This is to address an issue where it was observed that SAI operations sometime may take a very long to time complete (over 45ms). It was determined that the ALPM distributed thread was causing this issue.
The fix is to disable this debug thread that has no functional purpose.
Preliminary tests looks fine. BGP neighbors were all up with proper routes programmed
interfaces are all up
Manually ran the fib test cases on 7050CX3 (TD3), TD2, TH, TH2, and TH3 based platforms and
thy all passed.
Note: the testing was done over 20201230 image and are porting this change to master branch.
No need to port this to 20201230 branch as a separate PR was already done for that branch. (#9190)
this PR is created to port the changes made by (#9199) but could not be cherry picked directly to 202106 branch.
Set hierarchical ecmp level to 2 instead of 3. Based on CS00011833367, ecmp level must be set to 2.
This is already handled for TH2 platforms. Change is required only for TD3
Co-authored-by: Ubuntu <prsunny@prince-vm.vzw1i4tqyeburcdz5lrgulxi2c.yx.internal.cloudapp.net>
- Why I did it
The pcie configuration file location is under plugin directory not under platform directory.
#6437
- How I did it
Move all pcie.yaml configuration file from plugin to platform directory.
Remove unnecessary timer to start pcie-check.service
Move pcie-check.service to sonic-host-services
- How to verify it
Verify on the device
Port_config update for hwsku 7050CX3-32S-C3 - add two 10G ports.
This change is added to fix issue of "PortsOrch initialization failure" seen by previous removal of these 10G ports.
Tested on the device with new minigraph, and the PortsOrch initialization failure is not seen.
port_config.ini for HWSKU Arista-7050CX3-32S-C32 has missing speed column and duplicated lanes.
The incorrect speed causes issues in Orchagent RESTARTCHECK as the below task remains as the remaining item during swss shutdown.
Prevent system-healthd from service from failing at boot time due to missing configuration.
Also adds basic support for healthd.
The following caveat exists with this placeholder configuration:
- No PSU monitoring (sensors/fans)
- No ASIC temperature monitoring
platform.json is needed for sonic-mgmt testing. Also in the future it will be used as part of dynamic port breakout.
Also removed the folder symlink for BlackhawkDD because it has a different platform.json than BlackhawkO.
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
Need A mmu configuration to get the device going without generating lots of warnings.
Similar to dummy MMU configuration for Arista-7050CX3-32S-C32, this configuration will need to be updated with correct numbers. This MMU configuration is copied from 7060 comparable hwsku.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
- Why I did it
On Arista-7050CX3-32S-C32, there are constant stream of errors like following.
Nov 3 21:56:24.415190 str2-7050cx3-acs-06 NOTICE swss#orchagent: :- registerInWdDb: No lossless TC found on port Ethernet68
Which causes:
loganalyzer to claim test failed.
leaving the system without MMU configuration. Which couldn't be good for any IO test.
- How I did it
Added these MMU configuraions are copied from another platform and guaranteed to be incorrect for hwsku Arista-7050CX3-32S-C32.
Adding them so that we have A MMU configuration and the system won't throw a whole bunch of errors and leave MMU unconfigured. The correct MMU configuration will come later.
This configuration is definitely not suitable for testing system performance or QoS behavior.
Signed-off-by: Ying Xie ying.xie@microsoft.com
- How to verify it
Test will have chance to pass. Ran a few test that would fail otherwise.
- Enable thermalctld support for our platforms
- Fix Chassis.get_num_sfp which had an off by one
- Implement read_eeprom and write_eeprom in SfpBase
- Refactor of Psus and PsuSlots. Psus they are now detected and metadata reported
- Improvements to modular support
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
However in SAI 3.7 default behaviout got changes to 128 Group and 128
Memeber each.
This change is to make sure we are using same ECMP Group/Memeber Per
Group for 3.7 also so that behaviour is consistent.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
as needed by SAI 3.7 and above. Without this change
Warmboot fails from 3.5 to 3.7 as Braodcoam Datastructure
gets corrupted after warm-boot.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
thermalctld throwing error messages because it is not yet fully configured, disabling it for now on arista platforms.
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
* Update arista driver submodule
* Add support for 7260CX3-64E in boot0
* Refactor boot0 platform specific definition
Make it easier to manage new sku
* Add support for 7050CX3-32S in boot0
Just contains the required boot0 information
* Add basic plugin support for DCS-7050CX3-32S
* Add port config for Arista-7050CX3-32S-C32
Co-authored-by: yurypm <yurypm@arista.com>
Co-authored-by: byu343 <byu@arista.com>