVoq.
The ports for inband and recirc were also renamed properly.
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
Why I did it
To support dynamic port breakout Broadcom configurations on Arista platforms.
How I did it
Updated platform.json for platforms and added new hwsku, Broadcom config, and hwsku.json for dynamic port breakout usage.
The name of the new hwsku name used is very similar to the platform name (platform x86_64-arista_7050_qx32s hwsku Arista-7050QX-32S) as the flex hwsku is meant to be the default in the future.
How to verify it
Boot up device with the new hwsku, interfaces are up.
Change hwsku.json with new default breakout mode and reload device, breakout will have successfully been applied.
* Update default cable len to 0m for TD2 (#8298)
* Update sonic-cfggen tests with the correct cable len
Signed-off-by: Neetha John <nejo@microsoft.com>
As part of the buffer reclamation efforts for TD2, setting the default cable len to 0m which means unused ports will have a cable len of 0m.
Why I did it
To align with the changes in Azure/sonic-swss#1830
How to verify it
- With the default cable len set to 0m and the associated changes in swss, CABLE_LENGTH table had '0m' set for unused ports and accordingly more space was reserved for the shared pool
- Cfggen tests passed with the cable len update
Signed-off-by: Neetha John <nejo@microsoft.com>
As part of the buffer reclamation efforts for TD2, setting the default cable len to 0m which means unused ports will have a cable len of 0m.
Why I did it
To align with the changes in Azure/sonic-swss#1830
How to verify it
With the default cable len set to 0m and the associated changes in swss, CABLE_LENGTH table had '0m' set for unused ports and accordingly more space was reserved for the shared pool
- Improve chassis linecard restartability
- Fix 'show system-health' cli by adding non standard api
- Fix ledd crash on linecards with Recycle/Inband ports
- Refactor DPM management and add ADM1266 support
- Add state machine to update DPM RTC clock periodically
- Improve xcvr temperature reporting
- Fix lane mapping and `default_sku` for `x86_64-arista_7170_32c` platform
- Fix `7170-32C/CD` platform definition
Introduce new sonic-buildimage images for Broadcom DNX ASIC family.
sonic-broadcom-dnx.bin
sonic-aboot-broadcom-dnx.swi
How I did it
NO CHANGE to existing make commands
make init; make configure PLATFORM=broadcom; make target/sonic-aboot-broadcom.swi; make target/sonic-broadcom.bin
The difference now is that it will result in new broadcom images for DNX asic family as well.
sonic-broadcom.bin, sonic-broadcom-dnx.bin
sonic-aboot-broadcom.swi, sonic-aboot-broadcom-dnx.swi
Note: This PR also adds support for Broadcom SAI 5.0 (based on 1.8 SAI ) for DNX based platform + changes in platform x86_64-arista_7280cr3_32p4 bcm config files and platform_env.conf files
What I did:
Updated 7260 MMU Profile based on latest MSFT Tier 1 Tomahawk2_MMU_Setting_48x100G_40m_16x100G_300m_v1.0 and
TH2_PGHdrm_MSFT.
How I verify:
Made sure image is up/traffic is flowing/mmu dump looked fine.
SAI qos test need will be updated to support this SKU.
Process pcied failed on Arista-7170-32CD-C32
```
root@sonic:/# supervisorctl
chassis_db_init EXITED Jun 03 08:48 AM
dependent-startup EXITED Jun 03 08:48 AM
ledd RUNNING pid 28, uptime 3:07:49
lm-sensors EXITED Jun 03 08:48 AM
pcied FATAL Exited too quickly (process log may have details)
```
Signed-off-by: Andriy Kokhan <andriyx.kokhan@intel.com>
Why I did it
7050 S4Q31 mmu configuration is missing ALPM configurations, causing not enough memory reserved for routes. Orchagent crashes on a nightly testbed with 6400 route entries.
How I did it
Add the missing ALPM configurations.
How to verify it
Load the configuration on testbed and verified new configuration exists and no more crash.
Signed-off-by: Ying Xie ying.xie@microsoft.com
This PR contains the following changes
Original Arista-7050-QX-32S sku (32x40G ports) has been renamed to Arista-7050QX32S-Q32
Arista-7050-QX-32S is symlinked to Arista-7050QX-32S-S4Q31 (4x10G, 31x40G ports)
Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
Arista-7260CX3-Q64 is missing T1 MMU configuration.
How I did it
Define T1 MMU configuration for Arista-7260CX3-Q64.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
PG profile settings need to be aligned with Arista-7050-QX-32S
How I did it
Copy over the current settings from Arista-7050-QX-32S and define params for 10G and 1G speeds as well
Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
Need proper MMU and Qos settings for Arista-7050QX-32S-S4Q31
How I did it
Updated the settings based on Arista-7050-QX-32S
Platform library changes
- Fix the use of /proc/modules during testing, fixes#7463
- Add `libsfp-eeprom.so` build to read/write xcvr eeproms in C
- Add some more reboot-cause information
- Write down temperature hw thresholds to the sensors
- Report software thresholds through platform api
- Writ `port_name sysfs` file of optoe`
- Tests enhancements
- Fix dependency issues for chassis provisioning
Platform configuration changes
- Add `pcie.yaml` configuration for a few platforms
- Mount `libsfp-eeprom.so` inside `pmon`
- Fix `Arista-7050SX3-48C8` and `Arista-7050SX3-48YC8' platform and hwsku
- Miscellaneous fixes
Co-authored-by: Boyang Yu <byu@arista.com>
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
#### Why I did it
- To start support of dynamic port breakout as the norm for Arista platforms.
- Add a DPB hwsku for the 7060CX-32S
#### How I did it
- Expand platform.json for the 7060CX-32S
- Added a new hwsku specifically for DPB
- Added a flex Broadcom configuration
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
This change introduces dynamic port breakout (DPB) for Arista 7050 QX32 model by adding a new SKU suffixed with `-Flex`.
The breakout configuration allowed is the same as in mainline Arista EOS, i.e. 24 first ports are allowed to be used in 4x10G in addition to the default 40G mode. The last 8 ports are fixed to 40G. This is due to ASIC limitations of a total of 104 max ports.
**NOTE**: As described in https://github.com/aristanetworks/sonic/issues/30#issuecomment-820584113 front panel LEDs are likely not working when operating in breakout mode. It is not clear if the LEDs work correctly in 40G mode as I have not had a chance to physically inspect the switch with this patch.
Signed-off-by: Christian Svensson <blue@cmd.nu>
Set hierarchical ecmp level to 2 instead of 3. Based on CS00011833367, ecmp level must be set to 2.
This is already handled for TH2 platforms. Change is required only for TD3
Co-authored-by: Ubuntu <prsunny@prince-vm.vzw1i4tqyeburcdz5lrgulxi2c.yx.internal.cloudapp.net>
* 7260cx3 DualToR config.bcm support based on DualToR setting in device metadata at boot time.
For HWSKU Arista-7260CX3-C64 the MMU setting SOC for T0/T1 is also combined into the config.bcm.j2 logic so use just one config file and adding delta based on Switch Roles.
Dynamic Port Breakout fall in case "autoneg" field exist in config_db.
- How I did it
Added "autoneg" field in sonic-port yang model.
- How to verify it
Add "autoneg" field into config_db like this:
"Ethernet8": {
"index": "2",
"lanes": "8,9,10,11",
"fec": "rs",
"pfc_asym": "off",
"mtu": "9100",
"alias": "Ethernet8",
"admin_status": "up",
"autoneg": "on",
"speed": "100000",
},
As booting on DCS-7060DX4-32 would use the default sku of DCS-7060PX4-32 which is not compatible,
thus move some files around to properly separate the configurations that are device specific.
Signed-off-by: Samuel Angebault <staphylo@arista.com>
- Why I did it
The pcie configuration file location is under plugin directory not under platform directory.
#6437
- How I did it
Move all pcie.yaml configuration file from plugin to platform directory.
Remove unnecessary timer to start pcie-check.service
Move pcie-check.service to sonic-host-services
- How to verify it
Verify on the device
- Add support for `DCS-7050SX3-48YC8` and `DCS-7050SX3-48C8` platform
- Add support for more variants of `DCS-7280CR3-32[PD]4`
- Add Supervisor to Linecard consutil support
- Complete Watchdog platform API support
- Fix some PSU behavior on `DCS-7050QX-32` and `DCS-7060CX-32S`
- Fix SEU management on `DCS-7060CX-32S`
- Allow kernel modules to build up to linux 5.10
- Rename led color `orange` to `amber`
- Miscellaneous fixes
Port_config update for hwsku 7050CX3-32S-C3 - add two 10G ports.
This change is added to fix issue of "PortsOrch initialization failure" seen by previous removal of these 10G ports.
Tested on the device with new minigraph, and the PortsOrch initialization failure is not seen.
port_config.ini for HWSKU Arista-7050CX3-32S-C32 has missing speed column and duplicated lanes.
The incorrect speed causes issues in Orchagent RESTARTCHECK as the below task remains as the remaining item during swss shutdown.
Prevent system-healthd from service from failing at boot time due to missing configuration.
Also adds basic support for healthd.
The following caveat exists with this placeholder configuration:
- No PSU monitoring (sensors/fans)
- No ASIC temperature monitoring
platform.json is needed for sonic-mgmt testing. Also in the future it will be used as part of dynamic port breakout.
Also removed the folder symlink for BlackhawkDD because it has a different platform.json than BlackhawkO.
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
Current support for the 7060PX4-32 and 7060DX4 was broken.
With this change, ports are now linking fine.
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
Rename chip name dps1900-i2c-X-58 to pmbus-i2c-X-58 in sensors.conf for Arista 7170 due to latest updates for Arista driver submodules #5686. After these updates adapter dps1900 was renamed and sensors.conf file is not applied properly. Issue was observed started from BFN SONiC image 16.
Signed-off-by: Nazar Tkachuk <nazarx.tkachuk@intel.com>
Submodule updates include the following commits:
* src/sonic-utilities 9dc58ea...f9eb739 (18):
> Remove unnecessary calls to str.encode() now that the package is Python 3; Fix deprecation warning (#1260)
> [generate_dump] Ignoring file/directory not found Errors (#1201)
> Fixed porstat rate and util issues (#1140)
> fix error: interface counters is mismatch after warm-reboot (#1099)
> Remove unnecessary calls to str.decode() now that the package is Python 3 (#1255)
> [acl-loader] Make list sorting compliant with Python 3 (#1257)
> Replace hard-coded fast-reboot with variable. And some typo corrections (#1254)
> [configlet][portconfig] Remove calls to dict.has_key() which is not available in Python 3 (#1247)
> Remove unnecessary conversions to list() and calls to dict.keys() (#1243)
> Clean up LGTM alerts (#1239)
> Add 'requests' as install dependency in setup.py (#1240)
> Convert to Python 3 (#1128)
> Fix mock SonicV2Connector in python3: use decode_responses mode so caller code will be the same as python2 (#1238)
> [tests] Do not trim from PATH if we did not append to it; Clean up/fix shebangs in scripts (#1233)
> Updates to bgp config and show commands with BGP_INTERNAL_NEIGHBOR table (#1224)
> [cli]: NAT show commands newline issue after migrated to Python3 (#1204)
> [doc]: Update Command-Reference.md (#1231)
> Added 'import sys' in feature.py file (#1232)
* src/sonic-py-swsssdk 9d9f0c6...1664be9 (2):
> Fix: no need to decode() after redis client scan, so it will work for both python2 and python3 (#96)
> FieldValueMap `contains`(`in`) will also work when migrated to libswsscommon(C++ with SWIG wrapper) (#94)
- Also fix Python 3-related issues:
- Use integer (floor) division in config_samples.py (sonic-config-engine)
- Replace print statement with print function in eeprom.py plugin for x86_64-kvm_x86_64-r0 platform
- Update all platform plugins to be compatible with both Python 2 and Python 3
- Remove shebangs from plugins files which are not intended to be executable
- Replace tabs with spaces in Python plugin files and fix alignment, because Python 3 is more strict
- Remove trailing whitespace from plugins files
Need A mmu configuration to get the device going without generating lots of warnings.
Similar to dummy MMU configuration for Arista-7050CX3-32S-C32, this configuration will need to be updated with correct numbers. This MMU configuration is copied from 7060 comparable hwsku.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
Treat devices that are ToRRouters (ToRRouters and BackEndToRRouters) the same when rendering templates
Except for BackEndToRRouters belonging to a storage cluster, since these devices have extra sub-interfaces created
Treat devices that are LeafRouters (LeafRouters and BackEndLeafRouters) the same when rendering templates
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
- Why I did it
On Arista-7050CX3-32S-C32, there are constant stream of errors like following.
Nov 3 21:56:24.415190 str2-7050cx3-acs-06 NOTICE swss#orchagent: :- registerInWdDb: No lossless TC found on port Ethernet68
Which causes:
loganalyzer to claim test failed.
leaving the system without MMU configuration. Which couldn't be good for any IO test.
- How I did it
Added these MMU configuraions are copied from another platform and guaranteed to be incorrect for hwsku Arista-7050CX3-32S-C32.
Adding them so that we have A MMU configuration and the system won't throw a whole bunch of errors and leave MMU unconfigured. The correct MMU configuration will come later.
This configuration is definitely not suitable for testing system performance or QoS behavior.
Signed-off-by: Ying Xie ying.xie@microsoft.com
- How to verify it
Test will have chance to pass. Ran a few test that would fail otherwise.
We don't need a custom platform reboot on Clearwater2(Ms). They are expected to be rebooted via a normal linux soft reboot.
Remove symlink to the arista common platform reboot for those 2 platforms.
- Enable thermalctld support for our platforms
- Fix Chassis.get_num_sfp which had an off by one
- Implement read_eeprom and write_eeprom in SfpBase
- Refactor of Psus and PsuSlots. Psus they are now detected and metadata reported
- Improvements to modular support
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
bring up chassisdb service on sonic switch according to the design in
Distributed Forwarding in VoQ Arch HLD
Signed-off-by: Honggang Xu <hxu@arista.com>
**- Why I did it**
To bring up new ChassisDB service in sonic as designed in ['Distributed forwarding in a VOQ architecture HLD' ](90c1289eaf/doc/chassis/architecture.md).
**- How I did it**
Implement the section 2.3.1 Global DB Organization of the VOQ architecture HLD.
**- How to verify it**
ChassisDB service won't start without chassisdb.conf file on the existing platforms.
ChassisDB service is accessible with global.conf file in the distributed arichitecture.
Signed-off-by: Honggang Xu <hxu@arista.com>
This is to fix pcie firmware check assert in Broadcom SDK once the SAI changes merges. This will be in the future but adding the soc property in the broadcom config now.
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
However in SAI 3.7 default behaviout got changes to 128 Group and 128
Memeber each.
This change is to make sure we are using same ECMP Group/Memeber Per
Group for 3.7 also so that behaviour is consistent.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
- Merge chassis codebase upstream
- Add support for Otterlake supervisor
- Add support for NorthFace and Camp chassis
- Add support for Eldridge, Dragonfly and Brooks fabrics
- Add support for Clearwater2 and Clearwater2Ms linecards
- Add new arista Cli to power on/off cards
- Add new arista show Cli to inspect supervisor, chassis, fabrics and linecards
as needed by SAI 3.7 and above. Without this change
Warmboot fails from 3.5 to 3.7 as Braodcoam Datastructure
gets corrupted after warm-boot.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>