- What I did
Updating FEC value and SAI download link
- How I did it
Updating related switch configuration files in device/ingrasys
Updating sai.mk files in platform/nephos
- How to verify it
Checking system and network feature is worked as well
- Description for the changelog
Updating FEC value and SAI download link for Ingrasys S9130-32X/S9230-64X
- A picture of a cute animal (not mandatory but encouraged)
Signed-off-by: Sam Yang <yang.kaiyu@gmail.com>
This commit adds new support for dynamic buffer configuation. Adding pg_profile
lookup table for supporting the buffer profile using cable length and port speed.
Lookup table entries are calculated based on formula for different cable length and speed.
The 50G entries needs to be updated once again as we are waiting for the interface sublayer
MAC delay values.
Additionally fixed some issues in the buffers.json.j2 file.
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@dell.com>
* Upgrade linux-image version
* Add missing dependency of igb
* Fix mft build rule
* Add missing dependency of ixgbe
* [Broadcom]: Update OpenNSL modules to be compatible with kernel 3.16.0-5 (#3)
* [Nephos] Update SDK version to support new kernel module 3.16.0-5 (#4)
* [mellanox]: Update URL for SDK (#5)
When teamd service restarted, the port channels will be recreated.
Dhcp relay service needs to be restarted after that to listen on the
right port channels.
Python packages, having their version changed, will fail to build
because deb_dist directory contains both build directories for old and
new version, and (for some uncleaer reason) debian utilities don't know
which one to choose.
Signed-off-by: marian-pritsak <marianp@mellanox.com>
* Add patch to prevent 'supervisorctl start' command from hanging if system time has rolled backward
* Also add unit tests for clock rollback scenarios
* Fix build of libsaithrift for broadcom
* Restore libsaithrift-dev building
* Comment out libsaithrift library on cavium and marvell. Both of them have old SAI drivers
* Revert back unintentional acton changes
* Don't run the package checks when building sairedis package
- What I did
Updating switch configuration files and download link
- How I did it
Updating related switch configuration files in device/ingrasys
Updating related mk files in platform/nephos
- How to verify it
Check system and network feature is worked as well
- Description for the changelog
Update switch configuration files and download link for Ingrasys S9130-32X/S9230-64X
- A picture of a cute animal (not mandatory but encouraged)
Signed-off-by: Sam Yang <yang.kaiyu@gmail.com>
This reverts commit 64602ad5b2.
Reverting this commit because the root cause of the issue was due to
a Broadcom SDK bug which caused VLAN-tagged packets to be tagged twice.
When packets were double-tagged, only one tag was getting stripped before
the packet was trapped to the CPU. However, the second tag was left behind,
which would cause the DHCP relay agent to ignore the packet. The bug has
since been fixed, so now all VLAN-tagged packets should properly have their
tag removed before being trapped to the CPU. Therefore the DHCP relay
agent should never encounter a VLAN-tagged packet.