Avoid write_standby in warm restart context. sign-off: Jing Zhang zhangjing@microsoft.com Why I did it In warm restart context, we should avoid mux state change. How I did it Check warm restart flag before applying changes to app db. How to verify it Ran write_standby in table missing, key missing, field missing scenarios. Did a warm restart, app db changes were skipped. Saw this in syslog: WARNING write_standby: Taking no action due to ongoing warmrestart.
163 lines
5.1 KiB
Python
Executable File
163 lines
5.1 KiB
Python
Executable File
#!/usr/bin/env python3
|
|
|
|
import time
|
|
|
|
from sonic_py_common import logger as log
|
|
from swsscommon.swsscommon import ConfigDBConnector, DBConnector, FieldValuePairs, ProducerStateTable, SonicV2Connector, Table
|
|
from swsscommon.swsscommon import APPL_DB, STATE_DB
|
|
|
|
logger = log.Logger('write_standby')
|
|
|
|
REDIS_SOCK_PATH = '/var/run/redis/redis.sock'
|
|
|
|
|
|
def create_fvs(**kwargs):
|
|
return FieldValuePairs(list(kwargs.items()))
|
|
|
|
class MuxStateWriter(object):
|
|
"""
|
|
Class used to write standby mux state to APP DB
|
|
"""
|
|
|
|
def __init__(self):
|
|
self.config_db_connector = None
|
|
self.appl_db_connector = None
|
|
self.state_db_connector = None
|
|
self.asic_db_connector = None
|
|
|
|
@property
|
|
def config_db(self):
|
|
"""
|
|
Returns config DB connector.
|
|
Initializes the connector during the first call
|
|
"""
|
|
if self.config_db_connector is None:
|
|
self.config_db_connector = ConfigDBConnector()
|
|
self.config_db_connector.connect()
|
|
|
|
return self.config_db_connector
|
|
|
|
@property
|
|
def appl_db(self):
|
|
"""
|
|
Returns the app DB connector.
|
|
Initializes the connector during the first call
|
|
"""
|
|
if self.appl_db_connector is None:
|
|
self.appl_db_connector = DBConnector(APPL_DB, REDIS_SOCK_PATH, True)
|
|
return self.appl_db_connector
|
|
|
|
@property
|
|
def state_db(self):
|
|
"""
|
|
Returns the state DB connector.
|
|
Intializes the connector during the first call
|
|
"""
|
|
if self.state_db_connector is None:
|
|
self.state_db_connector = DBConnector(STATE_DB, REDIS_SOCK_PATH, True)
|
|
return self.state_db_connector
|
|
|
|
@property
|
|
def asic_db(self):
|
|
"""
|
|
Returns the ASIC DB connector.
|
|
Initializes the connector during the first call
|
|
"""
|
|
if self.asic_db_connector is None:
|
|
self.asic_db_connector = SonicV2Connector()
|
|
self.asic_db_connector.connect('ASIC_DB')
|
|
|
|
return self.asic_db_connector
|
|
|
|
@property
|
|
def tunnel_name(self):
|
|
"""
|
|
Returns the name of the IP-in-IP tunnel used for Dual ToR devices
|
|
"""
|
|
return self.config_db.get_keys('TUNNEL')[0]
|
|
|
|
@property
|
|
def is_dualtor(self):
|
|
"""
|
|
Checks if script is running on a dual ToR system
|
|
"""
|
|
localhost_key = self.config_db.get_keys('DEVICE_METADATA')[0]
|
|
metadata = self.config_db.get_entry('DEVICE_METADATA', localhost_key)
|
|
|
|
return 'subtype' in metadata and 'dualtor' in metadata['subtype'].lower()
|
|
|
|
@property
|
|
def is_warmrestart(self):
|
|
"""
|
|
Checks if a warmrestart is going on
|
|
"""
|
|
tbl = Table(self.state_db, 'WARM_RESTART_ENABLE_TABLE')
|
|
(status, value) = tbl.hget('system', 'enable')
|
|
|
|
return status and value == 'true'
|
|
|
|
def get_auto_mux_intfs(self):
|
|
"""
|
|
Returns a list of all mux cable interfaces that are configured to auto-switch
|
|
"""
|
|
all_intfs = self.config_db.get_table('MUX_CABLE')
|
|
auto_intfs = [intf for intf, status in all_intfs.items()
|
|
if status['state'].lower() == 'auto']
|
|
return auto_intfs
|
|
|
|
def tunnel_exists(self):
|
|
"""
|
|
Checks if the IP-in-IP tunnel has been written to ASIC DB
|
|
"""
|
|
tunnel_key_pattern = 'ASIC_STATE:SAI_OBJECT_TYPE_TUNNEL:*'
|
|
return len(self.asic_db.keys('ASIC_DB', tunnel_key_pattern)) > 0
|
|
|
|
def wait_for_tunnel(self, interval=1, timeout=60):
|
|
"""
|
|
Waits until the IP-in-IP tunnel has been created
|
|
|
|
Returns:
|
|
(bool) True if the tunnel has been created
|
|
False if the timeout period is exceeded
|
|
"""
|
|
logger.log_info("Waiting for tunnel {} with timeout {} seconds".format(self.tunnel_name, timeout))
|
|
start = time.time()
|
|
curr_time = time.time()
|
|
|
|
while not self.tunnel_exists() and curr_time - start < timeout:
|
|
time.sleep(interval)
|
|
curr_time = time.time()
|
|
|
|
# If we timed out, return False else return True
|
|
return curr_time - start < timeout
|
|
|
|
def apply_mux_config(self):
|
|
"""
|
|
Writes standby mux state to APP DB for all mux interfaces
|
|
"""
|
|
if not self.is_dualtor:
|
|
# If not running on a dual ToR system, take no action
|
|
return
|
|
|
|
if self.is_warmrestart:
|
|
# If in warmrestart context, take no action
|
|
logger.log_warning("Skip setting mux state due to ongoing warmrestart.")
|
|
return
|
|
|
|
intfs = self.get_auto_mux_intfs()
|
|
state = 'standby'
|
|
if self.wait_for_tunnel():
|
|
logger.log_warning("Applying {} state to interfaces {}".format(state, intfs))
|
|
producer_state_table = ProducerStateTable(self.appl_db, 'MUX_CABLE_TABLE')
|
|
fvs = create_fvs(state=state)
|
|
|
|
for intf in intfs:
|
|
producer_state_table.set(intf, fvs)
|
|
else:
|
|
logger.log_error("Timed out waiting for tunnel {}, mux state will not be written".format(self.tunnel_name))
|
|
|
|
|
|
if __name__ == '__main__':
|
|
mux_writer = MuxStateWriter()
|
|
mux_writer.apply_mux_config()
|