sonic-buildimage/device/mellanox/x86_64-mlnx_msn3800-r0/Mellanox-SN3800-D112C8
Stephen Sun d44936fa59
[Mellanox][201911] Support buffer configuration for 2km cable (#7338)
#### Why I did it
1. Update pg_profile_lookup.ini with 2000m cable supported
2. Update buffer configuration for t1 with uplink cable 2000m
  - For SN3800 platform:
    - C64:
      - t0: 32 100G down links and 32 100G up links.
      - t1: 56 100G down links and 8 100G up links with 2 km cable.
    - D112C8: 112 50G down links and 8 100G up links.
    - D24C52: 24 50G down links, 20 100G down links, and 32 100G up links.
    - D28C50: 28 50G down links, 18 100G down links, and 32 100G up links.
  - For SN2700 platform:
    - D48C8: 48 50G down links and 8 100G up links
    - C32:
      - t0: 16 100G down links and 16 100G up links.
      - t1: 24 100G down links and 8 100G up links with 2 km cable.

Signed-off-by: Stephen Sun <stephens@nvidia.com>

#### How I did it

#### How to verify it
Run QoS regression test
2021-05-30 20:03:16 -07:00
..
buffers_defaults_t0.j2 [Mellanox] [201911] Support shared headroom pool (#5908) 2021-01-07 09:20:22 +02:00
buffers_defaults_t1.j2 [Mellanox] [201911] Support shared headroom pool (#5908) 2021-01-07 09:20:22 +02:00
buffers.json.j2 [mellanox]: Add new Mellanox-SN3800-D112C8 sku. (#4085) 2020-02-03 15:39:14 -08:00
pg_profile_lookup.ini [Mellanox][201911] Support buffer configuration for 2km cable (#7338) 2021-05-30 20:03:16 -07:00
port_config.ini [Mellanox] Change port index in port_config.ini to 1-based (#4781) 2020-06-28 07:24:10 -07:00
qos.json.j2 [mellanox]: Add new Mellanox-SN3800-D112C8 sku. (#4085) 2020-02-03 15:39:14 -08:00
sai_3800_112x50g_8x100g.xml [Mellanox]Mellanox-SN3800-D112C8 support warm-reboot (#4482) 2020-04-30 22:15:12 -07:00
sai.profile Vxlan src port range for breakout SKU (#7612) 2021-05-14 11:42:58 -07:00