* Improve memory utilization through more sharing at the ingress on A7050-QX-32S
Signed-off-by: Wenda <wenni@microsoft.com>
* Apply buffers config changes on A7050-QX-32S to A7050-QX32
Signed-off-by: Wenda <wenni@microsoft.com>
* Apply buffers config changes on A7050-QX-32S to S6000
Just a simple change to make sonic's user life a little bit easier. Displaying the multiple elements of config_db.json in an orderly fashion allows a more intuitive user-experience.
For this change i'm simply intercepting the config-state that is about to be dumped to config_db.json, and i'm placing it in an ordered-dictionary, so that information is pushed to file in natural/alphanumerical ordering.
Example:
admin@lnos-x1-a-csw01:~$ sudo sonic-cfggen -m /etc/sonic/minigraph.xml --print-data
{
...
"PORT": {
"Ethernet0": {
"alias": "Eth1/1",
"lanes": "65"
},
"Ethernet1": {
"alias": "Eth1/2",
"lanes": "66"
},
"Ethernet2": {
"alias": "Eth1/3",
"lanes": "67"
},
"Ethernet3": {
"alias": "Eth1/4",
"lanes": "68"
},
"Ethernet4": {
"alias": "Eth2/1",
"lanes": "69"
},
...
...
"INTERFACE": {
"Ethernet0|10.0.0.0/31": {},
"Ethernet1|10.0.0.2/31": {},
"Ethernet2|10.0.0.4/31": {},
"Ethernet3|10.0.0.6/31": {},
"Ethernet4|10.0.0.8/31": {},
- Service unit file not getting generated because I changed the docker
container name from 'router_advertiser' to 'radv', however I didn't
rename the service unit file template name to match. However,
slave.mk generates a service file for every docker based on its
container name, and since there was no matching 'radv.service.j2'
template file, this file stopped getting generated and therefore
the docker container was never getting started.
- Also add swss.service to 'Requires'
- Move all minigraph-related action from rc.local to updategraph
- updategraph service is now after database. All feature services are now after and depending on updategraph
* Support OS9 -> SONiC fast-reboot migration
* Address review comments. Update NOS mac in EEPROM and net.rules for eth0
* Address review comments. Update sonic-platform-modules-dell to fac81d...
* Fix script for POSIX compliance
* Add psuutil for S8900-54XC and S8900-64XC.
* Update syseeprom to CPU EEPROM for S9130-32X, S9200-64X and S9230-64X.
* Update sensors.conf for S9200-64X and S9230-64X.
* Update submodule for platform/broadcom/sonic-platform-modules-ingrasys
Signed-off-by: Wade He <chihen.he@gmail.com>
Now properly differenciate the image installation and the kexec
operations. This is useful for fast-reboot operations.
Minor updates include
- better command line management
- using partition UUID in the command line
This commit adds new code which supports the new buffer mgmt infra.
- Added new code to support buffers for T0 and T1 configs of S6100.
- Added new qos.json file to support qos on S6100.
- Changed the pg_profile_lookup.ini file to support xon_offset.
- Changed buffer.json.j2 file according to new buffer mgmt infra.
Unit tested by verifying the above changes by loading S6100 with the
configuration, checked the hardware for broadcom recommended settings
by running bcmcmd. Sent the unit test logs to Ying.
Checked the PG_RESET_OFFSET value which reflects the new xon_offset value of 2288
from the pg_profile_lookup.ini.
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@dell.com>
* Add qos.json for Arista-7050-QX-32S
This file is a modification from the one in the swss docker, and is applied in the base image
Signed-off-by: Wenda <wenni@microsoft.com>
* Prepare buffers.json.j2 alongside with qos.json to allow qos config to take
effect on a7050-QX-32S
Signed-off-by: Wenda <wenni@microsoft.com>
* [sonic build] Define folder macro for target folder /usr/sonic/share/templates
* [sonic-cfggen] allow templates to include from common folders
- Allow templates to include files under /usr/share/sonic/templates
- Allow templates to include files in the same folder as the root template
* [Buffer config] install the buffer configuration template
* [Arista7260cx3] Add buffer configuration for Arista7260CX3 T0 topology
- pg profile look up table is incomplete. Currently contains T0 default
values.
* [Arista7260cx3] Adding QoS configuration
* Address review comments
1. Stop generating ingress pg configuration for lossless pgs.
2. Stop putting ports into speed sets, put all ports in one set.
3. Remove ingress lossless profiles.
4. Added some tailing '-' back to remove leading spaces.
- Adds the following changes:
- [schema] Update Config DB Table name #defines (#188)
- Extending IpAddress class with method to return the scope of any
given ip-address (#187)
- Extending IpPrefix class to return the subnet associated to any
given prefix (#184)
- update build instruction (#185)