Why I did it
To fix ecmp hash polarization issue.
Work item tracking
Microsoft ADO (number only): 26085143
How I did it
Add sai_hash_seed_config_hash_offset_enable=1 in all config.bcm that Broadcom T1 uses.
HardwareSku
Force10-S6100-T1
Force10-S6100-ITPAC-T1
Force10-S6100
Celestica-DX010-C32
Arista-7260CX3-C64
Arista-7060CX-32S-Q32
Arista-7060CX-32S-C32-T1
Arista-7060CX-32S-C32
Arista-7050QX32S-Q32
Arista-7050QX-32S-S4Q31
Arista-7050-QX32
Arista-7050-QX-32SInclude Broadcom's fix by upgrading xgs SAI version to 8.4.35.0.
8.4.35.0: [CSP 00012324019] back-porting SONIC-75006 to SAI8.4
8.4.34.0:
[CSP 00012318293] back-porting SONIC-81534 to SAI8.4;
ECMP LB traffic polarization, configure hash_offset along with hash_seed attr
Run qual with only xgs SAI version upgraded to 8.4.35.0:
on TH2: https://elastictest.org/scheduler/testplan/6579b36ccfacd86e78e3e885?leftSideViewMode=detail&prop=status&order=ascending
on TH: https://elastictest.org/scheduler/testplan/657a75f8c1d3b51fc1d585b4?leftSideViewMode=detail&prop=status&order=ascending
How to verify it
use tests/ecmp/test_ecmp_sai_value.py to verify.
Depends on Azure/sonic-utilities#1626
Depends on Azure/sonic-swss#1754
QOS tables in config db used ABNF format i.e "[TABLE_NAME|name] to refer fieldvalue to other qos tables.
Example:
Config DB:
"Ethernet92|3": {
"scheduler": "[SCHEDULER|scheduler.1]",
"wred_profile": "[WRED_PROFILE|AZURE_LOSSLESS]"
},
"Ethernet0|0": {
"profile": "[BUFFER_PROFILE|ingress_lossy_profile]"
},
"Ethernet0": {
"dscp_to_tc_map": "[DSCP_TO_TC_MAP|AZURE]",
"pfc_enable": "3,4",
"pfc_to_queue_map": "[MAP_PFC_PRIORITY_TO_QUEUE|AZURE]",
"tc_to_pg_map": "[TC_TO_PRIORITY_GROUP_MAP|AZURE]",
"tc_to_queue_map": "[TC_TO_QUEUE_MAP|AZURE]"
},
This format is not consistent with other DB schema followed in sonic.
And also this reference in DB is not required, This is taken care by YANG "leafref".
Removed this format from all platform files to consistent with other sonic db schema.
Example:
"Ethernet92|3": {
"scheduler": "scheduler.1",
"wred_profile": "AZURE_LOSSLESS"
},
Dependent pull requests:
#7752 - To modify platfrom files
#7281 - Yang model
Azure/sonic-utilities#1626 - DB migration
Azure/sonic-swss#1754 - swss change to remove ABNF format
Treat devices that are ToRRouters (ToRRouters and BackEndToRRouters) the same when rendering templates
Except for BackEndToRRouters belonging to a storage cluster, since these devices have extra sub-interfaces created
Treat devices that are LeafRouters (LeafRouters and BackEndLeafRouters) the same when rendering templates
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
However in SAI 3.7 default behaviout got changes to 128 Group and 128
Memeber each.
This change is to make sure we are using same ECMP Group/Memeber Per
Group for 3.7 also so that behaviour is consistent.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
Dynamic threshold setting changed to 0 and WRED profile green min threshold set to 250000 for Tomahawk devices
Changed the dynamic threshold settings in pg_profile_lookup.ini
Added a macro for WRED profiles in qos.json.j2 for Tomahawk devices
Necessary changes made in qos.config.j2 to use the macro if present
Signed-off-by: Neetha John <nejo@microsoft.com>
* Remove the divide by 4 operation to the under the hood SAI
This is to avoid the need and thus the confusion for application program to know
the mmu internal architecture
This change must have support from SAI change to reach the correct
config
Signed-off-by: Wenda <wenni@microsoft.com>
* Relegate the divide by 4 operation to the under the hood SAI for egress
lossless pool
Extend to 7060 and 6100
Signed-off-by: Wenda <wenni@microsoft.com>
* Add more TH/TH2 hwskus
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Update config test
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Add TH2 ingress lossy profile
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Move the divide by 4 operation to SAI internal
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* [bcm SAI] Upgrade Broadcom SAI to version 3.5.3.1-15
- Broadcom SAI 3.5 GA release 20190924.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* add config.bcm for hlx
* modify config.bcm path for hlx
* Delete hx4-cel-hbtn-48x1G+4x10G.config.bcm
* add config.bcm and path
* update led for cxp
* Add new device data for dx010