sonic-buildimage/dockers/docker-snmp-sv2/snmpd.conf.j2
kannankvs 7cb63008d7
mvrf_avoid_snmp_yml_config: made changes to pass SNMP config from con… (#4057)
* mvrf_avoid_snmp_yml_config: made changes to pass SNMP config from confiDB to snmpd.conf without using snmp.yml
* added a missing if condition
2020-01-28 17:41:21 -08:00

168 lines
5.9 KiB
Django/Jinja

###############################################################################
# Managed by sonic-config-engine
###############################################################################
#
# EXAMPLE.conf:
# An example configuration file for configuring the Net-SNMP agent ('snmpd')
# See the 'snmpd.conf(5)' man page for details
#
# Some entries are deliberately commented out, and will need to be explicitly activated
#
###############################################################################
#
# AGENT BEHAVIOUR
#
# Listen for connections on all ip addresses, including eth0, ipv4 lo
#
{% if SNMP_AGENT_ADDRESS_CONFIG %}
{% for (agentip, port, vrf) in SNMP_AGENT_ADDRESS_CONFIG %}
agentAddress {{ agentip }}{% if port %}:{{ port }}{% endif %}{% if vrf %}%{{ vrf }}{% endif %}{{ "" }}
{% endfor %}
{% else %}
agentAddress udp:161
agentAddress udp6:161
{% endif %}
###############################################################################
#
# ACCESS CONTROL
#
# system + hrSystem groups only
view systemonly included .1.3.6.1.2.1.1
view systemonly included .1.3.6.1.2.1.25.1
# Default access to basic system info
{% if snmp_rocommunities %}
{% for community in snmp_rocommunities %}
rocommunity {{ community }}
rocommunity6 {{ community }}
{% endfor %}
{% else %}
rocommunity {{ snmp_rocommunity }}
rocommunity6 {{ snmp_rocommunity }}
{% endif %}
###############################################################################
#
# SYSTEM INFORMATION
#
# Note that setting these values here, results in the corresponding MIB objects being 'read-only'
# See snmpd.conf(5) for more details
sysLocation {{ snmp_location }}
sysContact Azure Cloud Switch vteam <linuxnetdev@microsoft.com>
# Application + End-to-End layers
sysServices 72
#
# Process Monitoring
#
# todo: should we enable snmp based monitoring of sswsyncd and other processes?
# At least one 'sendmail' process, but no more than 10
#proc sendmail 10 1
# Walk the UCD-SNMP-MIB::prTable to see the resulting output
# Note that this table will be empty if there are no "proc" entries in the snmpd.conf file
#
# Disk Monitoring
#
# 10MBs required on root disk, 5% free on /var, 10% free on all other disks
disk / 10000
disk /var 5%
includeAllDisks 10%
# Walk the UCD-SNMP-MIB::dskTable to see the resulting output
# Note that this table will be empty if there are no "disk" entries in the snmpd.conf file
#
# System Load
#
# Unacceptable 1-, 5-, and 15-minute load averages
load 12 10 5
# Walk the UCD-SNMP-MIB::laTable to see the resulting output
# Note that this table *will* be populated, even without a "load" entry in the snmpd.conf file
###############################################################################
#
# ACTIVE MONITORING
#
# Note: disabled snmp traps due to side effect of causing snmpd to listen on all ports (0.0.0.0)
#
# send SNMPv1 traps
{% if SNMP_TRAP_CONFIG and SNMP_TRAP_CONFIG['v1TrapDest'] %}
{% set v1SnmpTrapIp = SNMP_TRAP_CONFIG['v1TrapDest']['DestIp'] %}
{% set v1SnmpTrapPort = SNMP_TRAP_CONFIG['v1TrapDest']['DestPort'] %}
{% set v1SnmpTrapVrf = SNMP_TRAP_CONFIG['v1TrapDest']['vrf'] %}
{% set v1SnmpTrapComm = SNMP_TRAP_CONFIG['v1TrapDest']['Community'] %}
trapsink {{ v1SnmpTrapIp }}:{{ v1SnmpTrapPort }}{% if v1SnmpTrapVrf != 'None' %}%{{ v1SnmpTrapVrf }}{% endif %} {{ v1SnmpTrapComm }}{{ "" }}
{% else %}
#trapsink localhost public
{% endif %}
# send SNMPv2c traps
{% if SNMP_TRAP_CONFIG and SNMP_TRAP_CONFIG['v2TrapDest'] %}
{% set v2SnmpTrapIp = SNMP_TRAP_CONFIG['v2TrapDest']['DestIp'] %}
{% set v2SnmpTrapPort = SNMP_TRAP_CONFIG['v2TrapDest']['DestPort'] %}
{% set v2SnmpTrapVrf = SNMP_TRAP_CONFIG['v2TrapDest']['vrf'] %}
{% set v2SnmpTrapComm = SNMP_TRAP_CONFIG['v2TrapDest']['Community'] %}
trap2sink {{ v2SnmpTrapIp }}:{{ v2SnmpTrapPort }}{% if v2SnmpTrapVrf != 'None' %}%{{ v2SnmpTrapVrf }}{% endif %} {{ v2SnmpTrapComm }}{{ "" }}
{% else %}
#trap2sink localhost public
{% endif %}
# send SNMPv2c INFORMs
{% if SNMP_TRAP_CONFIG and SNMP_TRAP_CONFIG['v3TrapDest'] %}
{% set v3SnmpTrapIp = SNMP_TRAP_CONFIG['v3TrapDest']['DestIp'] %}
{% set v3SnmpTrapPort = SNMP_TRAP_CONFIG['v3TrapDest']['DestPort'] %}
{% set v3SnmpTrapVrf = SNMP_TRAP_CONFIG['v3TrapDest']['vrf'] %}
{% set v3SnmpTrapComm = SNMP_TRAP_CONFIG['v3TrapDest']['Community'] %}
trapsink {{ v3SnmpTrapIp }}:{{ v3SnmpTrapPort }}{% if v3SnmpTrapVrf != 'None' %}%{{ v3SnmpTrapVrf }}{% endif %} {{ v3SnmpTrapComm }}{{ "" }}
{% else %}
#informsink localhost public
{% endif %}
# Note that you typically only want *one* of these three lines
# Uncommenting two (or all three) will result in multiple copies of each notification.
#
# Event MIB - automatically generate alerts
#
# Remember to activate the 'createUser' lines above
#iquerySecName internalUser
#rouser internalUser
# generate traps on UCD error conditions
#defaultMonitors yes
#note, this release of snmpd does not support linkUpDownNotifications
# generate traps on linkUp/Down
#linkUpDownNotifications yes
#
# AgentX Sub-agents
#
# Run as an AgentX master agent
master agentx
# internal socket to allow extension to other docker containers
# Currently the other container using this is docker-fpm-frr
# make sure this line matches bgp:/etc/snmp/frr.conf
# please see testing procedure in the same file to verify this works
# to verify the SNMP docker side look for the following string in the log file:
# INFO snmp-subagent [ax_interface] INFO: Using agentx socket type tcp with path tcp:localhost:3161
# INFO supervisord snmp-subagent INFO:ax_interface:Using agentx socket type tcp with path tcp:localhost:3161
agentxsocket tcp:localhost:3161
#
# SysDescription pass-through
#
pass -p 10 .1.3.6.1.2.1.1.1 /usr/share/snmp/sysDescr_pass.py