Why I did it
7050 S4Q31 mmu configuration is missing ALPM configurations, causing not enough memory reserved for routes. Orchagent crashes on a nightly testbed with 6400 route entries.
How I did it
Add the missing ALPM configurations.
How to verify it
Load the configuration on testbed and verified new configuration exists and no more crash.
Signed-off-by: Ying Xie ying.xie@microsoft.com
This PR contains the following changes
Original Arista-7050-QX-32S sku (32x40G ports) has been renamed to Arista-7050QX32S-Q32
Arista-7050-QX-32S is symlinked to Arista-7050QX-32S-S4Q31 (4x10G, 31x40G ports)
Signed-off-by: Neetha John <nejo@microsoft.com>
Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
Need proper MMU and Qos settings for Arista-7050QX-32S-S4Q31
How I did it
Updated the settings based on Arista-7050-QX-32S
Why I did it
PG profile settings need to be aligned with Arista-7050-QX-32S
How I did it
Copy over the current settings from Arista-7050-QX-32S and define params for 10G and 1G speeds as well
Signed-off-by: Neetha John <nejo@microsoft.com>
#### Why I did it
- xcvrd crash was seen in latest 201811 images.
- For Dell S6100,API 2.0 uses poll mode while 1.0 was still using interrupt mode.
#### How I did it
- Modified get_transceiver_change_event in 1.0 to poll mode in all the related branches.
Why I did it
To enable autonegotiation/link training on some Broadcom-based platforms (Arista 7060 and 7260, Celestica DX010)
How I did it
Add appropriate SOC property for enabling the feature to the Broadcom config files of appropriate platforms
Also convert line endings to UNIX format for one Celestica file
Why I did it
The S6000 devices, the cold reboot is abrupt and it is likely to cause issues which will cause the device to land into EFI shell. Hence the platform reboot will happen after graceful unmount of all the filesystems as in S6100.
How I did it
Moved the platform_reboot to platform_reboot_override and hooked it to the systemd shutdown services as in S6100.
Fixed the "/host unmount failed" issue as well in 201811.
How to verify it
Issue "reboot" command to verify if the reboot is happening gracefully.
Update fancontrol service for Seastone-DX010/E1031 device to support hysteresis temperature threshold and difference config for each unit fan direction type (B2F/F2B); follow master branch
Dynamic threshold setting changed to 0 and WRED profile green min threshold set to 250000 for Tomahawk devices
Changed the dynamic threshold settings in pg_profile_lookup.ini
Added a macro for WRED profiles in qos.json.j2 for Tomahawk devices
Necessary changes made in qos.config.j2 to use the macro if present
Signed-off-by: Neetha John <nejo@microsoft.com>
* Add new CIG device CS6436-54P and CS5435-54P, also update code for CS6436-56P
* Update port_config.ini
update port config file started from "Ethernet1"
* Update port_config.ini
Update port config file started from "Ethernet1"
* Update port_config.ini
Update the index column in the port config file
* Update sfputil.py
Update sfputil python file as the port index changed
* Update port_config.ini
Update the index column in the port config file
* Update sfputil.py
Update sfputil python file as the port index changed
* Remove the divide by 4 operation to the under the hood SAI
This is to avoid the need and thus the confusion for application program to know
the mmu internal architecture
This change must have support from SAI change to reach the correct
config
Signed-off-by: Wenda <wenni@microsoft.com>
* Relegate the divide by 4 operation to the under the hood SAI for egress
lossless pool
Extend to 7060 and 6100
Signed-off-by: Wenda <wenni@microsoft.com>
* Add more TH/TH2 hwskus
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Update config test
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Add TH2 ingress lossy profile
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Move the divide by 4 operation to SAI internal
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* [bcm SAI] Upgrade Broadcom SAI to version 3.5.3.1-15
- Broadcom SAI 3.5 GA release 20190924.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* add config.bcm for hlx
* modify config.bcm path for hlx
* Delete hx4-cel-hbtn-48x1G+4x10G.config.bcm
* add config.bcm and path
* update led for cxp
* Add new device data for dx010
There is a very low possibility that qsfp_status exists when opening it but doesn't when reading it a bit later. If this occurs an exception is raised.
However, this should be treated as "not presence" rather than causing an exception, which can be achieved by putting it into try block.
* [dell/Z9100] Fix for optics not detected in fanout mode
This commit fixes the issue of optics not detected
error while running sfputil show eeprom command. The root
casuse was the value of port index from port_config.ini for
fan out scenario. The port index should be starting from 0
and not 1. Platform cpld registers are assuming the port
numbers to start from 0 (lowermost bit), sfputils.py uses this
port number in get_presence function. Since the indexing passed
is wrong the optics was not detected and gave SFP EEPROM not
detected message.
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@Dell.com>
* [dell/z9100] Fix for optics not detected in fanout mode
This commit fixes the issue of optics not detected error
while running sfputil show eeprom command. The root cause
was wrong port_index in fan out scenarios. Earlier fix of
changing the port_config.ini is reverted and changes made
in z9100 platform specific sfputil.py file. The port number
is decrement and tested for both 100G and 50G fanout cases.
Tested for the following show commands and test was succesful
show interfaces status, show interfaces transceiver eeprom,
show interfaces transceiver lpmode, show interface tranceiver
presence.
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@Dell.com>
* DellEMC S6000, xcvrd support
* sleep 1 second to avoid busy looping
* removal of dead code
* Correct typo error to 1 second
* Introduced 1 second sleep
* Revamped script with blocking call support
* get_transceiver_change_event api definition update
* adding timeout support for get_transceiver_change_event