a582c13e98
Add new platform x86_64-ruijie_b6510-48vs8cq-r0 (Trident 3) ASIC Vendor: Broadcom Switch ASIC: Trident 3 Port Config: 48x25G+8x100G Signed-off-by: tim-rj <sonic_rd@ruijie.com.cn>
839 lines
33 KiB
Python
Executable File
839 lines
33 KiB
Python
Executable File
#!/usr/bin/env python3
|
|
# -*- coding: UTF-8 -*-
|
|
import click
|
|
import os
|
|
import time
|
|
import syslog
|
|
from ruijieconfig import MONITOR_CONST, FANCTROLDEBUG, MONITOR_FANS_LED, DEV_LEDS, MONITOR_PSU_STATUS, \
|
|
MONITOR_SYS_PSU_LED, MONITOR_DEV_STATUS, MONITOR_FAN_STATUS, MONITOR_DEV_STATUS_DECODE, \
|
|
MONITOR_SYS_FAN_LED, MONITOR_SYS_LED, fanloc
|
|
|
|
from ruijieutil import rji2cget, getMacTemp_sysfs, write_sysfs_value, get_sysfs_value, strtoint, \
|
|
rji2cset
|
|
|
|
import traceback
|
|
import glob
|
|
|
|
|
|
CONTEXT_SETTINGS = dict(help_option_names=['-h', '--help'])
|
|
|
|
DEBUG_COMMON = 0x01
|
|
DEBUG_LEDCONTROL = 0x02
|
|
DEBUG_FANCONTROL = 0x04
|
|
|
|
|
|
class AliasedGroup(click.Group):
|
|
def get_command(self, ctx, cmd_name):
|
|
rv = click.Group.get_command(self, ctx, cmd_name)
|
|
if rv is not None:
|
|
return rv
|
|
matches = [x for x in self.list_commands(ctx)
|
|
if x.startswith(cmd_name)]
|
|
if not matches:
|
|
return None
|
|
elif len(matches) == 1:
|
|
return click.Group.get_command(self, ctx, matches[0])
|
|
ctx.fail('Too many matches: %s' % ', '.join(sorted(matches)))
|
|
|
|
def fanwarninglog(s):
|
|
#s = s.decode('utf-8').encode('gb2312')
|
|
syslog.openlog("FANCONTROL",syslog.LOG_PID)
|
|
syslog.syslog(syslog.LOG_WARNING,s)
|
|
|
|
def fancriticallog(s):
|
|
#s = s.decode('utf-8').encode('gb2312')
|
|
syslog.openlog("FANCONTROL",syslog.LOG_PID)
|
|
syslog.syslog(syslog.LOG_CRIT,s)
|
|
|
|
def fanerror(s):
|
|
#s = s.decode('utf-8').encode('gb2312')
|
|
syslog.openlog("FANCONTROL",syslog.LOG_PID)
|
|
syslog.syslog(syslog.LOG_ERR,s)
|
|
|
|
def fanwarningdebuglog(debuglevel,s):
|
|
#s = s.decode('utf-8').encode('gb2312')
|
|
if FANCTROLDEBUG & debuglevel:
|
|
syslog.openlog("FANCONTROL",syslog.LOG_PID)
|
|
syslog.syslog(syslog.LOG_DEBUG,s)
|
|
|
|
|
|
class FanControl(object):
|
|
critnum = 0
|
|
def __init__(self):
|
|
self._fanOKNum = 0
|
|
self._psuOKNum = 0
|
|
self._intemp = -100.0
|
|
self._mac_aver = -100.0
|
|
self._mac_max = -100.0
|
|
self._preIntemp = -1000 # previous temperature
|
|
self._outtemp = -100
|
|
self._boardtemp = -100
|
|
self._cputemp = -1000
|
|
|
|
@property
|
|
def fanOKNum(self):
|
|
return self._fanOKNum;
|
|
|
|
@property
|
|
def psuOKNum(self):
|
|
return self._psuOKNum;
|
|
|
|
@property
|
|
def cputemp(self):
|
|
return self._cputemp;
|
|
|
|
@property
|
|
def intemp(self):
|
|
return self._intemp;
|
|
|
|
@property
|
|
def outtemp(self):
|
|
return self._outtemp;
|
|
|
|
@property
|
|
def boardtemp(self):
|
|
return self._boardtemp;
|
|
|
|
@property
|
|
def mac_aver(self):
|
|
return self._mac_aver;
|
|
|
|
@property
|
|
def preIntemp(self):
|
|
return self._preIntemp;
|
|
|
|
@property
|
|
def mac_max(self):
|
|
return self._mac_max;
|
|
|
|
def sortCallback(self, element):
|
|
return element['id']
|
|
|
|
def gettemp(self,ret):
|
|
u'''get inlet, outlet, hot-point and cpu temperature'''
|
|
temp_conf = MONITOR_DEV_STATUS.get('temperature', None)
|
|
|
|
if temp_conf is None:
|
|
fanerror("gettemp: config error")
|
|
return False
|
|
for item_temp in temp_conf:
|
|
try:
|
|
retval = ""
|
|
rval = None
|
|
name = item_temp.get('name')
|
|
location = item_temp.get('location')
|
|
if name == "cpu":
|
|
L=[]
|
|
for dirpath, dirnames, filenames in os.walk(location):
|
|
for file in filenames :
|
|
if file.endswith("input"):
|
|
L.append(os.path.join(dirpath, file))
|
|
L =sorted(L,reverse=False)
|
|
for i in range(len(L)):
|
|
nameloc = "%s/temp%d_label"%(location,i+1)
|
|
valloc = "%s/temp%d_input"%(location,i+1)
|
|
with open(nameloc, 'r') as fd1:
|
|
retval2 = fd1.read()
|
|
with open(valloc, 'r') as fd2:
|
|
retval3 = fd2.read()
|
|
ret_t ={}
|
|
ret_t["name"] = retval2.strip()
|
|
ret_t["value"] = float(retval3)/1000
|
|
ret.append(ret_t)
|
|
fanwarningdebuglog(DEBUG_COMMON,"gettemp %s : %f" % (ret_t["name"],ret_t["value"]))
|
|
else:
|
|
locations = glob.glob(location)
|
|
with open(locations[0], 'r') as fd1:
|
|
retval = fd1.read()
|
|
rval = float(retval)/1000
|
|
ret_t ={}
|
|
ret_t["name"] = name
|
|
ret_t["value"] = rval
|
|
ret.append(ret_t)
|
|
fanwarningdebuglog(DEBUG_COMMON,"gettemp %s : %f" % (ret_t["name"],ret_t["value"]))
|
|
except Exception as e:
|
|
fanerror("gettemp error:name:%s" % name)
|
|
fanerror(str(e))
|
|
return True
|
|
|
|
def checkslot(self,ret):
|
|
u'''get slot present status'''
|
|
slots_conf = MONITOR_DEV_STATUS.get('slots', None)
|
|
slotpresent = MONITOR_DEV_STATUS_DECODE.get('slotpresent',None)
|
|
|
|
if slots_conf is None or slotpresent is None:
|
|
return False
|
|
for item_slot in slots_conf:
|
|
totalerr = 0
|
|
try:
|
|
ret_t = {}
|
|
ret_t["id"] = item_slot.get('name')
|
|
ret_t["status"] = ""
|
|
gettype = item_slot.get('gettype')
|
|
presentbit = item_slot.get('presentbit')
|
|
if gettype == "io":
|
|
io_addr = item_slot.get('io_addr')
|
|
val = io_rd(io_addr)
|
|
if val is not None:
|
|
retval = val
|
|
else:
|
|
totalerr -= 1
|
|
fanerror(" %s %s" % (item_slot.get('name'), "lpc read failed"))
|
|
else:
|
|
bus = item_slot.get('bus')
|
|
loc = item_slot.get('loc')
|
|
offset = item_slot.get('offset')
|
|
ind, val = rji2cget(bus, loc,offset)
|
|
if ind == True:
|
|
retval = val
|
|
else:
|
|
totalerr -= 1
|
|
fanerror(" %s %s" % (item_slot.get('name'), "i2c read failed"))
|
|
if totalerr < 0 :
|
|
ret_t["status"] = "NOT OK"
|
|
ret.append(ret_t)
|
|
continue
|
|
val_t = (int(retval,16) & (1<< presentbit)) >> presentbit
|
|
fanwarningdebuglog(DEBUG_COMMON,"%s present:%s" % (item_slot.get('name'),slotpresent.get(val_t)))
|
|
if val_t != slotpresent.get('okval'):
|
|
ret_t["status"] = "ABSENT"
|
|
else:
|
|
ret_t["status"] = "PRESENT"
|
|
except Exception as e:
|
|
ret_t["status"] = "NOT OK"
|
|
totalerr -= 1
|
|
fanerror("checkslot error")
|
|
fanerror(str(e))
|
|
ret.append(ret_t)
|
|
return True
|
|
|
|
def checkpsu(self,ret):
|
|
u'''get psu status present, output and warning'''
|
|
psus_conf = MONITOR_DEV_STATUS.get('psus', None)
|
|
psupresent = MONITOR_DEV_STATUS_DECODE.get('psupresent',None)
|
|
psuoutput = MONITOR_DEV_STATUS_DECODE.get('psuoutput',None)
|
|
psualert = MONITOR_DEV_STATUS_DECODE.get('psualert',None)
|
|
|
|
if psus_conf is None or psupresent is None or psuoutput is None:
|
|
fanerror("checkpsu: config error")
|
|
return False
|
|
for item_psu in psus_conf:
|
|
totalerr = 0
|
|
try:
|
|
ret_t = {}
|
|
ret_t["id"] = item_psu.get('name')
|
|
ret_t["status"] = ""
|
|
gettype = item_psu.get('gettype')
|
|
presentbit = item_psu.get('presentbit')
|
|
statusbit = item_psu.get('statusbit')
|
|
alertbit = item_psu.get('alertbit')
|
|
if gettype == "io":
|
|
io_addr = item_psu.get('io_addr')
|
|
val = io_rd(io_addr)
|
|
if val is not None:
|
|
retval = val
|
|
else:
|
|
totalerr -= 1
|
|
fanerror(" %s %s" % (item_psu.get('name'), "lpc read failed"))
|
|
else:
|
|
bus = item_psu.get('bus')
|
|
loc = item_psu.get('loc')
|
|
offset = item_psu.get('offset')
|
|
ind, val = rji2cget(bus, loc,offset)
|
|
if ind == True:
|
|
retval = val
|
|
else:
|
|
totalerr -= 1
|
|
fanerror(" %s %s" % (item_psu.get('name'), "i2c read failed"))
|
|
if totalerr < 0 :
|
|
ret_t["status"] = "NOT OK"
|
|
ret.append(ret_t)
|
|
continue
|
|
val_t = (int(retval,16) & (1<< presentbit)) >> presentbit
|
|
val_status = (int(retval,16) & (1<< statusbit)) >> statusbit
|
|
val_alert = (int(retval,16) & (1<< alertbit)) >> alertbit
|
|
fanwarningdebuglog(DEBUG_COMMON,"%s present:%s output:%s alert:%s" % (item_psu.get('name'),psupresent.get(val_t),psuoutput.get(val_status),psualert.get(val_alert)))
|
|
if val_t != psupresent.get('okval') or val_status != psuoutput.get('okval') or val_alert != psualert.get('okval'):
|
|
totalerr -=1
|
|
except Exception as e:
|
|
totalerr -= 1
|
|
fanerror("checkpsu error")
|
|
fanerror(str(e))
|
|
if totalerr < 0:
|
|
ret_t["status"] = "NOT OK"
|
|
else:
|
|
ret_t["status"] = "OK"
|
|
ret.append(ret_t)
|
|
return True
|
|
|
|
def checkfan(self,ret):
|
|
u'''get fan status present and roll'''
|
|
fans_conf = MONITOR_DEV_STATUS.get('fans', None)
|
|
fanpresent = MONITOR_DEV_STATUS_DECODE.get('fanpresent',None)
|
|
fanroll = MONITOR_DEV_STATUS_DECODE.get('fanroll',None)
|
|
|
|
if fans_conf is None or fanpresent is None or fanroll is None:
|
|
fanerror("checkfan: config error")
|
|
return False
|
|
for item_fan in fans_conf:
|
|
totalerr = 0
|
|
try:
|
|
ret_t = {}
|
|
ret_t["id"] = item_fan.get('name')
|
|
ret_t["status"] = ""
|
|
presentstatus = item_fan.get('presentstatus')
|
|
presentbus = presentstatus.get('bus')
|
|
presentloc = presentstatus.get('loc')
|
|
presentaddr = presentstatus.get('offset')
|
|
presentbit = presentstatus.get('bit')
|
|
ind, val = rji2cget(presentbus, presentloc,presentaddr)
|
|
if ind == True:
|
|
val_t = (int(val,16) & (1<< presentbit)) >> presentbit
|
|
fanwarningdebuglog(DEBUG_COMMON,"checkfan:%s present status:%s" % (item_fan.get('name'),fanpresent.get(val_t)))
|
|
if val_t != fanpresent.get('okval'):
|
|
ret_t["status"] = "ABSENT"
|
|
ret.append(ret_t)
|
|
continue
|
|
else:
|
|
fanerror("checkfan: %s get present status error." % item_fan.get('name'))
|
|
motors = item_fan.get("rollstatus")
|
|
for motor in motors:
|
|
statusbus = motor.get('bus', None)
|
|
statusloc = motor.get('loc', None)
|
|
statusaddr = motor.get('offset', None)
|
|
statusbit = motor.get('bit', None)
|
|
ind, val = rji2cget(statusbus, statusloc, statusaddr)
|
|
if ind == True:
|
|
val_t = (int(val,16) & (1<< statusbit)) >> statusbit
|
|
fanwarningdebuglog(DEBUG_COMMON,"checkfan:%s roll status:%s" % (motor.get('name'),fanroll.get(val_t)))
|
|
if val_t != fanroll.get('okval'):
|
|
totalerr -= 1
|
|
else:
|
|
totalerr -= 1
|
|
fanerror("checkfan: %s " % item_fan.get('name'))
|
|
fanerror("get %s status error." % motor["name"])
|
|
except Exception as e:
|
|
totalerr -= 1
|
|
fanerror("checkfan error")
|
|
fanerror(str(e))
|
|
if totalerr < 0:
|
|
ret_t["status"] = "NOT OK"
|
|
else:
|
|
ret_t["status"] = "OK"
|
|
ret.append(ret_t)
|
|
return True
|
|
|
|
def getCurrentSpeed(self):
|
|
try:
|
|
loc = fanloc[0].get("location","")
|
|
sped = get_sysfs_value(loc)
|
|
value = strtoint(sped)
|
|
return value
|
|
except Exception as e:
|
|
fanerror("%%policy: get current speedlevel error")
|
|
fanerror(str(e))
|
|
return None
|
|
|
|
# guarantee the speed is lowest when speed lower than lowest value after speed-adjustment
|
|
def checkCurrentSpeedSet(self):
|
|
fanwarningdebuglog(DEBUG_FANCONTROL,"%%policy: guarantee the lowest speed after speed-adjustment")
|
|
value = self.getCurrentSpeed()
|
|
if value is None or value == 0:
|
|
raise Exception("%%policy: getCurrentSpeed None")
|
|
elif value < MONITOR_CONST.MIN_SPEED:
|
|
self.fanSpeedSet(MONITOR_CONST.MIN_SPEED)
|
|
|
|
|
|
def fanSpeedSet(self, level):
|
|
if level >= MONITOR_CONST.MAX_SPEED:
|
|
level = MONITOR_CONST.MAX_SPEED
|
|
for item in fanloc:
|
|
try:
|
|
loc = item.get("location","")
|
|
write_sysfs_value(loc, "0x%02x"% level )
|
|
except Exception as e:
|
|
fanerror(str(e))
|
|
fanerror("%%policy: config fan runlevel error")
|
|
self.checkCurrentSpeedSet() # guaranteed minimum
|
|
|
|
def fanSpeedSetMax(self):
|
|
try:
|
|
self.fanSpeedSet(MONITOR_CONST.MAX_SPEED)
|
|
except Exception as e:
|
|
fanerror("%%policy:fanSpeedSetMax failed")
|
|
fanerror(str(e))
|
|
|
|
def fanStatusCheck(self): # fan status check , max speed if fan error
|
|
if self.fanOKNum < MONITOR_CONST.FAN_TOTAL_NUM:
|
|
fanwarninglog("%%DEV_MONITOR-FAN: Normal fan number: %d" % (self.fanOKNum))
|
|
self.fanSpeedSetMax()
|
|
return False
|
|
return True
|
|
|
|
def setFanAttr(self,val):
|
|
u'''set status of each fan'''
|
|
for item in val:
|
|
fanid = item.get("id")
|
|
fanattr = fanid + "status"
|
|
fanstatus = item.get("status")
|
|
setattr(FanControl,fanattr,fanstatus)
|
|
fanwarningdebuglog(DEBUG_COMMON,"fanattr:%s,fanstatus:%s"% (fanattr,fanstatus))
|
|
|
|
def getFanPresentNum(self,curFanStatus):
|
|
fanoknum = 0;
|
|
for item in curFanStatus:
|
|
if item["status"] == "OK":
|
|
fanoknum += 1
|
|
self._fanOKNum = fanoknum
|
|
fanwarningdebuglog(DEBUG_COMMON,"fanOKNum = %d"% self._fanOKNum)
|
|
|
|
def getFanStatus(self):
|
|
try:
|
|
curFanStatus = []
|
|
ret = self.checkfan(curFanStatus)
|
|
if ret == True:
|
|
self.setFanAttr(curFanStatus)
|
|
self.getFanPresentNum(curFanStatus)
|
|
fanwarningdebuglog(DEBUG_COMMON,"%%policy:getFanStatus success" )
|
|
return 0
|
|
except AttributeError as e:
|
|
fanerror(str(e))
|
|
except Exception as e:
|
|
fanerror(str(e))
|
|
return -1
|
|
|
|
def getPsuOkNum(self,curPsuStatus):
|
|
psuoknum = 0;
|
|
for item in curPsuStatus:
|
|
if item.get("status") == "OK":
|
|
psuoknum += 1
|
|
self._psuOKNum = psuoknum
|
|
fanwarningdebuglog(DEBUG_COMMON,"psuOKNum = %d"% self._psuOKNum)
|
|
|
|
def getPsuStatus(self):
|
|
try:
|
|
curPsuStatus = []
|
|
ret = self.checkpsu(curPsuStatus)
|
|
if ret == True:
|
|
self.getPsuOkNum(curPsuStatus)
|
|
fanwarningdebuglog(DEBUG_COMMON,"%%policy:getPsuStatus success" )
|
|
return 0
|
|
except AttributeError as e:
|
|
fanerror(str(e))
|
|
except Exception as e:
|
|
fanerror(str(e))
|
|
return -1
|
|
|
|
def getMonitorTemp(self, temp):
|
|
for item in temp:
|
|
if item.get('name') == "lm75in":
|
|
self._intemp = item.get('value',self._intemp)
|
|
if item.get('name') == "lm75out":
|
|
self._outtemp = item.get('value',self._outtemp)
|
|
if item.get('name') == "lm75hot":
|
|
self._boardtemp = item.get('value',self._boardtemp)
|
|
if item.get('name') == "Physical id 0":
|
|
self._cputemp = item.get('value',self._cputemp)
|
|
fanwarningdebuglog(DEBUG_COMMON,"intemp:%f, outtemp:%f, boadrtemp:%f, cputemp:%f"% (self._intemp,self._outtemp,self._boardtemp,self._cputemp))
|
|
|
|
def getTempStatus(self):
|
|
try:
|
|
monitortemp =[]
|
|
ret = self.gettemp(monitortemp)
|
|
if ret == True:
|
|
self.getMonitorTemp(monitortemp)
|
|
fanwarningdebuglog(DEBUG_COMMON,"%%policy:getTempStatus success" )
|
|
return 0
|
|
except AttributeError as e:
|
|
fanerror(str(e))
|
|
except Exception as e:
|
|
fanerror(str(e))
|
|
return -1
|
|
|
|
def getMacStatus_bcmcmd(self):
|
|
try:
|
|
if waitForDocker(timeout = 0) == True :
|
|
sta, ret = getMacTemp()
|
|
if sta == True:
|
|
self._mac_aver = float(ret.get("average",self._mac_aver))
|
|
self._mac_max = float(ret.get("maximum",self._mac_max))
|
|
fanwarningdebuglog(DEBUG_COMMON,"mac_aver:%f, mac_max:%f" % (self.mac_aver,self._mac_max))
|
|
else:
|
|
fanwarningdebuglog(DEBUG_COMMON,"%%policy:getMacStatus_bcmcmd failed" )
|
|
else:
|
|
fanwarningdebuglog(DEBUG_COMMON,"%%policy:getMacStatus_bcmcmd SDK not OK" )
|
|
return 0
|
|
except AttributeError as e:
|
|
fanerror(str(e))
|
|
return -1
|
|
|
|
def getMacStatus_sysfs(self,conf):
|
|
try:
|
|
sta, ret = getMacTemp_sysfs(conf)
|
|
if sta == True:
|
|
self._mac_aver = float(ret) / 1000
|
|
self._mac_max = float(ret) / 1000
|
|
fanwarningdebuglog(DEBUG_COMMON,"mac_aver:%f, mac_max:%f" % (self.mac_aver,self._mac_max))
|
|
elif conf.get("try_bcmcmd", 0) == 1:
|
|
fanwarningdebuglog(DEBUG_COMMON,"get sysfs mac temp failed.try to use bcmcmd")
|
|
self.getMacStatus_bcmcmd()
|
|
else:
|
|
fanwarningdebuglog(DEBUG_COMMON,"%%policy:getMacStatus_sysfs failed" )
|
|
return 0
|
|
except AttributeError as e:
|
|
fanerror(str(e))
|
|
return -1
|
|
|
|
def getMacStatus(self):
|
|
try:
|
|
mactempconf = MONITOR_DEV_STATUS.get('mac_temp', None)
|
|
if mactempconf is not None:
|
|
self.getMacStatus_sysfs(mactempconf)
|
|
else:
|
|
self.getMacStatus_bcmcmd()
|
|
return 0
|
|
except AttributeError as e:
|
|
fanerror(str(e))
|
|
return -1
|
|
|
|
def settSlotAttr(self,val):
|
|
u'''set each slot present status attribute'''
|
|
for item in val:
|
|
slotid = item.get("id")
|
|
slotattr = slotid + "status"
|
|
slotstatus = item.get("status")
|
|
setattr(FanControl,slotattr,slotstatus)
|
|
fanwarningdebuglog(DEBUG_COMMON,"slotattr:%s,slotstatus:%s"% (slotattr,slotstatus))
|
|
|
|
def getSlotStatus(self):
|
|
try:
|
|
curSlotStatus = []
|
|
ret = self.checkslot(curSlotStatus)
|
|
if ret == True:
|
|
self.settSlotAttr(curSlotStatus)
|
|
fanwarningdebuglog(DEBUG_COMMON,"%%policy:getSlotStatus success" )
|
|
except AttributeError as e:
|
|
fanerror(str(e))
|
|
return 0
|
|
|
|
def fanctrol(self): #fan speed-adjustment
|
|
try:
|
|
if self.preIntemp <= -1000:
|
|
self.preIntemp = self.intemp
|
|
fanwarningdebuglog(DEBUG_FANCONTROL,"%%policy:previous temperature[%.2f] , current temperature[%.2f]" % (self.preIntemp,self.intemp))
|
|
if self.intemp < MONITOR_CONST.TEMP_MIN:
|
|
fanwarningdebuglog(DEBUG_FANCONTROL,"%%policy:inlet %.2f minimum temperature: %.2f" %(self.intemp,MONITOR_CONST.TEMP_MIN))
|
|
self.fanSpeedSet(MONITOR_CONST.DEFAULT_SPEED) # default level
|
|
elif self.intemp >= MONITOR_CONST.TEMP_MIN and self.intemp > self.preIntemp:
|
|
fanwarningdebuglog(DEBUG_FANCONTROL,"%%policy:increase temperature")
|
|
self.policySpeed(self.intemp)
|
|
elif self.intemp >= MONITOR_CONST.TEMP_MIN and (self.preIntemp - self.intemp) > MONITOR_CONST.MONITOR_FALL_TEMP:
|
|
fanwarningdebuglog(DEBUG_FANCONTROL,"%%policy:temperature reduce over %d degree" % MONITOR_CONST.MONITOR_FALL_TEMP)
|
|
self.policySpeed(self.intemp)
|
|
else:
|
|
speed = self.getCurrentSpeed()# set according to current speed, prevent fan watch-dog
|
|
if speed is not None:
|
|
self.fanSpeedSet(speed)
|
|
fanwarningdebuglog(DEBUG_FANCONTROL,"%%policy:change nothing")
|
|
except Exception as e:
|
|
fanerror("%%policy: fancontrol error")
|
|
|
|
# start speed-adjustment
|
|
def startFanCtrol(self):
|
|
self.checkCrit()
|
|
if self.critnum == 0 and self.checkWarning() == False and self.fanStatusCheck() ==True:
|
|
self.fanctrol()
|
|
self.checkDevError()
|
|
fanwarningdebuglog(DEBUG_FANCONTROL,"%%policy: speed after speed-adjustment is %0x" % (self.getCurrentSpeed()))
|
|
|
|
def policySpeed(self, temp): # fan speed-adjustment algorithm
|
|
fanwarningdebuglog(DEBUG_FANCONTROL,"%%policy:fan speed-adjustment algorithm")
|
|
sped_level = MONITOR_CONST.DEFAULT_SPEED + MONITOR_CONST.K * (temp - MONITOR_CONST.TEMP_MIN)
|
|
self.fanSpeedSet(sped_level)
|
|
self.preIntemp = self.intemp
|
|
|
|
def getBoardMonitorMsg(self,ledcontrol = False):
|
|
ret_t = 0
|
|
try:
|
|
ret_t += self.getFanStatus() # get fan status, get number of fan which status is OK
|
|
ret_t += self.getTempStatus() # get inlet, outlet, hot-point temperature, CPU temperature
|
|
ret_t += self.getMacStatus() # get MAC highest and average temperature
|
|
if ledcontrol == True:
|
|
ret_t += self.getSlotStatus() # get slot present status
|
|
ret_t += self.getPsuStatus() # get psu status
|
|
if ret_t == 0:
|
|
return True
|
|
except Exception as e:
|
|
fanerror(str(e))
|
|
return False
|
|
|
|
# device error algorithm Tmac-Tin≥50℃, or Tmac-Tin≤-50℃
|
|
def checkDevError(self):
|
|
try:
|
|
if (self.mac_aver - self.intemp) >= MONITOR_CONST.MAC_UP_TEMP or (self.mac_aver - self.intemp) <= MONITOR_CONST.MAC_LOWER_TEMP:
|
|
fanwarningdebuglog(DEBUG_FANCONTROL,"%%DEV_MONITOR-TEMP: MAC temp get failed.")
|
|
value = self.getCurrentSpeed()
|
|
if MONITOR_CONST.MAC_ERROR_SPEED >= value:
|
|
self.fanSpeedSet(MONITOR_CONST.MAC_ERROR_SPEED)
|
|
else:
|
|
self.fanSpeedSetMax()
|
|
else:
|
|
pass
|
|
except Exception as e:
|
|
fanerror("%%policy:checkDevError failed")
|
|
fanerror(str(e))
|
|
|
|
def checkTempWarning(self):
|
|
u'''check whether temperature above the normal alarm value'''
|
|
try:
|
|
if self._mac_aver >= MONITOR_CONST.MAC_WARNING_THRESHOLD \
|
|
or self._outtemp >= MONITOR_CONST.OUTTEMP_WARNING_THRESHOLD \
|
|
or self._boardtemp >= MONITOR_CONST.BOARDTEMP_WARNING_THRESHOLD \
|
|
or self._cputemp>=MONITOR_CONST.CPUTEMP_WARNING_THRESHOLD \
|
|
or self._intemp >=MONITOR_CONST.INTEMP_WARNING_THRESHOLD:
|
|
fanwarningdebuglog(DEBUG_COMMON,"check whether temperature above the normal alarm value")
|
|
return True
|
|
except Exception as e:
|
|
fanerror("%%policy: checkTempWarning failed")
|
|
fanerror(str(e))
|
|
return False
|
|
|
|
def checkTempCrit(self):
|
|
u'''check whether temperature above the critical alarm value'''
|
|
try:
|
|
if self._mac_aver >= MONITOR_CONST.MAC_CRITICAL_THRESHOLD \
|
|
or ( self._outtemp >= MONITOR_CONST.OUTTEMP_CRITICAL_THRESHOLD \
|
|
and self._boardtemp >= MONITOR_CONST.BOARDTEMP_CRITICAL_THRESHOLD \
|
|
and self._cputemp>= MONITOR_CONST.CPUTEMP_CRITICAL_THRESHOLD \
|
|
and self._intemp >= MONITOR_CONST.INTEMP_CRITICAL_THRESHOLD):
|
|
fanwarningdebuglog(DEBUG_COMMON,"temperature above the critical alarm value")
|
|
return True
|
|
except Exception as e:
|
|
fanerror("%%policy: checkTempCrit failed")
|
|
fanerror(str(e))
|
|
return False
|
|
|
|
def checkFanStatus(self):
|
|
u'''check fan status'''
|
|
for item in MONITOR_FAN_STATUS:
|
|
maxoknum = item.get('maxOkNum')
|
|
minoknum = item.get('minOkNum')
|
|
status = item.get('status')
|
|
if self.fanOKNum >= minoknum and self.fanOKNum <= maxoknum :
|
|
fanwarningdebuglog(DEBUG_COMMON,"checkFanStatus:fanOKNum:%d,status:%s" % (self.fanOKNum,status))
|
|
return status
|
|
fanwarningdebuglog(DEBUG_COMMON,"checkFanStatus Error:fanOKNum:%d" % (self.fanOKNum))
|
|
return None
|
|
|
|
def checkPsuStatus(self):
|
|
u'''check psu status'''
|
|
for item in MONITOR_PSU_STATUS:
|
|
maxoknum = item.get('maxOkNum')
|
|
minoknum = item.get('minOkNum')
|
|
status = item.get('status')
|
|
if self.psuOKNum >= minoknum and self.psuOKNum <= maxoknum :
|
|
fanwarningdebuglog(DEBUG_COMMON,"checkPsuStatus:psuOKNum:%d,status:%s" % (self.psuOKNum,status))
|
|
return status
|
|
fanwarningdebuglog(DEBUG_COMMON,"checkPsuStatus Error:psuOKNum:%d" % (self.psuOKNum))
|
|
return None
|
|
|
|
def dealSysLedStatus(self):
|
|
u'''set up SYSLED according to temperature, fan and psu status'''
|
|
try:
|
|
fanstatus = self.checkFanStatus()
|
|
psustatus = self.checkPsuStatus()
|
|
if self.checkTempCrit() == True or fanstatus == "red" or psustatus == "red":
|
|
status = "red"
|
|
elif self.checkTempWarning() == True or fanstatus == "yellow" or psustatus == "yellow":
|
|
status = "yellow"
|
|
else:
|
|
status = "green"
|
|
self.setSysLed(status)
|
|
fanwarningdebuglog(DEBUG_LEDCONTROL,"%%ledcontrol:dealSysLedStatus success, status:%s," % status)
|
|
except Exception as e:
|
|
fanerror(str(e))
|
|
|
|
def dealSysFanLedStatus(self):
|
|
u'''light panel fan led according to status'''
|
|
try:
|
|
status = self.checkFanStatus()
|
|
if status is not None:
|
|
self.setSysFanLed(status)
|
|
fanwarningdebuglog(DEBUG_LEDCONTROL,"%%ledcontrol:dealSysFanLedStatus success, status:%s," % status)
|
|
except Exception as e:
|
|
fanerror("%%ledcontrol:dealSysLedStatus error")
|
|
fanerror(str(e))
|
|
|
|
def dealPsuLedStatus(self):
|
|
u'''set up PSU-LED according to psu status'''
|
|
try:
|
|
status = self.checkPsuStatus()
|
|
if status is not None:
|
|
self.setSysPsuLed(status)
|
|
fanwarningdebuglog(DEBUG_LEDCONTROL,"%%ledcontrol:dealPsuLedStatus success, status:%s," % status)
|
|
except Exception as e:
|
|
fanerror("%%ledcontrol:dealPsuLedStatus error")
|
|
fanerror(str(e))
|
|
|
|
def dealLocFanLedStatus(self):
|
|
u'''light fan led according to fan status'''
|
|
for item in MONITOR_FANS_LED:
|
|
try:
|
|
index = MONITOR_FANS_LED.index(item) + 1
|
|
fanattr = "fan%dstatus" % index
|
|
val_t = getattr(FanControl,fanattr,None)
|
|
if val_t == "NOT OK":
|
|
rji2cset(item["bus"],item["devno"],item["addr"], item["red"])
|
|
elif val_t == "OK":
|
|
rji2cset(item["bus"],item["devno"],item["addr"], item["green"])
|
|
else:
|
|
pass
|
|
fanwarningdebuglog(DEBUG_LEDCONTROL,"%%ledcontrol:dealLocFanLed success.fanattr:%s, status:%s"% (fanattr,val_t))
|
|
except Exception as e:
|
|
fanerror("%%ledcontrol:dealLocFanLedStatus error")
|
|
fanerror(str(e))
|
|
|
|
def dealSlotLedStatus(self):
|
|
u'''light slot status led according to slot present status'''
|
|
slotLedList = DEV_LEDS.get("SLOTLED",[])
|
|
for item in slotLedList:
|
|
try:
|
|
index = slotLedList.index(item) + 1
|
|
slotattr = "slot%dstatus" % index
|
|
val_t = getattr(FanControl,slotattr,None)
|
|
if val_t == "PRESENT":
|
|
rji2cset(item["bus"],item["devno"],item["addr"], item["green"])
|
|
fanwarningdebuglog(DEBUG_LEDCONTROL,"%%ledcontrol:dealSlotLedStatus success.slotattr:%s, status:%s"% (slotattr,val_t))
|
|
except Exception as e:
|
|
fanerror("%%ledcontrol:dealSlotLedStatus error")
|
|
fanerror(str(e))
|
|
|
|
def dealBmcLedstatus(self,val):
|
|
pass
|
|
|
|
def dealLctLedstatus(self,val):
|
|
pass
|
|
|
|
def setled(self, item, color):
|
|
if item.get('type', 'i2c') == 'sysfs':
|
|
rjsysset(item["cmdstr"], item.get(color))
|
|
else :
|
|
mask = item.get('mask', 0xff)
|
|
ind, val = rji2cget(item["bus"], item["devno"], item["addr"])
|
|
if ind == True:
|
|
setval = (int(val,16) & ~mask) | item.get(color)
|
|
rji2cset(item["bus"], item["devno"], item["addr"], setval)
|
|
else:
|
|
fanerror("led %s" % "i2c read failed")
|
|
|
|
def setSysLed(self,color):
|
|
for item in MONITOR_SYS_LED:
|
|
self.setled(item, color)
|
|
|
|
def setSysFanLed(self,color):
|
|
for item in MONITOR_SYS_FAN_LED:
|
|
self.setled(item, color)
|
|
|
|
def setSysPsuLed(self,color):
|
|
for item in MONITOR_SYS_PSU_LED:
|
|
self.setled(item, color)
|
|
|
|
def checkWarning(self):
|
|
try:
|
|
if self.checkTempWarning() == True:
|
|
fanwarningdebuglog(DEBUG_FANCONTROL,"anti-shake start")
|
|
time.sleep(MONITOR_CONST.SHAKE_TIME)
|
|
fanwarningdebuglog(DEBUG_FANCONTROL,"anti-shake end")
|
|
self.getBoardMonitorMsg()# re-read
|
|
if self.checkTempWarning() == True:
|
|
fanwarninglog("%%DEV_MONITOR-TEMP:The temperature of device is over warning value.")
|
|
self.fanSpeedSetMax() # fan full speed
|
|
return True
|
|
except Exception as e:
|
|
fanerror("%%policy: checkWarning failed")
|
|
fanerror(str(e))
|
|
return False
|
|
|
|
def checkCrit(self):
|
|
try:
|
|
if self.checkTempCrit() == True:
|
|
fanwarningdebuglog(DEBUG_FANCONTROL,"anti-shake start")
|
|
time.sleep(MONITOR_CONST.SHAKE_TIME)
|
|
fanwarningdebuglog(DEBUG_FANCONTROL,"anti-shake end")
|
|
self.getBoardMonitorMsg()# re-read
|
|
if self.checkTempCrit() == True:
|
|
fancriticallog("%%DEV_MONITOR-TEMP:The temperature of device is over critical value.")
|
|
self.fanSpeedSetMax() # fan full speed
|
|
self.critnum += 1 # anti-shake
|
|
if self.critnum >= MONITOR_CONST.CRITICAL_NUM:
|
|
os.system("reboot")
|
|
fanwarningdebuglog(DEBUG_FANCONTROL,"crit次数:%d" % self.critnum)
|
|
else:
|
|
self.critnum = 0
|
|
else:
|
|
self.critnum = 0
|
|
except Exception as e:
|
|
fanerror("%%policy: checkCrit failed")
|
|
fanerror(str(e))
|
|
|
|
|
|
def callback():
|
|
pass
|
|
|
|
def doFanCtrol(fanCtrol):
|
|
ret = fanCtrol.getBoardMonitorMsg()
|
|
if ret==True:
|
|
fanwarningdebuglog(DEBUG_FANCONTROL,"%%policy:startFanCtrol")
|
|
fanCtrol.startFanCtrol()
|
|
else:
|
|
fanCtrol.fanSpeedSetMax()
|
|
fanwarningdebuglog(DEBUG_FANCONTROL,"%%policy:getBoardMonitorMsg error")
|
|
|
|
def doLedCtrol(fanCtrol):
|
|
fanCtrol.getBoardMonitorMsg(ledcontrol = True) # get status
|
|
fanCtrol.dealSysLedStatus() # light system led
|
|
fanCtrol.dealSysFanLedStatus() # light panel fan led
|
|
fanCtrol.dealLocFanLedStatus() # light fan led
|
|
fanCtrol.dealPsuLedStatus() # light psu led
|
|
fanCtrol.dealSlotLedStatus() # light slot status led
|
|
fanwarningdebuglog(DEBUG_LEDCONTROL,"%%ledcontrol:doLedCtrol success")
|
|
|
|
def run(interval, fanCtrol):
|
|
loop = 0
|
|
# waitForDocker()
|
|
while True:
|
|
try:
|
|
if loop % MONITOR_CONST.MONITOR_INTERVAL ==0: # fan speed-adjustment
|
|
fanwarningdebuglog(DEBUG_FANCONTROL,"%%policy:fanCtrol")
|
|
doFanCtrol(fanCtrol)
|
|
else:
|
|
fanwarningdebuglog(DEBUG_LEDCONTROL,"%%ledcontrol:start ledctrol")# LED control
|
|
doLedCtrol(fanCtrol)
|
|
time.sleep(interval)
|
|
loop += interval
|
|
except Exception as e:
|
|
traceback.print_exc()
|
|
fanerror(str(e))
|
|
|
|
@click.group(cls=AliasedGroup, context_settings=CONTEXT_SETTINGS)
|
|
def main():
|
|
'''device operator'''
|
|
pass
|
|
|
|
@main.command()
|
|
def start():
|
|
'''start fan control'''
|
|
fanwarninglog("FANCTROL start")
|
|
fanCtrol = FanControl()
|
|
interval = MONITOR_CONST.MONITOR_INTERVAL /30
|
|
run(interval, fanCtrol)
|
|
|
|
@main.command()
|
|
def stop():
|
|
'''stop fan control '''
|
|
fanwarninglog("stop")
|
|
|
|
##device_i2c operation
|
|
if __name__ == '__main__':
|
|