Commit Graph

13 Commits

Author SHA1 Message Date
bingwang-ms
b9dd1df372
Update qos config to clear queues for bounced back traffic (#10176)
* Update qos config to clear queues for bounced back traffic

Signed-off-by: bingwang <bingwang@microsoft.com>
2022-04-05 22:32:25 +08:00
gechiang
ddfe87a71a
[BRCMSAI 6.0.0.13-1] Fix Cancun file directory at new location causing TD3 platform boot issue (#9922) 2022-02-07 08:56:06 -08:00
Prince Sunny
d6c3a9308c
[broadcom]: td2/td3 change cpu cos num to 10 (#9301)
bcm_num_cos=10 forces SDK default to map internal priority 0-7 to COS 0. It is now consistent with other SKUs.
2021-11-17 20:56:46 -08:00
gechiang
ef457ab13f
Disable ALPM distributed hitbit thread that is used for debug purpose only but interfered with Other functional operations (#9199) 2021-11-09 07:21:57 -08:00
Ashok Daparthi-Dell
6cbdf11e53
SONIC QOS YANG - Remove qos tables field value refernce format (#7752)
Depends on Azure/sonic-utilities#1626
Depends on Azure/sonic-swss#1754

QOS tables in config db used ABNF format i.e "[TABLE_NAME|name] to refer fieldvalue to other qos tables.

Example:
Config DB:
"Ethernet92|3": {
"scheduler": "[SCHEDULER|scheduler.1]",
"wred_profile": "[WRED_PROFILE|AZURE_LOSSLESS]"
},
"Ethernet0|0": {
"profile": "[BUFFER_PROFILE|ingress_lossy_profile]"
},
"Ethernet0": {
"dscp_to_tc_map": "[DSCP_TO_TC_MAP|AZURE]",
"pfc_enable": "3,4",
"pfc_to_queue_map": "[MAP_PFC_PRIORITY_TO_QUEUE|AZURE]",
"tc_to_pg_map": "[TC_TO_PRIORITY_GROUP_MAP|AZURE]",
"tc_to_queue_map": "[TC_TO_QUEUE_MAP|AZURE]"
},

This format is not consistent with other DB schema followed in sonic.
And also this reference in DB is not required, This is taken care by YANG "leafref".

Removed this format from all platform files to consistent with other sonic db schema.
Example:
"Ethernet92|3": {
"scheduler": "scheduler.1",
"wred_profile": "AZURE_LOSSLESS"
},

Dependent pull requests:
#7752 - To modify platfrom files
#7281 - Yang model
Azure/sonic-utilities#1626 - DB migration
Azure/sonic-swss#1754 - swss change to remove ABNF format
2021-09-28 09:21:24 -07:00
gechiang
6fc279b7c1
Add BRCM SOC Property to not count ACL drops towards interface RX_DRP… (#7945)
* Add BRCM SOC Property to not count ACL drops towards interface RX_DRP counter for 7050CX3 and 7260CX3 DualToR platforms
2021-06-23 18:09:47 -07:00
vmittal-msft
68dfa704b3
Updated Qos/MMU settings for Arista-7050CX3-32S-C32 & Arista-7050CX3-32S-D48C8 (#7068)
* TD3 Qos/MMU settings for Arista-7050CX3-32S-C32 & Arista-7050CX3-32S-D48C8
2021-04-30 10:02:08 -07:00
Prince Sunny
dd4d2a75f0
[Broadcom] Set hierarchical ecmp levels to 2 (#7370)
Set hierarchical ecmp level to 2 instead of 3. Based on CS00011833367, ecmp level must be set to 2.
This is already handled for TH2 platforms. Change is required only for TD3

Co-authored-by: Ubuntu <prsunny@prince-vm.vzw1i4tqyeburcdz5lrgulxi2c.yx.internal.cloudapp.net>
2021-04-21 13:22:52 -07:00
vmittal-msft
02cc486511
Remove dummy MMU profiles for Arista-7050CX3-32S-C32 and Arista-7050CX3-32S-D48C8 (#6785) 2021-02-17 11:45:00 -08:00
gechiang
c98e8d6690
[BCM Config] Update TD3 bcm.config files to use ISSU capable premium CANCUN 6.4.1 (#6651) 2021-02-02 21:48:26 -08:00
Tamer Ahmed
284c2738e8
[sonic-device-data]: Update BRCM Tunnel/ECMP Parameter For 7050cx3 SKUs (#6415)
Update Tunnel and ECMP parameters for brcm 7050cx3 48x50G+8x100G and 32x100G SKUs.

signed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
2021-01-29 14:15:48 -08:00
Ying Xie
1ba583cb46
[TD3] add dummy MMU configuration for Arista-7050CX3-32S-D48C8 (#5950)
Need A mmu configuration to get the device going without generating lots of warnings.

Similar to dummy MMU configuration for Arista-7050CX3-32S-C32, this configuration will need to be updated with correct numbers. This MMU configuration is copied from 7060 comparable hwsku.

Signed-off-by: Ying Xie <ying.xie@microsoft.com>
2020-11-17 19:01:39 -08:00
Samuel Angebault
4ec83b25bc
[arista]: Add new 48x50G + 8x100G hwsku for Lodoga (#5452) 2020-09-23 22:41:07 -07:00