* QoS config change: 1) DSCP mapping; 2) link pg/queue 6 to lossy buffer;
3) redistribute scheduler
Signed-off-by: Wenda <wenni@microsoft.com>
* Add scheduling weight to queue 2
Signed-off-by: Wenda <wenni@microsoft.com>
* Link pg/queue 2 to lossy buffer
Signed-off-by: Wenda <wenni@microsoft.com>
* Update the pg headroom for a7060-D48C8 50G
Signed-off-by: Wenda <wenni@microsoft.com>
* Update config gen test for qos
Signed-off-by: Wenda <wenni@microsoft.com>
* Update pg headroom size, and update egress lossy pool size accordingly
Signed-off-by: Wenda <wenni@microsoft.com>
* Update headroom pool size; Update ingress service pool and egress lossy
pool sizes accordingly;
Signed-off-by: Wenda <wenni@microsoft.com>
* a7260: update headroom pool size; Update ingress service pool and egress lossy pool sizes accordingly;
Signed-off-by: Wenda <wenni@microsoft.com>
* Update config gen test for buffer
Signed-off-by: Wenda <wenni@microsoft.com>
* 1) DSCP 46 to 5; 2) ecn config for lossless traffic; 3) ecn on by default; 4) DWRR equal weight;
Signed-off-by: Wenda <wenni@microsoft.com>
* 1) link pg & queue 5 to lossy buffer profile; 2) ingress lossless alpha 1/8
Signed-off-by: Wenda <wenni@microsoft.com>
* Update the test case for qos & buffer json template
Signed-off-by: Wenda <wenni@microsoft.com>
* Migrate a7050-qx32 and s6000 to use pg_profile lookup architecture
Signed-off-by: Wenda <wenni@microsoft.com>
* Update pg headroom egress service pool for a7050-qx-32s, a7050-qx32, and s6000
Signed-off-by: Wenda <wenni@microsoft.com>
* Link queue 5 to lossy profile
Signed-off-by: Wenda <wenni@microsoft.com>
By default, port channel members and VLAN members are set to admin
status UP. This configuration could be updated via the command:
config interface <interface_name> startup/shutdown
Signed-off-by: Shu0T1an ChenG <shuche@microsoft.com>
Remove the teamd.j2 templates used for starting the teamd. Add
teammgrd instead to manage all port channel related configuration
changes. Remove front panel port related configurations in
interfaces.j2 templates as well.
Remove teamd.sh script and use teammgrd to start all the teamd
processes. Remove all the logics in the start.sh script as well.
Update the sonic-swss submodule.
Signed-off-by: Shu0T1an ChenG <shuche@microsoft.com>
* Unify qos config with qos_config.j2 template
Signed-off-by: Wenda <wenni@microsoft.com>
* Change 7050 to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: device/arista/x86_64-arista_7050_qx32/Arista-7050-QX32/qos.json.j2
modified: device/arista/x86_64-arista_7050_qx32s/Arista-7050-QX-32S/qos.json.j2
* Change a7060, a7260, s6000, s6100, z9100 to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
* Change mlnx devices to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: ../../../mellanox/x86_64-mlnx_msn2100-r0/ACS-MSN2100/qos.json.j2
modified: ../../../mellanox/x86_64-mlnx_msn2410-r0/ACS-MSN2410/qos.json.j2
modified: ../../../mellanox/x86_64-mlnx_msn2700-r0/ACS-MSN2700/qos.json.j2
modified: ../../../mellanox/x86_64-mlnx_msn2700-r0/Mellanox-SN2700-D48C8/qos.json.j2
* Change barefoot devices to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: barefoot/x86_64-accton_wedge100bf_32x-r0/montara/qos.json.j2
modified: barefoot/x86_64-accton_wedge100bf_65x-r0/mavericks/qos.json.j2
* Change accton as7212 to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: accton/x86_64-accton_as7212_54x-r0/AS7212-54x/qos.json.j2
* Apply PORT_QOS_MAP to active ports only
Signed-off-by: Wenda <wenni@microsoft.com>
* Update qos config test with qos_config.j2 template
Signed-off-by: Wenda <wenni@microsoft.com>
* Update sample output of qos-dell6100.json
Signed-off-by: Wenda <wenni@microsoft.com>
* Remove generating the default port name and index list, i.e., remove the generate_port_lists macro, because PORT is always defined
Signed-off-by: Wenda <wenni@microsoft.com>
* Include pfc_to_pg_map according to platform asic type obtained from
/etc/sonic/sonic_version.yml rather than specifying per hwsku
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Customize TC_TO_PRIORITY_GROUP_MAP and
PFC_PRIORITY_TO_PRIORITY_GROUP_MAP for barefoot
Signed-off-by: Wenda <wenni@microsoft.com>
* Unify PFC_PRIORITY_TO_PRIORITY_GROUP_MAP: remove "0":"0", "1":"1" as
these two pgs do not generate PFC frames.
Signed-off-by: Wenda <wenni@microsoft.com>
* FRR 4.0 integration with SONiC
-- Uses SONiC FRR repo frr/4.0 (which has SONiC support) to build image
-- Makefile changes to make frr4.0 builtable.
-- Updated/Added FRR configuration files
-- bgpd jinja template fixes
To build SONiC images with FRR4.0, simply edit rules/config file and change
routing stack to following:
SONIC_ROUTING_STACK = frr
and then build images as usual.
* Used integrated-vtysh-config in FRR
Changed to single template: frr.conf.j2 for configuration and added tests
* [sonic-cfggen] Add support to generate sample t1 config
* Fix typo
* Fix space issue
* Add list of preset messages in help message
* Utilize choice support of argparse
* Fix missing module in setup.py
- Move front panel ports and port channels MTU and IP configurations out of
the current /etc/network/interfaces file and store them in the configuration
database.
- The default MTU value for both front panel ports and the port channels is
9100. They are set via the minigraph or 9100 by default.
- Introduce portmgrd which will pick up the MTU configurations from the
configuration database.
- The updated intfmgrd will pick up IP address changes from the configuration
database.
- Update sonic-swss submodule
Signed-off-by: Shu0T1an ChenG <shuche@microsoft.com>
* Moving get_routing_stack() to a centralized location to avoid code duplication
Various areas of sonic-utilities are now demanding this functionality so i'm simply moving this routing to a centralized location. After spending some time debating about the ideal location for this function, we thought about sonic-config-engine/sonic_platform.py as the closest match.
Functional tests' output will be provided as part of the equivalent PR to be submitted shortly within sonic-utilities repo.
* Adding comment to function.
* Initial commit
* Add Ingrasys S9180-32X platform dirver.
Signed-off-by: Wade He <chihen.he@gmail.com>
* Add bfn.service for init barefoot.
Signed-off-by: Wade He <chihen.he@gmail.com>
* [Barefoot Beta] Add some functions and fixed some bugs.
1. Update sensors.conf.
2. Fixed IO expander init.
3. Fixed PSU EEPROM.
4. Fixed MB EEPROM.
5. Add fancontrol and fan init.
6. Add SYS LED control (sys, fan, fan tray).
7. 2.5V compute and setup max and min.
8. Fixed typo MB eeprom delete address.
9. Remove coretemp to BMC.
10. Add active CPLD.
11. Modify SFP+ GPIO slave address.
12. Modify tmp75 Near Port 32 slave address.
Signed-off-by: Wade He <chihen.he@gmail.com>
* Add bfn script in /etc/init.d/
Signed-off-by: Wade He <chihen.he@gmail.com>
* Add bfn service in debian
Signed-off-by: Wade He <chihen.he@gmail.com>
* Fixed CPLD switch LED behavior.
Signed-off-by: Wade He <chihen.he@gmail.com>
* [Barefoot Beta] Fixed sensors and hwmon order.
1. Fixed ignore sensors Vbat.
2. Reorg hwmon order.
Signed-off-by: Wade He <chihen.he@gmail.com>
* Fixed PSU1 and PSU2 EEPROM order.
Signed-off-by: Wade He <chihen.he@gmail.com>
* initial barefoot checkin october 2017
* update refpoint
* update refpoints
* update refpoints to bf-master
* update refpoint
* update refpoint to tested version
* change to platform from asic
* update refpoint for swss
* revert core creation setting
* update refpoints
* add telnet for debug shell
* update refpoints 11/17/17
* missed change in file on previous merge
* [CPLD] Fixed blink LED issue.
* Fixed blink LED mask set error.
Signed-off-by: Wade He <chihen.he@gmail.com>
* Update bf_kdrv.c for 6.0.2.39
* Update bf kernel driver
* Add bf_fun kernel module.
* Update bf_tun for fixed build error
* merge with Azure master (12/12/17)
* update swss refpoint
* update refpoint of swss
* library dependency for stack unroll
* update refpoint to bf-master
* [DHCP relay]: Fix circuit ID and remote ID bugs (#1248)
* [DHCP relay]: Fix circuit ID and remote ID bugs
* Set circuit_id_len after setting circuit_id_len to ip->name
* [Platform] Add Psuutil and update sensors.conf for S9100-32X, S8810-32Q and S9200-64X (#1272)
* Add I2C CPLD kernel module for psuutil.
* Support psuutil script.
* Add voltage min and max threshold.
* Update sensors.conf for tmp75.
Signed-off-by: Wade He <chihen.he@gmail.com>
* Allow multi platform support - infra (more changes to follow)
* update relative path to include platform for clarity
* [Platform] Add Ingrasys S9130-32X and S9230-64X with Nephos Switch ASIC for "branch 201712" (#1274)
- What I did
Add switch ASIC vendor: Nephos
Add Nephos platforms: Ingrasys S9130-32X, Ingrasys S9230-64X
- How I did it
Add platform/nephos files
Add platform/nephos/sonic-platform-modules-ingrasys submodule
Add device/ingrasys/x86_64-ingrasys_s9130_32x-r0 files
Add device/ingrasys/x86_64-ingrasys_s9230_64x-r0 files
Add SONiC to support Nephos platform
Update Head of submodule src/sonic-sairedis to "3b817bb"
- How to verify it
To build SONiC installer image and docker images, run the following commands:
make configure PLATFORM=nephos
make target/sonic-nephos.bin
Check system and network feature is worked as well
- Description for the changelog
Add switch ASIC vendor and platforms for Nephos
- A picture of a cute animal (not mandatory but encouraged)
Signed-off-by: Sam Yang <yang.kaiyu@gmail.com>
* change source of files to github (from dropbox), update sairedis refpoint
* update refpoint of sairedis
* [centec] support CENTEC SAI 1.0 on 201712 branch and update e582-48x6q board (#1269)
* [marvel]: Marvell's updates for SONiC.201712 & SAI v1.0 (#1287)
* update sairedis (fast-boot refpoint)
* fix syncd rpc make files
* update refpoint to handle Makefile change (no functional change)
* [Marvell]: Add support for SLM5401-54x device (#1307)
* Marvell's updates for SONiC.201712 & SAI v1.0
* [Platform] Add Marvell's SLM5401-54x for branch 201712
* [Broadcom]: Update Boradcom SAI package to 3.0.3.3-3 (#1312) (#1321)
- update Arista 7050-QX32S config.bcm file
- update Accton th-as771*-32x100G.config.bcm files
* update refpoint for Makefile chnage in sairedis
* update refpoint - sairedis
* update sairedis to older refpoint till we debug clean build
* export asic platform for build
* update refpoint for makefiles
* [PLATFORM] Centec update E582 driver fan/epprom/sensor (#1332)
* Upload wnc-osw1800
* Modify for Barefoot suggest
* Revert bfn-platform.mk
* Update bfn-platform-wnc.mk
Update parameter name
* Update parameter name
* initial support for WNC platform
* change switch name to "switch"
* Delete bf modules for rel_7_0
* Add Ingrasys S9180 platform
Signed-off-by: Wade He <chihen.he@gmail.com>
* Modify bfnsdk for Ingrasys S9180 platform
Signed-off-by: Wade He <chihen.he@gmail.com>
* Resolved the conflict.
* Resolved the conflict.
* Update submodule path and url.
* Delete unused file.
* Update PSU GPIO and EEPROM for psuutil.
* Add psuutil in S9180-32X
Signed-off-by: Wade He <chihen.he@gmail.com>
* update refpoint
* update refpoint
* change contact email, update refpoint
* cleanup and update kernel modules
* updates based on review
* update refpoint
* update refpoint
* fix typo in config script to check for platforms
* remove stale file
* resolve conflicts
* cleanup diffs with Azure repo and update SDK debs
* update refpoints to Azure
* address review comments
* revert refpoint of swss-common
* porting the build fix from master
* porting build fix from master
* Minor Fix
* Minor fix
* Temp to sde deb packages url
* Update sonic - sairedis,swss & swss-common refpoints
* Update git modules url path to bfn repo
* updated paths for swss, swss-common & sairedis
* Update refpoint for sonic-swss to local bfn repo
* Update URL for downloading sde debian packages
* porting fix links of debian git server from master
* porting fix links of debian git server from master
* [Ingrasys] Add platform support for S9280-64X with Barefoot ASIC
* Update ref points for swss, swss-common and sairedis repos
* Add sonic platform scripts for bfn montara/maverick
* Call sh scripts instead of calling py scripts
* Address upstream PR Comments (#10)
* Update bf-master with azure/master
* Undo changes to some files
* Revert "Address upstream PR Comments (#10)"
This reverts commit a7fddb83ca.
* Address upstream comments (#11)
* Remove all non bfn specific changes from upstream PR
* Revert "Address upstream comments (#11)"
This reverts commit 559132103e.
* Undo non bfn changes
* Little more cleanup
* Add back code removed in merge
* export CONFIGURED_PLATFORM
* Update sairedis and swss refpoints
* Address Upstream PR comment
* change deb pkg dependency from 3.16.0-4-amd64 to 3.16.0-5-amd64
* Set default tx queue len for usb0 interface to 64
* Update sairedis refpoint
* Update swss ref point
* Add bfn buffer cfg files for montara/maverick as per new design
* Update buffer cfg templates for bfn montara
* add non zero size to buffer profile
* add macro to generate port lists
* Update buffer cfg templates for bfn mavericks
* add non zero size for buffer profiles
* add port generation macro
* Add missing psmisc package
* BGP docker seems to be missing killall utility being used by fast-reboot script. This is causing non graceful termination of BGP sessions.
Adding psmisc to resolve this issue.
* Update swss ref point
* Update swss ref point
* Update sairedis refpoint
* Update sairedis refpoint
* Update sairedis refpoint
* Update sairedis refpoint
* Update refpoint for sairedis and swss
* sairedis to azure master
* swss to latest bfn bf-master
* Update gitmodules
Update url for sairedis to azure master
* Correct typo in bfn platform script
* Update swss and sairedis ref points
* Update swss ref point
* Address Review comments
* Update swws path in gitmodules to azure master
* update swss refpoint
* update base docker j2 file -remove psmisc package (could be a concern, would cause fast reboot to not work correctly will fix in another PR)
* Fix sairedis refpoint broken in by previous merge
* Remove psmisc from docker base image
* This will break fast reboot as killall is required for killing bgp process and initiating graceful termination of BGP session.
Will fix this in a seperate PR. Need this for SONIC upstreaming
* Address upstream comments
* Remove bmc interface from interface jinja template and sample output interfaces file
* Add bmc interface at boot time to network interfaces for bfn bmc based platforms
* Remove autogen ingrasys debian files
* Revert "Remove autogen ingrasys debian files"
* Buffer and qos config template fix for bfn platforms (#21)
SWI-1509 Buffer and qos config template fix for bfn platforms
* Fix qos config files for montara & mavericks (#22)
* Reference only ppg 3,4 in qos files as no profiles are attached to 0,1 in buffer configs
* Fix vs test (#23)
* Use MAC from EEPROM for PortChannels
Signed-off-by: Andriy Moroz <c_andriym@mellanox.com>
* Use MAC from EEPROM in DEVICE_METADATA
Will affect MAC for VLAN interfaces
Signed-off-by: Andriy Moroz <c_andriym@mellanox.com>
* Get MAC via decode-syseeprom
Signed-off-by: Andriy Moroz <c_andriym@mellanox.com>
* hw-management is now a service
Signed-off-by: Andriy Moroz <c_andriym@mellanox.com>
* Add error handling for MAC fetch process
Signed-off-by: Andriy Moroz <c_andriym@mellanox.com>
* First part of skipping not used port for qos configuration
* Use active ports only to set QoS parameters for 6100
* Add a test for qos.json.j2
* Add a test for Dell S6100 buffers.json template
* Update submodulre
* Fix minigraph parser issue when handling LAG related ACL table configuration
* rephrase the warning message.
* pick up swss change in https://github.com/Azure/sonic-swss/pull/494
* Add noise config for PortChannel & EthernetInterface in simple-sample-graph.xml
* Add noise config for PORTCHANNEL_INTERFACE in simple-sample-graph.xml
Signed-off-by: Wenda <wenni@microsoft.com>
* Add noice config for DEVICE_NEIGHBOR in t0-sample-graph.xml
Add unit test against introducing ports not existing in port_config.ini
into DEVICE_NEIGHBOR
Signed-off-by: Wenda <wenni@microsoft.com>
* DeviceInterfaceLink in minigraph.xml can contain port not existing in
port_config.ini but contraining non-zero Bandwidth attribute
Add noice config in simple-sample-graph.xml to capture the case that
such a port is leaked into config_db.json
Signed-off-by: Wenda <wenni@microsoft.com>
* Protect PORTCHANNEL from ports not existing in port_config.ini
Signed-off-by: Wenda <wenni@microsoft.com>
* Protect PORTCHANNEL_INTERFACE from portchannels containing ports not
existing in port_config.ini
Signed-off-by: Wenda <wenni@microsoft.com>
* Protect DEVICE_NEIGHBOR from ports not existing in port_config.ini
Signed-off-by: Wenda <wenni@microsoft.com>
* Add noise config Ethernet1 in DeviceInterfaceLinks in simple-sample-graph.xml as it is in PortChannel1001
Signed-off-by: Wenda <wenni@microsoft.com>
* Add noise config Ethernet1 in DeviceInterfaceLinks in simple-sample-graph.xml as it is in PortChannel1001
Signed-off-by: Wenda <wenni@microsoft.com>
* Protect PORTCHANNEL from ports not existing in port_config.ini
Signed-off-by: Wenda <wenni@microsoft.com>
* Protect PORTCHANNEL_INTERFACE from portchannels containing ports not
existing in port_config.ini
Signed-off-by: Wenda <wenni@microsoft.com>
* Protect DEVICE_NEIGHBOR from ports not existing in port_config.ini
Signed-off-by: Wenda <wenni@microsoft.com>
* Correct space in minigraph.py
Signed-off-by: Wenda <wenni@microsoft.com>
* Does not allow non-port_config.ini port to get into the port list
Signed-off-by: Wenda <wenni@microsoft.com>
* Check PORTCHANNEL against PORT list only if port_config_file exists
Signed-off-by: Wenda <wenni@microsoft.com>
* Correct format
Signed-off-by: Wenda <wenni@microsoft.com>
* print warning when a port coming from DeviceInterfaceLink is not in
port_config.ini
Signed-off-by: Wenda <wenni@microsoft.com>
* Change Ethernet1 and 2 to fortyGigE0/1 and 2,respectively
Signed-off-by: Wenda <wenni@microsoft.com>
* Change Ethernet1 and 2 to fortyGigE0/1 and 2,respectively
Signed-off-by: Wenda <wenni@microsoft.com>
* print warning when ignoring ports, portchannels, portchannel interfaces, and
device neighbors
Update t0-sample-graph.xml with interface name 'fortyGigE0/2' and the
ACL_TABLE output
Signed-off-by: Wenda <wenni@microsoft.com>
* Fix minigraph parser issue when handling LAG related ACL table configuration
Changes to be committed:
modified: src/sonic-config-engine/minigraph.py
modified: src/sonic-config-engine/tests/test_cfggen.py
signed-off-by kebol@mellanox.com
* We don't need configure anything until we have interfaces created
* Don't run lldpcli for a port, until a port is up and running
* Remove lldpd socket before starting lldpd
* Fix sample files for lldpd configuration
* Another attempt to make the test working
* Quick fix for lldpd paused after start bug
Just a simple change to make sonic's user life a little bit easier. Displaying the multiple elements of config_db.json in an orderly fashion allows a more intuitive user-experience.
For this change i'm simply intercepting the config-state that is about to be dumped to config_db.json, and i'm placing it in an ordered-dictionary, so that information is pushed to file in natural/alphanumerical ordering.
Example:
admin@lnos-x1-a-csw01:~$ sudo sonic-cfggen -m /etc/sonic/minigraph.xml --print-data
{
...
"PORT": {
"Ethernet0": {
"alias": "Eth1/1",
"lanes": "65"
},
"Ethernet1": {
"alias": "Eth1/2",
"lanes": "66"
},
"Ethernet2": {
"alias": "Eth1/3",
"lanes": "67"
},
"Ethernet3": {
"alias": "Eth1/4",
"lanes": "68"
},
"Ethernet4": {
"alias": "Eth2/1",
"lanes": "69"
},
...
...
"INTERFACE": {
"Ethernet0|10.0.0.0/31": {},
"Ethernet1|10.0.0.2/31": {},
"Ethernet2|10.0.0.4/31": {},
"Ethernet3|10.0.0.6/31": {},
"Ethernet4|10.0.0.8/31": {},
* [sonic build] Define folder macro for target folder /usr/sonic/share/templates
* [sonic-cfggen] allow templates to include from common folders
- Allow templates to include files under /usr/share/sonic/templates
- Allow templates to include files in the same folder as the root template
* [Buffer config] install the buffer configuration template
* [Arista7260cx3] Add buffer configuration for Arista7260CX3 T0 topology
- pg profile look up table is incomplete. Currently contains T0 default
values.
* [Arista7260cx3] Adding QoS configuration
* Address review comments
1. Stop generating ingress pg configuration for lossless pgs.
2. Stop putting ports into speed sets, put all ports in one set.
3. Remove ingress lossless profiles.
4. Added some tailing '-' back to remove leading spaces.