- Why I did it
Change thermal recover threshold from temp_trip_norm to temp_trip_high, so that thermal algorithm would set fan speed to minimum allowed earlier and save power.
- How I did it
Change thermal recover threshold from temp_trip_norm to temp_trip_high
- How to verify it
Manual test
Changes:
-- pre Process Grouping section from all yang models, so it can be used
from any yang model.
-- add jsondiff in setup.py, it is useful for test debugging in case of
failures.
-- use 'stypes' instead of head.
-- pass config DB table name in _createLeafDict().
-- added test config for grouping.
-- white spaces changes.
Note: Changes are done in the way that we can add support for other
Generic YANG statement easily for translation.
Signed-off-by: Praveen Chaudhary pchaudhary@linkedin.com
How I did it
Added if multi npu check before invoking the load global config.
How to verify it
Restart caclmgrd after this change and check if no error log is thrown.
Depends on Azure/sonic-utilities#1626
Depends on Azure/sonic-swss#1754
QOS tables in config db used ABNF format i.e "[TABLE_NAME|name] to refer fieldvalue to other qos tables.
Example:
Config DB:
"Ethernet92|3": {
"scheduler": "[SCHEDULER|scheduler.1]",
"wred_profile": "[WRED_PROFILE|AZURE_LOSSLESS]"
},
"Ethernet0|0": {
"profile": "[BUFFER_PROFILE|ingress_lossy_profile]"
},
"Ethernet0": {
"dscp_to_tc_map": "[DSCP_TO_TC_MAP|AZURE]",
"pfc_enable": "3,4",
"pfc_to_queue_map": "[MAP_PFC_PRIORITY_TO_QUEUE|AZURE]",
"tc_to_pg_map": "[TC_TO_PRIORITY_GROUP_MAP|AZURE]",
"tc_to_queue_map": "[TC_TO_QUEUE_MAP|AZURE]"
},
This format is not consistent with other DB schema followed in sonic.
And also this reference in DB is not required, This is taken care by YANG "leafref".
Removed this format from all platform files to consistent with other sonic db schema.
Example:
"Ethernet92|3": {
"scheduler": "scheduler.1",
"wred_profile": "AZURE_LOSSLESS"
},
Dependent pull requests:
#7752 - To modify platfrom files
#7281 - Yang model
Azure/sonic-utilities#1626 - DB migration
Azure/sonic-swss#1754 - swss change to remove ABNF format
Why I did it
When feature state is set to always_enabled hostcfgd throws error message
Sep 21 22:30:55.135377 r-leopard-32 ERR /hostcfgd: Unexpected state value 'always_enabled' for feature bgp
Sep 21 22:30:55.420268 r-leopard-32 ERR /hostcfgd: Unexpected state value 'always_enabled' for feature database
Sep 21 22:30:58.672714 r-leopard-32 ERR /hostcfgd: Unexpected state value 'always_enabled' for feature swss
This is due to feature == always_enabled not handled properly.
How I did it
Handled the scenario when feature is always enabled
How to verify it
Restart hostcfgd with feature state configured as always_enabled and check if there are no errors.
Added UT to cover the scenario.
Why I did it
SONiC YANG model support for warm restart.
How I did it
Defined warm restart YANG containers and lists based on config-DB schema.
How to verify it
Successful build of the following packages:
make target/python-wheels/sonic_yang_models-1.0-py3-none-any.whl
make target/python-wheels/sonic_yang_mgmt-1.0-py3-none-any.whl
Signed-off-by: Arthi Sivanantham <arthi_sivanantham@dell.com>
*[Submodule] update for swss with following commits:
a3fdaf4 QOS fieldvalue reference ABNF format to string changes ([sonic-platform-daemons] Update submodule #1754)
a8fcadf Add sleep to ensure starting route perf test after the vs is stable ([mellanox]: Update hw-mgmt service with the stop action #1929)
a89d1f8 Fix failing DPB LAG tests ([socat]: build socat with readline #1919)
86b4ede [portsorch] Avoid orchagent crash when set invalid interface types to port (Upgrade azure-keyvault to known compatible version #1906)
025032f [VS] Skip failing test - test_recirc_port ([rsyslog]: use # to separate container and program name in syslog msg #1918)
d338bd0 [pfcwd] Fix the polling interval time granularity (Download newer version (8.23.0-2) of rsyslog from jessie-backports in hopes of eliminating memory leaks #1912)
14c937e Enabling copp tests ([Mellanox] Update hw-management service config #1914)
fbdcaae [teammgrd]: Improve LAGs cleanup on shutdown: send SIGTERM directly to PID. ([docker-syncd-mlnx] add new mlnx-sfpd daemon to docker-syncd-mlnx #1841)
002bb1d [tlm teamd] Add retry mechanism before logging the ERR in get_dumps. ([py-swss/config] config load-minigraph failure leaves database in wrong state #1629)
57d21e7 [pfcwd] Convert polling interval from ms to us in LUA scripts ([interfaces]: Move IP/MTU information from interfaces file into database #1908)
d01524d [fgnhgorch] Enable packet flow when no FG ECMP neighbors are resolved (Update arista driver submodule to includes interrupt handling changes #1900)
8cf355d Mux state order change ([submodule] update snmpagent and dbsyncd, extending/implementing ieee802.1ab, rfc3433, rfc2737 MIBs #1902)
Why I did it
Added support for the device S5224F
How I did it
Implemented the support for the platform S5224F
Switch Vendor: DellEMC
Switch SKU: S5224F-ON
ASIC Vendor: Broadcom
SONiC Image: sonic-broadcom.bin
How to verify it
Verified the show platform/interface commands
Why I did it
Added support for the device N3248PXE
How I did it
Implemented the support for the platform N3248PXE
n3248pxe_unit_test_log.txt
Switch Vendor: DellEMC
* Switch SKU: N3248PXE
* ASIC Vendor: Broadcom
* SONiC Image: sonic-broadcom.bin
How to verify it
Verified the show platform commands
Why I did it
To be able to run VS test on official multi asic VS image.
How I did it
Add a new script to build multi-asic VS image by passing NUM_ASIC build parameter.
Rung multi-asic t1-lag test cases with the built image.
As a part of warmboot, redis database is dumped:
c97fe546e5/scripts/fast-reboot (L269)
However, this dump file is deleted, after it is loaded back into db post reboot.
The DB dump can be useful for debugging purpose, hence taking a backup of it can be useful.
Instead of deleting the dump, rename and keep the dump.
Why I did it
Added support for the device N3248TE
How I did it
Implemented the support for the platform N3248TE
Switch Vendor: DellEMC
Switch SKU: N3248TE
ASIC Vendor: Broadcom
SONiC Image: sonic-broadcom.bin
How to verify it
Verified the show platform commands
The following fixes are included:
b502743 [gearbox] Since ASIC_DB, as well its COUNTER_DB, FLEX_COUNTER_DB use separator ':', GB_ASIC_DB
should use same ((Azure/sonic-swss-common#532)
81182ec Added support for setting TTL on a Table managed entry. ((Azure/sonic-swss-common#526)
Added sonic-pfcwd.yang file that defines the yang model for PFC watch dog parameters
sonic-pfcwd.yang is required for configuring action, detection_time, restoration time of PFC watchdog on the interface port.
This PR aims to fix the healthd crash issue by adding system health monitoring configuration file for platform Celestica E1031 by adding a new configuration file under the path device/celestica/x86_64-cel_e1031-r0/.
How to verify it
I manually restart the system-health.service and confirmed that healthd is running.
Signed-off-by: Yong Zhao <yozhao@microsoft.com>
Added logrotate file for wtmp and btmp to override default conf and set size cap as 100K as done in
PR: #865. For buster this is control by separate file wtmp and btmp.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
2cd6236 [voq][chassis] Fix for issue in chassis redis server connection check (#110)
9da577d [port_util] Fix issue in function get_interface_oid_map (#114)
740a44c [port_util] Allow system without ports in config db run without errors (#109)
d07682e Merge pull request #111 from xumia/azp-coverage
482cac2 [Ethernet-IB][index] Modifed the port_util to support the VoQ Inband Port (#113)
69eac92 Support azp diff coverage
Signed-off-by: liora <liora@nvidia.com>
* [multi-asic][cli][chassis-db] Avoiding connecting to chassis db
Currently, for all the cli commands, we connect to all databases
mentioned in the database_config.json. The database_config.json also
includes the databases from chassis redis server from supervisor card.
It is unneccessary to connect to databases from chassis redis server
when cli commands are executed form linecard. But we need to allow
connection to chassis databases when the cli commands are executed from
supervisor card.
The changes in this PR fixes this problem. This PR requires that
asic.conf in supervisor card includes VOQ_SUPERVISOR with value 1 to
indentify the supervisor card. The connect_to_all_dbs_for_ns() is
changed to skip chassis databases form the list of collected databases
if the card is not supervisor card.
What I did:
add platform components
How I did it:
In platform_components.json add chassis and empty component
How to verify it:
Run show platform firmware updates
*Removed execute permissions from the systemd copp-config.service file.
Without this we will get a warning: "Configuration file /lib/systemd/system/copp-config.service is marked executable. Please remove executable permission bits. Proceeding anyway."
To Fix#8697 . The config load_minigraph initializes 'admin_status' to up when platform.json has DPB configs. This doesn't happen when using port_config.ini
The update minigraph has logic to initialize only the ports whose neighbors are defined or those belonging to portchannel
However, a change was introduced to have default admin status to be 'up' in portconfig.py when the minigraph was using platform.json
This will lead to sanity check failure in sonic-mgmt and thus no test cases could be run
Why I did it
fstrim has dependency on pmon docker.
How I did it
start fstrim timer after sonic.target.
How to verify it
local test and PR test.
Signed-off-by: Ying Xie ying.xie@microsoft.com
- Why I did it
Removed 2x40G for SN3800. This mode is not supported by hardware.
- How I did it
Removing it from hwsku.json and platform.json
- How to verify it
Load it in the device and check supported modes
* [Nokia ixs7215] Miscellaneous platform API fixes
This commit delivers the following fixes for the Nokia ixs7215 platform
- Fix bug in a fan API error path
- Add support for setting the fan drawer led
- Add support for getting/setting the front panel PSU status led
- Add support for getting the min/max observed temperature value
* [Nokia ixs7215] code review changes: temperature min/max values
Fix#8722
retreat two commits which cause warm reboot regression
* eb79ca4 2021-09-01 | [pbh]: Add PBH OA (#1782) [Nazarii Hnydyn]
* 3d6b1f0 2021-08-31 | [buffer orch] Bugfix: Don't query counter SAI_BUFFER_POOL_STAT_XOFF_ROOM_WATERMARK_BYTES on a pool where it is not supported (#1857) [Stephen Sun]
Signed-off-by: Guohan Lu <lguohan@gmail.com>