What I did:
Updated 7260 MMU Profile based on latest MSFT Tier 1 Tomahawk2_MMU_Setting_48x100G_40m_16x100G_300m_v1.0 and
TH2_PGHdrm_MSFT.
How I verify:
Made sure image is up/traffic is flowing/mmu dump looked fine.
SAI qos test need will be updated to support this SKU.
* [202012] Add SOC property to enable AN/LT on some platforms
Why I did it
To enable autonegotiation/link training on some Broadcom-based platforms (Arista 7060CX, 7260CX3, 7050cx3, Celestica DX010)
How I did it
Add appropriate SOC property for enabling the feature to the Broadcom config files of appropriate platforms
Also convert line endings to UNIX format for one Celestica file
* Add 'phy_an_lt_msft' to BCM config file permitted list
* 7260cx3 DualToR config.bcm support based on DualToR setting in device metadata at boot time.
For HWSKU Arista-7260CX3-C64 the MMU setting SOC for T0/T1 is also combined into the config.bcm.j2 logic so use just one config file and adding delta based on Switch Roles.
However in SAI 3.7 default behaviout got changes to 128 Group and 128
Memeber each.
This change is to make sure we are using same ECMP Group/Memeber Per
Group for 3.7 also so that behaviour is consistent.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
as needed by SAI 3.7 and above. Without this change
Warmboot fails from 3.5 to 3.7 as Braodcoam Datastructure
gets corrupted after warm-boot.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
* [Device] Rename SKU Arista-7260CX3-64 to Arista-7260CX3-C64
Renaming to add the speed indication: C64 means 64 100G ports.
renamed: Arista-7260CX3-64/port_config.ini -> Arista-7260CX3-C64/port_config.ini
renamed: Arista-7260CX3-64/sai.profile -> Arista-7260CX3-C64/sai.profile
* [Arista-7260cx3] Fix 64x100G port_config.ini
Reorder the port lanes to match the front panel port numbering.
* [Arista-7260CX3] add hwSKU Arista-7260CX3-D108C8
This hwSKU has 108x50G ports and 8x100G ports (2 x 100G ports are unused)