1. BRCM SAI Debian build need not have any Kernel version dependency - Starting with 4.3 BRCM made changes in SAI so that this dependency has been cleaned up. We can now remove the Kernel Version dependency from Azure Pipeline build script.
2. Bypass PEER_MODE p2mp setting causing SYNCd crash on non-TD3 SKUs - Temporarily patch BRCM SAI code to not cause SYNCd crash when Orchagent program SAI_TUNNEL_ATTR_PEER_MODE: SAI_TUNNEL_PEER_MODE_P2MP on Non-TD3 SKUs. Will remove this when BRCM provide proper fix to address this issue.
- Why I did it
Fix issue: ptf_nn_agent isn't able to start in syncd-rpc docker on buster.
- How I did it
The issue is fixed by installing python-dev, cffi and nnpy for python 2 explicitly.
- How to verify it
Run copp test on RPC image.
**- Why I did it**
In thermalctd, when speed of fan exceeds threshold, the fan status will be saved as "bad". So in system health, it is better to check fan speed before fan status. In this case, if fan speed exceeds threshold, we get more detailed information.
**- How I did it**
Move fan speed check logic before fan status check
**- How to verify it**
Manual test
BRCM SDK 6.5.21 includes firmware updates (premier cancun) for TD3 platforms. The firmware update is required on TD3 platforms, which is packaged with BCMSAI 4.3.0.10.
**- How I did it**
Updated BCM config with a new variable that specifies the firmware package path. SDK uses this path to locate firmware packages and load during cold boot.
**- How to verify it**
bsv
BRCM SAI ver: [4.3.0.10], OCP SAI ver: [1.7.1], SDK ver: [sdk-6.5.21] CANCUN ver: [5.3.3]
drivshell>
admin@str2-7050cx3-acs-02:~$ bcmsh
Press Enter to show prompt.
Press Ctrl+C to exit.
NOTICE: Only one bcmsh or bcmcmd can connect to the shell at same time.
drivshell>cancun stat
cancun stat
UNIT0 CANCUN:
CIH: LOADED
Ver: 06.06.01
CMH: LOADED
Ver: 06.06.01
SDK Ver: 06.05.21
CCH: LOADED
Ver: 06.06.01
SDK Ver: 06.05.21
CEH: LOADED
Ver: 06.06.01
SDK Ver: 06.05.21
drivshell>
Starting with BRCM SAI 4.3.1.5 we see the following :ethtool not fount" error in syslog during boot up:
```
Jan 27 07:36:14.712472 str-s6100-acs-1 INFO syncd#/supervisord: syncd sh: 1:
Jan 27 07:36:14.712844 str-s6100-acs-1 INFO syncd#/supervisord: syncd ethtool: not found
Jan 27 07:36:14.713228 str-s6100-acs-1 INFO syncd#/supervisord: syncd #015
Jan 27 07:36:14.713840 str-s6100-acs-1 INFO syncd#syncd: [0] SAI_API_HOSTIF:_brcm_sai_hostif_speed_set:11894 cmd ethtool -s Ethernet39 speed 40000 rc:32512
Jan 27 07:36:14.717204 str-s6100-acs-1 NOTICE swss#orchagent: :- setHostIntfsOperStatus: Set operation status DOWN to host interface Ethernet39
Jan 27 07:36:14.717204 str-s6100-acs-1 NOTICE swss#orchagent: :- initPort: Initialized port Ethernet39
Jan 27 07:36:14.717204 str-s6100-acs-1 NOTICE swss#orchagent: :- initializePort: Initializing port alias:Ethernet36 pid:1000000000040
Jan 27 07:36:14.726793 str-s6100-acs-1 NOTICE swss#portsyncd: :- onMsg: nlmsg type:16 key:Ethernet36 admin:0 oper:0 addr:4c:76:25:f5:48:80 ifindex:75 master:0
Jan 27 07:36:14.727967 str-s6100-acs-1 NOTICE swss#portsyncd: :- onMsg: Publish Ethernet36(ok) to state db
Jan 27 07:36:14.729331 str-s6100-acs-1 NOTICE swss#orchagent: :- addHostIntfs: Create host interface for port Ethernet36
Jan 27 07:36:14.752398 str-s6100-acs-1 INFO syncd#/supervisord: syncd sh: 1: ethtool: not found#015
Jan 27 07:36:14.752689 str-s6100-acs-1 INFO syncd#syncd: [0] SAI_API_HOSTIF:_brcm_sai_hostif_speed_set:11894 cmd ethtool -s Ethernet36 speed 40000 rc:32512
Jan 27 07:36:14.756050 str-s6100-acs-1 NOTICE swss#orchagent: :- setHostIntfsOperStatus: Set operation status DOWN to host interface Ethernet36
Jan 27 07:36:14.757585 str-s6100-acs-1 NOTICE swss#orchagent: :- initPort: Initialized port Ethernet36
```
It seems that starting with BRCM SAI 4.2.1.5 syncd is using ethtool to set the host interface speed and since this ethtool was not part of the syncd Docker, we observe these "ethtool not found" issue.
This update includes the following changes
> [syncd armhf] Fix syncd crash when running community test suites (#777)
> Revert "[tests]:Add unittest for MACsec on p2p establishment (#771)"
> [tests]:Add unittest for MACsec on p2p establishment (#771)
> [tests] Enable azure pipeline make check to respect unittests (#760)
**- Why I did it**
As per https://pypi.org/project/pip/ pip 21.0 does not not support Python 2 from Jan 2021. Most places in the codebase have already been pinned, but this one was missed.
**- How I did it**
Pin pip2 < version 21 in build_debian.sh
fixesAzure/sonic-utilities#1389
With the recent changes in sudoer files. The show commands fails for the read-only users.
The problem here is the 'docker ps' is failing in the function [get_routing_stack()](8a1109ed30/show/main.py (L54)) therefore all the CLI commands are failing.
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
- Why I did it
The command sudo ip netns identify <pid> is used in function get_current_namespace
to check in the cli command is running in host context or within a namespace.
This function is used for every CLI command and command sudo ip netns identify <pid> needs to be added in sudoer files to allow users with RO access to run show cli commands
This problem is not there on single asic platforms.
- How I did it
Add ip netns identify [0-9]* to sudoers file.
**- Why I did it**
sonic-utilities will become dependent upon sonic-platform-common as of https://github.com/Azure/sonic-utilities/pull/1386.
**- How I did it**
- Add sonic-platform-common as a dependency in docker-sonic-vs.mk
- Additionally, no longer install Python 2 packages of swsssdk and sonic-py-common, as they should no longer be needed.
Some commands used during build will prompt user interactively, but this is not expected during build. Since most output is collected into log file, user could not see the prompt and feel the build process hangs.
- How I did it
Use mv command in non interactive mode
Redirect stdin to null if command output is collected into log file.
azure pipepline does not allow upload same artifacts again.
thus, use job.attempt to uniquely name the test artifacts
Signed-off-by: Guohan Lu <lguohan@gmail.com>
The requirement for zebra to be ready to accept connections is a generic problem that is not
specific to bgpd. Making the script to wait for zebra socket a separate script and let bgpd and
staticd to wait for zebra socket.
Changes in the new release:
1. Policy based hashing optimization
2. New attribute support for Max port headroom
3. Tunnel ECN map fixes
4. Tunnel EVPN skeleton extensions (peer attrib, maps)
5. Bridge port admin not affecting port admin (optimize port down time)
6. CRM new API for neighbors and tunnel termination entries
7. Improve FDB event for flush by bridge port (before, null bridge was reported to SONiC, now the bridge will be extracted from bridge port)
8. DHCP L2 v4+v6 traps (for ZTP use case)
9. Generic counter implementation
Signed-off-by: Kebo Liu <kebol@nvidia.com>
This commit fixes a typo in the fix delivered in PR #6538
syncd fails on the armhf platform within sonic-config-engine/portconfig.py when importing the following
'from swsscommon.swsscommon import ConfigDBConnector'
Following changes were done for ebtables:
- Support for Multi-asic platforms. Ebtable filters are installed in namespace for multi-asic and not host. On Single asic installed on host.
- For Multi-asic platforms we don't want to install on host otherwise Namespace-to-Namespace communication does not happens since ARP Request are not forwarded.
- Updated to use text file to restore ebtables rules then the binary format. Rules are restore as part of Database docker init instead of rc.local
- Removed the ebtable service files for buster as not needed as filters are restored/installed as part of database docker init.
All the binaries are pre-installed with ebtables* binary are same as ebatbles-legacy-*
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
- combine docker-ptf-saithrift into docker-ptf docker
- build docker-ptf under platform vs
- remove docker-ptf for other platforms
Signed-off-by: Guohan Lu <lguohan@gmail.com>
During ISSU, "mlxsw_minimal" driver still trying to access firmware, in some cases FW could return some wrong critical threshold value which will cause switch shutdown.
**- How I did it**
In order to prevent "mlxsw_minimal" driver from accessing ASIC during ISSU, SDK will raise "OFFLINE" 'udev' event
at the early beginning of such flow. When this event is received, hw-management will remove "mlxsw_minimal" driver.
There is no need to implement the opposite "ONLINE" event since this flow is ended up with "kexec".
**- How to verify it**
repeatedly perform warm reboot, make sure there is no switch shutdown occurred.
* Fix exception in bgpmon caused by duplicate keys
It is possible that BGP neighbors in IPv4 and IPv6 address families
share the same name (such as bgp monitor). However, such case is not
handled in bgpmon, and an Exception will be raised. This commit will
address the issue by Using set instead of list to avoid duplicate keys.
this is due to command line change in
1e12790a93
this is due to command line change in
Azure/sonic-mgmt@1e12790
Signed-off-by: Guohan Lu <lguohan@gmail.com>
reset the owner for all files under working directory. some files were owned by root after build, which cause
next build to fail since directory cannot be cleanned.
Signed-off-by: Guohan Lu <lguohan@gmail.com>
Bugs fixes:
All | Kernel | During system reload when CPU is loaded with heavy traffic, a Kernel Panic may occur.
All | Modules, Port split | FW stuck when device rebooted with locked Optical Transceivers in split mode
Spectrum-3 | PFC | On Spectrum-3 systems, slow reaction time to Rx pause packets on 40GbE ports may lead to buffer overflow on servers.
Spectrum-3 | SN4700, Port Split | On rare occasion SN4700, conducting 100G split (4x25G) in NRZ when splitter port 1 or 2 are down, ports 3 and 4 will also go down.
Enahncments:
All | Kernel | new notification on ISSU start, so other kernel drivers can disable any interface to ASIC
Signed-off-by: Kebo Liu <kebol@nvidia.com>
Recent changes brought l2 vlan concept which do not have DHCP
clients behind them and so DHCP relay is not required. Also,
dhcpmon fails to launch on those vlans as their interfaces
lack IP addresses. This PR limit launch of both DHCP relay
and dhcpmon to L3 vlans only.
singed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
Check #6483
add test to make sure default route change in eth0 does not
affect the default route in the default vrf
Signed-off-by: Guohan Lu <lguohan@gmail.com>
- Support for non-template based FRR configurations (BGP, route-map, OSPF, static route..etc) using config DB schema.
- Support for save & restore - Jinja template based config-DB data read and apply to FRR during startup
**- How I did it**
- add frrcfgd service
- when frr_mgmg_framework_config is set, frrcfgd starts in bgp container
- when user changed the BGP or other related table entries in config DB, frrcfgd will run corresponding VTYSH commands to program on FRR.
- add jinja template to generate FRR config file to be used by FRR daemons while bgp container restarted
**- How to verify it**
1. Add/delete data on config DB and then run VTYSH "show running-config" command to check if FRR configuration changed.
1. Restart bgp container and check if generated FRR config file is correct and run VTYSH "show running-config" command to check if FRR configuration is consistent with attributes in config DB
Co-authored-by: Zhenhong Zhao <zhenhong.zhao@dell.com>
**- Why I did it**
For now `hwsku.json` and `platform.json` dont support optional fields. For example no way to add `fec` or `autoneg` field using `platform.json` and `hwsku.json`.
**- How I did it**
Added parsing of optional fields from hwsku.json.
**- How to verify it**
Add optional field to `hwsku.json`. After first boot will be generated new `config_db.json` or you can generate it using `sonic-cfggen` command. In this file must be optional field from `hwsku.json` or check using command `redis-cli hgetall PORT_TABLE:Ethernet0`
Example of `hwsku.json`, that must be parsed:
```
{
"interfaces": {
"Ethernet0": {
"default_brkout_mode": "1x100G[40G]",
"fec": "rs",
"autoneg": "0"
},
...
}
```
Example of generated `config_db.json`:
```
"PORT": {
"Ethernet0": {
"alias": "Ethernet0",
"lanes": "0,1,2,3",
"speed": "100000",
"index": "1",
"admin_status": "up",
"fec": "rs",
"autoneg": "0",
"mtu": "9100"
},
```
So, we can see this entries in redis db:
```
admin@sonic:~$ redis-cli hgetall PORT_TABLE:Ethernet0
1) "alias"
2) "Ethernet0"
3) "lanes"
4) "0,1,2,3"
5) "speed"
6) "100000"
7) "index"
8) "1"
9) "admin_status"
10) "up"
11) "fec"
12) "rs"
13) "autoneg"
14) "0"
15) "mtu"
16) "9100"
17) "description"
18) ""
19) "oper_status"
20) "up"
```
Also its way to fix `show interface status`, `FEC` field but also need add `FEC` field to `hwsku.json`.
Before:
```
admin@sonic:~$ show interfaces status
Interface Lanes Speed MTU FEC Alias Vlan Oper Admin Type Asym PFC
----------- --------------- ------- ----- ----- ----------- ------ ------ ------- --------------- ----------
Ethernet0 0,1,2,3 100G 9100 N/A Ethernet0 routed up up QSFP28 or later N/A
```
After:
```
admin@sonic:~$ show interfaces status
Interface Lanes Speed MTU FEC Alias Vlan Oper Admin Type Asym PFC
----------- --------------- ------- ----- ----- ----------- ------ ------ ------- --------------- ----------
Ethernet0 0,1,2,3 100G 9100 rs Ethernet0 routed up up QSFP28 or later N/A
```