b76f8fafdb
* Update the buffer size based on the latest excel Signed-off-by: Stephen Sun <stephens@mellanox.com> * Align the buffer configuration with the latest formula: - reduce redundant "*2" in formula - use port MTU for local sending the PFC frame and peer lossless MTU for peer sending lossless traffic Buffer pool size updated accordingly. Signed-off-by: Stephen Sun <stephens@mellanox.com>
18 lines
746 B
INI
18 lines
746 B
INI
# PG lossless profiles.
|
|
# speed cable size xon xoff threshold
|
|
10000 5m 54272 19456 34816 0
|
|
25000 5m 58368 19456 38912 0
|
|
40000 5m 61440 19456 41984 0
|
|
50000 5m 64512 19456 45056 0
|
|
100000 5m 75776 19456 56320 0
|
|
10000 40m 55296 19456 35840 0
|
|
25000 40m 60416 19456 40960 0
|
|
40000 40m 65536 19456 46080 0
|
|
50000 40m 69632 19456 50176 0
|
|
100000 40m 86016 19456 66560 0
|
|
10000 300m 63488 19456 44032 0
|
|
25000 300m 78848 19456 59392 0
|
|
40000 300m 95232 19456 75776 0
|
|
50000 300m 106496 19456 87040 0
|
|
100000 300m 159744 19456 140288 0
|