- Why I did it To include latest fixes: 1. Warmboot | When trying to reconfigure the Flex Parser header and Flex transition parameters after ISSU, the switch will returned an error even if the configuration was identical to that done before performing the ISSU. 2. Link Up | When toggling many ports of the Spectrum devices while raising 10GbE link up and link maintenance is enabled, the switch may get stuck and may need to be rebooted. 3. Shared buffer | While moving from lossless to lossy while shared headroom was used, reduction of the shared headroom can only be done prior to pool type change and when shared headroom is not utilized. 4. Added support for Finisar DR4 (FTCD4523E2PCM) on Spectrum-2 and Spectrum-3 systems. SAI 1. ECMP overlay support for IPv4 and IPv6 2. BFD offloading / 4K scale SAI fixes 1. Reduce verbosity of print in case packet ingress on invalid port 2. Added support for Host table entry removal API to remove registration of a trap to a channel - How I did it Updated SAI & SDK submodules along with the relevant Makefiles - How to verify it Build an image and run tests from "sonic-mgmt". Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com> |
||
---|---|---|
.. | ||