#!/usr/bin/env python3
|
|
# -*- coding: UTF-8 -*-
|
|
import click
|
|
import time
|
|
import syslog
|
|
import traceback
|
|
from ruijieutil import waitForDocker, STARTMODULE, AVSUTIL
|
|
try:
|
|
from rest.rest import BMCMessage
|
|
except ImportError:
|
|
pass
|
|
|
|
CONTEXT_SETTINGS = dict(help_option_names=['-h', '--help'])
|
|
|
|
class AliasedGroup(click.Group):
|
|
def get_command(self, ctx, cmd_name):
|
|
rv = click.Group.get_command(self, ctx, cmd_name)
|
|
if rv is not None:
|
|
return rv
|
|
matches = [x for x in self.list_commands(ctx)
|
|
if x.startswith(cmd_name)]
|
|
if not matches:
|
|
return None
|
|
elif len(matches) == 1:
|
|
return click.Group.get_command(self, ctx, matches[0])
|
|
ctx.fail('Too many matches: %s' % ', '.join(sorted(matches)))
|
|
|
|
def avswarninglog(s):
|
|
s = s.decode('utf-8').encode('gb2312')
|
|
syslog.openlog("AVSCONTROL",syslog.LOG_PID)
|
|
syslog.syslog(syslog.LOG_WARNING,s)
|
|
|
|
def avscriticallog(s):
|
|
s = s.decode('utf-8').encode('gb2312')
|
|
syslog.openlog("AVSCONTROL",syslog.LOG_PID)
|
|
syslog.syslog(syslog.LOG_CRIT,s)
|
|
|
|
def avserror(s):
|
|
s = s.decode('utf-8').encode('gb2312')
|
|
syslog.openlog("AVSCONTROL",syslog.LOG_PID)
|
|
syslog.syslog(syslog.LOG_ERR,s)
|
|
|
|
def avsinfo(s):
|
|
syslog.openlog("AVSCONTROL",syslog.LOG_PID)
|
|
syslog.syslog(syslog.LOG_INFO,s)
|
|
|
|
def doAvsCtrol():
|
|
index = 0
|
|
url = "/xyz/openbmc_project/hostchannel/attr/MacRov"
|
|
while True:
|
|
if "avscontrol_restful" in STARTMODULE and STARTMODULE['avscontrol_restful'] == 1:
|
|
try:
|
|
#for alibmc rest.py has define get_macrov_value function
|
|
get_macrov_value = getattr(BMCMessage(), "get_macrov_value", None)
|
|
if callable(get_macrov_value):
|
|
macrov_value = int(get_macrov_value())
|
|
else:
|
|
macrov_value = int(BMCMessage().getBmcValue(url))
|
|
if macrov_value >= 0:
|
|
break
|
|
except Exception as e:
|
|
time.sleep(2)
|
|
continue
|
|
else:
|
|
if AVSUTIL.mac_adj():
|
|
break
|
|
|
|
index += 1
|
|
if index >= 10:
|
|
avserror("%%DEV_MONITOR-AVS: MAC Voltage adjust failed.")
|
|
exit(-1)
|
|
avsinfo("%%AVSCONTROL success")
|
|
exit(0)
|
|
|
|
def run(interval):
|
|
while True:
|
|
try:
|
|
if waitForDocker(timeout = 0) == True:
|
|
time.sleep(10) # w10s
|
|
doAvsCtrol()
|
|
time.sleep(interval)
|
|
except Exception as e:
|
|
traceback.print_exc()
|
|
print(e)
|
|
|
|
@click.group(cls=AliasedGroup, context_settings=CONTEXT_SETTINGS)
|
|
def main():
|
|
'''device operator'''
|
|
pass
|
|
|
|
@main.command()
|
|
def start():
|
|
'''start AVS control'''
|
|
avsinfo("%%AVSCONTROL start")
|
|
interval = 5
|
|
run(interval)
|
|
|
|
##device_i2c operation
|
|
if __name__ == '__main__':
|
|
main()
|