# libsensors configuration file for DCS-7260CX3-64
# ------------------------------------------------#
bus "i2c-1" "SCD 0000:06:00.0 SMBus master 0 bus 0"
bus "i2c-3" "SCD 0000:06:00.0 SMBus master 0 bus 2"
bus "i2c-4" "SCD 0000:06:00.0 SMBus master 0 bus 3"
bus "i2c-73" "SCD 0000:ff:0b.3 SMBus master 0 bus 0"
bus "i2c-88" "SCD 0000:ff:0b.3 SMBus master 3 bus 3"
chip "max6658-i2c-1-4c"
label temp1 "Asic temp sensor"
set temp1_max 65
set temp1_crit 75
ignore temp2
chip "pmbus-i2c-3-58"
label temp1 "Power supply 1 hotspot sensor"
label temp2 "Power supply 1 inlet temp sensor"
label temp3 "Power supply 1 exhaust temp sensor"
# setting maximum and critical thresholds is not supported for this psu
# fault and warning limits defined internally by hardware
ignore fan2
ignore fan3
chip "pmbus-i2c-4-58"
label temp1 "Power supply 2 hotspot sensor"
label temp2 "Power supply 2 inlet temp sensor"
label temp3 "Power supply 2 exhaust temp sensor"
# setting maximum and critical thresholds is not supported for this psu
# fault and warning limits defined internally by hardware
ignore fan2
ignore fan3
chip "max6658-i2c-73-4c"
label temp1 "Back panel temp sensor 1"
label temp2 "Back panel temp sensor 2"
set temp1_max 65
set temp1_crit 75
set temp2_max 65
set temp2_crit 75
chip "lm73-i2c-88-48"
label temp1 "Front panel temp sensor"
set temp1_max 65
set temp1_crit 75