sonic-buildimage/device/arista/x86_64-arista_720dt_48s/Arista-720DT-48S/phy24_config.json
Junhua Zhai abda50c791
Correct port index in Arista-720DT-48S/phy24_config.json (#11699)
Port index 22 is associated with phy23_config.json, then same port index 22 in phy24_config.json may cause gearbox port creation error. Port Ethernet22 maps to index 23.
2022-08-17 12:48:40 +08:00

39 lines
886 B
JSON

{
"lanes": [
{
"index": 255,
"local_lane_id": 255,
"system_side": true,
"tx_polarity": 255,
"rx_polarity": 255,
"line_tx_lanemap": 255,
"line_rx_lanemap": 255,
"line_to_system_lanemap": 255,
"mdio_addr": ""
}
],
"ports": [
{
"index": 23,
"mdio_addr": "",
"system_speed": 1000,
"system_fec": "none",
"system_auto_neg": false,
"system_loopback": "none",
"system_training": false,
"line_speed": 1000,
"line_fec": "none",
"line_auto_neg": false,
"line_loopback": "none",
"line_training": false,
"line_media_type": "copper",
"line_intf_type": "none",
"line_adver_speed": [],
"line_adver_fec": [],
"line_adver_auto_neg": false,
"line_adver_asym_pause": false,
"line_adver_media_type": "copper"
}
]
}