b0b0ba828a
Why I did it Added support for the device N3248PXE How I did it Implemented the support for the platform N3248PXE n3248pxe_unit_test_log.txt Switch Vendor: DellEMC * Switch SKU: N3248PXE * ASIC Vendor: Broadcom * SONiC Image: sonic-broadcom.bin How to verify it Verified the show platform commands
192 lines
6.4 KiB
Python
192 lines
6.4 KiB
Python
#
|
|
# psuutil.py
|
|
# Platform-specific PSU status interface for SONiC
|
|
#
|
|
|
|
import commands
|
|
import os
|
|
import sys
|
|
|
|
SENSORS_CMD = "docker exec -i pmon /usr/bin/sensors"
|
|
DOCKER_SENSORS_CMD = "/usr/bin/sensors"
|
|
|
|
try:
|
|
from sonic_psu.psu_base import PsuBase
|
|
except ImportError as e:
|
|
raise ImportError(str(e) + "- required module not found")
|
|
|
|
|
|
class PsuUtil(PsuBase):
|
|
"""Platform-specific PSUutil class"""
|
|
_psu_mapping = {
|
|
1 : '0',
|
|
2 : '1'
|
|
}
|
|
|
|
def __init__(self):
|
|
PsuBase.__init__(self)
|
|
|
|
def isDockerEnv(self):
|
|
num_docker = open('/proc/self/cgroup', 'r').read().count(":/docker")
|
|
if num_docker > 0:
|
|
return True
|
|
else:
|
|
return False
|
|
|
|
def remove_nonnumeric(self, text):
|
|
digits='0123456789.'
|
|
return ''.join(c for c in text if c in digits)
|
|
|
|
def get_cpld_register(self, reg_name):
|
|
cpld_dir = "/sys/devices/platform/dell-n3248pxe-cpld.0/"
|
|
retval = 'ERR'
|
|
reg_file = cpld_dir +'/' + reg_name
|
|
if (not os.path.isfile(reg_file)):
|
|
return retval
|
|
|
|
try:
|
|
with open(reg_file, 'r') as fd:
|
|
retval = fd.read()
|
|
except Exception:
|
|
print("Unable to open ", reg_file, "file !")
|
|
|
|
retval = retval.rstrip('\r\n')
|
|
return retval
|
|
|
|
def get_num_psus(self):
|
|
"""
|
|
Retrieves the number of PSUs available on the device
|
|
:return: An integer, the number of PSUs available on the device
|
|
"""
|
|
N3248PXE_MAX_PSUS = 2
|
|
return N3248PXE_MAX_PSUS
|
|
|
|
def get_psu_status(self, index):
|
|
"""
|
|
Retrieves the oprational status of power supply unit (PSU) defined
|
|
by index <index>
|
|
:param index: An integer, index of the PSU of which to query status
|
|
:return: Boolean, True if PSU is operating properly, False if PSU is\
|
|
faulty
|
|
"""
|
|
status = 0
|
|
psu_status = self.get_cpld_register('psu'+self._psu_mapping[index]+'_status')
|
|
if (psu_status != 'ERR'):
|
|
status = int(psu_status, 10)
|
|
|
|
presence = self.get_psu_presence(index)
|
|
|
|
return (status & presence)
|
|
|
|
def get_psu_presence(self, index):
|
|
"""
|
|
Retrieves the presence status of power supply unit (PSU) defined
|
|
by index <index>
|
|
:param index: An integer, index of the PSU of which to query status
|
|
:return: Boolean, True if PSU is plugged, False if not
|
|
"""
|
|
status = 0
|
|
psu_presence = self.get_cpld_register('psu'+self._psu_mapping[index]+'_prs')
|
|
if (psu_presence != 'ERR'):
|
|
status = int(psu_presence, 10)
|
|
|
|
return status
|
|
|
|
def get_sensor(self):
|
|
dockerenv = self.isDockerEnv()
|
|
if not dockerenv:
|
|
status, cmd_output = commands.getstatusoutput(SENSORS_CMD)
|
|
else :
|
|
status, cmd_output = commands.getstatusoutput(DOCKER_SENSORS_CMD)
|
|
|
|
if status:
|
|
print('Failed to execute sensors command')
|
|
sys.exit(0)
|
|
return cmd_output
|
|
|
|
def get_output_current(self, index):
|
|
cmd_output= self.get_sensor()
|
|
sensor_name = 'dps460-i2c-10' if index == 1 else 'dps460-i2c-11'
|
|
found = False
|
|
for line in cmd_output.splitlines():
|
|
if line.startswith(sensor_name):
|
|
found = True
|
|
if found:
|
|
if 'Output Current' in line :
|
|
return float(self.remove_nonnumeric(line.split()[2]))
|
|
return 0.0
|
|
|
|
def get_output_voltage(self, index):
|
|
cmd_output= self.get_sensor()
|
|
sensor_name = 'dps460-i2c-10' if index == 1 else 'dps460-i2c-11'
|
|
found = False
|
|
for line in cmd_output.splitlines():
|
|
if line.startswith(sensor_name):
|
|
found = True
|
|
if found:
|
|
if 'Output Voltage' in line :
|
|
return float(self.remove_nonnumeric(line.split()[2]))
|
|
return 0.0
|
|
|
|
def get_fan_rpm(self, index, fan_index):
|
|
if fan_index > 1 : return 0.0
|
|
cmd_output= self.get_sensor()
|
|
sensor_name = 'dps460-i2c-10' if index == 1 else 'dps460-i2c-11'
|
|
found = False
|
|
for line in cmd_output.splitlines():
|
|
if line.startswith(sensor_name):
|
|
found = True
|
|
if found:
|
|
if 'Fan RPM' in line :
|
|
return self.remove_nonnumeric(line.split()[2])
|
|
return 0.0
|
|
|
|
def get_output_power(self, index):
|
|
cmd_output= self.get_sensor()
|
|
sensor_name = 'dps460-i2c-10' if index == 1 else 'dps460-i2c-11'
|
|
found = False
|
|
for line in cmd_output.splitlines():
|
|
if line.startswith(sensor_name):
|
|
found = True
|
|
if found:
|
|
if 'Output Power' in line :
|
|
return float(self.remove_nonnumeric(line.split()[2]))
|
|
return 0.0
|
|
|
|
def get_direction(self, index):
|
|
psuid = '0' if index == 1 else '1'
|
|
sysfs_path = '/sys/devices/platform/dell-n3248pxe-cpld.0/psu' + psuid + '_prs'
|
|
found_psu = int(open(sysfs_path).read())
|
|
if not found_psu : return ''
|
|
bus_no = '10' if index == 1 else '11'
|
|
sysfs_path = "/sys/bus/i2c/devices/" + bus_no + "-0056/eeprom"
|
|
val = (open(sysfs_path, "rb").read())[0xe1:0xe8]
|
|
dir = 'F2B' if 'FORWARD' == val else 'B2F'
|
|
return dir
|
|
|
|
def get_serial(self, index):
|
|
psuid = '0' if index == 1 else '1'
|
|
sysfs_path = '/sys/devices/platform/dell-n3248pxe-cpld.0/psu' + psuid + '_prs'
|
|
found_psu = int(open(sysfs_path).read())
|
|
if not found_psu : return ''
|
|
bus_no = '10' if index == 1 else '11'
|
|
sysfs_path = "/sys/bus/i2c/devices/" + bus_no + "-0056/eeprom"
|
|
val = (open(sysfs_path, "rb").read())[0xc4:0xd9]
|
|
return val
|
|
|
|
def get_model(self, index):
|
|
psuid = '0' if index == 1 else '1'
|
|
sysfs_path = '/sys/devices/platform/dell-n3248pxe-cpld.0/psu' + psuid + '_prs'
|
|
found_psu = int(open(sysfs_path).read())
|
|
if not found_psu : return ''
|
|
bus_no = '10' if index == 1 else '11'
|
|
sysfs_path = "/sys/bus/i2c/devices/" + bus_no + "-0056/eeprom"
|
|
val = (open(sysfs_path, "rb").read())[0x50:0x62]
|
|
return val
|
|
|
|
def get_mfr_id(self, index):
|
|
psuid = '0' if index == 1 else '1'
|
|
sysfs_path = '/sys/devices/platform/dell-n3248pxe-cpld.0/psu' + psuid + '_prs'
|
|
found_psu = int(open(sysfs_path).read())
|
|
return 'DELTA' if found_psu else ''
|