sonic-buildimage/files/image_config/topology
SuvarnaMeenakshi 9208dc507b [multi-asic][vs]: Update topology script to retrieve hwsku from minigraph (#6219)
Update topology script to retrieve hwsku from minigraph
if hwsku information is not available in config_db.
Fix clean up of interfaces in msft_multi_asic_vs hwsku
topology script.
- Why I did it
When bringing up multi-asic VS switch, topology service is started during boot up.
Topology service starts a shell script which runs the topology script present in /usr/share/sonic/device// directory. To invoke hwsku specific script, the topology script tries to retrieve hwsku information from config_db.
During initial boot up config_db might not be populated. In order to start topology service before config_db is updated,
update topology script to get hwsku information from minigraph.xml if it is available.
This will be helpful to bring up multi-asic VS testbed by loading minigraph and starting topology service.
- How I did it
Update topology.sh script to retrieve hwsku information from minigraph.xml.
Fix clean up function on msft_multi_asic_vs toplogy script.
- How to verify it
single-asic VS - no change; topology service is only enabled for multi-asic VS.
multi-asic VS - Bring up multi-asic VS image, copy minigraph to vs image, start topology service. Topology service should be successful.
to test clean up function fix, start topology service - make sure interfaces are created and moved to the right namespaces.
stop topology service - make sure namespace do not have any interface and all front end interfaces are present in default namespace.
2021-02-25 18:42:44 -08:00
..
topology.service [baseimage]: support building multi-asic component (#3856) 2020-02-03 15:32:21 -08:00
topology.sh [multi-asic][vs]: Update topology script to retrieve hwsku from minigraph (#6219) 2021-02-25 18:42:44 -08:00