- change the references to 'type' field to 'sub_role'
- change the references to 'InternalFrontend' and 'InternalBackend' to 'FrontEnd' and 'BackEnd' respectively
- add a statement to reflect route-reflector for backend asics
- add a change to set "next-hop-self force" configuration for internal BGP session in multi asic platform.
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
[configdb.py]: Allow deletion of entire table from mod_config API. (#61)
[MultiDB] mimic redis-dump-load , adding sonic_db_dump_load.py and so…
[MultiDB] add sonic-db-cli PING all instances support (#65)
Fix sonic-db-cli script to be compatible with python3 and python2.7 (#66)
Namespace support in SonicV2Connector (#63)
[Multiasic]: Add calculation of interface index for backplane interfa…
- Changes to minigraph.py to parse minigraph.xml of a multi asic platform
- Changes to portconfig.py to parse additional column "asic_port_name" in
port_config.ini
- Add a new option -n to sonic-cfggen for multi asic platforms
- Add unit tests for config generation for multi asic platforms
Signed-off-by: SuvarnaMeenakshi <sumeenak@microsoft.com>
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
Update SAI/SDK/FW and MSN4700 device files to support 8 lanes 400G
Update SAI to 1.16.3
Update SDK to 4.4.0914
Update FW to *.2007.1112
Update MSN4700 device files to support 8 lanes 400G
* [dhcpmon] Filter DHCP O/A Messages of Neighboring Vlans
This code fixes a bug where two or more vlans exist. Cross contamination
happens for DHCP packets Offer/Ack when received on shared northbound links.
The code filters out those packet based on dst IP equal Vlan loopback IP.
signed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
Extend the PMON daemon start control to lm-sensors and fancontrol.
change template docker-pmon.supervisord.conf.j2 and start.sh.j2 to have lm-sensors and fancontrol start scripts and supervisord config file controlled by pmon_daemon_control.json.
the intention is to avoid wrong daemon status in "supervisorctl status" output. For example, on some platform, if there is no fancontrol config file, and it is not ruled out from supervisord conf file and start.sh, we'll see fancontrol in "STOPPED" status from "supervisorctl status" output, which will violate some check in the platform test(check daemon status as expected)
[Vxlan] : adding show vnet/vxlan cmds (#880)
[show][bgp] Use only 'show ip bgp' as the base and use bgp_frr_v4 file
for FRR routing stack (#884)
[fast reboot] set a fast-reboot DB flag (#887)
[show] Add 'ip/ipv6 bgp network' commands (#888)
[routeorch] Handle the empty "nexthop" field for backward compatibility (#1263)
[vnet] Set MTU for the VNET bridge RIF in BITMAP implementation (#1271)
[vnet] Verify if BITMAP route exists before creating new one to avoid
dublication (#1272)
* New SKU support for MSN3420
Signed-off-by: Shlomi Bitton <shlomibi@mellanox.com>
Conflicts:
device/mellanox/x86_64-mlnx_msn2700-r0/plugins/sfputil.py
* Add CPLD's
* Symlink fixes and semantics
* Adding new platform at end of lines
- Added support for Thermal event in Last Reboot Reason "show reboot-cause" command.
- Added support for sending log message in case of thermal shutdown.
sonic NOTICE root: Shutting down due to over temperature (40 degree, 30 degree, 34 degree)
Remove skip_thermalctld as it is not available on 201911 branch
hardware daemons are not supported in kvm vs platform now
admin@vlab-01:/usr/share/sonic/device/x86_64-kvm_x86_64-r0$ docker exec -it pmon bash
root@vlab-01:/# supervisorctl status
fancontrol STOPPED Not started
lm-sensors STOPPED Not started
rsyslogd RUNNING pid 23, uptime 0:03:09
start.sh EXITED Apr 22 09:07 AM
supervisor-proc-exit-listener RUNNING pid 17, uptime 0:03:10
Signed-off-by: Guohan Lu <lguohan@gmail.com>
The one big bgp configuration template was splitted into chunks.
Currently we have three types of bgp neighbor peers:
general bgp peers. They are represented by CONFIG_DB::BGP_NEIGHBOR table entries
dynamic bgp peers. They are represented by CONFIG_DB::BGP_PEER_RANGE table entries
monitors bgp peers. They are represented by CONFIG_DB::BGP_MONITORS table entries
This PR introduces three templates for each peer type:
bgp policies: represent policieas that will be applied to the bgp peer-group (ip prefix-lists, route-maps, etc)
bgp peer-group: represent bgp peer group which has common configuration for the bgp peer type and uses bgp routing policy from the previous item
bgp peer-group instance: represent bgp configuration, which will be used to instatiate a bgp peer-group for the bgp peer-type. Usually this one is simple, consist of the referral to the bgp peer-group, bgp peer description and bgp peer ip address.
This PR redefined constant.yml file. Now this file has a setting for to use or don't use bgp_neighbor metadata. This file has more parameters for now, which are not used. They will be used in the next iteration of bgpcfgd.
Currently all tests have been disabled. I'm going to create next PR with the tests right after this PR is merged.
I'm going to introduce better bgpcfgd in a short time. It will include support of dynamic changes for the templates.
FIX:: #4231
[xcvrd] Extend xcvrd with SFP error event handling (#52)
[thermal fix] 1. Catch exception for each update iteration; 2. add
unit test (#51)
Add thermal control daemon to monitor FAN and thermal status and run
thermal policy (#49
Do not set PG to Buffer porfile mapping again if already exist. (#1261)
[sub intf] Use m_lag_id to be the parent port object id when parent port
is LAG (#1235)